Inspection history · 26
6 May 2026
Annual Inspection · MSP Additional Oversight - Risk Assessment · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8368163
20 March 2025
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8093125
2 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8041932
25 October 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8027051
30 September 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8012209
5 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7928818
16 August 2023
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7769995
7 June 2023
Annual Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7702098
8 May 2023
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7683611
9 December 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7607034
28 June 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7489752
19 April 2022
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7439402
1 July 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7241349
11 May 2021
Deficiency Check · Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7194723
30 March 2020
COI Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930966
22 October 2019
Construction Oversight · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6839550
22 August 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6791888
25 June 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6725382
8 May 2019
Hull Examination · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6679839
7 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6534778
20 June 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6450290
13 June 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6174518
3 May 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6138022
13 June 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5906531
8 June 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5901380
26 April 2016
Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5863323
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2026
Resolved
Non-conducting mats or grating shall be provided on deck in front and rear of switchboards. Electrical mats missing on 03 switchboards, install non-conducting mats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2026
Resolved 19 May 2026
Resolution: Inspector received photograph of non-conducting mats in front of/rear of switchboards.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2026
Resolved
Equipment mounted on a hinged door of an enclosure shall be constructed or shielded in such a manner that no live parts of the door mounted equipment will be exposed to accidental contact by a person with the door open and circuit energized. Install switch blank in switchboard to shield energized bus bar.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2026
Resolved 19 May 2026
Resolution: Inspector received photograph of blank installed in switchboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2026
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck as per subpart 177.30-7 of this subchapter. Installed emergency lighting in galley did not work; restore to operational condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2026
Resolved 5 June 2026
Resolution: Inspector verified deficiency was corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2026
Resolved
Nameplates. Each nameplate for a circuit breaker must show the electrical load served and the setting of the circuit breaker. Label breakers in switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2026
Resolved 19 May 2026
Resolution: Inspector received photograph of labelling of breakers in switchboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2024
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MI found several lifebuoys with deteriorating lines. Replace life buoys with new ones in accordance with current regulations and notify local OCMI once completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 18 June 2024
Resolution: Received photos from vessel rep showing 3 new life buoys.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 June 2024
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. MI found galley ventilation was cover in grease. Clean vents and notify local OCMI once completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 18 June 2024
Resolution: Received photo of clean galley ventilation.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 16 August 2023
Resolved
Corroded section of STBD shaft log locatined in aft peak void. Hole penetrating into shaft tube and water leaking into void.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 18 August 2023
Resolution: Temp repairs were made and NDT test was conducted.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 August 2023
Resolved
Temporary repairs via doubler plate was installed on the starboard shaft tube after shaft tube was found holed. Company Port Captain requested to Sector San Diego that the doubler plate remain in-place until 15APR2024, with the following conditions:
-Permanent repairs will be made by means of crop and renew on both port and starboard shaft logs, commencing April 2024.
-Vessel will install a bilge alarm for the compartment that the doubler plate is installed.
-Company will continue morning vessel checks, and notify Sector San Diego of any water ingress into compartment.
Sector San Diego agreed to the request and will coordinate an operational test of the bilge alarm.
Action required: 705 - Other - as specified
Due 15 April 2024
Resolved 5 June 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 June 2023
Resolved
The aft upper deck fire station hose was found deteriorated and leaking, Must replace fire hose to satisfaction of USCG.
