Records from 1986 to 2026. Most recent: inspection, 6 May 2026.
Inspection history · 120
6 May 2026
Annual Inspection · MSP Additional Oversight - Risk Assessment · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8368163
20 March 2025
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8093125
2 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8041932
25 October 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8027051
30 September 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8012209
5 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7928818
16 August 2023
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7769995
7 June 2023
Annual Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7702098
8 May 2023
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7683611
9 December 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7607034
28 June 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7489752
19 April 2022
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7439402
1 July 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7241349
11 May 2021
Deficiency Check · Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7194723
30 March 2020
COI Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930966
22 October 2019
Construction Oversight · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6839550
22 August 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6791888
25 June 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6725382
8 May 2019
Hull Examination · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6679839
7 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6534778
20 June 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6450290
13 June 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6174518
3 May 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6138022
13 June 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5906531
8 June 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5901380
26 April 2016
Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5863323
27 November 2015
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5771033
2 October 2014
Deficiency Check · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4997854
25 June 2014
Annual Inspection · Security Plan Review - ASP · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4898417
11 June 2012
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4341110
19 January 2010
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3666065
11 January 2010
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3662347
6 April 2009
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3447327
13 May 2008
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3205791
25 June 2007
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2940310
25 April 2007
Construction Oversight · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2910378
8 September 2006
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2975696
21 June 2006
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2674809
5 April 2006
Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2606050
5 April 2006
Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2702532
7 February 2006
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2580725
4 April 2005
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2305447
27 December 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2265761
18 June 2004
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2102525
5 May 2004
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2051187
5 April 2004
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2056237
5 March 2004
MTSA Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2031254
22 December 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1968883
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978154
25 November 2003
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1954275
5 June 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1810354
16 April 2003
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1769322
8 August 2002
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1658351
3 July 2002
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1639387
18 March 2002
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1492908
2 January 2002
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1474796
2 January 2002
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1474814
26 December 2001
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473934
25 December 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1474385
9 May 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387071
29 April 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 12069
28 April 2001
Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384753
26 April 2001
Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1061703
23 April 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 179749
21 October 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 111343
25 April 2000
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427848
12 April 2000
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427849
2 December 1999
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 809821
2 November 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1437633
22 September 1999
Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1346027
20 April 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1402846
9 November 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 805156
21 August 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 6080
30 March 1998
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1381298
28 March 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 56355
13 November 1997
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388410
3 April 1997
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1390490
23 October 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1409588
10 July 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1088009
27 May 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 178492
24 May 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1439740
25 April 1996
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1439751
13 February 1996
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1454301
15 December 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1421065
24 May 1995
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1371098
15 November 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 693827
12 October 1994
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 864757
26 May 1994
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1405539
2 December 1993
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1162969
7 September 1993
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1405422
23 July 1993
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1452964
3 June 1993
Drydock Extension · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1139244
13 November 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 86386
13 November 1992
Examination of Repairs · Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1451823
4 June 1992
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1259641
10 January 1992
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1256627
1 August 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1250847
12 July 1991
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 942891
18 April 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 913037
18 April 1991
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1227307
