OUTWARD BOUND

OUTWARD BOUND is a 1995 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1995, most recently in October 2025, along with 107 deficiencies and 1 casualty investigation in 2007.

Records from 1995 to 2025. Most recent: inspection, 8 October 2025.

Built
1995
Last inspected
8 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI8553
428222
Flag
UNITED STATES
367739760
Maury page id
psix-428222

Inspections, by type

…with no type recorded8
Years with a record 28 calendar years (1995–2025)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 19.0 ft × 8.2 ft
Registered tonnagegross 67 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLADDING-HEARN SHIPBUILDING · SOMERSET, MA, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Simplified, Gross Ton
54 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI8553MMSI 367739760 · active · compulsorily equipped · granted 7 August 2026, expires 10 June 2036
WDC9849MMSI 367107440 · expired · compulsorily equipped · granted 15 April 2006, cancelled 18 June 2016
WCU7114MMSI 366698060 · expired · compulsorily equipped · granted 29 September 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ANNA R Passenger (Inspected) · MISLE 330640 · 29 May 2002 · activity 1622459

Inspection history · 55

8 October 2025 Drydock Exam · Vessel Attendance · Plan Review "T" Boat · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8249448
25 March 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8088215
5 March 2024 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7874543
7 February 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7851191
3 November 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7820747
29 April 2021 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7180750
11 March 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7154274
11 December 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7110180
25 February 2020 Deficiency Check · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6915409
10 January 2020 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6888959
17 December 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6874572
3 July 2019 Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6734620
16 April 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6663327
10 December 2018 Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6593509
21 December 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6327365
16 December 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6065724
27 September 2016 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6010322
1 April 2016 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5845376
2 February 2016 Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5811356
24 November 2015 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5769698
5 January 2012 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4219184
29 September 2011 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4151537
3 November 2010 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3883946
28 September 2010 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3858756
30 March 2009 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3442643
30 September 2008 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3335270
2 October 2007 Administrative Inspection · Re-Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3070947
26 March 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2896219
5 March 2007 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2882112
25 September 2006 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2786510
3 October 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2506433
23 June 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2406513
19 April 2005 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2337426
27 October 2004 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2229219
16 December 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1964885
27 October 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1936697
22 April 2003 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1778534
30 September 2002 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1691392
29 May 2002 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1622459
14 October 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 49389
3 October 2001 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1456022
17 April 2001 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1362126
10 April 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1063117
9 April 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 171642
9 April 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1366266
19 March 2001 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1061436
4 October 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1413812
1 October 1999 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1361137
2 October 1998 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 802646
31 October 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 781129
23 April 1997 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1106146
11 October 1996 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 841654
26 September 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1140616
18 December 1995 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1185104
11 October 1995 Initial Certification · Plan Review "T" Boat · Inclining Experiment · Initial Construction-Excluding Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1188194

