Records from 2008 to 2025. Most recent: inspection, 13 May 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
13 May 2025
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8117736
22 August 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7986054
8 April 2024
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7850582
12 February 2024
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7862202
4 October 2023
Type not recorded
No type recorded · USCGC HALIBUT (WPB 87340) · USCG Southwest District (CGD-SW) · Activity 7805466
24 August 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7776051
23 August 2022
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7518551
1 February 2022
Deficiency Check · Plan Review "T" Boat · Hull Examination · Construction Oversight
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7385675
18 August 2021
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7224092
28 January 2021
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7130373
26 May 2020
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6951591
31 March 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6933862
30 July 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6751838
28 January 2019
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6616720
20 August 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6518266
15 May 2018
Type not recorded
No type recorded · Station Channel Islands Harbor · USCG Southwest District (CGD-SW) · Activity 6495688
22 January 2018
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6341755
16 August 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6240699
14 February 2017
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6087500
17 August 2016
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5968866
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 August 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel did have records of monthly portable fire extinguisher inspection. Perform required monthly inspections IAW NFPA 10, provide inspection to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2024
Resolved 2 October 2024
Resolution: Vessel conducted inspection.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 August 2024
Resolved
The master of the vessel shall ensure that:(a) Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative;(b) The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner; and(c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Perform required EPIRB test and log. Provide results and logged inspection to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2024
Resolved 2 October 2024
Resolution: Vessel conducted monthly inspection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 August 2022
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Servicing report showing maintenance and tests conducted was not avilable on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2022
Resolved 24 August 2022
Resolution: Vessel provided servicing report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 August 2022
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. The marking showing the number of adult lif4e jackets under the starboard bench was inaccurate and peeling off.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2022
Resolved 24 August 2022
Resolution: Vessel properly marked locations.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 August 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84), so as to be visible at the following minimum ranges:(b)In a vessel of 12 meters or more in length but less than 50 meters in length: (ii) A sidelight, 2 miles.
Starboard running light lens was etched and light was not emitting at sufficient intensity.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2022
Resolved 6 September 2022
Resolution: Vessel replaced starboard running light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 August 2022
Resolved
The Rules concerning shapes shall be complied with by day. The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84). Vessel was not carrying day shapes. Provide day shapes.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2022
Resolved 6 September 2022
Resolution: Vessel provided day shapes.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 May 2020
Resolved
Provide a operating fixed fire system in E/R.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 May 2020
Resolution: Vessel provided an operating fixed fire system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2020
Resolved
Provide 04 life jackets. Vessel is restricted to the carriage of 21 adult pax.
Action required: 705 - Other - as specified
Resolved 29 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2020
Resolved
Provide corrosion resistant clips for life ring throw line and provide the proper size throw line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2020
Resolution: Clips and line provided.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 30 July 2019
Resolved
Provide MIS report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Report provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 July 2019
Resolved
Provide 01 adult life jacket. Passenger count reduced to 24.
Action required: 705 - Other - as specified
Due 30 July 2019
Resolved 30 July 2019
Resolution: 01 Adult life jacket provided.
Documentation › Certificates/Documents › Stability Letter
Issued 22 January 2018
Resolved
Passenger count reduced to 15 until O/O can conduct a SST.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 27 March 2018
Resolution: Completed SST, all sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 August 2017
Resolved
Cap out-of-service thru-hull valve in E/R.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 15 September 2017
Stability › Weathertight Integrity › General
Issued 16 August 2017
Resolved
Install weathertight door on deck house.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2018
Resolved 27 March 2018
Resolution: Door made weathertight.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 16 August 2017
Resolved
Make sewage overboard valve (skin valve) readily accessible. Sewage valve must be closed within 3NM of mainland shore, and within 6NM of Channel Islands.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 27 March 2018
Resolution: Valve made accessible.
Lifesaving › Hand Flares › Expired
Issued 16 August 2017
Resolved
Replace all flares NLT 01OCT17.
Action required: 705 - Other - as specified
Due 1 October 2017
Resolved 22 September 2017
Engineering › Bilge Water Management System › Pump
Issued 16 August 2017
Resolved
Secure Rule pump in main space bilge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 16 August 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 16 August 2017
Resolved
Modify toilet plumbing to allow single-flush activation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 22 September 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 February 2017
Resolved
Refasten stbd cleating of collision bulkhead.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Cleating refastened.
Construction/Loadline › Hull › Stiffener
Issued 14 February 2017
Resolved
Replace wood spacers between frames under port side of collision bulkhead.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Wood spacers replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 February 2017
Resolved
Make collision bulkhead watertight.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Collision bulkhead watertight.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2017
Resolved
Reglass FRP overlay as marked.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: FRP overlay reglassed as marked.
Operations/Management › Vessel Activity › Underway
Issued 14 February 2017
Resolved
Complete post drydock checkride.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Checkride completed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 17 August 2016
Resolved
Prior to operating with passengers, haul vessel and make available for assessment and structural repairs to address port & stbd movement of longitudinal sideshell stringers and weeping. Por tside exhibits excessive hull flexing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2016
Resolved 26 August 2016
Resolution: Hull repairs completed as approved and completed satisfactory sea trial.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 17 August 2016
Resolved
Replace box for distress signals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 19 September 2016
Resolution: New flare box on board.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 August 2016
Resolved
Renew FCC Radiotelephony Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 19 September 2016
Resolution: Received new FCC safety radio cert., expires 9/15/2021.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 17 August 2016
Resolved
Provide current chem testign crew list.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 1 September 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 August 2016
Resolved
Replace stbd sidelight lens
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 26 August 2016
Resolution: Stbd light tested sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 August 2016
Resolved
Replace waterlight battery prior to operating after dark.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 26 August 2016
Communications › Radio Communications › EPIRB
Issued 17 August 2016
Resolved
Replace EPIRB hydro release NLT 01SEP16.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 1 September 2016