MAURY USCG vessel records Sign in
← All vessels

SEA TREK

SEA TREK is a 1956 passenger vessel (inspected). The Coast Guard has recorded 98 inspections since 1985, most recently in October 2025, along with 219 deficiencies, 1 operational control and 4 casualty investigations between 2017 and 2023.

Records from 1985 to 2025. Most recent: inspection, 7 October 2025.

Built
1956
Last inspected
7 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM 4787
Flag
UNITED STATES
368209780
Maury page id
psix-43185

Inspections, by type

…with no type recorded16
Years with a record 38 calendar years (1985–2025)
The 98 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.1 ft × 18.0 ft × 4.7 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA BOAT COMPANY · COSTA MESA, CA, UNITED STATES · built 1956
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMARINA DEL REY, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 21 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM4787MMSI 368209780 · active · compulsorily equipped · granted 13 July 2021, expires 13 July 2031
WG8914MMSI 367171720 · expired · compulsorily equipped · granted 8 March 2007, cancelled 5 August 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ELECTRA Passenger (Inspected) · MISLE 44762 · 21 August 2017 · activity 6247977

Inspection history · 98

7 October 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8157498
10 January 2025 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8031531
2 October 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7897153
1 September 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7703821
4 August 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7760153
4 August 2023 Deficiency Check · Examination of Repairs · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7760512
4 August 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7762834
31 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7757423
29 July 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7762546
28 June 2023 Internal Structural Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7687071
3 October 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7449465
29 July 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7271801
15 July 2021 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7249893
27 May 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7208727
15 December 2020 Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7112098
12 December 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7120061
2 April 2020 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6933354
21 October 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6838977
9 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6830914
26 July 2019 Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6763325
8 July 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6742072
27 June 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6457622
21 August 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6247977
20 August 2017 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6248384
1 August 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6226304
27 June 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6183773
11 July 2016 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5939547
2 October 2015 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5735996
20 July 2012 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4360329
10 July 2012 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4374350
19 August 2011 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4120519
10 August 2011 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4111541
8 May 2009 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3470578
13 April 2009 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3451809
21 January 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3342306
1 April 2008 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3175371
7 May 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2920112
9 April 2007 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2890571
20 April 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2616484
22 April 2005 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2338738
4 April 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2305903
29 April 2004 Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2048312
31 March 2004 Construction Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2034607
30 November 2003 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1956460
29 November 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1962573
5 June 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1810251
2 April 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1767263
2 July 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1637965
18 June 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1630486
6 March 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1494145
11 August 2001 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473214
7 June 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1406945
15 May 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 167056
5 April 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1401530
2 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1435233
29 March 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1459580
4 June 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1401001
18 March 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375684
5 March 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 801010
30 October 1998 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 804038
8 July 1998 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 793671
10 June 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 794282
1 May 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1368732
2 April 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1400537
5 December 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1374809
7 August 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1258266
3 April 1996 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1377743
1 June 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 879927
28 April 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1357166
28 March 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1357087
5 April 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1367004
3 November 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1370728
24 March 1993 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1133630
30 April 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 961448
30 March 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 953854
25 March 1992 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 948184
1 April 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1221662
28 March 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 909160
22 January 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 907811
18 January 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 917776
9 November 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1216822
5 April 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 911934
27 March 1990 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 925030
27 April 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1041154
25 April 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1346312
29 March 1989 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 887168
2 May 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1036009
11 April 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1032074
29 March 1988 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1300038
13 November 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1024251
17 June 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1311040
17 June 1987 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1311044
14 April 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1311035
7 April 1987 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1327437
18 June 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1295803
27 March 1986 Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1302890
12 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 980863
29 March 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1288016

Deficiency record · 219

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 October 2025 Resolved
For fixed-gas fire extinguishing systems the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel missing fixed-gas fire extinguishing servicing certificate. Provide satisfactory servicing report to MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2025
Resolved 9 October 2025
Resolution: Servicing conducted by Pacific Fire & Marine
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 October 2025 Resolved
Exhaust gas must not leak from the piping or any connections. MI observed 1/2" hole in port engine exhaust dry piping located 6" forward of wet exhaust piping. Submit repair proposal prior to conducting repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2025
Resolution: Repaired by a certified wielder.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 October 2025 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. MI observed a 12"x8" penetration in bulkhead between lazarette room to the engine room; make vapor tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 October 2025
Resolution: Sealed bulkhead penetrations with marine grade plywood.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Vessel missing fuel shutoff valves at the engine end of the fuel line for both MDEs and generator.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 7 October 2024
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 2 October 2024 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Wire penetrations in vapor barrier of fwd engine room bulkhead are not vapor tight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 7 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 October 2024 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry - Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. 03 orange smoke distress signals expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 7 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 September 2023 Resolved
Ring Life Buoys. During inspection, grabline and body of ring life buoy was deteriorated. Repair or replace as needed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2023
Resolution: Operator provided receipt for ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 September 2023 Resolved
Distress signals. During inspection, vessel found with 4 red and 3 orange distress signals current, and 4 red, 3 orange expired (OCT, NOV 2022 respectively). Vessel L/C route requires 6 of each (or 12 total acceptable day/night signals).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2023
Resolution: Operator provided receipt for 3 "Locate HH Rd" and 3 "Smoke HH Orange."
