MAURY USCG vessel records
← All vessels

MARIETTA

Built
1957
Last inspected
8 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 December 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WJ6405
Flag
UNITED STATES
Maury page id
psix-43356

Documentation record

Registered dimensions (L × B × D)94.7 ft × 30.0 ft × 7.2 ft
Registered tonnagegross 90 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALAMEDA, CA, UNITED STATES · built 1957
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 17 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 28 inspections, each with its date, unit and type; 45 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

8 December 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8279381
23 April 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8117705
10 February 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8077596
22 November 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8038780
23 September 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8009343
26 February 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7870544
27 November 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7830262
2 October 2023 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7802205
30 May 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7701113
14 May 2023 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7690066
14 May 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7707996
29 November 2022 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7601264
10 January 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7378284
13 September 2021 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7311660
28 July 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7271154
9 December 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7108988
2 December 2019 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6865590
5 September 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6814854
23 August 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6792332
19 November 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6583706
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6537820
27 November 2017 Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6313287
20 September 2017 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6271206
6 August 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6251569
6 January 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6080548
7 December 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6054243
22 September 2016 Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6007225
18 February 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5825071

Deficiency record · 45

09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 10 February 2025 Resolved
Provision shall be made to prevent entrance into the tank of any contaminating substance. The potable water pipe did not have a lock on it allowing access to any passengers onboard. 21CFR1250.82
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 March 2025
Resolution: Rcvd documentation that the lock was installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector (MI) found dead-end wire near starboard generator. Properly dead-end wire in accordance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2024 Resolved
Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries. Ventilation must be provided in accordance with § 111.15–10 in subchapter J of this chapter. MI found battery for starboard MDE was not properly secured. Secure battery in accordance with regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2024 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found exhaust fan in engine room without a cover. Replace cover in accordance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 26 February 2024 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. MI found the light for the compass on the bridge was inoperable. Fix compass light in accordance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2024 Resolved
Notwithstanding the provisions in paragraph (b) of this section, 406.0–406.1 MHz EPIRBs must meet all the technical and performance standards contained in RTCM 11000 (incorporated by reference, see § 80.7), and must also comply with the standards specified in § 80.1101(c)(5). MI found the EPIRB box was not checked on the appropriate certificate. Have box checked in accordance with regulations. 47 CFR 80.1061
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 11 March 2024
Resolution: Received photo of amended cert
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2024 Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Mi found 02 hole in the aft bulkhead of the engine room that were open. Fix in accordance with regulations. 46 CFR 171.117 Old-T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 27 November 2023 Resolved
Observed three cut-outs in the vessels hull-two forward STBD side of the engine RM (3’X2’) and STB AFT of the engine room (6’x5’)- see images in documents. Vessel is to provide a repair plan, prior to installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2023
Resolution: Installed new hull plating
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2023 Resolved
Observed a modified flange shaft on the STBD side that connects to the reduction gear. Vessel is to provide a repair plan or replace flange/s (including from prime mover, if modified) or manufacturer specifications.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2023
Resolution: An observation was made on the existing flange/coupling from the reduction gear (6 Bolt) to determined that the existing (STBD shaft) will not affect the function of the shaft or fastening strength.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 November 2023 Resolved
Vessel is in progress of a re-power for both propulsion and generator engines. All are currently removed and pending document reviews prior to installation. Vessel is to provide the necessary documents and complete a full power trial prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2023
Resolution: Vessel completed re-power and conducted underway checks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2023 Resolved
Discovered corrosion on starboard black water pipe in the space forward of lazarette. Clean up corrosion on black water pipe for inspection. To be rectified prior to receiving credit internal structural exam credit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 19 October 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 May 2023 Resolved
02 fire stations did not have spanner wrenches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 22 June 2023
Resolution: Received photos of new spanner wrenches on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 30 May 2023 Resolved
01 IBA was permanently attached to the vessel. Remove IBA's permanent attachment to vessel.
Action required: 10 - Deficiency Rectified
Resolved 30 May 2023
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 May 2023 Resolved
On May 14th, The Marietta lost the ability to maneuver the vessel in reverse while they were mooring and subsequently allided with the CORONADO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2023
Resolution: MI's witnessed satisfactory operation
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2022 Resolved
Flammable liquids found stored in engine room. Provide proper storage facility for flammable/combustible liquids.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Discussed w/ Josh Gaylord that diesel fuel in kept in portable 2 gallon tanks for servicing F/O RACOR filters must be properly stored while in engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2022 Resolved