Deficiency record · 107

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 July 2026 Resolved
A vessel that carries more than 49 passengers that is not more than 65 feet is required to have 1 fixed power bilge pump and 1 portable hand pump. A secondary powered bilge pump may serve as an alternative to the hand pump. The engine driven bilge pump was not operational at the conclusion of the drydock examination. Repair engine driven bilge pump and prove proper operation. Vessel is authorized to transit to homeport in Boston Harbor with the powered fire pump serving as the bilge pump.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 July 2026
Resolution: Proved proper operation of bilge pump after clearing discharge outlet of accumulated blast media.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2026 Resolved
Cable must be installed with metal supports spaced not more than 24 inches apart. Cables in the engine room have metal supports spaced more than 24 inches. Ensure all cables in the engine room have supports spaced no more than 24 inches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2026
Resolved 20 July 2026
Resolution: Metal brackets provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 January 2026 Resolved
C&R the sbd side forpeak as marked to good metal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2026
Resolution: See Activity Number 8249448.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 8 October 2025 Resolved
C&R the lower aft steering to Engine room bulkhead to good metal.
Action required: 705 - Other - as specified
Resolved 2 June 2026
Resolution: See Activity Number 8249448.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 8 October 2025 Resolved
All observed hazardous conditions must be corrected. The light for the exterior stairwell was not operational, Prove proper operation of the exterior stairwell light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2026
Resolved 20 July 2026
Resolution: Lightbulb was replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Trash can on board was constructed of plastic with no lid. 46 CFR 177.405(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 27 March 2025
Resolution: Operator submitted objective evidence (photos) of approved metal trash receptacles.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 March 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Battery operated portable flashlight at the operating station was inoperable. 46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 27 March 2025
Resolution: Operator submitted objective evidence (photos) of working flashlights.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 March 2024 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. During inspection, crew was not able to demonstrate full competency in recovering a person falling overboard due to not conducting sufficient drills to achieve satisfactory results. Master and crew are to conduct sufficient training and demonstrate satisfactory drills to the satisfaction of the attending marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2024
Resolution: Attended vessel and observed satisfactory man overboard drill with crew.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 March 2024 Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly using the integrated test circuit and output indicator to determine that it is operative and shall be logged or otherwise documented. After reviewing the vessel's log, there was no documentation or log entry of monthly EPIRB testing. Informed vessel master of monthly test requirement and log entry. Provide evidence of EPIRB monthly test log entry to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2024
Resolution: Attended vessel and observed an established means of logging EPIRB testing, along with a recent EPIRB test.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 11 March 2024 Resolved
The master of a vessel shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. During inspection, master stated vessel documents passenger count via vessel log entry, but has not established a method of relaying passenger count ashore. Vessel must establish means of communicating passenger count ashore prior to each voyage with passengers. Provide proof of means to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2024
Resolution: Attended vessel and observed installed mailbox on pier dedicated for recording passenger count prior to each voyage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 March 2024 Resolved
At each initial and subsequent inspection for certification of a vessel the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including operational test of the means provided for pumping bilges. During inspection, the bilge suction in the forward compartment and forward cabin were not operable. Fix and provide proof of proper operation of all bilge suction points to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2024
Resolution: Attended vessel and observed satisfactory operation of all bilge suction points.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 March 2024 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. During inspection, there was no documentation of abandon ship and man overboard drills being done. Master is responsible for ensuring such drills are properly documented and available for review by Coast Guard upon request.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2024
Resolution: Attended vessel and observed dedicated drill logbook with recent drills logged.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 March 2024 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. During inspection, the vessel did not have a valid Certificate of Documentation (COD). Vessel is not allowed to operate or move until evidence is provided to marine inspector that a new COD has been paid for and is in processing.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2024
