Inspection history · 28
8 December 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8279381
23 April 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8117705
10 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8077596
22 November 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8038780
23 September 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8009343
26 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7870544
27 November 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7830262
2 October 2023
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7802205
30 May 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7701113
14 May 2023
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7690066
14 May 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7707996
29 November 2022
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7601264
10 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7378284
13 September 2021
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7311660
28 July 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7271154
9 December 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7108988
2 December 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6865590
5 September 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6814854
23 August 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6792332
19 November 2018
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6583706
11 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6537820
27 November 2017
Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6313287
20 September 2017
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6271206
6 August 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6251569
6 January 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6080548
7 December 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6054243
22 September 2016
Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6007225
18 February 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5825071
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 10 February 2025
Resolved
Provision shall be made to prevent entrance into the tank of any contaminating substance. The potable water pipe did not have a lock on it allowing access to any passengers onboard. 21CFR1250.82
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 March 2025
Resolution: Rcvd documentation that the lock was installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector (MI) found dead-end wire near starboard generator. Properly dead-end wire in accordance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2024
Resolved
Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries. Ventilation must be provided in accordance with § 111.15–10 in subchapter J of this chapter. MI found battery for starboard MDE was not properly secured. Secure battery in accordance with regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found exhaust fan in engine room without a cover. Replace cover in accordance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 26 February 2024
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. MI found the light for the compass on the bridge was inoperable. Fix compass light in accordance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2024
Resolved
Notwithstanding the provisions in paragraph (b) of this section, 406.0–406.1 MHz EPIRBs must meet all the technical and performance standards contained in RTCM 11000 (incorporated by reference, see § 80.7), and must also comply with the standards specified in § 80.1101(c)(5). MI found the EPIRB box was not checked on the appropriate certificate. Have box checked in accordance with regulations. 47 CFR 80.1061
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 11 March 2024
Resolution: Received photo of amended cert
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2024
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Mi found 02 hole in the aft bulkhead of the engine room that were open. Fix in accordance with regulations. 46 CFR 171.117 Old-T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 1 March 2024
Resolution: Owner provided proof of correction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 27 November 2023
Resolved
Observed three cut-outs in the vessels hull-two forward STBD side of the engine RM (3’X2’) and STB AFT of the engine room (6’x5’)- see images in documents. Vessel is to provide a repair plan, prior to installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2023
Resolution: Installed new hull plating
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2023
Resolved
Observed a modified flange shaft on the STBD side that connects to the reduction gear. Vessel is to provide a repair plan or replace flange/s (including from prime mover, if modified) or manufacturer specifications.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2023
Resolution: An observation was made on the existing flange/coupling from the reduction gear (6 Bolt) to determined that the existing (STBD shaft) will not affect the function of the shaft or fastening strength.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 November 2023
Resolved
Vessel is in progress of a re-power for both propulsion and generator engines. All are currently removed and pending document reviews prior to installation. Vessel is to provide the necessary documents and complete a full power trial prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2023
Resolution: Vessel completed re-power and conducted underway checks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2023
Resolved
Discovered corrosion on starboard black water pipe in the space forward of lazarette. Clean up corrosion on black water pipe for inspection. To be rectified prior to receiving credit internal structural exam credit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 19 October 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 May 2023
Resolved
02 fire stations did not have spanner wrenches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 22 June 2023
Resolution: Received photos of new spanner wrenches on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 30 May 2023
Resolved
01 IBA was permanently attached to the vessel. Remove IBA's permanent attachment to vessel.
Action required: 10 - Deficiency Rectified
Resolved 30 May 2023
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 May 2023
Resolved
On May 14th, The Marietta lost the ability to maneuver the vessel in reverse while they were mooring and subsequently allided with the CORONADO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2023
Resolution: MI's witnessed satisfactory operation
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2022
Resolved
Flammable liquids found stored in engine room. Provide proper storage facility for flammable/combustible liquids.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Discussed w/ Josh Gaylord that diesel fuel in kept in portable 2 gallon tanks for servicing F/O RACOR filters must be properly stored while in engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2022
Resolved
Unapproved waste receptacles found in engine room. Replace with the approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Receptacles removed from engine room; Approved receptacles on order.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 November 2022
Resolved
Fire main discharge pressure gauge indicated 25 PSI with both fire hoses energized, and 40 PSI with a single fire hose. Make necessary repairs to provide adequate PSI of
50.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Witnessed operational test w/ 02 charged hoses; ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 29 November 2022
Resolved
IBA's found to be removed from vessel for servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2022
Resolution: Vessel acquired 04 replacement IBAs with a total capacity of 200 persons while their normal IBAs are being serviced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 November 2022
Resolved
Several fire extinguishers found with missing servicing
tags attached. Provide servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Verified portable fire extinguishers service tags.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 November 2022
Resolved
Electrical deck matting missing from switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2022
Resolution: Electrical matting found in proper placement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2022
Resolved
Provide 21 new Type-I adult lifejackets. Passenger count reduced by 21 persons.
