07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 July 2025
No resolution recorded
Was unable to get underway to conduct drills and test all equipment. Therefore, COI inspection is incomplete. Complete a new COI renewal inspection to include underway drills and testing of all equipment.46 CFR 176.404.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 July 2025
No resolution recorded
Vessel’s life-floats were found to be unserviceable and inadequately equipped. Replace the affected life-floats, and equip them in accordance with 46 CFR 180.130, 46 CFR 180.137, 46 CFR 180.175, and 46 CFR 185.604.46 CFR 180.202(a)
46 CFR 180.130
46 CFR 180.137
46 CFR 180.175
46 CFR 185.604.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 July 2025
No resolution recorded
Discovered that the fixed CO2 system in the engine room was past its service date. Have fixed CO2 system serviced.46 CFR 176.810(b).
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 July 2025
No resolution recorded
The galley hood with found with excessive grease build up in, below and behind presenting a fire hazard. Have entire area and galley hood cleaned of all grease build up.
46 CFR 182.100.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 July 2025
No resolution recorded
Observed oil leaking from prime mover of the ship’s generator. Make repairs, as per manufacture’s instruction.46 CFR 182.100.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 July 2025
No resolution recorded
The fire suppression system for the grease extraction hood appeared disconnected with wires disconnected in the wheelhouse panel. Remove obstacles to the panel face, provide third party report attesting to the satisfactory installation of the suppression system.10(b).
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 July 2025
No resolution recorded
Metal was found lodged in the power receptacle. Remove or replace the outlet in wheelhouse on port side.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 July 2025
No resolution recorded
Observed electrical power breakers not at required rating, IAW electrical power distribution list. Vessel is to replace breakers IAW electrical power distribution list.46 CFR 183.380.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 July 2025
No resolution recorded
A junction box in the galley was found cracked and held with tape. Replace the junction box.46 CFR 183.340(g).
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 July 2025
No resolution recorded
Observed various electrical wires that were improperly taped, spliced, and/or dead-ended. Ensure that all splices are placed into an approved junction box or done with an approved pressure type connector.46 CFR 183.340(g).
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 July 2025
No resolution recorded
A bag of rags was found in the battery box in the wheelhouse to prevent the battery movement. Remove combustible materials from battery box and secure batteries for sea.46 CFR 176.830.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 July 2025
No resolution recorded
The vessel did not have proof of enrollment in the random pre-employment drug and alcohol program for anyone onboard. Enroll everyone in a random drug and alcohol program.
Action required: 701 - Prior to carriage of passengers/cargo
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 July 2025
No resolution recorded
Observed bunk room’s high level bilge alarm float switch mounted vertically above the bilge. Install the float switch as low in the bilge as possible.46 CFR 182.530.
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 July 2025
No resolution recorded
Discovered that the electrical fire pump had no guard for the coupling. Install a guard to prevent injuries.46 CFR 182.100.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 July 2025
No resolution recorded
Observed lights that were not functioning and missing protective covers. Verify that all installed lights are working and installed with an approved cover.46 CFR 183.410.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2025
No resolution recorded
Each life jacket must be approved under approval series in subparts 160.002, 160.005, 160.055, 160.115, 160.176, or 160.255. Identified four life jackets that were approved under 160.060. Remove the affected life jackets from the vessel.46 CFR 180.71(c).
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2025
No resolution recorded
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with 161.012. Discovered forty adult life jackets and all child life jackets no or unserviceable life jacket lights.46 CFR 180.75(a).
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2025
No resolution recorded
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. One (01) of the vessel’s ring buoys was found to be unserviceable. Repair/replace the affected ring buoy.46 CFR 180.70(a).
Action required: 701 - Prior to carriage of passengers/cargo
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 July 2025
No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 24 July 2025
No resolution recorded
Vessel did not have records of monthly fire drills. Demonstrate satisfactory drills for attending USCG marine inspectors.6CFR185.524.
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 24 July 2025
No resolution recorded
Vessel did not have records of Abandon Ship or man overboard drills. Demonstrate satisfactory drills for attending USCG marine inspectors, and log as required.46CFR185.520.