Resolution: Vessel rep provided proof of payment and COD processing by end of inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 March 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46CFR199.175(b)(10) or a kit with equivalent contents and instructions. Several items in vessel's first aid kit were found expired. Replace expired medication items in first aid kid.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2024
Resolution: Vessel rep replaced expired first aid medication by end of inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 November 2023 Resolved
To maintain a valid Certificate of Inspection, you must complete an annual inspection within the periods specified in § 176.500(b)(1) and your Certificate of Inspection must be endorsed. The vessel missed the annual inspections for CY 2022 and 2023. Vessel is prohibited from carrying passengers for hire until a satisfactory COI renewal inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2023
Resolved 11 March 2024
Resolution: Conducted COI renewal on vessel. Activity #7874543.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 November 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structural at least once every 2 years. Vessel did not conduct the require hull exam before the due date of 31MAR23. Vessel must complete satisfactory hull exam prior to the carriage of passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2023
Resolved 15 February 2024
Resolution: Hull exam credited.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2019 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment except as follows: The space forward of the collision bulkhead need not be fitted with a bilge suction line when the arrangement of the vessel is such that ordinary leakage may be removed from this compartmant by the use of a hand portable bilge pump or other equipment and such equipment is provided. MI observed the bilge system was unable to draw suction from the forward compartment and there was no other equipment available to remove water. Correct prior to carrying passengers
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 February 2020
Resolved 30 March 2020
Resolution: Replaced existing bilge piping, valves, strainers and fittings of fixed bilge system in kind. Tested SAT.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 17 December 2019 Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required shall be logged or otherwise documented. Vessel representative stated they do not keep a log of EPIRB testing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2020
Resolved 10 January 2020
Resolution: Vessel Rep submitted updated EPRIB maintenance procedures, including monthly EPIRB test log, to Sector Boston.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 April 2019 Resolved
One life raft sent out for service. Vessel restricted to one mile from shore untill IBA is returned.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2019
Resolution: Verified proper installation of serviced liferaft.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 March 2019 Resolved
Operator requested replacing existing life floats with IBAs. Provide installation proposal fro approval, install if approved, schedule inspection of installation with CG. Must be corrected prior to carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2019
Resolution: Verified proper installation of IBAs as approved.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 December 2018 Resolved
Each life float must be fitted with a light. Water light on life float intermittently operates.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2018
Resolved 15 January 2019
Resolution: life float fitted with a light. tested, sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2018 Resolved
A vessel's hull must not carry current. Main switchboard ground detection system indicated current on the hull in excess of 10 amps. Must be corrected prior to carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2019
Resolution: Found faulty AMP meter, replaced meter, tested sat.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 10 December 2018 Resolved
Overboard discharge on stbd side has no check/positive action valve. Ensure no water ingress by installing valve or terminating discharge if not in use. Must be corrected prior to carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2019
Resolution: Terminated discharge.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 December 2018 Resolved
Wasted transverse frame on starboard side forepeak. Crop and renew in kind to good metal. Must be corrected prior to carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2019
Resolution: cropped renewed to good metal in kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 December 2018 Resolved
Wasted frame on port side support to Laz hatch. Crop and renew in kind to good metal. Must be corrected prior to carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2019
Resolution: Cropped renewed in kind to good metal.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 December 2018 Resolved
Main deck aft wasted IWO emergency steering tiller access cap. Crop and renew in kind to good metal. Must be corrected prior to carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2019
Resolution: Cropped renewed in kind to good metal. tested, sat
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 December 2018 Resolved
Wasted areas IWO port engine room bilge. Conduct thickness gauging and provide repair proposal for approval. Must be corrected prior to carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2019
Resolution: Gauging complete. Identified 36x20 area that requires crop and renew. Discussed expectations with vessel rep. tested weld sat
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 December 2018 Resolved
Wasted steel IWO aft pilot house and deck. Provide repair proposal. Must be corrected prior to carrying passengers for hire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2019
