MAURY USCG vessel records
← All vessels

PENN NO. 90

PENN NO. 90 is a 2002 tank barge. The Coast Guard has recorded 56 inspections since 2002, most recently in January 2024, along with 29 deficiencies — 4 with no resolution recorded —, 1 operational control and 9 casualty investigations between 2003 and 2018.

Records from 2002 to 2024. Most recent: inspection, 24 January 2024.

Built
2002
Last inspected
24 January 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 24 January 2024
…with no type recorded14
Operational controls None recorded without a removal date
Years with a record 22 calendar years (2002–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1518339
WDA9795
585669
Flag
UNITED STATES
Maury page id
psix-585669

Documentation record

Registered dimensions (L × B × D)395.4 ft × 76.3 ft × 31.2 ft
Registered tonnagegross 7,592 / net 4,311
ITC dimensions (L × B × D)395.4 ft × 76.3 ft × 31.2 ft
ITC tonnagegross 7,592 / net 4,311
BuilderALABAMA SHIPYARD · MOBILE, AL, UNITED STATES · built 2002
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7592 - Convention (Subpart B), Gross Ton
4311 - Convention (Subpart B), Net Ton
16162 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 56

24 January 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7853729
23 January 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7854090
22 September 2022 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7562989
22 November 2021 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7349784
8 November 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7347626
10 February 2021 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7139346
15 December 2020 Periodic Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7112374
22 October 2020 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7082130
27 May 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6961647
26 August 2019 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6794742
19 August 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6791425
26 November 2018 MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6586855
5 June 2018 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6612295
14 August 2017 COI Inspection · MARPOL Annex I Examination · Drydock Exam · Internal Structural Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6240066
1 December 2016 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6050499
30 August 2016 Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5987153
8 February 2016 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5813879
17 November 2015 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5763251
29 September 2015 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5733362
30 October 2014 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5013047
6 November 2013 MTSA Verification · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4748376
29 October 2013 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4743504
25 October 2012 Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4472653
10 September 2012 MTSA Verification · COI Inspection · Drydock Exam · Internal Structural Exam · Cargo Tank Internal · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4437456
24 May 2012 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4321909
22 May 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4321338
10 November 2011 Annual Inspection · MARPOL Annex IV Survey · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4186110
12 August 2010 Periodic Inspection · MTSA Verification · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3822017
19 May 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3742231
12 March 2010 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3694501
17 September 2009 Annual Inspection · MTSA/ISPS Verification · MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3599860
1 September 2009 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3582499
9 September 2008 MARPOL Annex V Examination · MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3320819
18 November 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3100510
17 November 2007 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3100789
6 September 2007 MARPOL Annex V Examination · COI Inspection · Hull Examination · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3049979
19 June 2007 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2967864
13 June 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2968210
14 December 2006 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2840300
6 October 2006 MARPOL Annex V Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2795130
23 August 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2758097
29 August 2005 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2478220
24 August 2005 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2478215
23 July 2005 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2436780
23 May 2005 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2365880
16 December 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2261226
25 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2228141
14 October 2004 MTSA Verification · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2220968
17 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2016338
20 December 2003 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1967557
20 December 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1968730
12 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980786
5 September 2003 Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1897431
3 December 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1715222
20 October 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1695324
1 April 2002 Cargo Tank Internal · Initial Certification · Initial Construction-Excluding Oversight · MARPOL Annex I Examination · Hull Examination · Construction Oversight · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1661540