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 September 2023 Resolved
Nav lights and day shapes. During inspection, vessel stern light found to have 180-225' arc of visibility, vice 135' arc of visibiilty. Repair or replace stern light with appropriate lighting.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 26 September 2023
Resolution: Operator provided statement of replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. During def check, vessel unable to shift stbd MDE into forward or reverse to conduct sea trial.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 September 2023
Resolved 1 September 2023
Resolution: Operator replaced hydraulic shift box with new unit, and produced old parts which had a broken plunger spring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2023 Resolved
Fuel piping materials and workmanship. During fuel service system follow up, operator reported broken generator fuel return line. During operation of MDEs, generator return cannot be isolated from MDE returns and leaks fuel. Make repairs to generator manufacturer acceptable standard on generator fuel line returns.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 August 2023
Resolution: Witnessed generator fuel return line and fuel pump operating under load with no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 August 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessels STBD Main Diesel engine is not operating as required.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 August 2023
Resolution: STBD fuel tank valve replaced. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2023 Resolved
Fuel oil service system. Shutoff valves installed so as to close against the fuel flow, must be fitted in the fuel supply lines. During deficiency check, stbd fuel shutoff found slight cracked open and was cycled but did not appear to fully close. Make repairs to the shut off valve acceptable to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 4 August 2023
Resolved 16 August 2023
Resolution: Witnessed stbd fuel shut off in fully closed position. Operator had replaced valve handle and appeared to allow further travel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessels Port Main Diesel engine is not operating as required.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 August 2023
Resolved 3 August 2023
Resolution: [name withheld] to Proper Repair. All Sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 July 2023 Resolved
The height of top rails required by paragraph (a) of this section must be as follows:Rails on passenger decks of a ferry or a vessel engaged in excursion trips, including but not limited to sightseeing trips, dinner and party cruises, and overnight cruises, must be at least 1,000 millimeters (39.5 inches) high. Vessel hand rails do not meet the required 39.5 inches.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 1 September 2023
Resolution: Operator installed higher aluminum 1.25" hand rail and stanchions on top of existing bulwark rails.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2022 Resolved
At least one ring life buoy must be ftted with a lifeline. Each lifeline on a ring life buoy must be of a least 60 ft in length.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 11 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2022 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3ft in length, but not more than 6ft , securing the waterlight around the body of the ring life buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 11 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 October 2022 Resolved
All cables and wire must: Be installed with metal supports spaced not more than 24 inches apart, in a manner as to avoid chafing and other damage. Vessel wiring within the engine room was not properly supported.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 17 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2022 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 F, must be suitably insulated where necessary to prevent injuries. Vessel turbocharger was missing proper insulation wrapping on piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 17 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 October 2022 Resolved
On passenger decks of vessels engaged in a excursion type operation, rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. Vessel rail height was below required. Must submit plans on how and when (next drydock time) the vessel will come into rail height compliance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 November 2022
Resolved 1 September 2023
Resolution: Operator worked with MIs and provided plan for hand railings, witnessed sat hand rail installation this day. Photo uploaded.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 October 2022 Resolved
Main distribution panels shall be of the dead front type. Wheelhouse sub-panel was missing a blank. 46 CFR 183.10-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 11 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 3 October 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel vent closure flaps for engine room and generator bulkhead were not able to fully close creating a weathertight space. 46 CFR 182.465 (h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 17 October 2022
Resolution: Vessel submitted satisfactory proof or repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 December 2020 Resolved
VESSELS PORT SHAFT WAS SHEARED OFF APPROX 9" AFT OF PORT MAIN GEAR BOX. VESSEL MUST REPLACE SHAFT AND ENSURE RUDDER AND PROPELLER WERE NOT DAMAGED. Prior to departure the vessel rep must submit a repair plan including location of haul out and request a CG 948 from OCMI
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2021
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 2 April 2020 Resolved
PROVIDE VALID FCC STATION AND FCC SAFETY CERTIFICATES TO THE USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2020
Resolved 10 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2020 Resolved
12 lifejackets needed to change out the retro reflective tape. Corrected on the spot
Action required: 10 - Deficiency Rectified
Due 16 April 2020
Resolved 2 April 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2019 Resolved
Make repairs to port side handrail.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2019
Resolved 9 October 2019
Resolution: Fixed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2019 Resolved
Vessel must complete a satisfactory drydock inspection prior to carrying passengers. 46CFR176.500
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2019
Resolved 16 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2019 Resolved
Replace battery on lifering buoy waterlight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 8 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 June 2018 Resolved
Provide current FCC Safety Certificate
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 June 2018 Resolved
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 June 2018 Resolved
Renew hoses on both electric submersible pumps in storage room
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 27 June 2018 Resolved
Properly service the EPIRB or renew
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2018
Resolution: EPIRB Properly serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 27 June 2018 Resolved
Label port and starboard fuel fills
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2018 Resolved
Repair hydraulic leak on steering resevoir
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2018
Resolved 30 July 2018
Operations/Management › Vessel Activity › Underway
Issued 21 August 2017 Resolved
Prove proper operation of the vessels propulsion system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2017
Resolution: Engines tested, unable to replicate reported condition.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 August 2017 Resolved
Make repairs to the port quarter deck rail.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2017
Resolution: Repairs made to deck railing.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 August 2017 Resolved
Provide valid FCC radio station license and safety radiotelephony certificate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 8 August 2017
Resolution: FCC radio station onboard and valid
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 August 2017 Resolved
Conduct underway emergency drilll to include MOB and fire drills.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: Got vessel underway and conducted MOB and fire drills.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 August 2017 Resolved
Prove proper operation of masthead light and all around white light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 August 2017
Resolution: Proved proper operation of navigation lights.