Resolution: Cropped, renewed to good metal. Tested weld sat.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 21 December 2017 Resolved
Repair leak in transmission on main diesel.
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 6 March 2018
Resolution: Leak on transmission was repaired.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 21 December 2017 Resolved
Minimize or eliminate amps to ground.
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 26 January 2018
Resolution: Amp to ground indicator read less than 1 amp.
Communications › Radio Communications › EPIRB
Issued 21 December 2017 Resolved
Install appropriate hydrostatic release unit on EPIRB.
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 26 January 2018
Resolution: Installed appropriate hydrostatic release unit on EPIRB.
Electrical › Electric Generation Source (service) › Conductor
Issued 21 December 2017 Resolved
Remove or replace in electrical box, dead end wires in void #2 and engine room.
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 26 January 2018
Resolution: Removed dead end wires in void #2 and engine room.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 December 2017 Resolved
Replace line on life ring on bow.
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 26 January 2018
Resolution: Replaced line on life ring on bow.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 21 December 2017 Resolved
Provide emergency instructions list.
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 26 January 2018
Resolution: Provided emergency instructions list.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 December 2017 Resolved
Repair light on life float light.
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 26 January 2018
Resolution: Repaired light on life float light.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 21 December 2017 Resolved
Repair/replace the amp to ground indicator to working condition.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 6 March 2018
Resolution: Replaced gauge on amp to ground indicator.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 21 December 2017 Resolved
Remove oily water from the E/R bilge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 6 March 2018
Resolution: Oily water was removed from the bilge.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 27 September 2016 Resolved
Fire dampers missing on both intakes. Provide dampers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 25 October 2016
Resolution: Vessel rep. provided fire dampers.
Fire Fighting › Fire Hoses › Material
Issued 27 September 2016 Resolved
Missing 02 nozzles for fire hoses. Provide 02 nozzles.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 25 October 2016
Resolution: Two nozzels were provided.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 27 September 2016 Resolved
Missing life jacket stowage signs. Provide signage.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 25 October 2016
Resolution: Life jacket stowage signs were installed.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 27 September 2016 Resolved
Provide logs on fire fighting and MOB drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 25 October 2016
Resolution: Vessel rep performed and logged drills.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 September 2016 Resolved
Provide coast pilot and light list.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 25 October 2016
Resolution: Vessel provided publications.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 September 2016 Resolved
Label 02 emergency escape hatches.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 25 October 2016
Resolution: Emergency escape hatches were labeled.
Lifesaving › Lifefloat › Markings
Issued 27 September 2016 Resolved
Stencil name of VSL and capacity on LFs and paddles.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 25 October 2016
Resolution: Life floats were stenciled.
Lifesaving › Lifefloat › Paddle
Issued 27 September 2016 Resolved
Missing 02 paddles. Provide 02 paddles, lashed to LF.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 25 October 2016
Resolution: Two addtional paddles were provided and lashed.
Engineering › Bilge Water Management System › Not Operational
Issued 27 September 2016 Resolved
Provide proper operation of valve at bilge manifold for FWD peak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 25 October 2016
Resolution: Bilge manifold valve operates properly.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 April 2016 Resolved
Water light was cracked. Still operational and float tested sat. New light was on order. Current light authorized until new one arrives.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 14 April 2016
Engineering › Bilge Water Management System › Not Operational
Issued 24 November 2015 Resolved
Bilge System is inoperable. Must prove proper operation of bilege system prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Witnessed satisfactory operation of bilge pump by pumping out fore peak.
Fire Fighting › Fire Pumps › Pressure
Issued 24 November 2015 Resolved
Fire Pump is inoperable. Must prove proper operation prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Witnessed satisfactory operation of fire pump.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 24 November 2015 Resolved
Lifefloat light is inoperable. Repair or replace in kind prior to operating at night.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Examined new water light.
Communications › Radio Communications › EPIRB
Issued 24 November 2015 Resolved
EPIRB hydrostatic release is expired. Replace in kind. Vessel restricted within three miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Examined new hydro.
Communications › Radio Communications › EPIRB
Issued 24 November 2015 Resolved
