MAURY USCG vessel records
← All vessels

MICHIPICOTEN

MICHIPICOTEN is a 1952 freight ship. The Coast Guard has recorded 45 inspections since 2016, most recently in June 2024, along with 22 deficiencies — 1 with no resolution recorded —, 2 operational controls, 1 with no removal date recorded and 3 casualty investigations between 2010 and 2014.

Records from 2010 to 2024. Most recent: operational control imposed, 19 June 2024.

Built
1952
Last inspected
8 June 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 June 2024
…with no type recorded9
Operational controls 1 with no removal date recorded
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

5102865
CFG8060
Flag
CANADA
Maury page id
psix-42778

Documentation record

Tonnage as PSIX records it15366 - Convention (Subpart B), Gross Ton
4609 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KAYE E. BARKER Freight Ship · MISLE 42766 · 11 December 2023 · activity 7842839

Inspection history · 45

8 June 2024 In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7930657
8 June 2024 Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7971638
25 May 2024 In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7918951
25 May 2024 Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7946615
6 May 2024 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7907401
3 April 2024 PSC B · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7888585
29 March 2024 In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7886823
29 March 2024 Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7895384
12 December 2023 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7839000
11 December 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7837305
11 December 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7842839
7 November 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7821634
7 November 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7822467
9 May 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7684553
28 March 2023 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7658555
4 October 2022 PSC B · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7571135
3 October 2022 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7570667
30 September 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7569008
13 June 2022 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7476125
17 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7453027
16 May 2022 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7451851
15 May 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7451400
5 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7428814
25 January 2022 In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7385565
5 May 2021 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7190367
4 April 2021 PSC B
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7168318
2 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7167441
18 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7113812
23 November 2020 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7101168
23 November 2020 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7112949
20 September 2019 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6816482
8 June 2019 Canadian Vsl Safety Exam (D9 only)
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6707323
4 June 2019 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6703503
29 May 2019 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6697996
28 May 2019 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6696493
25 May 2019 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6693060
20 May 2019 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6688530
15 May 2019 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6685423
21 November 2018 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6584840
31 October 2018 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6572173
15 May 2018 Canadian Vsl Safety Exam (D9 only) · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6415390
23 July 2017 Canadian Vsl Safety Exam (D9 only)
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6217796
27 November 2016 Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6058286
22 July 2016 Canadian Vsl Safety Exam (D9 only)
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5948216
16 June 2016 Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5909172