Unapproved waste receptacles found in engine room. Replace with the approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Receptacles removed from engine room; Approved receptacles on order.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 November 2022 Resolved
Fire main discharge pressure gauge indicated 25 PSI with both fire hoses energized, and 40 PSI with a single fire hose. Make necessary repairs to provide adequate PSI of 50.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Witnessed operational test w/ 02 charged hoses; ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 29 November 2022 Resolved
IBA's found to be removed from vessel for servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2022
Resolution: Vessel acquired 04 replacement IBAs with a total capacity of 200 persons while their normal IBAs are being serviced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 November 2022 Resolved
Several fire extinguishers found with missing servicing tags attached. Provide servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Verified portable fire extinguishers service tags.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 November 2022 Resolved
Electrical deck matting missing from switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Electrical matting found in proper placement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2022 Resolved
Provide 21 new Type-I adult lifejackets. Passenger count reduced by 21 persons.
Action required: 705 - Other - as specified
Resolved 8 March 2022
Resolution: Provided 21 new Type-I adult lifejackets - verified by MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2022 Resolved
Properly install fixed ice machine and ventilation switch in main deck aft storage space. (Fixed equipment shall have permanent electrical connections)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 24 February 2022
Resolution: Received picture of corrected eletrical installation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2022 Resolved
Provide burn dressing found expired in first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 8 March 2022
Resolution: Received reciept via e-mail.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 January 2022 Resolved
Replace expired battery in EPIRB.
Action required: 10 - Deficiency Rectified
Due 10 January 2022
Resolved 10 January 2022
Resolution: Maintenance personnel brought EPIRB to Oceans West for immediate servicing. EPIRB back on board before inspection was completed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 28 July 2021 Resolved
Both IBA lcoated on bridgewings painter line not properly secured to hydrostatic float-free unit.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 July 2021
Resolved 28 July 2021
Resolution: Deficiency corrected in the presence of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 December 2020 Resolved
Provide vessel with 01 additional smoke distress signal.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 December 2020
Resolved 9 December 2020
Resolution: Vessel rep provided additional distress signal.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 December 2020 Resolved
Provide vessel's DSC VHF radio with lat/long input.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Vessel rep connected correct wire and restored lat/long input.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 December 2019 Resolved
Replace retro on 16 adult size life jackets. (PAX count reduced to 467) replace 06 condemned adult lifejackets.
Action required: 705 - Other - as specified
Resolved 4 December 2019
Resolution: replaced with new
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 December 2019 Resolved
Reinstall IBAs after servicing prior to any offshore operations.
Action required: 705 - Other - as specified
Resolved 12 December 2019
Resolution: IBAs serviced and onboard for immediate use.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2019 Resolved
Remove or properly cap dead end wire found at main switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 12 December 2019
Resolution: Wires removed from cable run.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 December 2019 Resolved
Repair pinhole bilge pipe at 1st flange at pump and corroded section at fire pump / bilge pump crossover piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 12 December 2019
Resolution: Replaced and pressure tested new piping runs for Bilge / Fire main crossover. TEST sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2019 Resolved
Provide proper spanner wrenches at E/R and 2nd deck hydrants.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 4 December 2019
Resolution: provided new wrenches
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 2 December 2019 Resolved
Provide blocking / bracing for battery boxes in E/R prior to offshore ops.
Action required: 705 - Other - as specified
Resolved 12 December 2019
Resolution: All battery boxes have been replaced or existing batteries secured with bracing.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 December 2019 Resolved
Replace 02 fire hoses found with leaks.
Action required: 10 - Deficiency Rectified
Resolved 3 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2019 Resolved
Repair anchor light prior to any night time operations.
Action required: 705 - Other - as specified
Resolved 4 December 2019
Resolution: Light repaired
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 December 2019 Resolved
Prove proper operation of emergency lighting system prior to any nighttime operations.
Action required: 705 - Other - as specified
Resolved 4 December 2019
Resolution: E lighting operational
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 November 2018 Resolved
Properly dead end wires or remove; next to portside engine and battery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 19 March 2019
Resolution: Dead ended wires are removed
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 November 2018 Resolved
Properly label escape hatches in engine room
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 19 March 2019
Resolution: Hatches properly labeled
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 November 2018
Resolution: Verified in VIVS
Communications › Radio Communications › EPIRB
Issued 27 November 2017 Resolved
Provide EPIRB with good battery. Restricted to 3nm.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 30 November 2017
Resolution: New EPIRB installed.
Engineering › Bilge Water Management System › Eductor
Issued 27 November 2017 Resolved
Prove proper operation of bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2017
Resolved 30 November 2017
Resolution: Proper operation of bilge system proved.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 November 2017 Resolved
Remove wires from bilge in engine room.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 30 November 2017
Resolution: Wires properly secured and removed from bilges.
Communications › Audible Communications › Bell
Issued 27 November 2017 Resolved
Provide bell IAW nav rules.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 30 November 2017
Resolution: Bell provided IAW nav rules.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 November 2017 Resolved
Cap dead end wire in engine room.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 30 November 2017
Resolution: Dead end wire capped.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 December 2016 Resolved
Provide 09 additional adult life jackets.
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 7 December 2016
Resolution: 09 adult lifejackets were purchased and placed in service onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.