Action required: 701 - Prior to carriage of passengers/cargo
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 July 2025
No resolution recorded
Vessel did not have records of EPIRB testing. Conduct monthly testing of EPIRB and log as required.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 24 July 2025
No resolution recorded
Observed both top and bottom flex hoses leaking from sewage tank. Provide a repair plan and receive repair plan approval, prior to making any repairs.46 CFR 182.100.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 July 2025
No resolution recorded
Observed ship’s generator’s box connector not installed. Install an approved box connector.46 CFR 183.340.
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2025
No resolution recorded
Observed both propulsion engine fuel oil (F/O) separators full of sediments. Vessel is to clean each F/O separator and follow manufactures maintenance requirements.46 CFR 182.100.
Action required: 16 - Rectify deficiencies w/in 14 days
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 July 2025
No resolution recorded
The light for the magnetic compass was inoperable. Repair/replace the affected light.46CFR184.402.
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2025
No resolution recorded
At least one ring life buoy must be fitted with a lifeline of at least 60 feet in length. Lifeline on ring buoy was found to be less than 60 feet in length.46 CFR 180.70(c).
Action required: 16 - Rectify deficiencies w/in 14 days
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 24 July 2025
No resolution recorded
Observed side shell pulling away from the futtock in the aft portside bunk room. Provide a repair plan for approval prior to commencing any repairs.46 CFR 185.604(i).
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2025
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. All ring buoys were found to have an insufficient amount of retroreflective material.46 CFR 176.700.
Action required: 10 - Deficiency Rectified
Resolved 24 July 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 May 2025
No resolution recorded
Vessel was discovered to have missed its Annual inspection and operated form 22Feb25 to 08Jun25 on an invalid COI. To maintain a valid COI, the vessel must complete an annual inspection every year within alloted time on COI.
Vessel is restricted from carrying passengers for hire. This is the 3rd time in 3 years vessel has missed its annual inspection.
COI has been revoked.
COI exam scheduled for 15Jul2025.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 August 2024
Resolved
Vessel experienced separation and delamination to the port side-shell while being hauled out. Remove all damaged plywood in way of forward port side engine room and aft port side bunk room. Area to be remove extends down to chine and above rub-rail. Coordinate USCG inspection once damaged areas are removed to discuss repairs.
Action required: 705 - Other - as specified
Resolved 28 October 2024
Resolution: Damaged area was repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 August 2024
Resolved
Oil staining was observed in the bunk room bilge forward of engine room, indicating that the forward engine room bulkhead is not watertight. Make repairs to the bulkhead and prove water tight integrity.
Action required: 705 - Other - as specified
Resolved 7 November 2024
Resolution: The forward engine room bulkhead was sealed with epoxy and made water tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2024
Resolved
Renew both port and stbd rudder packing assemblies, both were found to wasted and pose a flooding risk.
Action required: 705 - Other - as specified
Resolved 18 November 2024
Resolution: New rudder packing assemblies were installed on both rudders.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 August 2024
Resolved
Make all sea valves available for inspection, remove all grates/strainers from hull to inspect hull condition.
Action required: 705 - Other - as specified
Resolved 18 November 2024
Resolution: Inspected 1 gate valve and 05 ball valves, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 August 2024
Resolved
Remove all zincs to inspect hull condition.
Action required: 705 - Other - as specified
Resolved 16 September 2024
Resolution: All zincs were removed and fiberglass was inspected, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 August 2024
Resolved
Remove all rotted plywood inside fore-peak compartment port side. Coordinate USCG inspection once damaged areas are removed to discuss repairs.
Action required: 705 - Other - as specified
Resolved 7 December 2024
Resolution: Satisfactory repairs were made to rotted plywood.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 15 August 2024
Resolved
Repair fore-peak ladder, the bottom rung was found to be broken.
Action required: 705 - Other - as specified
Resolved 16 September 2024
Resolution: Ladder was repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 15 August 2024
Resolved
Areas of rot were found outboard of the engine room stbd fuel tank. Remove and replace rotted timber at the deck clamp and section of marine plywood on the aft vertical support.