Deficiency record · 22

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 July 2024 No resolution recorded
In general, compliance with the standards established by the American Bureau of shipping, will be considered as satisfactory evidence of the structural efficiency of the vessel. On June 8, 2024 after departing two harbors at approximately 0825 the vessel reported taking on water and the flooding of the centerline tank, and starboard #4 tanks. The vessel entered into an emergency dry dock at Fraser Shipyard in Superior, WI to address permanent repairs to the hull. Vessel is required to make permanent repairs to the hull to the satisfaction of the Class Society, Flag State, and the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 June 2024 Resolved
In general, compliance with the standards established by the American Bureau of shipping, will be considered as satisfactory evidence of the structural efficiency of the vessel. On June 8, 2024 after departing two harbors at approximately 0825 Vessel reported taking on water and the flooding of the centerline tank, and starboard #4 tanks. Vessel will complete an underwater survey with class in attendance.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 June 2024
Resolved 20 June 2024
Resolution: Vessel completed temporary repairs to transit to drydock in Superior, WI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2024 Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of sub-chapter F...The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules. The turbocharger of the starboard engine is non-operational, consequently rendering the starboard engine inoperable. As a result, the vessel is currently transiting with only one engine functional.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2024
Resolved 20 June 2024
Resolution: Receieved class and flag attestation to proper repair.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2024 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. The electrical control box for the ballast piping valve has faulty relay switch and crew is using broom handle to close switch to operate the valve.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 2 May 2024
Resolution: Received Class Report attesting to rectification of deficiency.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2024 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. The engine room has loose exposed wires remaining from removed electrical equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2024
Resolved 2 May 2024
Resolution: Received Class Report attesting to rectification of deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2024 Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), except as otherwise provided by this subchapter. Vessel reported that their oil mist detector alarm went off when 95% oil mist was detected in the associated cylinder head on the port main diesel engine. Crew found a faulty fuel line allowing the injection of too much fuel into the cylinder head. Crew replaced fuel line and the oil mist detector reads 0%. Requesting a class report to clear the deficiency.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2024
Resolved 29 March 2024
Resolution: Received class report attesting to repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 October 2022 Resolved
M/V MICHIPICOTEN discovered a crack in the port quarter hull approximately 6 inches in length.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 4 October 2022
Resolved 4 October 2022
Resolution: Repair witnessed and approved by vessel class
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2022 Resolved
Port main engine shut down. Conduct appropriate repairs providing proof of proper operation of the port main engine. Vessel allowed to transit on the starboard engine in a reduced propulsion status until June 08.
Action required: 705 - Other - as specified
Due 8 June 2022
Resolved 13 June 2022
Resolution: Master M/V MICHIPICOTEN provided MSU Toledo with a copy of Class Report from ABS certifing repairs to the starboard main engine were complete and satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2022 Resolved
Vessel failed to submit a NOA prior to arrival.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 5 April 2022
Resolved 5 April 2022
Resolution: MSU Toledo contacted the vessel master. Master stated he did not think he could submit multiple NOA's for the same COTP zone. The master submitted a NOA while on the phone with MSU Toledo.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 May 2021 Resolved
CITE: 46CFR92.07-10(c). The boundary bulkheads and decks separating the accommodations from machinery spaces shall be of “A” Class construction. The bulkhead separating the laundry room from the steering gear room has cutouts covered by cardboard and does not meet "A" Class construction standards.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 14 May 2021
Resolution: See Class Report
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 May 2021 Resolved
CITE: 46CFR92.07-10(c). The boundary decks separating the accommodations from machinery spaces shall be of “A” Class construction. The escape ladder opening from the Engine control room is covered by a non permanent plate and not of "A" Class construction.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 14 May 2021
Resolution: Condition of Class was issued by RO. Def Cleared
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2021 Resolved
Cite: 33CFR160.205: The owner, agent, Master, operator, or person in charge of a vessel must submit notices of arrival consistent with the requirements in this subpart. The vessel arrived 24 hours prior to their ENOA arrival time and did not update the NOA at least 12 hours before arriving at the port or place of destination.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 April 2021
Resolved 4 April 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2021 Resolved
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must maintain a ballast water management (BWM) plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy and comply with the requirements of this subpart. The vessel does not have a BWM Plan implemented that meets this subpart.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2021
Resolved 6 April 2021
Resolution: Per D9: Canadian vessels designated as Candian Lakers built prior to 2009 are exempt from BWM regulations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2021 Resolved
The master, owner, operator, agent, or person in charge of a vessel subject to this subpart and this section must submit a ballast water report to the National Ballast Information Clearinghouse (NBIC). The vessel does not submit reports to ballast water to NBIC.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 April 2021
Resolved 6 April 2021
Resolution: Per D9: Canadian vessels designated as Candian Lakers built prior to 2009 are exempt from BWM regulations.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 4 April 2021 Resolved
Each outlet or junction box must have a cover unless a fixture canopy, switch cover, receptacle cover, or other cover is used. The vessel has an outlet with no cover or fixture canopy in the Oil Purifier Room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 5 May 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 4 April 2021 Resolved
The boundary bulkheads and decks separating the accommodations from machinery spaces shall be of “A” Class construction. The bulkhead separating the laundry room from the steering gear room has cutouts covered by cardboard and does not meet "A" Class construction standards.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2021
Resolved 14 May 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 4 April 2021 Resolved
The boundary decks separating the accommodations from machinery spaces shall be of “A” Class construction. The escape ladder opening from the Engine control room is covered by a non permanent plate and not of "A" Class construction.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2021
Resolved 14 May 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 4 April 2021 Resolved
The decks shall be constructed of steel. The engine room deck where the boiler was removed has a plate tack welded in place and is not a permanently installed steel plate.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2021
Resolved 5 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 April 2021 Resolved
Each vessel must have for the area to be transited, a currently corrected copy of U.S Coast Pilot. The vessel has switched to an electronic format for publications but still keeps old inaccurate books on board.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 5 May 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 November 2020 Resolved
A survey shall be made every time a defect is discovered which affects the safety of the vessel, one crack (6-8 inches in length) was found in the hull of the #5 ballast tank which caused water ingress. Effect permanent repairs to starboard side #5 ballast tank hull plating fracture to the satisfaction of attending class surveyor.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 November 2020
Resolution: ABS Report attesting to temp repairs are attached in documents
Construction/Loadline › Hull › Side Shell
Issued 15 May 2018 Resolved
Vessel is required to make satisfactory repairs to the 5" crack, in way of the #5P ballast tank, to the satisfaction of class prior to re-entering U. S. waters. (33 CFR 160.113(a); D9INST 16711.4)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 May 2018
Resolved 21 May 2018
Resolution: Rcvd ltr from ABS confirming repairs satisfactorily completed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 July 2016 Resolved
Vessels over 10,000 GT shall have second operational radar onboard. The S-band 10cm radar was not functional during test of the system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2016
Resolution: Received tech report from Marine Technical Services. Magnetron failure. New unit installed by [name withheld].

Casualty record · 3

21 August 2010Routine · role: Involved in a Marine Casualty · activity 3832851
28 November 2013Routine · role: Involved in a Marine Casualty · activity 4761915
4 September 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4977658
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.