SEA TREK

SEA TREK is a 1956 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in October 2025, along with 49 deficiencies, 1 operational control and 4 casualty investigations between 2017 and 2023.

Records from 2016 to 2025. Most recent: inspection, 7 October 2025.

Built
1956
Last inspected
7 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 October 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM 4787
Flag
UNITED STATES
Maury page id
psix-43185

Documentation record

Registered dimensions (L × B × D)53.1 ft × 18.0 ft × 4.7 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA BOAT COMPANY · COSTA MESA, CA, UNITED STATES · built 1956
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMARINA DEL REY, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 21 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ELECTRA Passenger (Inspected) · MISLE 44762 · 21 August 2017 · activity 6247977

Inspection history · 27

7 October 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8157498
10 January 2025 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8031531
2 October 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7897153
1 September 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7703821
4 August 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7760153
4 August 2023 Deficiency Check · Examination of Repairs · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7760512
4 August 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7762834
31 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7757423
29 July 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7762546
28 June 2023 Internal Structural Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7687071
3 October 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7449465
29 July 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7271801
15 July 2021 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7249893
27 May 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7208727
15 December 2020 Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7112098
12 December 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7120061
2 April 2020 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6933354
21 October 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6838977
9 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6830914
26 July 2019 Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6763325
8 July 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6742072
27 June 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6457622
21 August 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6247977
20 August 2017 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6248384
1 August 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6226304
27 June 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6183773
11 July 2016 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5939547

