Records from 1996 to 2025. Most recent: inspection, 19 September 2025.
Inspection history · 118
19 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8237528
7 August 2025
Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8202005
23 January 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8069062
4 September 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7995975
23 April 2024
In-Service Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7899893
11 April 2024
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893382
5 October 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7803816
7 June 2023
Annual Inspection · ACP COI Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704680
15 February 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7637553
16 February 2022
ACP COI Oversight · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7397471
12 February 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7395313
8 July 2021
Annual Inspection · Administrative Inspection · Drydock Exam · ACP Annual Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7384519
18 June 2021
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7231423
13 October 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7079623
1 October 2020
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7069724
22 June 2020
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6983396
18 December 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6875850
19 October 2019
Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6839274
30 September 2019
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6827883
1 July 2019
ACP Periodic Oversight · Administrative Inspection · ACP Additional Oversight – Risk Assessment · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6731601
7 June 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6706463
19 October 2018
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6564570
11 September 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6543493
29 August 2018
ISM SMC Audit · Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6526399
9 August 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6506211
7 August 2018
ISM Oversight
Administrative · Commandant (CG-5P-TI) · Activity 6503410
21 February 2018
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6371634
10 February 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6369153
8 February 2018
ACP Additional Oversight – Risk Assessment
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6351712
31 January 2018
ISM SMC Audit · Re-Inspection · Deficiency Check · ACP COI Oversight · Spot Check · Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6378700
27 November 2017
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6313018
24 October 2017
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6293772
6 July 2017
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6200475
6 July 2017
Annual Inspection · ACP Annual Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6208501
9 December 2016
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6057172
28 November 2016
ACP Annual Oversight · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6048715
25 November 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6048716
18 July 2016
Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5963192
5 October 2015
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5735412
8 May 2014
COI Inspection · ACP COI Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4853042
11 June 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4340631
19 January 2012
ACP Periodic Oversight
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4227638
10 January 2012
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4239724
9 January 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4221563
30 December 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4215969
21 September 2010
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3853939
24 July 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3544511
1 July 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3520236
1 July 2009
In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3527252
27 March 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3441158
20 March 2009
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3438548
9 March 2009
Hull Examination · ACP Annual Oversight · Examination of Repairs · ACP COI Oversight · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3430171
19 February 2009
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3420720
20 January 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3420661
14 October 2008
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3344065
4 September 2008
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3318054
1 September 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3315202
4 August 2008
Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3336989
9 March 2008
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 3191765
18 January 2008
Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 3132503
20 September 2007
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3064464
14 July 2007
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 3014974
17 October 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2802100
29 September 2006
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2792305
28 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2762132
28 July 2006
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2731824
29 June 2006
In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2695324
27 February 2006
ACP COI Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2592596
2 October 2005
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2506080
21 April 2005
ACP Annual Oversight
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2341896
1 October 2004
In-Service Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2210493
11 August 2004
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 2162934
22 July 2004
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2141489
28 June 2004
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2113521
20 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104599
29 May 2004
MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2085042
9 March 2004
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2021468
5 January 2004
In-Service Inspection · Administrative Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1974949
23 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976295
25 November 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1954330
10 April 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1777753
19 February 2003
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1742970
3 August 2002
In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1663697
16 February 2002
Deficiency Check · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1494610
5 December 2001
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 772366
1 October 2001
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1073815
30 September 2001
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1376792
19 July 2001
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1393742
21 June 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1067330
4 June 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1070011
28 March 2001
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1397703
19 March 2001
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1373420
8 March 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 815432
1 March 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 814129
8 December 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 812722
3 December 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 100609
1 November 1999
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1468540
15 October 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 789290
29 September 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1045345
3 August 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 109717
15 March 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 809076
1 March 1999
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 797779
5 February 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1127323
1 February 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1125575
7 January 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 809646
3 December 1998
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1406401
22 September 1998
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 799005
27 July 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 536180
11 June 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1129013
2 January 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 783658
11 November 1997
Hull Examination · Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1111580
30 June 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 778140
31 March 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1105717
31 December 1996
Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1102304
30 September 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1142639
30 June 1996
Construction Oversight · Reflagging & Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1093042
31 March 1996
Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1079562
12 March 1996
Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1447548
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 23 April 2024
Resolved
Whenever a vessel is deprived of the service of a member of its complement, and the master or person in charge is unable to find appropriate credentialed personnel to man the vessel […] a report of sailing short must be filed with the OCMI having cognizance for inspection in the area in which the vessel is operating, or the OCMI within whose jurisdiction the voyage is completed. Vessel master/rep made sailing short notification for the position of AB from Sector New York to Sector Jacksonville. Notify local OCMI once position has been filled.