Deficiency record · 29

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 September 2022 No resolution recorded
Vessels that operate in salt water must be inspected in accordance with the intervals set forth in table 31.10-21(a). Where table 31.10-21(a) indicates a 2.5 year examination interval, it means a vessel must undergo two examinations within any five year period. Vessel must undergo a dry dock, internal structural exam, and cargo tank internal exam prior to operation. 46 CFR 31.10-21(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 22 September 2022 No resolution recorded
Each load line certificate is issued for the following length of time: (1) An international and coast-wise certificate is issued for 5 years. Vessel must have a valid "manned" load line certificate onboard prior to operation. 46 CFR 42.07-45(d)(1)
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 22 September 2022 No resolution recorded
Each cargo vessel on which the horizontal distance from the extreme end of the stem or stern of the vessel to the nearest end of the closest survival craft is more than 100 meters (328 feet) must carry, in addition to the liferafts required by paragraphs (b)(2) and (c)(2) of this section, a liferaft stowed as far forward or aft, or one as far forward and another as far aft, as is reasonable and practicable. The requirement for the liferaft to float free under 199.130(c)(7) does not apply to a liferaft under this paragraph, provided it is arranged for quick manual release. Vessel did not have a forward liferaft. Prior to issuance of COI. 46 CFR 199.261 (e)
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 September 2022 No resolution recorded
Each inflatable lifesaving appliance must be serviced - Within 12 months of each subsequent servicing. Liferaft is past due on the servicing. Prior to issuance of COI. 46 CFR 199.190 (g)(i)(2)
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 December 2020 Resolved
Vessel did not have required 10 ring buoys as per 46CFR199.271. With the addition of ring buoys the vessel is required 5 lighted buoys IAW 46CFR199.70(a)(3)(ii)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2020
Resolved 1 February 2021
Resolution: Def cleared: All required life rings have been purchased and installed.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 15 December 2020 Resolved
The bunker delivery note shall be accompanied by a representative sample of fuel oil delivered taking into account guidelines developed by the Organization. Signed by supplier and vessel master samples kept on-board for a period of no less than 12months from delivery. Barge did not have samples on-board or means for continuous drip sampling. MARPOL VI/18.8.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2020
Resolved 18 December 2020
Resolution: Verified sample stowage and ordered continuous drip replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 December 2020 Resolved
At each periodic inspection the marine inspector shall conduct test of machinery to check safe operation. At the time of inspection the operator was unable to conduct low lube oil test on generators. 46CFR32.35-1 46CFR61.20-3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2020
Resolved 18 December 2020
Resolution: Provided Tech report for low lube oil pressure shutdown on generators.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 December 2020 Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers. Missing fan belt covers on both Cargo pump engines. 46CFR32.02-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2020
Resolved 18 December 2020
Resolution: Fabricated fan belt guards to be placed in service.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 December 2020 Resolved
The high-level alarm and tank overfill alarm must activate an alarm during the failure of electrical circuitry to the tank level sensor. Barge was unable to produce Cargo Alarm panel loss of power alarm at the time of inspection. 46CFR39.2007(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2020
Resolved 18 December 2020
Resolution: Serviced Alarm panel, tech verified functioning properly.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 26 November 2018 Resolved
Each shipboard marine cable must meet all the requirements for construction and identification of standards listed in 46 CFR 111.60-1. In way of chafing protection, the mooring winch motor cable jacket is visibly worn to conductor insulation. Inspect remaining winch cable for wear and submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2018
Resolved 12 December 2018
Resolution: Repairs made to satisfaction of MI, per accepted repair proposal and service reports.
Engineering › Pressure Vessel › Marking and Stamping
Issued 17 November 2015 Resolved
The air receiver in the generator house has its data plate covered. Provide clear visibility and idenfication of the date plate.
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 18 November 2015
Resolution: Vessel rep provided pictures of legible data plate.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 November 2015 Resolved
The navigation light screens do not have matted black screen. Install matted black screen on all navigation light screens.
Action required: 705 - Other - as specified
Due 17 November 2015
Resolved 8 February 2016
Resolution: Nav Screens painted matt black.
Electrical › Electric Supply System (service) › Cable
Issued 17 November 2015 Resolved
The cables entering the fan in the genrator room must be secured and closed. Secure the cable and close the oepning which the conductors enter.
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 8 February 2016
Resolution: Electrical cables satisfactorily secured.
Engineering › Fuel Oil Service System › Filter
Issued 17 November 2015 Resolved
The fuel filters on the prime movers in the generator house must remove drain cocks and install drain plugs.