18 October 1990
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1223036
25 July 1990
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 903846
16 July 1990
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 905659
13 July 1990
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1213435
29 June 1990
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 917694
28 May 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 906182
30 January 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1213820
4 January 1990
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1215504
20 October 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 886902
21 July 1989
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1340892
20 April 1989
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1045224
19 April 1989
Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1348878
14 March 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 893294
11 October 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 888801
19 July 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1030724
14 March 1988
COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1337844
1 December 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1001611
26 October 1987
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1024675
23 March 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1330164
8 May 1986
Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 996120
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2026
Resolved
Non-conducting mats or grating shall be provided on deck in front and rear of switchboards. Electrical mats missing on 03 switchboards, install non-conducting mats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2026
Resolved 19 May 2026
Resolution: Inspector received photograph of non-conducting mats in front of/rear of switchboards.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2026
Resolved
Equipment mounted on a hinged door of an enclosure shall be constructed or shielded in such a manner that no live parts of the door mounted equipment will be exposed to accidental contact by a person with the door open and circuit energized. Install switch blank in switchboard to shield energized bus bar.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2026
Resolved 19 May 2026
Resolution: Inspector received photograph of blank installed in switchboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2026
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck as per subpart 177.30-7 of this subchapter. Installed emergency lighting in galley did not work; restore to operational condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2026
Resolved 5 June 2026
Resolution: Inspector verified deficiency was corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2026
Resolved
Nameplates. Each nameplate for a circuit breaker must show the electrical load served and the setting of the circuit breaker. Label breakers in switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2026
Resolved 19 May 2026
Resolution: Inspector received photograph of labelling of breakers in switchboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2024
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MI found several lifebuoys with deteriorating lines. Replace life buoys with new ones in accordance with current regulations and notify local OCMI once completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 18 June 2024
Resolution: Received photos from vessel rep showing 3 new life buoys.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 June 2024
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. MI found galley ventilation was cover in grease. Clean vents and notify local OCMI once completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 18 June 2024
Resolution: Received photo of clean galley ventilation.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 16 August 2023
Resolved
Corroded section of STBD shaft log locatined in aft peak void. Hole penetrating into shaft tube and water leaking into void.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 18 August 2023
Resolution: Temp repairs were made and NDT test was conducted.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 August 2023
Resolved
Temporary repairs via doubler plate was installed on the starboard shaft tube after shaft tube was found holed. Company Port Captain requested to Sector San Diego that the doubler plate remain in-place until 15APR2024, with the following conditions:
-Permanent repairs will be made by means of crop and renew on both port and starboard shaft logs, commencing April 2024.
-Vessel will install a bilge alarm for the compartment that the doubler plate is installed.
-Company will continue morning vessel checks, and notify Sector San Diego of any water ingress into compartment.
Sector San Diego agreed to the request and will coordinate an operational test of the bilge alarm.
Action required: 705 - Other - as specified
Due 15 April 2024
Resolved 5 June 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 June 2023
Resolved
The aft upper deck fire station hose was found deteriorated and leaking, Must replace fire hose to satisfaction of USCG.
Action required: 10 - Deficiency Rectified
Due 7 June 2023
Resolved 7 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2023
Resolved
The port side engine room battery bank was found with the batteries unsupported. Must properly mount the batteries to satisfaction of USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 5 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 June 2023
Resolved
The lazarette and ballast compartments were found to have no operable lighting. Must provide both compartments with adequate lighting to satisfaction of the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 5 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 June 2023
Resolved
The lazarette bilge suction was found without a strainer attached. Must provide required strainer to satisfaction of the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 5 June 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 June 2023
Resolved
Marine Employers shall establish programs for the chemical testing for dangerous drugs on a random basis of vessel crewmembers. Must provide list of all vessel crew members on the random chemical testing program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 5 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 July 2021
Resolved
Grab lines on 02 port side ring buoys found to be deteriorated beyond repair as well as the lanyard connecting the water light. Replace 02 life buoys and replace lanyard for water-light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 July 2021
Resolution: Replaced 02 life buoys and replace lanyard for water-light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2021
Resolved
Electrical wire penetrating bulkhead from engine space to galley missing watertight seal. Install watertight seal where wire penetrates bulkhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 2 July 2021
Resolution: Installed watertight seal where wire penetrates bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2021
Resolved
Wire in engine space from switch board found to be unprotected. Cap wire end.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 2 July 2021
Resolution: Removed wire from circuit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2021
Resolved
Wires located on two VHF radios found to be unprotected. Cap wire ends on both radios.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 7 October 2021