Condition: Invalid
Action required: 702 - Prior to embarking on international voyage
Resolved 25 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 April 2024
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel made alterations to fuel transferring system by removing hydraulic actuated valve and causing personnel to enter confined space for every transfer operations also creating a down-flooding point. Vessel is to provide an alternate mean of operation not involving personnel entering the confined space to transfer fuel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2019
Resolved
SOLAS 74 (2004) I/11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present condition to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The port side anchor chain wash remote valve was found broken and inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 9 July 2019
Resolved
SOLAS 74 (2004) 11-2/13.1: The purpose of this regulation is to provide means of escape to that persons on board can safely and swiftly escape to the lifeboat and life raft embarkation deck. The port and starboard helicopter hangar doors were seized closed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 July 2019
Resolved
SOLAS 74 (1997) II-2/2.1: The purpose of this chapter is to require the fullest practicable degree of fire protection, fire detection and fire extinction in ships. Found multiple through deck penetrations previously used for cable runs in cargo room 1D converted to a gymnasium, not properly sealed to prevent the spreading of smoke and fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 9 July 2019
Resolved
MARPOL I/7.1: The Government of a Party to the present Convention may, at the request of the Administration, cause a ship to be surveyed and, if satisfied that the provisions of this Annex are complied with, shall issue or authorize the issue of an International Oil Pollution Prevention Certificate to the ship and, where appropriate, endorse or authorize the endorsement of that certificate on the ship in accordance with this Annex. Update IOPP Form A to reflect correct OWS installed, OWS throughput and account for correct tanks being sounded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2019
Resolved
SOLAS 74 (1997) II-2/6.1: All fire extinguishers shall be of approved types and design. Found numerous portable fire extinguishers throughout the ship with missing nozzle clips for proper storage on extinguisher bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/32.2: Each oil-fired boiler which is intended to operate without manual supervision shall have safety arrangements which shut off the fuel supply and give an alarm in the case of low water level, air supply failure or flame failure. Prove operation of the # 2 auxiliary boiler loss of combustion air alarm and shutdown, safety arrangement is currently not functional.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/26.1: The machinery, boilers, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Repair or replace the raw water leak on the inboard flange at the deck plating for the #3 auxiliary ship generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/26.1: The machinery, boilers, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any persons on board. Make repairs to the jacket water leaks at the # 6 cylinder for the # 1 main ship service generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/26.1: The machinery, boilers, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Make repairs to the misaligned rubber couplings on the # 1 and # 2 main ship service generators to alleviate the current strain on the installed couplings.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/26.1: The machinery, boilers, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Make repairs to the excessive leak on the emergency diesel generators jacket water heaters circulation pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/45.1.3: All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched. Secure dead ended wires associated with the #1 hot water recirculation pump located in the engine room pump located in the engine room boiler space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/25-9.1: The number of openings in watertight subdivisions is to be kept to a minimum compatible with the design and proper working of the ship. Where penetrations of watertight bulkheads and internal decks are necessary for access, piping, ventilation, electrical cables, etc., arrangements are to be made to maintain the watertight integrity. Make adjustments to the sliding watertight door leading into propulsion shaft alley to ensure full closure as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/25-9.1: The number of openings in watertight subdivisions is to be kept to a minimum compatible with the design and proper working of the ship. Where penetrations of watertight bulkheads and internal decks are necessary for access, piping, ventilation, electrical cables, etc., arrangements are to be maintain the watertight integrity. Conduct preventive maintenance to draft reading tube in shaft alley to prevent potential ingress of water.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
08 - Alarms › N/A - No Subsystem › General alarm
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) III/6.4.2: A general emergency alarm system complying with the requirements of regulation 50 shall be provided and shall be used for summoning passengers and crew to muster stations and to initiate the actions included in the muster list. The system shall be supplemented by either a public address system or other suitable means of communication. Repair general alarm light in the shaft alley to also rotate when illuminated.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/45.1.3: All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Hold #4 panel, EP5A, Emergency lighting panel, EL 115, FDR EL100-11 and Engine room seawater panel, EP-12B need covers installed where breakers are missing to prevent electrical injury.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 9 July 2019
Resolved
46 CFR 61.40-10: Vessel's Periodic Testing of Vital System Automation is lacking the procedures to adequately perform the Periodic Safety Tests Procedures (PSTP) required by 46 CFR 61.40-6 and 46 CFR 61.40-10. The current version of the vessel’s PSTP’s fail to address several of the systems required by the regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 9 July 2019
Resolved
SOLAS 74 (2014 Amend.) V/19.2.5.2: All ships of 500 gross tonnage and upwards shall, in addition to meeting the requirements of paragraph 2.3 with the exception of paragraphs 2.3.3 and 2.3.5, and the requirements of paragraph 2.4, have: a gyro compass heading repeater, or other means, to supply heading information visually at the emergency steering position if provided. Steering gear local gyro compass repeater is not visible from the local starboard steering pump control station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/26.1: The machinery, boilers, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Repair sounding tubes throughout the engine room to auto close as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 July 2019
Resolved
SOLAS 74(1997) III/19.2: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Lifeboats no. 1, 2, 3, and 4 were found with excessive oil and fuel in the engine compartment bilge.
Action required: 10 - Deficiency Rectified
Resolved 10 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 9 July 2019
Resolved
SOLAS 74 (2004)II-I/20-4.1: All transverse or longitudinal blkhds which are taken into account as effective to confine the seawater accumulated on the ro-ro deck shall be in place and secured before the ship leaves the berth and remain in place and secured until the ship leaves the berth and remain in place and secured until the ship is at its next berth. The stbd side ventilation's access covers in cargo hold 1A were not secured and missing fasteners.
Action required: 10 - Deficiency Rectified
Resolved 10 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 July 2019
Resolved
SOLAS 74(1997)III/19.2: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Found four personal flotation devices with expired lfie jacket lights.
Action required: 10 - Deficiency Rectified
Resolved 10 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 July 2019
Resolved
SOLAS 74(2004)II-I/45.1.3: All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Found dead end wires in overhead in passage way by the crew laundry room.