Action required: 10 - Deficiency Rectified
Due 7 June 2023
Resolved 7 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2023
Resolved
The port side engine room battery bank was found with the batteries unsupported. Must properly mount the batteries to satisfaction of USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 5 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 June 2023
Resolved
The lazarette and ballast compartments were found to have no operable lighting. Must provide both compartments with adequate lighting to satisfaction of the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 5 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 June 2023
Resolved
The lazarette bilge suction was found without a strainer attached. Must provide required strainer to satisfaction of the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 5 June 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 June 2023
Resolved
Marine Employers shall establish programs for the chemical testing for dangerous drugs on a random basis of vessel crewmembers. Must provide list of all vessel crew members on the random chemical testing program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 5 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 July 2021
Resolved
Grab lines on 02 port side ring buoys found to be deteriorated beyond repair as well as the lanyard connecting the water light. Replace 02 life buoys and replace lanyard for water-light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 July 2021
Resolution: Replaced 02 life buoys and replace lanyard for water-light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2021
Resolved
Electrical wire penetrating bulkhead from engine space to galley missing watertight seal. Install watertight seal where wire penetrates bulkhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 2 July 2021
Resolution: Installed watertight seal where wire penetrates bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2021
Resolved
Wire in engine space from switch board found to be unprotected. Cap wire end.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 2 July 2021
Resolution: Removed wire from circuit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2021
Resolved
Wires located on two VHF radios found to be unprotected. Cap wire ends on both radios.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 7 October 2021
Resolution: Corrected
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 1 July 2021
Resolved
VHF-DSC radios found to be operating without MMSI registration. Register MMSI on VHF-DSC radios.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 7 October 2021
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2020
Resolved
Owners/Operators shall conduct inspections/tests of portable fire extinguishers as required by 46 CFR 115.810. One portable fire extinguisher located in galley space had an outdated inspection tag. Vessel operator must provide sufficient evidence that the extinguisher was inspected to the satisfaction of the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of serviced extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 March 2020
Resolved
Vessels which carry more than 150 passengers shall meet the structural fire protection requirements of 46 CFR 72.05. It was discovered that a section of structural fire protection material located on the overhead in the engine space was missing. Must rectify to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of repaired structural fire protection.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 March 2020
Resolved
Vessels which carry more than 150 passengers shall meet the structural fire protection requirements of 46 CFR 72.05. It was discovered that the electrical conduit penetration from the main deck to the engine space had missing fire stop protection. Must rectify to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of sealed deck penetration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2020
Resolved
Vessels are required to carry ring buoys as specified in 46 CFR 117.70. It was discovered that the grab line on the ring buoy located adjacent to the pilot house was in poor condition. Must rectify to the satisfaction of the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of replaced grab line.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2020
Resolved
All ventilation ducts to accommodation spaces must be in good working condition. It was observed that the galley ventilation duct had excess grease build-up. Must rectify to the satisfaction of the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of cleaned and painted ducting.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 30 March 2020
Resolved
All tank ventilation outlets must be in good material condition. Ventilation pipe to the lube oil tank on the port side was fractured. Operator must condemn use of the tank until ventilation pipe has been replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of repaired vent pipe.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019
Resolved
Renew retro tape on 18 identified life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 6 August 2019
Resolution: Retro tape was placed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Replace welding cables on both battery banks with marine cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 6 August 2019
Resolution: Welding cables were replaced with marine grade cables.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Provide main engines with electrical junction box covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 6 August 2019
Resolution: Junction boxes were provided with covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Replace unauthorized 120 volt cable in pilot house with boat cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 6 August 2019
Resolution: Cable was replaced with boat cable.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 September 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 November 2018
Resolution: Verified in VIVS
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 13 June 2017
Resolved
Provide screen for fuel vents.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 12 July 2017
Resolution: 30 by 30 mesh flame screen installed.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 13 June 2017
Resolved
Provide non combustible trash cans throghout vessel.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 16 August 2017
Resolution: No combustable cans purchased.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 June 2017
Resolved
Provide retro tape.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 12 July 2017
Resolution: New life ring purchased, retroreflective tape now in compliance with CFR.
Construction/Loadline › Hull › Hull Plating
Issued 26 April 2016
Resolved
Provide plans and drawings to OCMI for repairs/alterations being conducted on vessel. Plans must include reasons for work, scope of work, condition prior to repair, and plans for repairs including materials to be used. Cease all repair work being conducted on vessel until plans are approved by OCMI
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2016
Resolved 12 May 2016
Resolution: Final hull repairs witnessed by attending MI; all sat.