Resolution: Corrected
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 1 July 2021
Resolved
VHF-DSC radios found to be operating without MMSI registration. Register MMSI on VHF-DSC radios.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 7 October 2021
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2020
Resolved
Owners/Operators shall conduct inspections/tests of portable fire extinguishers as required by 46 CFR 115.810. One portable fire extinguisher located in galley space had an outdated inspection tag. Vessel operator must provide sufficient evidence that the extinguisher was inspected to the satisfaction of the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of serviced extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 March 2020
Resolved
Vessels which carry more than 150 passengers shall meet the structural fire protection requirements of 46 CFR 72.05. It was discovered that a section of structural fire protection material located on the overhead in the engine space was missing. Must rectify to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of repaired structural fire protection.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 March 2020
Resolved
Vessels which carry more than 150 passengers shall meet the structural fire protection requirements of 46 CFR 72.05. It was discovered that the electrical conduit penetration from the main deck to the engine space had missing fire stop protection. Must rectify to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of sealed deck penetration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2020
Resolved
Vessels are required to carry ring buoys as specified in 46 CFR 117.70. It was discovered that the grab line on the ring buoy located adjacent to the pilot house was in poor condition. Must rectify to the satisfaction of the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of replaced grab line.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2020
Resolved
All ventilation ducts to accommodation spaces must be in good working condition. It was observed that the galley ventilation duct had excess grease build-up. Must rectify to the satisfaction of the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of cleaned and painted ducting.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 30 March 2020
Resolved
All tank ventilation outlets must be in good material condition. Ventilation pipe to the lube oil tank on the port side was fractured. Operator must condemn use of the tank until ventilation pipe has been replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2020
Resolved 21 May 2020
Resolution: Vessel rep provided photo of repaired vent pipe.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019
Resolved
Renew retro tape on 18 identified life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 6 August 2019
Resolution: Retro tape was placed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Replace welding cables on both battery banks with marine cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 6 August 2019
Resolution: Welding cables were replaced with marine grade cables.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Provide main engines with electrical junction box covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 6 August 2019
Resolution: Junction boxes were provided with covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Replace unauthorized 120 volt cable in pilot house with boat cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 6 August 2019
Resolution: Cable was replaced with boat cable.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 September 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 November 2018
Resolution: Verified in VIVS
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 13 June 2017
Resolved
Provide screen for fuel vents.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 12 July 2017
Resolution: 30 by 30 mesh flame screen installed.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 13 June 2017
Resolved
Provide non combustible trash cans throghout vessel.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 16 August 2017
Resolution: No combustable cans purchased.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 June 2017
Resolved
Provide retro tape.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 12 July 2017
Resolution: New life ring purchased, retroreflective tape now in compliance with CFR.
Construction/Loadline › Hull › Hull Plating
Issued 26 April 2016
Resolved
Provide plans and drawings to OCMI for repairs/alterations being conducted on vessel. Plans must include reasons for work, scope of work, condition prior to repair, and plans for repairs including materials to be used. Cease all repair work being conducted on vessel until plans are approved by OCMI
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2016
Resolved 12 May 2016
Resolution: Final hull repairs witnessed by attending MI; all sat.
Fire Fighting › Combustible Materials › Linings
Issued 2 October 2014
Resolved
01) Properly remove fire hazard/combustible material under Port and Stbd generators.
Due 2 November 2014
Resolved 21 November 2014
Resolution: Material properly removed under Port and Stbd generator.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 2 October 2014
Resolved
02) Provide marine grade battery cables on Port side battery to starter.
Due 2 November 2014
Resolved 21 November 2014
Resolution: Cables provided for Port side battery starter.
Engineering › Steering Gear System › Ram
Issued 11 June 2012
Resolved
Service & demonstrate proper operation of both steering hydraulic rams
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 30 July 2012
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 11 June 2012
Resolved
Label upper deck for 200 person maximum capacity IAW vessel stability letter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 30 July 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 11 January 2010
Resolved
Demonstrate proper operation of MDEs prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 13 February 2010
Resolution: Demonstrated proper operation of MDEs.
Construction/Loadline › Structures › Manhole
Issued 6 April 2009
Resolved
Replace ladder in lazerette
Action required: 705 - Other - as specified
Resolved 6 May 2009
Resolution: Ladder was renewed
Engineering › Bilge Water Management System › Strainer
Issued 6 April 2009
Resolved
Clean the entire galley bilge
Action required: 705 - Other - as specified
Resolved 2 July 2018
Resolution: Bilge was cleaned
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 April 2009
Resolved
Replace rails and deck area by A/C compressor on upper deck portside aft.
Action required: 705 - Other - as specified
Resolved 6 May 2009
Resolution: Rails and deck were replaced
Stability › Watertight Integrity › General
Issued 6 April 2009
Resolved
Replace main deck starboard side window glass and also upper deck portside window glass
Action required: 705 - Other - as specified
Resolved 6 May 2009
Resolution: Windows were renewed
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 May 2008
Resolved
Repair replace high water bilge alarms visual display light for E/R and Laz.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 23 May 2008
Documentation › Certificates/Documents › Stability Letter
Issued 13 May 2008
Resolved
Post Stability Letter on bridge.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 23 May 2008
Fire Fighting › Grease Extraction Hood › General
Issued 13 May 2008
Resolved
Clean galley hood ducting ventilation (both sides).