Action required: 10 - Deficiency Rectified
Resolved 10 July 2019
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 July 2019
Resolved
SOLAS 74(1997)II-2/12.3: Sprinklers shall be placed in an overhead position and spaced in a suitable pattern to maintain an average application rate of not less than 5L/m2/min over the nominal area covered by the sprinklers. Found damaged and missing sprinkler heads stbd side 02 deck, in way of JP-5 equipment room, and in way of free fall lifeboat.
Action required: 10 - Deficiency Rectified
Resolved 10 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.)II-2/7.1.1: The purpose of this regulation is to detect a fire in the space of origin and to provide for alarm for safe escape and fire-fighting activity. For this purpose, the following functional requirements shall be met: fixed fire detection and fire alarm system installations shall be suitable for the nature of teh space, fire growth potential and potential generation of smoke and gases. Secure overhead smoke detector in the cargo hold just outside of the steering gear compartment.
Action required: 10 - Deficiency Rectified
Resolved 10 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 July 2019
Resolved
SOLAS 74 (2004 Amend.) II-1/26.1: The machinery, boilers, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Remove hydraulic oil accumulation on steering gear flat and secure leaks.
Action required: 10 - Deficiency Rectified
Resolved 10 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2018
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ships shall be provided wiht an effective means for its operation and control. The main diesel engine will not answer dead slow commands, nor will it operate beyond 69RPM.
74 SOLAS (04) II-1/31.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2018
Resolved 15 October 2018
Resolution: Conducted sea trial, tested modes of prpulsion control, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2018
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in 74SOLAS(04)II-1/40.1.1 shall be provided. Main diesel generators #1 and #3 can not maintain lube oil temperature due to faulty lube oil coolers.
74SOLAS(04)II-1/41 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2018
Resolution: Lube oil cooler repairs were made, gens tested, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2018
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in 74SOLAS(04)II-1/40.1.1 shall be provided. Main diesel generator #2 failed due to a faulty voltage regulator.
74SOLAS(04) II-1/41 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2018
Resolution: Generator repaired and tested, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2018
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in 74SOLAS(04)II-1/40.1.1 shall be provided. Main diesel generators #4 and #2 have the wrong intake and exhaust valves installed per the manufacturer.
74SOLAS(04) II-1/41 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2018
Resolution: Generators repaired and tested, sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 August 2018
Resolved
Fixed fire detection and fire alarm system installations shall be suitable for the nature of the space, fire growth potential and potential generation of smoke and gases. Fire alarm panels show faults and alarms in various spaces (B deck drive through, C deck engineers, C deck cargo hold, and MPU fault detected).
74SOLAS(04) II-2/7.1.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2018
Resolution: Fire detection panel showed no faults.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 29 August 2018
Resolved
The company should establish procedures to ensure that thw ship is maintained in comformity with the provisions of the relevant rules and regulations and withany additional requirements whichmay be established by the company.
Action required: 60 - Rectify deficiencies prior to movement
Due 3 October 2018
Resolved 15 October 2018
Resolution: Corrected.
Lifesaving › Lifeboat › Safety Belt
Issued 15 February 2018
Resolved
01 seatbelt in totally enclosed lifeboat #2 found removed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 7 June 2018
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 15 February 2018
Resolved
Conduct ISM-SMC Intermediate Verification in the presence of USCG Marine Inspectors. The following ISM observations were identified during the inspection- A) M/E exhaust leakage was identified during OCI (MSC) inspection in November 2017. Crew began wearing dust masks & CO alarming meters. SAMMs VRR showed request for required meter shore-side calibration open 04FEB2016, calibration not completed. SMS also requires notification of hazardous conditions to be submitted to company. No notification submitted. B) All BW valves converted in 2016 during previous dry-dock. Numerous valves installed incorrectly or malfunctioning since install. No VRR submitted for correction until 2018. C) WTD 3rd party report from Apr 2017 indicated numerous failures of WTDs. 09 months have elapsed since initial report. D) Vessel crew is hindered by inabilities to access system for SMS repair work (SWFL/SAMM). Minimal crew have access, which increases time for others to input repair items. Possible STCW work/rest conflicts may occur without additional crew w/access to SMS repair system. ISM Code Part A Regs 10.2 & 6.2.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 10 December 2018
Resolution: CVC-4 along with local OCMI Marine Inspector conducted an ISM Audit.
Deck/Cargo › Ballast › Valves
Issued 14 February 2018
Resolved
Ballast tank levels in Deep 7-160-2, DB 8- 227(19) and BW-1B16 (converted gray water) can not be maintained. Possible ballast valve leak by occuring. Identify failures and repair.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 25 August 2018
Construction/Loadline › Structures › Door
Issued 14 February 2018
Resolved
Controls for WTD's throughout vessel have been identified with PLC failures. Indicator panel on bridge fails to indicate proper open/closed status. WTD to shaft tunnel is missing manual pump handle. WTD D-227(55) alarm does not work. 74 SOLAS (UnAmend) II-1/13(i)(i)
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 25 August 2018
Lifesaving › Rescue Boat › Weathertight Stowage
Issued 14 February 2018
Resolved
Rescue boat found lashed down improperly and not ready for immediate use.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 15 February 2018
Resolution: MI verified rescue boat properly lashed and ready for immediate use.
Lifesaving › Rocket Parachute Flares › General
Issued 14 February 2018
Resolved
62 flares for bridge and lifeboats found expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 15 February 2018
Resolution: MI verified proper lifeboat and bridge flares on board and in place.
Lifesaving › Lifebuoys › Serviceable
Issued 14 February 2018
Resolved
02 liferings on stbd side under lifeboats found with grablines excessively worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 15 February 2018
Resolution: MI verified new grablines installed around both life buoys.