Deficiency record · 49

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 October 2025 Resolved
For fixed-gas fire extinguishing systems the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel missing fixed-gas fire extinguishing servicing certificate. Provide satisfactory servicing report to MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2025
Resolved 9 October 2025
Resolution: Servicing conducted by Pacific Fire & Marine
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 October 2025 Resolved
Exhaust gas must not leak from the piping or any connections. MI observed 1/2" hole in port engine exhaust dry piping located 6" forward of wet exhaust piping. Submit repair proposal prior to conducting repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2025
Resolution: Repaired by a certified wielder.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 October 2025 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. MI observed a 12"x8" penetration in bulkhead between lazarette room to the engine room; make vapor tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 October 2025
Resolution: Sealed bulkhead penetrations with marine grade plywood.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Vessel missing fuel shutoff valves at the engine end of the fuel line for both MDEs and generator.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 7 October 2024
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 2 October 2024 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Wire penetrations in vapor barrier of fwd engine room bulkhead are not vapor tight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 7 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 October 2024 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry - Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. 03 orange smoke distress signals expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 7 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 September 2023 Resolved
Ring Life Buoys. During inspection, grabline and body of ring life buoy was deteriorated. Repair or replace as needed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2023
Resolution: Operator provided receipt for ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 September 2023 Resolved
Distress signals. During inspection, vessel found with 4 red and 3 orange distress signals current, and 4 red, 3 orange expired (OCT, NOV 2022 respectively). Vessel L/C route requires 6 of each (or 12 total acceptable day/night signals).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2023
Resolution: Operator provided receipt for 3 "Locate HH Rd" and 3 "Smoke HH Orange."
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 September 2023 Resolved
Nav lights and day shapes. During inspection, vessel stern light found to have 180-225' arc of visibility, vice 135' arc of visibiilty. Repair or replace stern light with appropriate lighting.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 26 September 2023
Resolution: Operator provided statement of replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. During def check, vessel unable to shift stbd MDE into forward or reverse to conduct sea trial.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 September 2023
Resolved 1 September 2023
Resolution: Operator replaced hydraulic shift box with new unit, and produced old parts which had a broken plunger spring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2023 Resolved
Fuel piping materials and workmanship. During fuel service system follow up, operator reported broken generator fuel return line. During operation of MDEs, generator return cannot be isolated from MDE returns and leaks fuel. Make repairs to generator manufacturer acceptable standard on generator fuel line returns.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 August 2023
Resolution: Witnessed generator fuel return line and fuel pump operating under load with no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 August 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessels STBD Main Diesel engine is not operating as required.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 August 2023
Resolution: STBD fuel tank valve replaced. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2023 Resolved
Fuel oil service system. Shutoff valves installed so as to close against the fuel flow, must be fitted in the fuel supply lines. During deficiency check, stbd fuel shutoff found slight cracked open and was cycled but did not appear to fully close. Make repairs to the shut off valve acceptable to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 4 August 2023
Resolved 16 August 2023
Resolution: Witnessed stbd fuel shut off in fully closed position. Operator had replaced valve handle and appeared to allow further travel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessels Port Main Diesel engine is not operating as required.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 August 2023
Resolved 3 August 2023
Resolution: [name withheld] to Proper Repair. All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 July 2023 Resolved
The height of top rails required by paragraph (a) of this section must be as follows:Rails on passenger decks of a ferry or a vessel engaged in excursion trips, including but not limited to sightseeing trips, dinner and party cruises, and overnight cruises, must be at least 1,000 millimeters (39.5 inches) high. Vessel hand rails do not meet the required 39.5 inches.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 1 September 2023
Resolution: Operator installed higher aluminum 1.25" hand rail and stanchions on top of existing bulwark rails.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2022 Resolved
At least one ring life buoy must be ftted with a lifeline. Each lifeline on a ring life buoy must be of a least 60 ft in length.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 11 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2022 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3ft in length, but not more than 6ft , securing the waterlight around the body of the ring life buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 11 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 October 2022 Resolved
All cables and wire must: Be installed with metal supports spaced not more than 24 inches apart, in a manner as to avoid chafing and other damage. Vessel wiring within the engine room was not properly supported.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 17 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2022 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 F, must be suitably insulated where necessary to prevent injuries. Vessel turbocharger was missing proper insulation wrapping on piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 17 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 October 2022 Resolved
On passenger decks of vessels engaged in a excursion type operation, rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. Vessel rail height was below required. Must submit plans on how and when (next drydock time) the vessel will come into rail height compliance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 November 2022
Resolved 1 September 2023
Resolution: Operator worked with MIs and provided plan for hand railings, witnessed sat hand rail installation this day. Photo uploaded.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 October 2022 Resolved
Main distribution panels shall be of the dead front type. Wheelhouse sub-panel was missing a blank. 46 CFR 183.10-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 11 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 3 October 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel vent closure flaps for engine room and generator bulkhead were not able to fully close creating a weathertight space. 46 CFR 182.465 (h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 17 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 December 2020 Resolved
VESSELS PORT SHAFT WAS SHEARED OFF APPROX 9" AFT OF PORT MAIN GEAR BOX. VESSEL MUST REPLACE SHAFT AND ENSURE RUDDER AND PROPELLER WERE NOT DAMAGED. Prior to departure the vessel rep must submit a repair plan including location of haul out and request a CG 948 from OCMI
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2021
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 2 April 2020 Resolved
PROVIDE VALID FCC STATION AND FCC SAFETY CERTIFICATES TO THE USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2020
Resolved 10 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2020 Resolved
12 lifejackets needed to change out the retro reflective tape. Corrected on the spot
Action required: 10 - Deficiency Rectified
Due 16 April 2020
Resolved 2 April 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2019 Resolved
Make repairs to port side handrail.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2019
Resolved 9 October 2019
Resolution: Fixed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2019 Resolved
Vessel must complete a satisfactory drydock inspection prior to carrying passengers. 46CFR176.500
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2019
Resolved 16 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2019 Resolved
Replace battery on lifering buoy waterlight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 8 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 June 2018 Resolved
Provide current FCC Safety Certificate
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 June 2018 Resolved
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 June 2018 Resolved
Renew hoses on both electric submersible pumps in storage room
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 27 June 2018 Resolved
Properly service the EPIRB or renew
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2018
Resolution: EPIRB Properly serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 27 June 2018 Resolved
Label port and starboard fuel fills
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2018 Resolved
Repair hydraulic leak on steering resevoir
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
Operations/Management › Vessel Activity › Underway
Issued 21 August 2017 Resolved
Prove proper operation of the vessels propulsion system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2017
Resolution: Engines tested, unable to replicate reported condition.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 August 2017 Resolved
Make repairs to the port quarter deck rail.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2017
Resolution: Repairs made to deck railing.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 August 2017 Resolved
Provide valid FCC radio station license and safety radiotelephony certificate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 8 August 2017
Resolution: FCC radio station onboard and valid
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 August 2017 Resolved
Conduct underway emergency drilll to include MOB and fire drills.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: Got vessel underway and conducted MOB and fire drills.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 August 2017 Resolved
Prove proper operation of masthead light and all around white light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 August 2017
Resolution: Proved proper operation of navigation lights.
Electrical › Electrical Distribution System (service) › Conductor
Issued 1 August 2017 Resolved
Remove electrical hazard in the pilothouse panelboard. Missing blank/breaker
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 11 August 2017
Resolution: Electrical hazard eliminated.
Electrical › Electric Generation Source (service) › Panelboard
Issued 1 August 2017 Resolved
Install proper meters for A/C generator more than 50 volts; voltmeter, ammeter, hertz
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 26 January 2018
Resolution: Gauges installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 1 August 2017 Resolved
Prove proper operation of the portside main engine. The engine fails to start up after shutdown and switch to the fireboy override feature
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: Portside main engine fully functional.
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2017 Resolved
REPAIR SPLIT PLANK ON STBD SIDE
Action required: 705 - Other - as specified
Resolved 7 July 2017
Resolution: repaired
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2017 Resolved
RE CAULK GARBOR PLANK ON STBD SIDE
Action required: 705 - Other - as specified
Resolved 7 July 2017
Resolution: Repaired
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2017 Resolved
REMOVE SPLASH ZONE ON PORT CHINE AND REPAIR AS NECESSARY
Action required: 705 - Other - as specified
Resolved 7 July 2017
Resolution: Repaired
Engineering › Fuel Oil Service System › Valve
Issued 11 July 2016 Resolved
Properly attach closure device to emergency fuel cutout valves for both main engines
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 30 September 2016
Resolution: Closure devices for the cut out valves were attached.
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 July 2016 Resolved
Provide current navigation publications onboard. (Coast Pilot, Light list, Nav Rules.)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 30 September 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 July 2016 Resolved
Post emergency instruction list
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 30 September 2016
Documentation › Certificates/Documents › Permit, Other
Issued 11 July 2016 Resolved
Provide marine radio operators permit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 30 September 2016

Casualty record · 4

21 August 2017Routine · role: Involved in a Marine Casualty · activity 6247977
12 December 2020Routine · role: Involved in a Marine Casualty · activity 7120061
29 July 2023Routine · role: Involved in a Marine Casualty · activity 7762546
4 August 2023Routine · role: Involved in a Marine Casualty · activity 7762834
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record