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 8 February 2016
Resolution: Fuel filter drain plugs installed on all equipment.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 17 November 2015 Resolved
02 B-V Semi Portable fire fighting extinguishers must be served annually. Provide inspection record for the required servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2015
Resolution: Provided proper servicing certificates.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 17 November 2015 Resolved
Overfill and high level alarms are not labeled. The alarms must be identified with the legend "High level alarm" and "TANK OVERFILL ALARM" in black letters on a white background.
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 8 February 2016
Resolution: Tank overfill and high level alarms properly labled.
Deck/Cargo › Cargo Stowage › General
Issued 17 November 2015 Resolved
Flmmable products are inappropriately stowed in the non flammable locker in the aft portion of the vessel. Provide fixed fire fighting system to the locker or remove flammable products from the locker.
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 8 February 2016
Resolution: Flammable material removed from deck locker.
Construction/Loadline › Hull › Side Shell
Issued 24 May 2012 Resolved
Barge is authorized one time transit to conduct repairs in Sector New York's zone. Barge is not to conduct cargo operations until cleared by [name withheld].
Action required: 705 - Other - as specified
Resolved 24 May 2012
Resolution: #3s void was gas freed and open for inspection by marine inspector.
Construction/Loadline › Hull › Transverse Frame
Issued 24 May 2012 Resolved
Not to conduct cargo operations till #3S cargo tank be gas freed and available for inspection by attending coast guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2012
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 19 May 2010 Resolved
Barge Penn 90 lost anchor while preparing to depart the Bayridge Anchorage on April 10, 2010. Anchor shaft was found to be intact, the flukes were found broken.
Due 19 May 2010
Resolved 19 May 2010
Resolution: Received class (ABS) report attesting to satisfactory repair and operational test of anchoring system.see attached documents. Deficiency cleared.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 November 2007 Resolved
Replace damaged deck railing at next drydock or next time vessel is gas freed to the satisfaction of CG marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 December 2007
Resolution: Permanent repairs made to railing.
Construction/Loadline › Hull › Hull Plating
Issued 23 July 2005 Resolved
C/R minimum 18" x 30" sideshell, portside IWO frames 7 & 8 in forepeak to CG or ABS satisfaction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2005
Resolved 26 July 2005
Resolution: Received satisfactory class report attesting to proper repairs and testing of plate insert.
Construction/Loadline › Structures › Superstructure
Issued 2 October 2004 Resolved
Superstructure on port side forward where welded to the deck exhibits repeated minor fracturing in the weld (4"-6" fracture). Vessel PIC indicated fracture had been repaired several times but reappears as a result of cargo loading and discharge. Vessel to make permanent repairs and reinforce at next drydock or at next gas freeing of cargo tank which ever comes first.
Condition: Unknown
Due 4 August 2007
Resolved 14 September 2005
Resolution: Area welded and reinforced with multiple welding passes.
Construction/Loadline › Hull
Issued 20 December 2003 Resolved
DAM01: Clean and gas free DB/DS 4S as per marine chemist. Make ready for inspection, prior to departing port. LEGACY COMPONENT DESC: Double Hull
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 January 2004
Resolution: Tanks entered by ABS. Survey submitted and approved, vsl allowed to sail.
Engineering › Fuel Oil Storage/Transfer System
Issued 20 December 2003 Resolved
Clean and gas free fuel storage tank as per marine chemist and effect repairs to the same (ie holed, inset fwd stbd upper corner) Prior to departing port. LEGACY COMPONENT DESC: Tank
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2003
Resolution: Temp repairs effected and witnessed by ABS. Cleared via fax.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 December 2003 Resolved
Repair damage rails/stanchions top of machinery house. LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Bolts
Issued 20 December 2003 Resolved
Repair cut flood light (stbd) wires prior to any night transfer operations to satisfaction of USCG Marine Inspector. LEGACY COMPONENT DESC: Lighting
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2005
Deck/Cargo › Cargo Heating › General
Issued 20 December 2003 Resolved
Repair cut TFH alarm wires, prior to use.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 20 December 2003 Resolved
Secure all electricity to wires that have been cut on top of machinery house. LEGACY COMPONENT DESC: Wiring
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2005

Casualty record · 9

20 December 2003Significant Marine Casualty · role: Involved in a Marine Casualty · activity 1968730
23 August 2006Routine · role: Acknowledged Pollution Source · activity 2758097
13 June 2007Routine · role: Involved in a Marine Casualty · activity 2968210
18 November 2007Routine · role: Involved in a Marine Casualty · activity 3100510
8 November 2009Routine · role: Involved in a Marine Casualty · activity 3630150
12 March 2010Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3694501
22 May 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4321338
1 December 2016Routine · role: Involved in a Marine Casualty · activity 6050499
5 June 2018Routine · role: Involved in a Marine Casualty · activity 6612295
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.