Lifesaving › Lifeboat › Windows/Translucent Panels
Issued 14 February 2018
Resolved
Lifeboats #1 found with water ingress from port and top window. #3 found with water from aft door/hook penetration. Door gasket also broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 25 August 2018
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 14 February 2018
Resolved
Sprinkler heads at Fr150 in B5 cargo space and aft/port end of helicopter space missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 7 June 2018
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 14 February 2018
Resolved
Temp repairs (x3) found on sewage & head drains piping @ stbd WTD Fr 188.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 7 June 2018
Construction/Loadline › Structures › Door
Issued 14 February 2018
Resolved
Port & stbd hinged WTD's on A deck missing dogs. SOLAS 74 UnAm II-1/13(g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 7 June 2018
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Piping
Issued 14 February 2018
Resolved
Foam deck flooding pipe found damaged on 01 deck stbd side Fr298. Aerator to foam pipe under helicopter pad stbd side interior found covered with duct tape.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 7 June 2018
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 February 2018
Resolved
M/E exhaust leaking CO into engine room. Crew wearing uncalibrated CO meters for safety
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 25 August 2018
Resolution: Witnessed by class surveyor during departure from Charleston and sea trials and relayed to CG.
Personnel › Certificates/Documents/Licenses › MMD, Able Seaman
Issued 14 February 2018
Resolved
Identified crew member in AB postion with medical certificate stating "not valid for service as deck officer/rating." Member switched to OS position.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 14 February 2018
Resolution: Corrected on the spot. Additional GVU on board holding STCW AB endorsement. AB in def chose to sign off vessel. Vessel is properly manned as per COI.
Fire Fighting › Fixed Gas Fire Extinguishing System › Nozzle
Issued 14 February 2018
Resolved
A CO2 nozzle is missing from the high- pressure CO2 line in purifier room overhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 7 June 2018
Resolution: Approved plan/drawing indicates plug not nozzle in this line.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 February 2018
Resolved
The 12" salt water cooling line located on the STBD side,lower level of the Engine Room has multiple leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 7 June 2018
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 14 February 2018
Resolved
Oil is leaking from the overhead onto the generator side of the #3 MDG, presenting a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 25 August 2018
Resolution: Witnessed by ABS surveyor during underway departure from Charleston/sea trials and relayed sat to CG.
Engineering › Diesel Engine (auxiliary) › Cylinder
Issued 14 February 2018
Resolved
There is excessive oil leaking from the explosion cover for the #6 cylinder on #1 MDG.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 25 August 2018
Resolution: Witnessed by ABS surveyor during underway departure from Charleston/sea trials and relayed sat to CG.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 14 February 2018
Resolved
Jacket water was leaking from the inboard side of the #6 cylinder on the #1 MDG.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 25 August 2018
Resolution: Witnessed by ABS surveyor during underway departure from Charleston/sea trials and relayed sat to CG.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 24 October 2017
Resolved
OWS appears to be a mechanical issue and believe the issue is regarding the bearing. ABS has issued a OSR to be rectified 21NOV17. Meantime, vessel has sludge retention via holding tank. When surveyor attends he will ensure record book is update and discharge valve is locked to prevent inadvertent discharge to sea.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2018
Resolved 16 October 2018
Resolution: Rcvd copy of Class Survey Report via email from Class on 02OCT2019; OWS repaired with OEM parts and function test completed satisfactory. Class Survey Report No. JS3548396.
Navigation › Piloting/Steering › Marine Charts
Issued 24 October 2017
Resolved
ECDIS Failure due to electronic malfunction on the main and secondary display. Functionality remains due to back up arrangements and paper charts. ECDIS failure will be rectified through a technician prior to 21NOV17 date. ABS surveyor will review tech report and ensure satisfactory update of ECDIS prior to departure.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 November 2017
Resolved 14 February 2018
Resolution: Contacted ABS via phone. Confirmed ABS cleared item on 16NOV2017 after tech repaired ECDIS.
Lifesaving › Lifeboat › Hull
Issued 18 August 2017
Resolved
Lifeboats #1 & #2, water ingress of deck/seat foam core. Delamination of exterior shell of #2. Crack & delamination of #1 on port quarter. Repair lifeboats in accordance with Lifeboat Mfg. specs iaw 46 CFR 160.135-7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 25 August 2018
Resolution: Received email from vessel management stating that repair will be completed no later than 31Mar18. Updated CG-835 to reflect current status.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 28 November 2016
Resolved
Vessel currently undering going automation upgrades on vital valves to engineering plant. The overhaul requires full manning. Vessel is not approved for Periodically Unattended Machinery Space (PUMS) operations until Classification Society (ABS) re-issues Class Certificate with ACCU designation and confirms proper operation of the automated control, monitoring, and management system. 46 CFR 62.50
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 20 June 2017
Resolution: ABS Survey Manager Survey Status Report with print date: Wed Sep 11 03:11:05 CDT 2019, references ACCU notation was dropped until all requirements for PUMS have been met. See special notes.
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 24 July 2009
Resolved
Remove the library from the stairtower to the satisfaction of class.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 August 2009
Resolved 19 February 2010
Resolution: Cleared by ABS Class report SG1792380.