Action required: 705 - Other - as specified
Resolved 21 October 2024
Resolution: Rotted areas removed and new structure installed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 15 August 2024
Resolved
The collision bulkhead was found to be de-laminated from the bottom and side-shell plywood in the fore-peak with areas of rot also identified. Remove all fiberglass and epoxy where the collision bulkhead meets the bottom and side-shell plywood. Once complete, notify SSD for re-inspection.
Action required: 705 - Other - as specified
Resolved 7 November 2024
Resolution: Rotted areas removed and new plywood installed. Bulkhead was re-sealed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 August 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at
least once every two years. Vessel drydock expired on 31JUL24. Vessel is current on the "No Sail" list. Conducted required drydock as required by current regulation.
46 CFR 176.600
17 - Rectify deficiencies prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2024
Resolved 19 November 2024
Resolution: Vessel completed credit hull exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2024
No resolution recorded
Vessel installed a sewage tank in the forward berthing area without Coast Guard approval. The Coast Guard Marine Safety Center has determined that new incline stability calculations must be submitted for review. Submit incline stability calculations and sewage piping/venting plans to MSC for for review and approval. To be rectified by 02 October 2024, or this deficiency may be changed to "Action 17: Rectify prior to departure."
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2024 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 May 2024
Resolved
Vessel's fire detector in the engine room is not designed for use in a space with that high of an ambient temperature. Replace the engine room smoke detector with an appropriate model for the space and ensure compatibility with the other integrated smoke detectors. The new detector must meet UL 217. A satisfactory test of the new detector must be completed in the presence of a USCG marine inspector. To be rectified by 29 May 2024.
Cites: 46 CFR 181.405(c) & 46 CFR 181.450
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 30 May 2024
Resolution: New detector was installed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2024
Resolved
The port MDE fuel filter does not have a flame impingement bowl installed. Install a manufacturer approved flame impingement bowl under the port MDE fuel filter. To be rectified by 24 April 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2024
Resolved 15 May 2024
Resolution: A flame impingement bowl was installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 February 2024
Resolved
Vessel is passed due for its annual inspection. Complete satisfactory annual inspection with USCG marine inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2024
Resolution: Completed Annual Inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 February 2024
Resolved
Several of the vessel's life floats were not serviceable. Repair or replace the affected life floats. Total persons authorized to be carried by the vessel is reduced to 94 (89 of which may be passengers) until this deficiency is recitified.
Action required: 705 - Other - as specified
Resolved 28 June 2024
Resolution: Vessel did not correct deficiency, so COI was amended for lower total person count.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2024
Resolved
Vessel's galley range hood was heavily soiled with grease throughout the hood and associated vent. Clean out excess grease from range hood/vent to satisfaction of attending USCG marine inspector. To be rectified by 24 April 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2024
Resolved 15 May 2024
Resolution: Range hood was cleaned of grease.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 February 2024
Resolved
Vessel's overboard valve for its Type III Marine Sanitation Device (MSD) is not secured in a manner which prevents discharge of sewage. Secure the overboard valve for the MSD in one of the three approved ways described in 33 CFR 159.7(c). To be rectified by 24 April 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2024
Resolved 15 May 2024
Resolution: A chain was installed on the overboard valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 February 2024
Resolved
Vessel installed a sewage tank in the forward berthing area without Coast Guard approval. Submit plans for the sewage tank installation to the local Coast Guard inspections office for review/approval, and submit plans to the Coast Guard Marine Safety Center for stability review. To be rectified by 14 June 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 28 June 2024
Resolution: Received call from MSC that they had received the plans for review.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 July 2023
Resolved
As stated in letter dated September 14, 2023, vessel must comply with Fire Safety of Small Passenger Vessels Interim Final Rule requirements by the next scheduled dry dock or 01JAN2026, whichever comes first. Vessel does not meet requirements and is restricted from carrying overnight passengers in accommodation spaces.