Electrical › Electrical Distribution System (service) › Conductor
Issued 1 August 2017 Resolved
Remove electrical hazard in the pilothouse panelboard. Missing blank/breaker
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 11 August 2017
Resolution: Electrical hazard eliminated.
Electrical › Electric Generation Source (service) › Panelboard
Issued 1 August 2017 Resolved
Install proper meters for A/C generator more than 50 volts; voltmeter, ammeter, hertz
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 26 January 2018
Resolution: Gauges installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 1 August 2017 Resolved
Prove proper operation of the portside main engine. The engine fails to start up after shutdown and switch to the fireboy override feature
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: Portside main engine fully functional.
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2017 Resolved
REPAIR SPLIT PLANK ON STBD SIDE
Action required: 705 - Other - as specified
Resolved 7 July 2017
Resolution: repaired
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2017 Resolved
RE CAULK GARBOR PLANK ON STBD SIDE
Action required: 705 - Other - as specified
Resolved 7 July 2017
Resolution: Repaired
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2017 Resolved
REMOVE SPLASH ZONE ON PORT CHINE AND REPAIR AS NECESSARY
Action required: 705 - Other - as specified
Resolved 7 July 2017
Resolution: Repaired
Engineering › Fuel Oil Service System › Valve
Issued 11 July 2016 Resolved
Properly attach closure device to emergency fuel cutout valves for both main engines
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 30 September 2016
Resolution: Closure devices for the cut out valves were attached.
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 July 2016 Resolved
Provide current navigation publications onboard. (Coast Pilot, Light list, Nav Rules.)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 30 September 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 July 2016 Resolved
Post emergency instruction list
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 30 September 2016
Documentation › Certificates/Documents › Permit, Other
Issued 11 July 2016 Resolved
Provide marine radio operators permit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 30 September 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 2 October 2015 Resolved
Make repairs to starboard main engine transmission prior to carrying passengers.
Action required: 705 - Other - as specified
Due 12 October 2015
Resolved 23 October 2015
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 July 2012 Resolved
Ensure generator will shut down when fireboy system activates.
Condition: Improper/Lack of Maintenance
Due 20 July 2012
Resolved 20 July 2012
Resolution: Proved generator will shutdown with fireboy system.
Stability › Unintentional Flooding › General
Issued 10 July 2012 Resolved
Vessel has a leak on the portside midship area in way of the hard chine. Vessel is not to carry psgrs until leak is fixed to the satisfaction of the attending CG [name withheld] to be repaired needs to be 100% identified prior to hauling out. Vsl needs to be hauled out for proper survey by CG [name withheld] may proceed to D/D, but needs to contact Sector SD & Sector LA/LB before depart & on arrival.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2012
Resolved 16 July 2012
Resolution: Damage on portside of vessel repaired
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 August 2011 Resolved
Operator of vessel failed to maked vessel available for Annual Inspection within 3 months of COI anniversary date (26APR).
Action required: 705 - Other - as specified
Due 10 August 2011
Resolved 11 August 2011
Construction/Loadline › Hull › Hull Plating
Issued 8 May 2009 Resolved
Issued 835 on report and investigation that the M/V SEA TREK conducted Hull repairs underwater without notifying OCMI. Vessel is restricted from carrying passengers until written plans are submitted and approved. Repairs must be completed to the satisfaction of Officer In Charge Marine Inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 8 May 2009
Operations/Management › Drills/Instruction › Fire
Issued 29 April 2009 Resolved
Not all required drills are being logged.
Due 29 April 2009
Resolved 29 April 2009
Resolution: Conducted verbal MOB & Machinery space fire drill with master and two deck hands, crews knowledge of procedures was excellent.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 13 April 2009 Resolved
Life raft was being serviced and not on board at time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2009
Resolution: Life raft serviced, onboard, and inspected by CGMI.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 April 2009 Resolved
Alcohol testing devices were expired.
Due 29 May 2009
Resolved 21 May 2009
Resolution: New strips expire Dec. 2009
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 13 April 2009 Resolved
First aid kit hade expired medication.
Due 29 May 2009
Resolved 1 May 2009
Resolution: Up to date medication onboard.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 April 2009 Resolved
SPV decal was not on board/posted IAW 46 CFR 176.310
Due 29 May 2009
Resolved 1 May 2009
Resolution: New sticker provided to Vsl by CGMI.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 April 2008 Resolved
Add 30 feet of non-kinking floatable line to make 60 feet total.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 30 April 2008
Electrical › Electric Supply System (service) › Cable
Issued 23 April 2008 Resolved
Repair/replace worn (cover) battery cab le.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 30 April 2008
Engineering › Fuel Oil Service System › Filter
Issued 23 April 2008 Resolved
Provide plug for Racor fuel strainer bonnet in generator space.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 30 April 2008
Documentation › Certificates/Documents › Stability Letter
Issued 23 April 2008 Resolved
Post all pages of stability letter at operating station visible to operator.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 30 April 2008
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 23 April 2008 Resolved
Provide lagging on generator exhaust where missing.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 30 April 2008
Lifesaving › Inflatable Liferafts › Servicing
Issued 1 April 2008 Resolved
Provide serviced 50 person liferaft for certificated number of persons. Vessel restricted to 25 persons until corrected.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 2 May 2008
Navigation › Piloting/Steering › Marine Charts
Issued 7 May 2007 Resolved
Provide a chart of the operating area.
