Records from 1996 to 2017. Most recent: inspection, 26 January 2017.
Inspection history · 23
26 January 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6071461
4 July 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5929229
29 June 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5923267
31 August 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4130977
28 August 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4129375
19 December 2009
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3648681
21 January 2007
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2859262
17 January 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2857650
11 October 2006
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2798186
4 October 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2793861
20 August 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2753552
9 May 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2638375
25 March 2006
Deficiency Check
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 2609489
11 July 2005
NPV Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2422470
1 July 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2117983
21 April 2004
Passenger/Freight Vessel Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2049251
20 December 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1967699
20 December 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1968730
23 April 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1608787
6 April 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 288717
3 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434394
17 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413910
4 January 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 386138
Fire Fighting › Nozzles
Issued 21 April 2004
Resolved
Replace fire hoze nozzle between #2 and #3 cargo holds on deck with solas approved vari-nozzle. LEGACY COMPONENT DESC: Type
Due 28 April 2004
Resolved 21 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 21 April 2004
Resolved
Intall light globe and guard at light above stbd side engine. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Placed in Improper Service
Due 28 April 2004
Resolved 22 April 2004
Resolution: Removed light fixture entirely.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 21 April 2004
Resolved
Sprinkler head covered with paint.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2004
Resolution: Cleaned and removed paint from sprinkler head.
Fire Fighting › Combustible Materials
Issued 21 April 2004
Resolved
Remove paints from stbd side store room. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Condition: Improper/Lack of Maintenance
Due 28 April 2004
Resolved 21 April 2004
Lifesaving › Launching Appliances
Issued 21 April 2004
Resolved
Lifeboat gripes w/ hook on stbd and port lifeboats must be repaired/modified to ensure safe operation upon release. During lifeboat lowering, hook on poprt lifeboat became tangled with lifeboat and presented safety hazard. Notify class of event and actions taken to prevent re-occurrence. LEGACY COMPONENT DESC: Lines
Due 28 April 2004
Resolved 22 April 2004
Resolution: Received class report of approved configuration. Vessel will replace "bulldog" gripe w/ swaged type sling fitting and install new wire to ensure proper operation of the gripes.
Deck/Cargo › Ballast
Issued 20 December 2003
Resolved
Provide class report as to damaged side shell area IWO 1S ballast tank. Fax report to USCG as stated. LEGACY COMPONENT DESC: Tank
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 31 December 2003
Resolution: Received Lloyd''s Register Class report #MMI340229 dated 31DEC03 showing that class was onboard and has issued a condition to be corrected by November 2004 for the damaged area in way of #1 starboard top side wing ballast tank
Construction/Loadline › Structures
Issued 20 December 2003
Resolved
Provide class report as to damaged stbd bulwark, (i.e.repair status) . Fax report to USCG.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2003
Resolution: Received Lloyd''s Register Class report #MMI340229 dated 31DEC03 showing that bulwark has been repaired.