National Defense Authorization Act for Fiscal Year 2024 (H.R. 2670), Section 3531(b)
Action required: 705 - Other - as specified
Resolved 13 February 2025
Resolution: COI is restricting vessel from operating as an IFR applicable vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2022
Resolved
STBD Rudder Post leak at packing unit during transit; approx 3-4 drop per second. Verify and adjust packing to minimize excessive leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 15 December 2022
Resolution: CORRECTED
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2022
Resolved
STBD side ground bonding strap broken at fastener connection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 15 December 2022
Resolution: CORRECTED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 November 2022
Resolved
Main fuel tank in engine room flex hose secondary clamp not properly secured. Repair / replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 15 December 2022
Resolution: CORRECTED
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2022
Resolved
Hot water heater space portside forward; two electrical panel enclosures not properly sealed and two two faste-
ners missing at front cover. Repair / replace.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 15 December 2022
Resolution: CORRECTED
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2022
Resolved
Firemain piping forward has leak and has a temporary soft patch installed. Provide repair proposal to [email withheld] for review and approval.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 16 December 2022
Resolution: CORRECTED
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 August 2022
Resolved
Clean-up and apply sealant around bait tank discharge lines on vessel transom
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 27 October 2022
Resolution: CG MI's witnesses sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 August 2022
Resolved
Replace deck frame IVO hatch in port fish hold
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 27 October 2022
Resolution: CG MI's witnesses sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 17 August 2022
Resolved
Sand down to good wood on the sheer clamp in the port engine space
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 27 October 2022
Resolution: CG MI's witnesses sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 17 August 2022
Resolved
Sand down to good wood on the chine block on the stbd side of engine space
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 27 October 2022
Resolution: CG MI's witnesses sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 August 2022
Resolved
Seal hole on bottom skin of vessel IVO of generator raw water intake. Right in front of shaft logs
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 27 October 2022
Resolution: CG MI's witnesses sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 August 2022
Resolved
Remove compromised plywood from deck beam and replace with good wood on Aft deck beams of forward compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 27 October 2022
Resolution: CG MI's witnesses sat repairs.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 August 2022
Resolved
Sand down to good wood on deck surrounding support beam in bunk house between bunks 15 and 16.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 27 October 2022
Resolution: CG MI's witnesses sat repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 August 2022
Resolved
Re attach double clamps to hose to the fuel tank on port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 27 October 2022
Resolution: CG MI's witnesses sat repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 August 2022
Resolved
On 03 AUGUST 2022, hull exam was conducted on vessel for required dry-dock and eight (08) work-list items were issued to receive credit. On 17 August 2022, it was discovered that the vessel left dry-dock, therefore all work-list items were converted to CG 835V with Code 16C and sent to operator via email.
On 20 October 2022, it was discovered by a USCG Marine Inspector that none of the dry-dock work-list items have been completed.
Vessel is not permitted to operate with passengers until all dry-dock items on CG 835V issued on 17 August 2022 have been rectified to the satisfaction of the USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2022
Resolution: CG MI's witnesses sat repairs.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 February 2022
Resolved
Every Vessel subject to Part 3 of title 3 of the communications act must have a detailed inspection of the radio installation by an FCC licensed technician once every five years. FCC safety radiotelephone certificate found to be expired. Provide valid certificate from FCC technician.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 29 April 2022
Resolution: POC Provided proof of safety certificate
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 February 2022
Resolved
DSC VHF radio found to have MMSI and GPS information not
installed. Program radio to provide MMSI and GPS
information.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 29 April 2022
Resolution: POC Programmed DSC radio with MMSI and GPS information
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 February 2022
Resolved
Installed life float missing floating waterlight. Vessel restricted to daytime operations until light is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2022
Resolved 15 March 2022
Resolution: Replaced water light.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 25 February 2022
Resolved
Life floats found to have vessel name illegible due to wear. Mark or paint vessel name in clearly legible letters on each life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 29 April 2022
Resolution: POC Labeled life floats with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2022
Resolved
Vessel found to have an insufficient number of adult life-jackets on board per issued COI. Vessel passenger count restricted to 116 until the appropriate number of lifejackets are proveded.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2022
Resolved 29 April 2022
Resolution: POC Provided adequate number of life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2022
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Chest freezer in galley found to be not securely mounted. Mount freezer to prevent movement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 27 April 2022
Resolution: POC securely mounted freezer to deck.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 February 2022
Resolved