Due 20 May 2007
Resolved 15 October 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 May 2007 Resolved
Provide a tidal current.
Due 20 May 2007
Resolved 28 August 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 7 May 2007 Resolved
Install flaps for ventilation into generator compartment.
Due 20 May 2007
Resolved 28 August 2007
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 7 May 2007 Resolved
Provide sturdy embarkation ladder
Due 20 May 2007
Resolved 28 August 2007
Documentation › Markings/Placards › Oil Discharge Placard
Issued 7 May 2007 Resolved
Provide a no discharge placard for oil pollution.
Due 20 May 2007
Resolved 28 August 2007
Construction/Loadline › Hull › Hull Plating
Issued 9 April 2007 Resolved
Re-caulk IWO of stbd side keel, stbd side above chine, stem area, port side under chine, and all areas identified and marked.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 19 April 2007
Construction/Loadline › Hull › Hull Plating
Issued 9 April 2007 Resolved
Affect permanent repair to loose planks (2) at stbd side aft quarter (10th plank outboard from keel, and 1st plank above chine).
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 19 April 2007
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 9 April 2007 Resolved
Replace gasket seal on forepeak hatch.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 19 April 2007
Construction/Loadline › Hull › Transverse Frame
Issued 9 April 2007 Resolved
Affect permanent repair to decayed areas in forepeak and void #2.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 19 April 2007
Construction/Loadline › Hull › Transverse Frame
Issued 9 April 2007 Resolved
Affect permanent repair to bottom of frame #1 in void #2 stbd side.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 19 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 April 2007 Resolved
Remove dead-end wires in void #4 (under galley).
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 19 April 2007
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 9 April 2007 Resolved
Ensure galley grease extraction hood meets CID Policy Letter #20 prior to 9Oct07.
Action required: 705 - Other - as specified
Due 9 October 2007
Resolved 15 October 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2006 Resolved
Clean up and remove unapproved wiring in bilge space under heads.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 8 May 2006
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 April 2006 Resolved
Fill dead spaces in distribution box in generator space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 8 May 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 20 April 2006 Resolved
Service fire extinguisher in pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 8 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 April 2006 Resolved
Re-locate and stencil location of child size life jackets. Jackets were placed with adult life jackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 8 May 2006
Lifesaving › Work Vest › Readily Accessible
Issued 20 April 2006 Resolved
Replace Type I rescue swimmer life jacket with a more workable lifejacket and make readily accessible to crew.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 8 May 2006
Stability › Weathertight Integrity › General
Issued 20 April 2006 Resolved
Repair / replace dogs on head space port hole.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 8 May 2006
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 22 April 2005 Resolved
Ensure vessel name and hailing port is marked on the stern of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2005
Resolved 27 April 2005
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 22 April 2005 Resolved
Port fuel tank has small fracture around pipe assembly. Submit repair proposal for port fuel tank to include fuel shutoff assembly. Repair as necessary.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 April 2005
Resolved 27 April 2005
Resolution: Port fuel tank leak was due to loose fitting. Upon taking valve assembly off, operator found that piping was loose.
Engineering › Steering Gear System › Rudder Stock
Issued 22 April 2005 Resolved
Starboard rudder stock has movement when full port and full starboard. Submit repair proposal for starboard rudder stock. Wood in surrounding area is showing signs of wastage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 April 2005
Resolved 27 April 2005
Construction/Loadline › Hull › Bottom Plating
Issued 4 April 2005 Resolved
Check all engine room stringer fasteners and replace as necessary. Inspectors were able to pull fastener out of stringer due to wastage. Vsl operator instructed to check and replace all wasted fasteners.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2005
Resolved 20 April 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 April 2005 Resolved
Properly mount fire extinguisher in forward compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2005
Resolved 22 April 2005
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 April 2004 Resolved
Install machinery guard over bilge pump. LEGACY COMPONENT DESC: Belts
Due 29 May 2004
Resolved 6 May 2004
Electrical › Electric Supply System (service)
Issued 29 April 2004 Resolved
Install insulated boots on batt. terminals on bridge. LEGACY COMPONENT DESC: Battery Terminals
Due 29 May 2004
Resolved 6 May 2004
Construction/Loadline › Penetrations
Issued 29 April 2004 Resolved
Pack all penetrations through watertight bulkheads. LEGACY COMPONENT DESC: Bulkhead pens.
Due 29 May 2004
Resolved 6 May 2004
Pollution Prevention/Response › Prevention Equipment
Issued 29 April 2004 Resolved
Mount MSD tank to vessel. LEGACY COMPONENT DESC: Marine Sanitation Device, Type 1
Due 29 May 2004
Resolved 6 May 2004
Construction/Loadline › Structures
Issued 29 April 2004 Resolved
Mount potable water tank to vessel. LEGACY COMPONENT DESC: H2O tank
Due 29 May 2004
Resolved 6 May 2004
Navigation › Collision/Grounding Avoidance
Issued 29 April 2004 Resolved
Provide new Coast Pilot Manual. LEGACY COMPONENT DESC: Coast Pilot Manual
Due 29 May 2004
Resolved 6 May 2004
Communications › Radio Communications
Issued 29 April 2004 Resolved
Provide valid FCC Safety Radio Cert. LEGACY COMPONENT DESC: Safety Radio Cert.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2004
Engineering › Fuel Oil Service System
Issued 29 April 2004 Resolved
Make emergy fuel stops operable. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2004
Engineering › Steering Gear System
Issued 29 April 2004 Resolved
Provide repair proposal for repair of steering system. System is improperly mounted and transmitting motion to the structural members. LEGACY COMPONENT DESC: Structural
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2004
Resolution: Steering was properly attached to the hull of the vessel and transmits power to the rudder rather than structural members. The owner reinforced the transom and deck framing.