EPIRB registration is expired. Replace with current registration. Vessel restricted to within three miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Witnessed EPIRB registration.
Electrical › Lighting (service) › Outlet Box
Issued 24 November 2015 Resolved
Forward compartment junction box missing cover. Provide cover.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Junction box was removed.
Electrical › Lighting (service) › Grounding Conductor
Issued 24 November 2015 Resolved
Electrical ground found on AC voltage system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 24 November 2015
Resolution: Corrected on the spot. Found an electrical heater causing ground.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 November 2015 Resolved
Engineroom escape scuttle not labeled on deck. Provide proper label.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2016
Resolution: Rcvd photos of labeled hatch
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 November 2015 Resolved
Lifebouy waterlight lanyard is missing corrosion-resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Witnessed installed corrosion resistant clip.
Construction/Loadline › Hull › Hull Plating
Issued 24 November 2015 Resolved
During scheduled Dry Dock period provide repair proposal for scheduled steerl work on Bow. Complete repairs prior to completion of Dry Dock period.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Repairs witnessed on 02FEB16.
Construction/Loadline › Hull › Hull Plating
Issued 24 November 2015 Resolved
During schedule Dry Dock period provide explanation of cement in lazarette and wood on transducer through hull. Prior to completion of Dry Dock period.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Done on 02FEB16
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 November 2015 Resolved
Unable to perform drills. Perform drills before spring operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Conducted satisfactory MOB and fire drills.
Lifesaving › Lifefloat › Serviceable
Issued 22 September 2011 Resolved
Lifefloats are in disrepair (holed, cracked and no longer serviceable). Replace lifefloats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2011
Resolved 27 October 2011
Resolution: Rcvd invoice for the purchase of two new lifefloats.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 September 2011 Resolved
Ringbuoy/lifefloat lights contain alkaline batteries impacting buoyancy of light. Replace with proper batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2011
Resolved 27 October 2011
Resolution: Rcvd invoice for the purchase of the appropriate water light batteries.
Fire Fighting › Fire Pumps › Power Source
Issued 3 November 2010 Resolved
Engine driven fire pump was inop. Make repairs, perform satisfactory test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2011
Resolution: Replaced pump in kind. Tested with satisfactory results
Lifesaving › Lifefloat › Markings
Issued 3 November 2010 Resolved
Lifefloat (2 with capacity of 22 persons each) need to be attached to the vessel with weak link and approved line and need to be relabeled. Attach lifeboats to the vessel and re-label properly.
Action required: 705 - Other - as specified
Resolved 1 April 2011
Resolution: Lifefloats were maintained, labeled and new line and weak link were installed.
Navigation › Piloting/Steering › Steering Magnetic Compass
Issued 3 November 2010 Resolved
Magnetic Compass light is inoperable. Make repairs to same
Action required: 705 - Other - as specified
Resolved 1 April 2011
Resolution: Magnetic compass light replaced with new one, tested sat
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 November 2010 Resolved
Ring buoy in operating station is missing retro-tape. Install retro-tape
Action required: 705 - Other - as specified
Resolved 1 April 2011
Resolution: Installed new retro reflective tape.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 3 November 2010 Resolved
Master did not have radio operator permit. Provide radio operator permit.
Action required: 705 - Other - as specified
Resolved 1 April 2011
Resolution: Provided radio operator permit
Lifesaving › Buoyant Apparatus › Painter
Issued 30 September 2008 Resolved
Replace the painter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Lifesaving › Buoyant Apparatus › Lifeline
Issued 30 September 2008 Resolved
Replace life lines as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Lifesaving › Buoyant Apparatus › Marking
Issued 30 September 2008 Resolved
Stencil the vessels name and capacity on both BA's.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Lifesaving › Buoyant Apparatus › Serviceable
Issued 30 September 2008 Resolved
Patch all holes in the BA's with a manufactures approved repair kit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Communications › Radio Communications › EPIRB
Issued 30 September 2008 Resolved
Prove proper registration of the EPIRB and the expiration date on the hydro release.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 September 2008 Resolved
Inspect as needed all portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Stability › Weathertight Integrity › General
Issued 30 September 2008 Resolved
Repair the foward emergency hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 September 2008 Resolved
Stencil vessels name on the foward lifering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Electrical › Electric Supply System (service) › Cable
Issued 30 September 2008 Resolved
Properly remove or terminate exposed wiring on the upper deck and foward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Engineering › Fuel Oil Service System › Valve
Issued 30 September 2008 Resolved
Label the port and starboard emergency fuel shut offs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 17 October 2008
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 30 September 2008 Resolved
Tighten engine mounting bolts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2008
Resolved 1 October 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 October 2007 Resolved