Repair emergency light not working in aft accommodation space stbd side.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 29 April 2022
Resolution: POC showed working emergency lighting in accomodation space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2022
Resolved
Properly hard wire blower in E/R with marine grade cable. Provide repair proposal with blower load, cable AWG size and breaker size.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 29 April 2022
Resolution: O/O hard wired blower in E/R with marine grade cable. Verified by MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2022
Resolved
Replace outlet cover at fwd accommodation entrance and J-box cover in E/R by blower port side.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 15 March 2022
Resolution: POC provided proof of outlet cover.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 February 2022
Resolved
Replace missing fire extinguisher mount in E/R.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 27 April 2022
Resolution: POC Provided proof of mounted extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2022
Resolved
Have CO2 cylinders for fixed fire-fighting system hydrostatically tested by fire servicing agency.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 27 April 2022
Resolution: POC Provided proof of Fire system servicing.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 25 February 2022
Resolved
Seal deck above E/R.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 29 April 2022
Resolution: POC applied sealant to deck above engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 25 February 2022
Resolved
Repair leaking FW piping at the following locations: galley sink, port head sink and combined sink drain at centerline
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 29 April 2022
Resolution: POC Repaired leaking pipes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 March 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2021
Resolution: Repaired dampener, sea trials SAT.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 19 February 2021
Resolved
Modular smoke detector in galley did not operate. Battery replaced and tested on the spot.
Action required: 10 - Deficiency Rectified
Resolved 19 February 2021
Resolution: Battery replaced.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 August 2020
Resolved
VESSELS FCC RADIO STATION AUTHORIZATION HAS BEEN EXPIRED SINCE 30 MARCH 2020. VESSEL IS TO OPERATE NO MORE THAN 1,000 FEET FROM SHORE UNTIL VALID FCC DOCUMENT HAS BEEN VERIFIED BY A USCG MARINE INSPECTOR.
Action required: 705 - Other - as specified
Resolved 1 September 2020
Resolution: verified current
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 February 2020
Resolved
Mark all life floats with vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2020
Resolution: All floats marked.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 February 2020
Resolved
Remove zip ties from painter line for life floats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2020
Resolution: Zip ties removed from painter line.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 February 2020
Resolved
Replace cracked port bridge window.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2020
Resolved 17 August 2020
Resolution: replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 February 2020
Resolved
Make forepeak and bunkroom bilge alarms visually and audibly operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2020
Resolution: Bilge alarms operational.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 February 2020
Resolved
Make signs for 40 persons allowed on galley deck and 6 persons allowed in wheelhouse in accordance with stabilty letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2020
Resolution: Signage inplace
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 February 2020
Resolved
Provide valid radio station authorization license.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 September 2020
Resolution: verified current
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 10 February 2020
Resolved
Conduct and log monthly EPIRB test.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 February 2020
Resolution: EPIRB test conducted and log.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 10 February 2020
Resolved
Make Public Address system operational in accommodation area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 February 2020
Resolution: PA operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 February 2020
Resolved
Replace broken hydraulic gauge in laz.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2020
Resolution: Gauge replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 10 February 2020
Resolved
Mark top of emergency escape hatch. "Emergency Exit"
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2020
Resolution: Escape hatch marked
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 February 2020
Resolved
Mount generator cooling water strainer.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2020
Resolution: Cooling water strainer mounted
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 10 February 2020
Resolved
Repair leaking bathroom sink that is leaking into accommodation area below.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2020
Resolution: Bathroom sink repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 February 2020
Resolved
Properly mount fire main at starboard side fire station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2020
Resolution: Fire main mounted
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 February 2020
Resolved
Provide UL approved 50ft fire hose in place of current 100ft hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2020
Resolution: Fire hose was provided on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 February 2020
Resolved
Make approved repairs to life float that was not onboard vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2020
Resolution: Repairs made
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 February 2020
Resolved
Prove operational of bilge pumping arrangement for all spaces.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2020
Resolution: Bilge pump operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2020
Resolved
Provide valid alcohol strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 February 2020
Resolution: Alcohol stips provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2020
Resolved
Provide working lights for all lifejackets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: 70 life jacket lights provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 February 2020
Resolved