Electrical › Electric Supply System (service)
Issued 29 April 2004 Resolved
Shore tie cable cracked and damaged along its' entire length, renew. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 14 May 2004
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 30 November 2003 Resolved
Prior to carrying passengers, prove proper operation of steering/propulsion system to the satisfaction of an attending marine inspector. LEGACY COMPONENT DESC: Notice of Marine Casualty
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2003
Resolved 6 May 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 June 2003 Resolved
Replace retro tape on eight life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2003
Resolution: Jackets were replace while we were onboard.
Electrical › Lighting (service)
Issued 5 June 2003 Resolved
Replace lighting fixtures in galley with approved fixtures LEGACY COMPONENT DESC: Lighting Fixture
Condition: Placed in Improper Service
Due 20 June 2003
Resolved 20 June 2003
Electrical › Electric Supply System (service)
Issued 5 June 2003 Resolved
Remove dead ended wires in pilot house next to power panel, on top of generator and outboard starb side of generator. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 20 June 2003
Resolved 20 June 2003
Electrical › Electric Supply System (service)
Issued 5 June 2003 Resolved
Label breakers in power panels in pilot house and galley. LEGACY COMPONENT DESC: Power Panel
Condition: Improper Installation
Due 20 June 2003
Resolved 20 June 2003
Engineering › Freshwater System (intermediary cooling)
Issued 5 June 2003 Resolved
Replace hose on sea suction to generator cooling. LEGACY COMPONENT DESC: Hose
Due 20 June 2003
Resolved 20 June 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 June 2003 Resolved
Replace lagging on port and starb main engine exhaust elbows. Elbows are being used as steps to get into engine room. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Placed in Improper Service
Due 20 June 2003
Resolved 20 June 2003
Electrical › Electric Supply System (service)
Issued 5 June 2003 Resolved
Install box connector on light switch starb side of engine room. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 20 June 2003
Resolved 20 June 2003
Communications › Alarms/Indicators
Issued 5 June 2003 Resolved
Provide operable bilge alarms. Log testing of alarms prior to getting underway. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2003
Resolved 8 June 2003
Resolution: Bilge alarms were made operable while we were conduction inspection. However, it is obvious that trips were made without operable bilge alarms.
Stability › Watertight Integrity
Issued 5 June 2003 Resolved
Remove or plug unused pipe under galley that enters engine room. LEGACY COMPONENT DESC: Piping
Due 20 June 2003
Resolved 20 June 2003
Electrical › Electric Supply System (service)
Issued 5 June 2003 Resolved
Repair conduit carrying cables under galley deck. LEGACY COMPONENT DESC: Cable
Condition: Damaged By Earlier Event
Due 20 June 2003
Resolved 20 June 2003
Deck/Cargo › Holds/Tanks
Issued 5 June 2003 Resolved
Attach captive chain to laz. deck hatch. LEGACY COMPONENT DESC: Hatch
Condition: Improper/Lack of Maintenance
Due 20 June 2003
Resolved 20 June 2003
Operations/Management › Drills/Instruction
Issued 5 June 2003 Resolved
Conduct and log required drills to the satisfation of attending USCG marine inspector. Two liscensed masters were onboard for inspection, both have been hired within days of inspection. No one onboard acting as crew had done required drills. Drills have not been logged. Conducted extensive trainin LEGACY COMPONENT DESC: Safety Orientation
Due 20 June 2003
Resolved 20 June 2003
Resolution: Logbook updated and drills satisfactorily performed
Electrical › Electric Supply System (service)
Issued 5 June 2003 Resolved
Secure battery box to deck of pilot house. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Due 20 June 2003
Resolved 20 June 2003
Engineering › Fuel Oil Service System
Issued 5 June 2003 Resolved
Install 30 X 30 mesh screen in fuel tank vents. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper Installation
Due 20 June 2003
Resolved 20 June 2003
Fire Fighting › Remote Fuel Shutoff
Issued 5 June 2003 Resolved
Provide operable emergency fuel shutoff valve on port side tank. Valve handle was broken in half and inoperable from outside the space. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2003
Resolved 6 June 2003
Resolution: A new valve handle was installed while we were onboard. It is obvious that trips were made with valve inoperable.