Action required: 705 - Other - as specified
Resolved 8 March 2022
Resolution: Provided 21 new Type-I adult lifejackets - verified by MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2022
Resolved
Properly install fixed ice machine and ventilation switch in main deck aft storage space. (Fixed equipment shall have permanent electrical connections)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 24 February 2022
Resolution: Received picture of corrected eletrical installation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2022
Resolved
Provide burn dressing found expired in first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 8 March 2022
Resolution: Received reciept via e-mail.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 January 2022
Resolved
Replace expired battery in EPIRB.
Action required: 10 - Deficiency Rectified
Due 10 January 2022
Resolved 10 January 2022
Resolution: Maintenance personnel brought EPIRB to Oceans West for immediate servicing. EPIRB back on board before inspection was completed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 28 July 2021
Resolved
Both IBA lcoated on bridgewings painter line not properly secured to hydrostatic float-free unit.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 July 2021
Resolved 28 July 2021
Resolution: Deficiency corrected in the presence of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 December 2020
Resolved
Provide vessel with 01 additional smoke distress signal.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 December 2020
Resolved 9 December 2020
Resolution: Vessel rep provided additional distress signal.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 December 2020
Resolved
Provide vessel's DSC VHF radio with lat/long input.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 9 December 2020
Resolution: Vessel rep connected correct wire and restored lat/long input.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 December 2019
Resolved
Replace retro on 16 adult size life jackets. (PAX count reduced to 467) replace 06 condemned adult lifejackets.
Action required: 705 - Other - as specified
Resolved 4 December 2019
Resolution: replaced with new
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 December 2019
Resolved
Reinstall IBAs after servicing prior to any offshore operations.
Action required: 705 - Other - as specified
Resolved 12 December 2019
Resolution: IBAs serviced and onboard for immediate use.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2019
Resolved
Remove or properly cap dead end wire found at main switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 12 December 2019
Resolution: Wires removed from cable run.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 December 2019
Resolved
Repair pinhole bilge pipe at 1st flange at pump and corroded section at fire pump / bilge pump crossover piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 12 December 2019
Resolution: Replaced and pressure tested new piping runs for Bilge / Fire main crossover. TEST sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2019
Resolved
Provide proper spanner wrenches at E/R and 2nd deck hydrants.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 4 December 2019
Resolution: provided new wrenches
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 2 December 2019
Resolved
Provide blocking / bracing for battery boxes in E/R prior to offshore ops.
Action required: 705 - Other - as specified
Resolved 12 December 2019
Resolution: All battery boxes have been replaced or existing batteries secured with bracing.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 December 2019
Resolved
Replace 02 fire hoses found with leaks.
Action required: 10 - Deficiency Rectified
Resolved 3 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2019
Resolved
Repair anchor light prior to any night time operations.
Action required: 705 - Other - as specified
Resolved 4 December 2019
Resolution: Light repaired
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 December 2019
Resolved
Prove proper operation of emergency lighting system prior to any nighttime operations.
Action required: 705 - Other - as specified
Resolved 4 December 2019
Resolution: E lighting operational
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 November 2018
Resolved
Properly dead end wires or remove; next to portside engine and battery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 19 March 2019
Resolution: Dead ended wires are removed
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 November 2018
Resolved
Properly label escape hatches in engine room
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 19 March 2019
Resolution: Hatches properly labeled
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 November 2018
Resolution: Verified in VIVS
Communications › Radio Communications › EPIRB
Issued 27 November 2017
Resolved
Provide EPIRB with good battery. Restricted to 3nm.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 30 November 2017
Resolution: New EPIRB installed.
Engineering › Bilge Water Management System › Eductor
Issued 27 November 2017
Resolved
Prove proper operation of bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2017
Resolved 30 November 2017
Resolution: Proper operation of bilge system proved.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 November 2017
Resolved
Remove wires from bilge in engine room.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 30 November 2017
Resolution: Wires properly secured and removed from bilges.
Communications › Audible Communications › Bell
Issued 27 November 2017
Resolved
Provide bell IAW nav rules.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 30 November 2017
Resolution: Bell provided IAW nav rules.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 November 2017
Resolved
Cap dead end wire in engine room.
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 30 November 2017
Resolution: Dead end wire capped.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 December 2016
Resolved
Provide 09 additional adult life jackets.
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 7 December 2016
Resolution: 09 adult lifejackets were purchased and placed in service onboard.