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 23 May 2008
Engineering › Generator (propulsion-electric) › Wiring
Issued 13 May 2008
Resolved
Repair water leak from port generator.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 23 May 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 13 May 2008
Resolved
Repair leak in stbd MDE jacket water cooling line.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 23 May 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 June 2007
Resolved
Provide currently corrected CG Light List for areas vessel transits (excerpts are acceptable).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 4 September 2007
Resolution: Operator provided updates to 2006 Light List; 2007 Light List not published yet.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 June 2007
Resolved
Re-label breaker panel in engine space. Currently unreadable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 4 September 2007
Engineering › Freshwater Generation System › Piping
Issued 25 April 2007
Resolved
Repair leaking water pipe in stbd side lazarette (2 void spaces fwd from hatch) above the permanent ballast.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 10 May 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 21 June 2006
Resolved
Repair light fixture in engine room on port side of port engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2006
Resolved 31 July 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 21 June 2006
Resolved
Use or remove dead-end cables in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2006
Resolved 31 July 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 21 June 2006
Resolved
Re-support wire & cables in metallic supports where loosened in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2006
Resolved 31 July 2006
Stability › Severe Wind/Roll › General
Issued 21 June 2006
Resolved
Secure new refridgerator/table units in galley form free movement underway IAW 46 CFR 46CFR176.830.
Action required: 705 - Other - as specified
Due 31 August 2006
Resolved 6 September 2006
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 5 April 2006
Resolved
Mark draft marks.
Due 5 April 2006
Resolved 21 June 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 5 April 2006
Resolved
Install exhaust lagging where missing, starboard generator.
Due 5 April 2006
Resolved 20 April 2006
Construction/Loadline › Hull › Bottom Plating
Issued 5 April 2006
Resolved
Clean and prep for CG inspection, rust blisters in lazarette and exhaust outlets.
Due 5 April 2006
Resolved 20 April 2006
Construction/Loadline › Hull › Bottom Plating
Issued 5 April 2006
Resolved
Clean and make available for CG inspection below galley deck plates.
Due 5 April 2006
Resolved 19 April 2006
Operations/Management › Drills/Instruction › Safety Orientation
Issued 4 April 2005
Resolved
Provide and post emergency check off list.
Action required: 705 - Other - as specified
Due 11 May 2005
Resolved 10 May 2005
Resolution: Procured and posted emergency check off list.
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 4 April 2005
Resolved
Provide valid first aid and CPR documentation for 50% of the crew.
Action required: 705 - Other - as specified
Due 11 May 2005
Resolved 10 May 2005
Resolution: Provided documentation for all personnel onboard having first aid training.
Documentation › Logs/Records › Drug Test Records
Issued 5 May 2004
Resolved
Provide copy of annual report of drug testing submitted to HQ.
Due 21 May 2004
Resolved 5 May 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 5 May 2004
Resolved
Replace guard on light in storage closet next to heads amidships.
Due 21 May 2004
Resolved 5 May 2004
Electrical › Electric Supply System (service) › Transformer
Issued 5 May 2004
Resolved
Renew latch on centerline electrical panel door.
Due 21 May 2004
Resolved 5 May 2004
Engineering › Compressed Air System (start air) › Compressor
Issued 5 May 2004
Resolved
Properly mount and wire air compressor on stbd side in engine room.
Due 21 May 2004
Resolved 5 May 2004
Engineering › Bilge Water Management System
Issued 16 April 2003
Resolved
Install suitable strainer on bilge suction line in engineroom IAW 46 CFR 182.510(b). LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 5 June 2003
Stability
Issued 16 April 2003
Resolved
Suitably mark the maximum allowable passengers at entry to all upper decks IAW 46 CFR 185.602(g) and vessel's stability letter.
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 5 June 2003
Fire Fighting › Fire Pumps
Issued 3 July 2002
Resolved
Renew seal on fire pump LEGACY COMPONENT DESC: Gland Sealing
Condition: Placed in Improper Service
Due 3 August 2002
Resolved 8 August 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002
Resolved
Make front of fire pump control box deadfront LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 8 August 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002
Resolved
Install cover over HW heater connections to element. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 3 July 2002
Electrical › Lighting (service)
Issued 3 July 2002
Resolved
place bulb guards on all exposed light bulbs. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 8 August 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002
Resolved
Cover blank space in galley power panel. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 8 August 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002
Resolved
Install door handle on panel #8. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 8 August 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002
Resolved
permanently label breakers in PH panel. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 8 August 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002
Resolved
Insrall box cover on RAI JCT box LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 3 July 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002
Resolved
Seal cable through pipe to steeering CMPT from ER. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 8 August 2002
Construction/Loadline › Penetrations
Issued 3 July 2002
Resolved
attach valve handle to FW washdown piping.