Construction/Loadline › Structures
Issued 5 June 2003 Resolved
Secure hand rails to bulwark. The after 1/3 of port side rail was loose. Check intire rails system when clearing def. LEGACY COMPONENT DESC: Hand Rails
Condition: Improper/Lack of Maintenance
Due 20 June 2003
Resolved 20 June 2003
Resolution: Rails secured
Fire Fighting › Ventilation Systems
Issued 5 June 2003 Resolved
Provide method of blocking off ventilation to engine room in the event of fire. LEGACY COMPONENT DESC: Ducts
Condition: Design Flaw
Due 20 June 2003
Resolved 20 June 2003
Resolution: Means were already on-board but the inexperienced crew did not know where they were located
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 June 2003 Resolved
Repair leak on port engine lube oil cooler outboard of engine. LEGACY COMPONENT DESC: Lube Oil Cooler
Condition: Improper/Lack of Maintenance
Due 20 June 2003
Resolved 20 June 2003
Communications › Radio Communications
Issued 13 June 2002 Resolved
Provide valid FCC operators license. LEGACY COMPONENT DESC: FCC Operators License
Due 3 July 2002
Resolved 2 July 2002
Communications › Radio Communications
Issued 13 June 2002 Resolved
Provide emergy broadcast placard. LEGACY COMPONENT DESC: Broadcast Placard
Due 3 July 2002
Resolved 2 July 2002
Electrical › Electric Supply System (service)
Issued 13 June 2002 Resolved
Install cover over 110v receptical on bridge. LEGACY COMPONENT DESC: 110v Receptical
Due 3 July 2002
Resolved 2 July 2002
Lifesaving › Lifebuoys
Issued 13 June 2002 Resolved
Correctly attach float light to ring buoy. LEGACY COMPONENT DESC: Float Light
Due 3 July 2002
Resolved 2 July 2002
Lifesaving › Lifebuoys
Issued 13 June 2002 Resolved
Mark ring buoy with vessel's name. LEGACY COMPONENT DESC: Marking
Due 3 July 2002
Resolved 2 July 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 June 2002 Resolved
Provide one type I childs PFD. LEGACY COMPONENT DESC: Childs
Due 3 July 2002
Resolved 2 July 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 13 June 2002 Resolved
Clean oil leakage from port engine. LEGACY COMPONENT DESC: Excessive oil
Due 3 July 2002
Resolved 2 July 2002
Electrical › Electrical Distribution System (service)
Issued 13 June 2002 Resolved
Remove or use dead ended wireing from aft engine room center. LEGACY COMPONENT DESC: Wiring
Due 3 July 2002
Resolved 2 July 2002
Electrical › Electrical Distribution System (service)
Issued 13 June 2002 Resolved
Install latch on power panel door in aft engine room. LEGACY COMPONENT DESC: Power Panel
Due 3 July 2002
Resolved 2 July 2002
Electrical › Electrical Distribution System (service)
Issued 13 June 2002 Resolved
Rewire washdown pump. LEGACY COMPONENT DESC: Washdown pump
Due 3 July 2002
Resolved 2 July 2002
Engineering › Fuel Oil Service System
Issued 13 June 2002 Resolved
Make starb. emergy stop operable. LEGACY COMPONENT DESC: Emergy Stop.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2002
Construction/Loadline
Issued 11 August 2001 Resolved
Submit repair proposal to [name withheld] for damaged prior to operating with passengers.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Engineering
Issued 11 August 2001 Resolved
Replace port ER engine shutdown spring.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Electrical
Issued 11 August 2001 Resolved
Mount starting switch in port ER near battery.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Engineering
Issued 11 August 2001 Resolved
Effect permanent repairs to the shaft log prior to carrying passengers.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Construction/Loadline
Issued 11 August 2001 Resolved
Demonstrated proper operation of Bilge alarms and machinery to the satisfaction of [name withheld] inspector.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Engineering
Issued 11 August 2001 Resolved
Repair fuel leak at valve on port fuel tank.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Engineering
Issued 11 August 2001 Resolved
Install lagging on the port engine exhaust system.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Construction/Loadline
Issued 11 August 2001 Resolved
Make ER bulkhead vaportight.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Construction/Loadline
Issued 11 August 2001 Resolved
Perform hull repairs to stern of vessel. Repairs are to be completed to the satisfaction of [name withheld] prior to operating with passengers.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Construction/Loadline
Issued 11 August 2001 Resolved
Make ER vaportight.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Engineering
Issued 11 August 2001 Resolved
Replace the engine shutdown spring on port MDE
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Construction/Loadline
Issued 11 August 2001 Resolved
Open port stern QTR for inspection.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Construction/Loadline
Issued 11 August 2001 Resolved
Open STBD stern QTR for inspection.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Electrical
Issued 11 August 2001 Resolved
Install a permanent ground connection on generator shut down solenoid.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Electrical
Issued 11 August 2001 Resolved
Remove dead ended and unused wiring in the engineroom and generator space.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Electrical
Issued 11 August 2001 Resolved
Renew/replace butt spliced wiring above port ER starting battery with unsplice wiring or conductors.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Documentation
Issued 7 June 2001 Resolved
provide annual drug test report.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Electrical
Issued 7 June 2001 Resolved
Provide proper wiring connector for twisted connection in ER.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Engineering
Issued 7 June 2001 Resolved
Provide 30x30 mesh screens for both fuel vents.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Engineering
Issued 7 June 2001 Resolved
provide double hose clamps for salt water hoses on STBD engine.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Engineering
Issued 7 June 2001 Resolved
Renew exhaust lagging on port Main engine.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
Renew FWD hatch cover gasket.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
Renew FWD hatch cover captive chain.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
Repair port engine hatch cover.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Documentation
Issued 7 June 2001 Resolved
Provide waste management plan
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Fire Fighting
Issued 7 June 2001 Resolved
Provide 3 properly labeled FF buckets W/lanyards.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Replace deteriorated reflective material on life jackets.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Provide child sized life jacket.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Engineering
Issued 7 June 2001 Resolved
Provide proper mechanical link for engine solenoid shut downs.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Fire Fighting
Issued 7 June 2001 Resolved
provide proof of proper operation of fixed fire fighting system.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Engineering
Issued 7 June 2001 Resolved
Provide proper label for fuel shut off valve.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Engineering
Issued 7 June 2001 Resolved
Repair STBD engine shut down solenoid.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Navigation
Issued 7 June 2001 Resolved
Provide operable stern light.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Navigation
Issued 7 June 2001 Resolved
Properly mount anchor light.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Replace ring buoy.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Construction/Loadline
Issued 2 February 2001 Resolved
Provide metallic valves and penetrations for PVC piping traversing watertight bulkheads.