Construction/Loadline › Structures › Deck Plating
Issued 24 July 2009
Resolved
Make permanent repairs to the pipe protection stanchion in way of Fuel Sounding Pipe 7-280-1. Complete to the satisfaction of class.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 July 2012
Resolved 19 February 2010
Resolution: Cleared by ABS class report SG1792380.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 24 July 2009
Resolved
Make permanent repairs to the High Draft Lube Oil pipe for the stern tube, starboard side, in way of the shaft alley escape trunk aft. Correct to the satisfaction of class.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2009
Resolved 19 February 2010
Resolution: Cleared by Class Report SG1792380.
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 20 March 2009
Resolved
Emergency diesel generator does not function in the automactic mode as per the regulation. Engine would shutdown upon a load being applied. Demonstrate proper operation to the satisfaction of class (ABS) prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Resolution: Emergency diesel generator automation tested and found to be in good condition to the satisifaction of the attending Class Society.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 March 2009
Resolved
OPP laundry spaces need to be overhauled: Light fixtures are not properly secured, A/C drain line located above a electrical distribution panel and leaking (Prohibited), and the power panel ground detector lights and fuse holder are broken. Room shall be tagged out until repairs are made to the satisfaction of class
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 22 June 2009
Resolution: This defincency not resolved. It involves two seperate spaces and is being re-written to reflect the differences.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 20 March 2009
Resolved
Performance general housekeep in the shaft alley space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 22 June 2009
Engineering › Feedwater/Condensate Water System › Valve
Issued 20 March 2009
Resolved
Repair leaking steam valve IWO the condensing piping , engineroom portside.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 22 June 2009
Engineering › Fuel Oil Service System › Flange
Issued 20 March 2009
Resolved
Repair leaking F/O suction flange from the settling tank to the purifier, stbd side engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 22 June 2009
Fire Fighting › Structural - A Class Divisions › Doors
Issued 9 March 2009
Resolved
Numerous joiner doors in accomodation areas are not latching closed. Make suitable adjustments or repairs to ensure doors latch in the closed position. See CG worklist attached to activity for doors in question.
Action required: 705 - Other - as specified
Due 23 June 2009
Resolved 22 June 2009
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 9 March 2009
Resolved
Public deck toilets in accommodation spaces are in a neglected and unsanitary state for use. Several are beyond use as toilet and washroom spaces. Address these spaces for proper repairs and proper sanitation. See attached CG Worklist for listing of toilet/washrooms in need of repair.
Action required: 705 - Other - as specified
Due 30 August 2009
Resolved 30 September 2010
Fire Fighting › Ventilation Systems › Ducts
Issued 9 March 2009
Resolved
Ventilation dampers located through out ship were inspected & documented by ships force in February of 2009. Numerous vent dampers were called out for maintenance. This list was verified by USCG during May-June 2009 dry-dock & maintenance issues are still outstanding. Using ship generated list, make suitable repairs to dampers listed with maintenance deficiencies.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 20 July 2009
Resolution: Cleared.
Lifesaving › Lifeboat › Safety Belt
Issued 9 March 2009
Resolved
Lifeboats 1 thru 5 where inspected and found with numerous deficiencies, to numerous to document with this system. Make all necessary repairs to lifesaving equipment. See CG Worklist attached to activity
Action required: 705 - Other - as specified
Due 23 June 2009
Resolved 22 June 2009
Resolution: Many items resolved, will be re-written to address inoperable marker and compass lights.
Fire Fighting › Fire Main › Valves
Issued 9 March 2009
Resolved
Repair three (3) leaking firemain valves, #66 , 69, 70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2009
Resolved 22 June 2009
Resolution: Valves repaired
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Control Valves
Issued 9 March 2009
Resolved
Repair leaking AFFF motor actuated valve AF313 located in access trunk E-263-0, pipe drain stop valve for this system (located in cargo hold E) dumps on motor actuated valve, repair loose stop valve and install length of pipe to direct flow to bilge well
Action required: 705 - Other - as specified
Due 23 June 2009
Resolved 22 June 2009
Resolution: Valve repaired
Deck/Cargo › Holds/Tanks › Coaming
Issued 9 March 2009
Resolved
Tested hydraulic watertight cargo hold doors with the following deficiencies: WTD E-227-2 Repair leaking hydraulic line fittings located above door / WTD E-263-2 Repair leaking hydraulic fittings located in way of fwd hold door control station. Make proper repairs to door hydraulic systems, clean excessive oil on deck and from around machinery (slip & fire hazard)
Action required: 705 - Other - as specified
Due 30 August 2009
Resolved 24 July 2009
Resolution: Repairs completed.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 9 March 2009
Resolved
Make repairs to all leaking hydraulic deck machinery on focsle' Numerous control valves, fittings & actuators are wrapped w/ oil soaked rags. Repair leaking bearing seals on both achor windlasses & starboard mooring winch.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 22 July 2009
Resolution: Repaired.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 9 March 2009
Resolved
Repair all leaking hydraulic valves located in windlass machinery room. Numerous rag wrapped valves, valves with drips, & valves w/ buckets catching drippings. Remove puddle of hydraulic oil from under portside main pump #10
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 22 July 2009
Resolution: Repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 March 2009
Resolved
OPP laundry space : Make repairs to light fixtures that are not properly secured and lack protective covers.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 22 July 2009
Resolution: Renewed
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 March 2009
Resolved
OPP laundry space: Make proper repairs to power panel ground detector lights and fuse holder that are melted. Make proper repairs to power panel door that does not close.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 22 July 2009
Resolution: Renewed
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 March 2009
Resolved
AFSB laundry space 02-151-4: A/C drain lines located above electrical power switches. Re-route drain lines away from switches.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 22 July 2009
Resolution: Cleared.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 9 March 2009
Resolved
AFSB Laundry space 02-151-4: Heavy condensation and high heat problems noted during inspection, heat problems improperly addressed utilizing stand alone air conditioners. Make suitable repairs to safely provide adequate ventilation to space and installed dryers.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 24 July 2009
Resolution: Cleared at JAC.