Replace the compass light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 17 October 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 October 2007 Resolved
Replace outdated navigation publications.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 17 October 2007
Engineering › Bilge Water Management System › Not Operational
Issued 2 October 2007 Resolved
Repair or replace the engine room bilge high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 17 October 2007
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 2 October 2007 Resolved
Write and post by the emergency bilge pump, proper operating instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 17 October 2007
Lifesaving › Lifefloat › Serviceable
Issued 2 October 2007 Resolved
Repair the holes in the life floats with an approved repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 17 October 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 October 2007 Resolved
Apply the vessels name on the bridge life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 17 October 2007
Engineering › Bilge Water Management System › Pump
Issued 2 October 2007 Resolved
Inspect and replace the impellar for the main engine driven bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 17 October 2007
Engineering › Bilge Water Management System › Valve
Issued 27 October 2004 Resolved
PROVIDE REACH-ROD FOR BILGE SUCTION FORE PEAK ISOLATION VALVE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 10 December 2004
Resolution: Examined and witnessed satisfactory test of new reach rod.
Construction/Loadline › Structures › Door
Issued 27 October 2004 Resolved
PROPERLY REPAIR AFT WEATHERTIGHT DOOR KNOB/LATCH MECHANISM IN MAIN DECK ACCOMIDATIONS.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 10 December 2004
Resolution: Examined new door latch. All sat.
Communications › Radio Communications
Issued 27 October 2003 Resolved
Vessel is limited to within 3 miles of land until proper registration and Hydrostatic release is provided for EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 14 November 2003
Resolution: Vessel installed proper hydro release and registered EPIRB.
Navigation › Piloting/Steering
Issued 27 October 2003 Resolved
Provide deviation card for magnetic compass. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 14 November 2003
Resolution: Provided deviation card.
Communications › Visual Communication
Issued 27 October 2003 Resolved
Provide written posted instruction for installed bilge system.
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 14 November 2003
Resolution: Written instructions are posted.
Construction/Loadline › Penetrations
Issued 27 October 2003 Resolved
Replace gaskets on Watertight hatches. LEGACY COMPONENT DESC: Gasket
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 14 November 2003
Resolution: Replaced gaskets.
Engineering › Bilge Water Management System
Issued 27 October 2003 Resolved
Provide Hand bilge pump. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 14 November 2003
Resolution: Provided hand bilge pump.
Navigation
Issued 30 September 2002 Resolved
Renew bulb for the anchor light.
Due 30 September 2002
Resolved 11 October 2002
Navigation
Issued 30 September 2002 Resolved
Renew gasket for masthead light.
Due 30 September 2002
Resolved 11 October 2002
Lifesaving
Issued 30 September 2002 Resolved
Label forward locker for life preservers.
Due 30 September 2002
Resolved 11 October 2002
Communications › Radio Communications
Issued 30 September 2002 Resolved
Renew battery for 406 EPRIB.
Due 30 September 2002
Resolved 11 October 2002
Navigation
Issued 3 October 2001 Resolved
Install Emergency broadcast placard for VHF-FM radio.
Condition: Unknown
Due 24 October 2001
Resolved 25 October 2001
Lifesaving
Issued 3 October 2001 Resolved
Install updated hydro release for EPIRB. Vessel limited to L,B,S route until completed.
Condition: Unknown
Due 24 October 2001
Resolved 25 October 2001
Fire Fighting
Issued 3 October 2001 Resolved
Repair or Prove proper operation of engine driven fire/bilge pump.
Condition: Unknown
Due 24 October 2001
Resolved 25 October 2001
Lifesaving
Issued 3 October 2001 Resolved
Replace aft ring buoy.
Condition: Unknown
Due 24 October 2001
Resolved 25 October 2001
Lifesaving
Issued 3 October 2001 Resolved
Provide 3 additional Adult size Lifejackets.
Condition: Unknown
Due 24 October 2001
Resolved 25 October 2001
Navigation
Issued 3 October 2001 Resolved
Provide approriate Light list, Coast Pilot, and Tide Currents publications.
Condition: Unknown
Due 24 October 2001
Resolved 25 October 2001
Engineering
Issued 9 April 2001 Resolved
RESTRICTED FROM CARRYING PASSENGERS UNTIL PROPER REPAIRS ARE MADE TO MAIN DIESEL ENGINE, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 April 2001
Resolved 16 April 2001
Lifesaving
Issued 4 October 2000 Resolved
PROVIDE COAST GUARD APPROVED MEDICAL KIT OR EQUIVELANT.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Electrical
Issued 4 October 2000 Resolved
PROVIDE GUARDS FOR ALL OUTSIDE LIGHTING FIXTURES ON THE MAIN DECK.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Lifesaving
Issued 1 October 1999 Resolved
VESSEL'S EPIRB SENT OUT FOR SERVICING. VESSEL'S ROUTE RESTRICTED TO NOT MORE THAN 3 MILES FROM SHORE UNTIL REPAIRED AND MOUNTED.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Documentation
Issued 2 October 1998 Resolved
Provide FCC radio operator's license for each employee who serves as a master for the vessel.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Lifesaving
Issued 11 October 1995 Resolved
Conduct fire and man overboard drills to the satisfaction of the attending marine inspector prior to placing the vessel in service but no later than 20 October 1995.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995

Casualty record · 1

26 March 2007Routine · role: Involved in a Marine Casualty · activity 2896219
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.