Condition: Unknown
Due 1 February 2002
Resolved 21 May 2003
Construction/Loadline
Issued 2 February 2001 Resolved
Provide damage control kit. Kit to be stored in accessible location above the bulkhead deck.
Condition: Unknown
Due 3 July 2001
Resolved 3 July 2001
Navigation
Issued 29 March 2000 Resolved
Provide updated Coast Pilots and Light List by 15APR00.
Condition: Unknown
Due 15 April 2000
Resolved 10 April 2000
Construction/Loadline
Issued 29 March 2000 Resolved
Provide proper bilge alarms for each watertight compartment by 15APR00.
Condition: Unknown
Due 15 April 2000
Resolved 10 April 2000
Lifesaving
Issued 29 March 2000 Resolved
Provide new EPIRB hydrostatic release mechanism prior to carrying passengers beyond three (3) miles.
Condition: Unknown
Due 15 April 2000
Resolved 10 April 2000
Engineering
Issued 1 May 1998 Resolved
PROVIDE 30X30 MESH FOR FUEL TANK VENTS PORT AND STBD
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Electrical
Issued 1 May 1998 Resolved
PROVIDE MEANS OF KEEPING BATTERIES FROM TIPPING OVER.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Documentation
Issued 1 May 1998 Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM INCLUDING ALL CREW MEMBERS
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Electrical
Issued 1 May 1998 Resolved
PROVIDE METALLIC COVER FOR SWITCHBOARD ON BRIDGE
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Electrical
Issued 5 April 1994 Resolved
RENEW/REPLACE GUARD ON COMMUTATOR END OF SHIP SERVICE GENERATOR.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Documentation
Issued 5 April 1994 Resolved
VESSEL REQUIRED TO CONDUCT A SIMPLIFIED STABILITY TEST
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Construction/Loadline
Issued 3 November 1993 Resolved
PULL FASTENERS IN WAY OF PORT AND STBD GARBOARD STRAKES, STBD CHINE, AND PORT CHINE FOR INSPECTION.
Condition: Unknown
Due 3 November 1993
Resolved 3 November 1993
Engineering
Issued 3 November 1993 Resolved
RENEW PORT AND STBD MAIN DIESEL ENGINE EXHAUST SLEEVES IN WAY OF TRANSOM.
Condition: Unknown
Due 3 November 1993
Resolved 3 November 1993
Construction/Loadline
Issued 3 November 1993 Resolved
RENEW STBD OUTER CHINE FROM TRANSOM FORWARD APPROXIMATELY 15 FEET (TO EXISTING SCARF) AND PROPERLY TREAT HULL IN WAY OF WORM DAMAGE.
Condition: Unknown
Due 3 November 1993
Resolved 3 November 1993
Lifesaving
Issued 25 March 1992 Resolved
PROVIDE 4 ADDITIONAL ADULT LIFE JACKETS. TOTAL PERSONS ALLOWED LIMITED TO 45 UNTIL THIS REQUIREMENT CLEARED.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Engineering
Issued 25 March 1992 Resolved
PROVIED FLAME SCREEN AT STARBOARD FUEL TANK VENT.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Electrical
Issued 28 March 1991 Resolved
PROPERLY REPAIR THE SELECTOR SWITCH FOR THE SERVICE GENERATOR AND SHORE_x001C_ POWER.
Condition: Unknown
Due 28 March 1991
Resolved 28 March 1991
Engineering
Issued 28 March 1991 Resolved
PROVIDE A PROPER BILGE SYSTEM INCLUDING THE INSTALLATION OF BILGE PUMP IN _x001C_ACCORDANCE WITH 46CFR182.25-5 AND 46CFR182.25-10(a)(b)(d)(e).