Fire Fighting › Ventilation Systems › Fans
Issued 9 March 2009
Resolved
Complete fabricate of suitable closure for vent opening that serves fan 01-187-3. Vent opening located above AFFF hose reel, just aft of starboard accomodation ladder.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 30 June 2009
Lifesaving › Lifeboat › Lamp (outside)
Issued 9 March 2009
Resolved
Repair inoperable white marker lights on lifeboats 1, 2, 3, & freefall boat.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2009
Resolved 29 June 2009
Resolution: New water lights installed
Lifesaving › Lifeboat › Lamp (inside)
Issued 9 March 2009
Resolved
Repair inoperable compass light on lifeboat 1 & 3, compass can be illuminated utilizing LB's interior lighting however the compasses are rigged with internal lights which must work.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2009
Resolved 24 July 2009
Resolution: Lights repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 March 2009
Resolved
Deck E Pump room: Properly terminate or remove old pump motor wiring iwo of newly installed bilge/ballast (Wilden) vacuum pumps.
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 30 June 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 March 2009
Resolved
Deck E Pump room: Use a junction box to properly connect and enclose electrical wires leading to solenoid valve for bilge/ballast Wilden vacuum diaphram pumps.
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 30 June 2009
Stability › Unintentional Flooding › General
Issued 9 March 2009
Resolved
Lower AMR2: Remove approx 60,000 gallons of flooding water from space caused by leaking shipyard supply line to AC chiller units, make neccessary inspections and repairs.
Action required: 705 - Other - as specified
Due 9 June 2009
Resolved 15 June 2009
Resolution: Repair work to airconditioning machinery to be determined.
Deck/Cargo › Ballast › Valves
Issued 9 March 2009
Resolved
Make proper repairs to ballast control system to comply with authorized level of automation and manning prior to the carriage of cargo. The Master shall make suitable arrangements for manning based on level of manual input needed to effectively and safely maintain the vessel's sea keeping stability.
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 20 July 2009
Resolution: Operation satisfactory.
Engineering › Thrusters › Motor
Issued 9 March 2009
Resolved
Prove proper operation of bow thruster
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 30 June 2009
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Control Valves
Issued 9 March 2009
Resolved
Prove proper operation of three (3) - FWD, AFT, & Helo deck fixed afff systems in accordance w/ operational instructions for system. System supplies foam to cargo hold sprinklers, deck foam flooding, and various hose reel stations throughout ship.
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 17 July 2009
Resolution: Cleared by ABS
Engineering › Bilge Water Management System › Pump
Issued 9 March 2009
Resolved
Prove proper operation of bilge dewatering system in automatic mode.
Action required: 705 - Other - as specified
Due 20 July 2009
Resolved 24 July 2009
Resolution: Major Non-conformity written. Operation by manual control.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 9 March 2009
Resolved
Make repairs to and prove proper operation of Main Diesel Engine
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 30 June 2009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 March 2009
Resolved
OPPS Laundry Space: Replace or repair power panel ground detector lights and fuse holder that were damaged from previous laundry room fire.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 22 July 2009
Resolution: Renewed.
Engineering › Steering Gear System › Ram Seal
Issued 4 August 2008
Resolved
Make sat repair on steering ram seal by completion of next drydock scheduled APR2009 NLT completion of 01JUN2009.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 June 2009
Resolved 22 June 2009
Resolution: Seals replaced
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 4 August 2008
Resolved
Make sat repairs and tests to #1 and 2 aux boiler relief valves to the satisfaction of class society
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 14 October 2008
Resolution: Class survey reviewed clearing Deficiency.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 August 2008
Resolved
Properly restencil liferings and replace all marked retro reflective tape with vessel name and homeport.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 14 October 2008
Resolution: Life rings inspected and found to be satisfactory.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 4 August 2008
Resolved
Make hospital space for crew clean and not berthing for MILDET personnel when attached to the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 14 October 2008
Resolution: Hospital space inspected and found to be satisfactory.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 July 2007
Resolved
Content meter low pressure inlet switch inoperative (allows sample valve to be closed without stopping overboard discharge). Vsl is to retain all oily bilge water onboard for disposal to reception facility until repaired and tested for proper operation to the satisfaction of ABS surveyor.
Condition: Unknown
Due 16 August 2007
Resolved 20 July 2007
Resolution: ABS Country Manager / Surveyor [name withheld] tested OWS satisfactory.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 July 2007
Resolved
Make permanent/proper repairs to low pressure salt water inlet piping for #3 generator cooling water. Repairs to be verified by attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Due 16 August 2007
Resolved 1 September 2007
Resolution: ABS verified repairs.
Engineering › Steam Boiler (auxiliary/waste heat) › Outer Casing
Issued 14 July 2007
Resolved
Chief Engineer informed inspector of repairs and problems with both Aux Boilers, including details of weld repairs to cracking, and failure of annuluar seals. Provide US Coast Guard with report concerning boiler problems, repairs, and attestation by ABS surveyor of proper repairs made.
Condition: Improper Installation
Due 30 September 2007
Resolved 16 January 2008
Resolution: SAFENET reports attest to proper repairs.