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 8 August 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 3 July 2002
Resolved
Install proper mesh on vent pipe. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 3 August 2002
Resolved 3 July 2002
Accommodation/Occupational Safety › Potable Water System
Issued 3 July 2002
Resolved
Strap HW heater in galley to the bulkhead.
Condition: Improper Installation
Due 3 August 2002
Resolved 3 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2002
Resolved
Replace broken window on main deck, forward starb. bow. LEGACY COMPONENT DESC: Window
Condition: Damaged By Earlier Event
Due 1 February 2002
Resolved 2 July 2018
Resolution: Window replaced and witnessed by inspector
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 26 December 2001
Resolved
Replace broken window on starb. bow. LEGACY COMPONENT DESC: Open Deck Space
Condition: Damaged By Earlier Event
Due 2 January 2002
Resolved 28 December 2001
Electrical
Issued 28 April 2001
Resolved
Demonstrate proper operation of both SSDGs electrical power distribution systems. Provide supporting documentation or conduct electrical die- electrical tests on effected equipment (bilge pump, alarms, and electrical power buss).
Condition: Unknown
Due 5 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 28 April 2001
Resolved
Crop and renew all areas of hull plating wasted more than 80% of original thickness (3/8 inch). Submit repair proposal to [name withheld] for review and approval prior to repairs.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Construction/Loadline
Issued 28 April 2001
Resolved
Crop and renew section of hulling plating that was clad welded. This shallbe completed prior to next scheduled dry-docking.
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Construction/Loadline
Issued 28 April 2001
Resolved
Contact [name withheld] and make engine room bilge ready for special examination every three months. Dates of inspections shall be on or near 01AUG01, 01NOV01 and 01FEB02.
Condition: Unknown
Due 1 February 2002
Resolved 5 July 2002
Electrical
Issued 28 April 2001
Resolved
Make repairs to STBD generator, demonstrate proper operation to attending inspector. Vessel limited to San Diego Bay until item is cleared.
Condition: Unknown
Due 11 May 2001
Resolved 11 May 2001
Construction/Loadline
Issued 28 April 2001
Resolved
Submit gauging report of vessels hull as indicated by CG inspector. Area to include fwd engine room center line, aft apx 10 feet, two feet up on both port and stbd side.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Engineering
Issued 26 April 2001
Resolved
Identify cause of port diesel engine failure, make repairs, and prove proper opertion prior to carrying passengers.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Engineering
Issued 2 November 1999
Resolved
MAKE PERMENANT REPAIRS (SHAFT REPLACEMENT) BY 12 DECEMBER 1999 TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 November 1999
Resolved 2 November 1999
Navigation
Issued 30 March 1998
Resolved
REMOVE COVER SHIELD FROM NAV RUNNING LIGHTING SO SIDE SCREENS WILL SHOW._x001C_
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 30 March 1998
Resolved
REPAIR EMERGENCY LIGHTING. _x001C_
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Fire Fighting
Issued 30 March 1998
Resolved
INSTALL MISSING NOZZLE CONE ON FIRE STA #3._x001C_
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 30 March 1998
Resolved
INSTALL MISSING JUNCTION BOX COVER #5 IN GALLEY.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Accommodation/Occupational Safety
Issued 30 March 1998
Resolved
CLEAN GALLEY OVEN VENT._x001C_
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 30 March 1998
Resolved
INSTALL ELECTRICAL PANEL PROPERLY IN E/R._x001C_
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 30 March 1998
Resolved
INSTALL MISSING LIGHT COVERS IN FWD BOS'N LOCKER, GALLEY, ENGINE ROOM (OPENWIRE), AFT STEERING COMPARTMENT..._x001C_
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Documentation
Issued 30 March 1998
Resolved
EXPIRED CERTIFICATE OF DOCUMENTATION._x001C_
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 30 March 1998
Resolved
PROVIDE MISSING (6) ORANGE FLARES._x001C_
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 3 April 1997
Resolved
PROVIDE AND DISPLAY LIFE JACKET PLACARD ON ALL DECKS WHERE LIFE JACKETS ARESTORED.