Replace forward worn lifering.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2020
Resolution: Lifering replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 February 2020
Resolved
Provide marking for all fuel shut off locations. Current lettering is not legible.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2020
Resolution: Fuel marking provided.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 February 2020
Resolved
Provide 30x30 flame screen for fuel vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2020
Resolution: Fuel vent was provided with flame screen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2020
Resolved
Provide proper fastner for port fuel stainer. Currently using a vice grip.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2020
Resolution: Fuel strainer attached with proper fastener.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2020
Resolved
Provide appropriate drug and alcohol documentation. Audit to be conducted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 March 2020
Resolution: Vessel rep provided all required DAPI documentation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps. Due 09Jan2020.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 January 2020
Resolved 1 September 2020
Resolution: received
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 9 October 2019
Resolved 9 October 2019
Resolution: Educated operator.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019
Resolved
Provide accommodation compartment with an additional emergency exit light at escape. Due 09Jan2020.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 January 2020
Resolved 14 October 2019
Resolution: additional lighting installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 October 2019
Resolved
Repair galley fire suppression vent blower shut-down and manual pull handle. Provide servicing report after repairs. NO USE OF GALLEY EQUIPMENT UNTIL CLEARED. Due 09Nov2019.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 14 October 2019
Resolution: Repaired.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018
Resolved
ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 September 2020
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 July 2018
Resolved
Provide repair proposal for holed stern port quarter. Make authorized repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2018
Resolved 3 August 2018
Resolution: Repairs completed.
Lifesaving › Lifefloat › Serviceable
Issued 21 November 2017
Resolved
Properly maintain starboard forward and portside forward top life float (Found 04) Restricted to 90 persons
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 29 June 2018
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 November 2017
Resolved
Replace all expired batteries in all floating waterlights.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 2 February 2018
Resolution: all batteries were replaced
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 November 2017
Resolved
Prove proper operation of forward bilge alarm (visual Indicator)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 2 February 2018
Resolution: Bilge alarm properly working.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 November 2017
Resolved
Replace all lines for life float waterlights.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 21 December 2017
Resolved 21 December 2017
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2017
Resolved
Replace portable battery charger conductor underneath pilothouse. (marine cable and properly installed permanent)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 21 December 2017
Resolved 21 December 2017
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2017
Resolved
Install covers for berthing light on port and starboard
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 21 December 2017
Resolved 21 December 2017
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 November 2017
Resolved
Replace pilothouse broken window.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 21 December 2017
Resolved 21 December 2017
Construction/Loadline › Hull › Side Shell
Issued 20 August 2017
Resolved
Submit repair proposal and make proper repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2017
Resolution: Repair plan submitted and repair completed.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 3 March 2016
Resolved
Properly label stowage of child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 18 March 2016
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 3 March 2016
Resolved
Renew gasket on forward deck hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 18 March 2016
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 3 March 2016
Resolved
Properly secure forward hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 18 March 2016
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 March 2016
Resolved
Properly label forward emergency escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 18 March 2016
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2016
Resolved
Make forward bunkroom bulkhead watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 25 July 2017
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 3 March 2016
Resolved
Lock closed sewage discharge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 18 March 2016
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 3 March 2016
Resolved
Renew smoke detector in forward bunk room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 18 March 2016
Engineering › Fuel Oil Service System › Tank
Issued 3 March 2016
Resolved
Properly label fuel fills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 18 March 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 March 2016
Resolved
Provide safety shields for fuel shut off valves located in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 18 March 2016
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 3 March 2016
Resolved
Reinforce forward bunk room deck inspection cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 25 July 2017
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 3 March 2016
Resolved
Provide ventilation closures for 02 additional engine room vents.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 18 March 2016
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 3 March 2016
Resolved
Ensure proper operation of all life jacket lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 4 March 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 March 2016
Resolved
Ensure proper operation of all life float and life ring water lights. (13). Correct prior to operating after sunset.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 4 March 2016