Construction/Loadline › Structures › Door
Issued 14 July 2007
Resolved
Replace missing/degraded coaming on power operated watertight door to steering flats. Gasket material missing in sections on both sides of door sealing surfaces.
Condition: Improper/Lack of Maintenance
Due 16 August 2007
Resolved 28 September 2007
Resolution: ABS cleared def.
Engineering › Diesel Engine (auxiliary) › Bearing
Issued 14 July 2007
Resolved
#2 MDG bearing has serious oil leak, temporary shielding put in place around the shaft to minimize spray. Submit proposal with timeline for bearing replacement, ensure hourly wipe-ups to prevent fire and slip hazards.
Condition: Improper/Lack of Maintenance
Due 16 August 2007
Resolved 29 July 2007
Resolution: Ship''s crew replaced bearing.
Lifesaving › Launching Appliances › Falls
Issued 31 March 2006
Resolved
Complete overload weight test to #4 lifeboat davit prior to completion of dockside availability in Charleston SC.
Action required: 705 - Other - as specified
Resolved 28 July 2006
Resolution: Received documentary proof satisfying the requirement.
Lifesaving › Launching Appliances › Davit
Issued 31 March 2006
Resolved
Ensure proper operation of #4 lifeboat and #4 lifeboat davit assembly prior to completing dockside availability in Charleston SC.
Action required: 705 - Other - as specified
Resolved 28 July 2006
Resolution: Received document proof satisfying the requirement.
Electrical › Electric Generation Source (emergency) › Switch
Issued 19 February 2003
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY GENERATOR, TO INCLUDE AUTO START WHEN LOAD LOST AT MAIN BUSS. DURING EXPLOSIVE LOAD OUT THE GENERATOR SPACE WILL BE MANNED BY A QUALIFIED ENG CAPABLE OF PLACING GENERATOR ON THE LINE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2003
Resolved 22 February 2003
Resolution: ABS SURVEYOR WITNESSED SATISFACTORY TEST OF SYSTEM.
Fire Fighting
Issued 19 July 2001
Resolved
PROVIDE A VESSEL FIRE CONTROL AND SAFETY PLAN FOR APPROVAL USING THE REQUIRED IMO SYMBOLS.
Condition: Unknown
Due 1 March 2002
Resolved 25 February 2002
Resolution: Reviewed and approved IMO fire plan.
Fire Fighting
Issued 21 June 2001
Resolved
SUBMIT FOR AN APPROVAL THE VESSEL'S FIRE CONTROL PLAN USING THE REQUIRE IMOSYMBOLS. VESSEL DOES NOT HAVE AN APPROVED FIRE CONTROL PLAN. _x001C_ _x001C_
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Electrical
Issued 28 March 2001
Resolved
INSTALL PERMANENT COMMUNICATIONS (SOUND POWERED PHONE SYSTEM) AT MAIN ENGINE LOCAL CONTROL IAW 46CFR62.25-10.
Condition: Unknown
Due 28 March 2001
Resolved 28 March 2001
Lifesaving
Issued 28 March 2001
Resolved
RE-CONFIGURE AND PERMANENTLY ATTACH AFT 02DECK JACOBS LADDERS (PORT & STBD,FRAME, 168). LADDERS SHALL BE CONFIGURATION AND ATTACHED TO DECK IN SUCH AWAY THAT A SINGLE PERSON CAN RELEASE AND DISEMBARK VESSEL, IAW 46CFR199.110(F)(3)(4) AND 46CFR199.261(E).
Condition: Unknown
Due 28 March 2001
Resolved 28 March 2001
Engineering
Issued 28 March 2001
Resolved
MAKE REPAIRS TO BOW THRUSTER UNABLE TO OPERATIONAL FROM BRIDGE, HAVE LOCAL CONTROL AS PER CONDITION OF CLASS (ABS). UPON COMPLETION OF REPAIRS TO SATISFACTION OF CLASSIFICATION SURVEYOR, PROVIDE DOCUMENTATION TO CLOSEST [name withheld] USE SUFFICIENT TUGS WHEN ENETER ANY US PORT
Condition: Unknown
Due 28 March 2001
Resolved 28 March 2001
Fire Fighting
Issued 28 March 2001
Resolved
UPDATE VESSELS FIRE CONTROL PLANS, WHICH INCLUDE FIREMAN SYSTEM MODIFICATIONS (AS PER ITEM 1), AND WATER TIGHT DOOR AT FRAME 169, D DECK, IAW 46CFR97.36-1 & SOLAS 74/78 CHAPTER II-2/20.
Condition: Unknown
Due 28 March 2001
Resolved 28 March 2001
Fire Fighting
Issued 28 March 2001
Resolved
MAKE MODIFICATIONS TO ENGINE ROOM FIREMAIN SYSTEM PIPING IN ORDER TO COMPLY WITH SOLAS 74/78 CHAPTER II-2/4.6.3. ALL DRAWINGS, WORK AND TESTS SHALL BE APPROVED BY CLASSIFICATION SOCIETY.
Condition: Unknown
Due 28 March 2001
Resolved 28 March 2001
Deck/Cargo
Issued 1 November 1999
Resolved
REPAIR/REPLACE AS ORIGINAL DECK MOORING MACHINERY PUMP # 14.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Engineering
Issued 1 November 1999
Resolved
SET WASTE HEAT BOILER SAFETY. LOG IN OFFICIAL ENGINE ROOM LOG AND PROVIDE FAX COPY TO [name withheld].