Condition: Unknown
Due 18 April 1997
Resolved 2 May 1997
Navigation
Issued 3 April 1997
Resolved
PROVIDE AND PROPERLY DISPLAY EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 18 April 1997
Resolved 2 May 1997
Unknown
Issued 3 April 1997
Resolved
PROVIDE AND DISPLAY A PROPER STATION BILL.
Condition: Unknown
Due 18 April 1997
Resolved 2 May 1997
Lifesaving
Issued 3 April 1997
Resolved
PROVIDE AND INSTALL 406 MHz EPIRB PRIOR TO OPERATING ON LIMITED COASTWISE ROUTE.
Condition: Unknown
Due 6 June 1997
Resolved 2 May 1997
Electrical
Issued 10 July 1996
Resolved
REPLACE MISSING-HOLED LIGHT COVERS IN WAY OF ENGINE ROOM AND GALLEY.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Fire Fighting
Issued 10 July 1996
Resolved
REPLACE TYPE B-I PORTABLE FIRE EXTINGUISHER WITH TYPE B-II PORTABLE FIRE EXTINGUISHER IN WAY OF SECOND DECK FORWARD STARBOARD SIDE.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Navigation
Issued 10 July 1996
Resolved
MOVE STERN LIGHT OUT OF OBSTRUCTION OF THE FLAG POLE.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Lifesaving
Issued 10 July 1996
Resolved
PROVIDE ONE LIFE RING BUOY WITH LINE TO REPLACE ONE LIFE RING BUOY WITH DETERIORATED GRAB LINE.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Accommodation/Occupational Safety
Issued 10 July 1996
Resolved
PROPERLY MARK EMERGENCY ESCAPE HATCH WITH "KEEP CLEAR, EMERGENCY ESCAPE", FOR ENGINE ROOM AND GALLEY EMERGENCY ESCAPE HATCH IN WAY OF MIDBODY MAIN DECK.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Lifesaving
Issued 10 July 1996
Resolved
REAPIR RAILINGS IN WAY OF LIFEFLOATS STOWAGE.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Documentation
Issued 10 July 1996
Resolved
PROVIDE CURRENT 46 CFR SUBCHAP "T".
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Construction/Loadline
Issued 26 May 1994
Resolved
REMOVE ALL OIL FROM BILGES IN THE ENGINEROOM.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Electrical
Issued 26 May 1994
Resolved
INSTALL METAL CABLE SUPPORTS FOR THE WIRING RUNS IN THE GALLEY.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Electrical
Issued 26 May 1994
Resolved
PROVIDE BLANKS FOR THE OPEN CIRCUIT BREAKER SPACES ON THE DISTRIBUTION PANELS IN THE ENGINEROOM (#3) AND THE GALLEY (#7).
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Electrical
Issued 26 May 1994
Resolved
RENEW OR REPLACE THE COVERS FOR THE LIGHT FIXTURES IN THE ENGINEROOM.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Electrical
Issued 26 May 1994
Resolved
PROVIDE A COVER FOR THE AFTERMOST FLOURESCENT LIGHT IN THE GALLEY.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Electrical
Issued 26 May 1994
Resolved
PROVIDE A COVER FOR THE LIGHT FIXTURES IN THE MEN'S HEAD AND IN THE PUMP ROOM.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Engineering
Issued 26 May 1994
Resolved
INSTALL THE HANDGUARD FOR THE PULLEYS AND BELTS IN THE ENGINEROOM, STARBOARD MAIN DIESEL ENGINE, FIRE PUMP DRIVE.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Lifesaving
Issued 26 May 1994
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE A BOATHOOK TO ASSIST IN RECOVERY OF APERSON FROM THE WATER.
Condition: Unknown
Due 26 May 1994
Resolved 15 June 1994
Fire Fighting
Issued 23 July 1993
Resolved
HORIZONTAL FIRE DOORS BETWEEN GALLEY AND MAIN DECK SALON TO COMPLY WITH _x001C_ 46 CFR 72.05-20(c), 72.05-25(b)(9), AND 111.99.
Condition: Unknown
Due 23 July 1993
Resolved 23 July 1993
Engineering
Issued 13 November 1992
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF PORT MAIN ENGINE THROTTLE/TRANSMISSION LINKAGE.