Condition: Unknown
Due 28 March 1991
Resolved 28 March 1991
Engineering
Issued 18 January 1991 Resolved
CONDUCT A SATISFACTORY SEA-TRIAL TO TEST THE PORT MAIN DIESEL ENGINE, SHAFTAND RUDDER PRIOR TO OPERATING WITH PASSENGERS. _x001C_
Condition: Unknown
Due 18 January 1991
Resolved 18 January 1991
Lifesaving
Issued 27 March 1990 Resolved
REPAIR INOPERABLE LIFE FLOAT'S WATER LIGHT.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Engineering
Issued 27 March 1990 Resolved
REPAIR EMERGENCY FUEL OIL SHUT-OFF VALVE FOR THE STARBOARD FUEL OIL TANK.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Navigation
Issued 27 March 1990 Resolved
INSTALL A STERN WHITE LIGHT PLACED AS NEARLY AS PRACTICABLE AT THE STERN SHOWING AN UNBROKEN LIGHT OVER AN ARC OF THE HORIZON OF 135 DEGREES AND SO FIXED AS TO SHOW THE LIGHT 67.5 DEGREES FROM RIGHT AFT ON EACH SIDE OF THE VESSEL. VESSEL IS LIMITED TO DAYLIGHT OPERATION UNTIL STERN LIGHT IS FIXED.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Navigation
Issued 27 March 1990 Resolved
PROVIDE THREE(3) BLACK BALL DAY SHAPES FOR NAVIGATION GROUNDING.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Navigation
Issued 27 March 1990 Resolved
PROVIDE TWO(2) RED LIGHTS FOR NAVIGATION GROUNDING.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Lifesaving
Issued 29 March 1989 Resolved
PROVIDE SIX(6) RED HAND FLARES.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Lifesaving
Issued 29 March 1988 Resolved
PROVIDE A COAST GUARD APPROVED FLOATING ELECTRIC WATER LIGHT ON TWO(2) LIFEFLOATS THAT EMIT FLASHES OF LIGHT AT A FREQUENCY OF NOT LESS THAN 50 NOR MORE THAN 70 FLASHES PER MINUTE FOR A PERIOD OF NOT LESS THAN 15 HOURS.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Construction/Loadline
Issued 29 March 1988 Resolved
INSTALL A PUMP OUT SYSTEM ON DECK TO SHORE FACILITY ON PORT AND STARBOARD MARINE SANITATION DEVICE HOLDING TANKS.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Lifesaving
Issued 29 March 1988 Resolved
PROVIDE SEVEN(7) ADDITIONAL ADULT TYPE I LIFE PRESERVERS. VESSEL IS LIMITEDTO 36 PASSENGERS UNTIL REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Engineering
Issued 7 April 1987 Resolved
REATTACH FUEL SHUTOFF ROD ON STBD FUEL TANK.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Documentation
Issued 7 April 1987 Resolved
PROVIDE UP TO DATE FCC COMMS ACT SAFETY CERTIFICATE.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Navigation
Issued 7 April 1987 Resolved
PROVE PROPER OPERATION OF NAVIGATION LIGHTS.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Navigation
Issued 7 April 1987 Resolved
PROVIDE UPDATED COAST PILOT AND LIGHT LIST.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Lifesaving
Issued 7 April 1987 Resolved
RESTRING TENDING LINE ON RING BUOY.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 7 April 1987 Resolved
PROVIDE 30X30 FLAME SCREEN ON PORT AND STBD FUEL TANK VENTS.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Electrical
Issued 7 April 1987 Resolved
REMOVE ALLUNUSED WIRING,IMPROPER SPLICES AND CONNECTORS,REPLACE WITH PROPER AUTHORIZED MATERIALS.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Documentation
Issued 7 April 1987 Resolved
POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Documentation
Issued 7 April 1987 Resolved
PROVIDE FCC 3RD CLASS RESTRICTED RADIO OPERATORS LICENSE.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Electrical
Issued 7 April 1987 Resolved
PROVIDE RELAY COVER FOR ANCHOR WINDLASS.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Lifesaving
Issued 7 April 1987 Resolved
PROVIDE 2 FLOAT LIGHTS FOR LIFE RAFTS AND 1 ADDITIONAL STENCILED PADDLE.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Lifesaving
Issued 7 April 1987 Resolved
PROVIDE STANTIONS IN LIFERAFT STOWAGE AREA TO PREVENT SHIFTING
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Lifesaving
Issued 7 April 1987 Resolved
PROVIDE 6 ADDITIONAL ADULT PFD.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Fire Fighting
Issued 7 April 1987 Resolved
PROVIDE HAND HELD FIRE PUMP.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Deck/Cargo
Issued 7 April 1987 Resolved
REPLACE AUTOMATIC BILGE PUMP IN MSD COMPARTMENT.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Lifesaving
Issued 7 April 1987 Resolved
PROVIDE STACKING STRIPS BETWEEN LIFEFLOATS.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Navigation
Issued 7 April 1987 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Navigation
Issued 7 April 1987 Resolved
PROVIDE 8 INCH BELL.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Construction/Loadline
Issued 27 March 1986 Resolved
PLUG THRU HULL VALVE PORT FWD OUTBOARD ENGINE COMPARTMENT.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Construction/Loadline
Issued 27 March 1986 Resolved
ATTACH LADDER TO HOUSE TOP SECURELY.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Lifesaving
Issued 27 March 1986 Resolved
STENCIL VESSEL'S NAME ON LIFE RING, LIFEFLOAT PADDLES, AND PFD'S.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Navigation
Issued 27 March 1986 Resolved
SECURE STBD RUDDER FOUNDATION.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Navigation
Issued 27 March 1986 Resolved
TIGHTEN LOOSE BOLT ON HYDRUALIC RAM FOUNDATION.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Electrical
Issued 27 March 1986 Resolved
REPAIR GENERATOR.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Lifesaving
Issued 27 March 1986 Resolved
RENEW LINES ON 12 MAN LIFE FLOAT.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Fire Fighting
Issued 27 March 1986 Resolved
SERVICE B-I FIRE EXTINGUISHER IN WHEEL HOUSE.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Navigation
Issued 27 March 1986 Resolved
RENEW HYD. HOSES ON STEERING GEAR.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Electrical
Issued 27 March 1986 Resolved
REPAIR WIRING IN FWD ACCOMADATION.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986

Casualty record · 4

21 August 2017Routine · role: Involved in a Marine Casualty · activity 6247977
12 December 2020Routine · role: Involved in a Marine Casualty · activity 7120061
29 July 2023Routine · role: Involved in a Marine Casualty · activity 7762546
4 August 2023Routine · role: Involved in a Marine Casualty · activity 7762834
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.