Condition: Unknown
Due 16 November 1999
Resolved 8 December 1999
Lifesaving
Issued 1 November 1999
Resolved
REPAIR & PROVE THE FOLLOWING GEN ALARMS LTS & BELLS:LTG 01-5,FR 125P;LTG 2B, FR 264; BELLS OLD BRIDGE FR 202;OUTSIDE RADIO SHACK; 4D STBD, FR 213; 4C, FR 215; 4C, FR 227; 4B, FR 227(20); O3, FR 188; OUTSIDE CARGO LAUNDRY; O4, FR 207; COOLER RM; P GEN RM; @ SHFT ALLEY ENTRANCE, MACHY SPACE.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Documentation
Issued 1 November 1999
Resolved
PROVIDE CG APPROVED PLANS FOR MOORING SYSTEM MODIFICATIONS AND TO INSTALLEDW/T DOOR AT FRAME #169, "D" DECK TO [name withheld].
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Lifesaving
Issued 1 November 1999
Resolved
PROVIDE GENERAL ALARMS AS NEEDED TO O1 WEATHER DECK ABOVE #5 CARGO HOLD.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Construction/Loadline
Issued 1 November 1999
Resolved
PROVE W/T DOOR NEXT TO CO2 ROOM AFTER REPAIRS IN MANUAL, REMOTE AND CO2 DISCHARGE PRESSURE SWITCH MODES. DOOR SHALL REMAIN CLOSED THROUGHOUT ENTIREVOYAGE.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Navigation
Issued 1 November 1999
Resolved
PROVIDE A CURRENT MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Deck/Cargo
Issued 1 November 1999
Resolved
REPAIR AND PROVE LEAKING FLANGE TO ANCHOR WINDLASS HYDRAULIC LINE INWAY OF BOSUN STORE OVERHEAD.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Deck/Cargo
Issued 1 November 1999
Resolved
REPAIR AND PROVE LEAKING FLANGE TO ANCHOR WINDLASS WATER WASHDOWN LINE INWAY OF BOSUN STORES OVERHEAD, PORTSIDE.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Engineering
Issued 1 November 1999
Resolved
CONDUCT OVERSPEED TRIP TO MAIN PROPULSION ENGINE, LOG IN OFFICIAL ENGINE ROOM LOG AND PROVIDE FAX COPY TO [name withheld].
Condition: Unknown
Due 16 November 1999
Resolved 8 December 1999
Engineering
Issued 1 February 1999
Resolved
MAKE PERMANENT REPAIRS TO 12 INCH CRACK IN #1 AUX BOILER CASING, TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR, PRIOR TO OPERATING THE BOILER.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Navigation
Issued 3 December 1998
Resolved
REPAIR DIGITAL DISPLAY FOR VESSEL'S ECHO DEPTH SOUNDER ON THE NAVIGATION BRIDGE.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Lifesaving
Issued 3 December 1998
Resolved
PROVIDE REQUIRED AUXILIARY LINE FOR LINE THROWING APPARATUS.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 3 December 1998
Resolved
PROVE PROPER OPERATION OF THE REVERSE POWER RELAY TRIPS FOR SHIP'S SERVICE MAIN DIESEL GENERATORS #1 AND #3.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Navigation
Issued 3 December 1998
Resolved
CORRECT FIVE DEGREE ERROR IN RUDDER ANGLE INDICATOR ON THE NAVIGATION BRIDGE.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 3 December 1998
Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY WIRING ON FLYING BRIDGE COMPASS LIGHT.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Engineering
Issued 3 December 1998
Resolved
MAKE PROVISIONS TO TIE IN THE #1 AUXILIARY BOILER ALARMS TO THE AUTOMATION CONSOLE AND PROVE PROPER OPERATION OF THE AUTOMATION.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Engineering
Issued 2 January 1998
Resolved
Open double bottom fuel oil tanks 8-227-(19)-1 and 8-227-(19)-2 for inspection to insure steam tracing system meet approved plans and is not cross connected to the tank heating system.
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Engineering
Issued 2 January 1998
Resolved
No fuel oil with a flash point of less than 171 degrees farenheit shall be carried on double bottom fuel oil tanks 8-227-(19)-1 and 8-227-(19)-2. Thisrequirement shall be strictly adhered to until the uncontrolled heating temperatures are properly corrected.
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Engineering
Issued 2 January 1998
Resolved
Repair uncontrolled heating temperatures of double bottom fuel tanks 8-227-(19)-1 and 8-227-(19)-2. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Engineering
Issued 11 November 1997
Resolved
SUBMIT REPAIR PROPOSAL TO CORRECT UNCONTROLLED HEAT RISE IN DB F/O TANKS 8-227-(19)-1 & 2 WHEN STEAM TRACING SYSTEM IS IN USE. AT A MINIMUM THIS SHALLINCLUDE AN INSPECTION OF TANKS STEAM TRACING PIPING TO SHOW LINES ARE NOT X-CONNECTED TO TANKS HEATING SYSTEM.
Condition: Unknown
Due 11 November 1997
Resolved 11 November 1997
Engineering
Issued 11 November 1997
Resolved
UNTIL UNCONTROLLED HEATING PROBLEM HAS BEEN ADDRESSED AND CORRECTED DOUBLE BOTTOM FUEL TANKS 8-227-(19)-1 & 2 ARE RESTRICTED FROM FUELS WITH A FLASH POINT BELOW 171 DEGREES FAHRENHEIT.
Condition: Unknown
Due 11 November 1997
Resolved 11 November 1997