Condition: Unknown
Due 13 November 1992
Resolved 16 November 1992
Accommodation/Occupational Safety
Issued 12 July 1991
Resolved
PROVIDE SUITABLE MEANS OF OPENING THE EMERGENCY ESCAPE SCUTTLES FROM THE ENGINEROOM AND GALLEY. ESCAPE SCUTTLES MUST ALSO BE WATERTIGHT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Fire Fighting
Issued 12 July 1991
Resolved
PROPERLY HOOK UP AND TEST THE REMOTE VENTILATION SHUTDOWN SWITCH FOR THE ENGINEROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Electrical
Issued 13 July 1990
Resolved
CONDUCT A SATISFACTORY TESTING OF THE SHORE TIE POWER SYSTEM.
Condition: Unknown
Due 13 July 1990
Resolved 13 July 1990
Electrical
Issued 13 July 1990
Resolved
PROVIDE AUTOMATICALLY ACTUATED SWITCH FOR THE EMERGENCY LIGHTS UPON FAILUREOF THE MAIN LIGHTING SYSTEM.
Condition: Unknown
Due 13 July 1990
Resolved 13 July 1990
Accommodation/Occupational Safety
Issued 28 May 1990
Resolved
UNAPPROVED CEILING TILES TO BE REMOVED OR REPLACED WITH APPROVED INCOMBUSTIBLE MATERIALS
Condition: Unknown
Due 28 May 1990
Resolved 28 May 1990
Accommodation/Occupational Safety
Issued 28 May 1990
Resolved
DEMONSTRATE THAT CARPETING COMPLIES WITH 46 CFR 72.05-10(O) OR REPLACE WITH APPROVED MATERIAL.
Condition: Unknown
Due 28 May 1990
Resolved 28 May 1990
Lifesaving
Issued 28 May 1990
Resolved
PROVIDE A SUITABLE RESCUE BOAT OR DEMONSTRATE THE ADEQUACY OF THE VESSEL TO SERVE AS A RESCUE PLATFORM.
Condition: Unknown
Due 28 May 1990
Resolved 28 May 1990
Fire Fighting
Issued 28 May 1990
Resolved
HORIZONTAL FIRE DOORS BETWEEN GALLEY AND MAIN DECK SALON TO COMPLY WITH 46 CFR 72.05-25(A)(1)-OPERATION BY ONE PERSON FROM EITHER SIDE; (B)(9)(II)- CONTROL STATION RELEASE AND HOLD BACK HOOKS (RAILINGS, IN THIS CASE).
Condition: Unknown
Due 28 May 1990
Resolved 28 May 1990
Unknown
Issued 14 March 1989
Resolved
PROVIDE DRAWING OF NEW SANITARY SYSTEM TO COMMANDING OFFICER MSO BOSTON FORPLAN APPROVAL.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Construction/Loadline
Issued 14 March 1988
Resolved
REMOVE CAULKING, GASKET, AND PAINT FROM SEAMS AROUND ALL TONNAGE OPENINGS.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Lifesaving
Issued 14 March 1988
Resolved
PROVIDE ONE ADDITIONAL 20-PERSON BOUYANT APPARATUS.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Electrical
Issued 14 March 1988
Resolved
BLOCK OPENINGS IN FRONT OF GALLEY FREEZER ELECTRICAL PANEL BOARD WITH APPROVED DEVICES OR SPARE CIRCUIT BREAKERS.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Accommodation/Occupational Safety
Issued 14 March 1988
Resolved
PROVIDE WRITTEN CERTIFICATION FROM MANUFACTURER OF TYPE OF LIQUID CONTAINED IN FOOD WARMER CANS.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Documentation
Issued 14 March 1988
Resolved
POST EMERGENCY CHECK-OFF LISTS IN SPACES ACCESSIBLE TO PASSENGERS AND CREW.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Accommodation/Occupational Safety
Issued 14 March 1988
Resolved
DEMONSTRATE PROPER OPERATION OF ALL TOILETS FOR PASSENGER USE.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Documentation
Issued 14 March 1988
Resolved
PROVIDE VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Electrical
Issued 14 March 1988
Resolved
PROVIDE SUFFICIENT VENTILATION IN STEERING SPACE AFT TO CREATE A DRY ATMOSPHERE FREE FROM CONDENSATION IN VICINITY OF HIGH VOLTAGE TRANSFORMER.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988