ROGER REVELLE

ROGER REVELLE is a 1996 research vessel. The Coast Guard has recorded 87 inspections since 1996, most recently in July 2026, along with 65 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 1996 to 2026. Most recent: inspection, 27 July 2026.

Built
1996
Last inspected
27 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9075228 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
434249
Flag
UNITED STATES
—
Maury page id
psix-434249

Inspections, by type

…with no type recorded11
…past their stated due date1
Years with a record 25 calendar years (1996–2026)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2247 - Regulatory (Subpart C or D), Net Ton
954 - Convention (Subpart B), Net Ton
1331 - Dead Weight, Ton
3512 - Displacement, Ton
3304 - Regulatory (Subpart C or D), Gross Ton
3180 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 87

27 July 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8447912
27 May 2026 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8383787
14 March 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8325969
6 June 2025 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8156393
22 May 2025 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8141268
7 May 2025 COI Inspection · MARPOL Annex VI Survey · MARPOL Annex IV Survey · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8128935
12 February 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8108256
12 December 2024 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8069097
7 August 2024 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7976311
5 July 2024 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7949635
14 June 2024 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7953519
12 June 2024 Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7933585
14 May 2024 In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7908733
3 May 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7906062
29 November 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7831342
18 October 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7810839
21 September 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7795713
20 September 2023 Type not recorded
No type recorded · Activities Europe · Activity 7795721
12 September 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7790450
24 April 2023 Annual Inspection
Physical examination · Activities Europe · Activity 7674437
31 March 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7661872
7 October 2022 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7575834
15 September 2022 Appeal · Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7559545
8 September 2022 Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7543394
2 September 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7549585
23 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7541541
13 August 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7536673
18 July 2022 MTSA/ISPS Verification · Periodic Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7510843
14 April 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7849372
23 March 2022 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7438231
13 December 2021 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7375199
10 November 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7353850
3 June 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7214287
2 May 2019 Inclining Experiment · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6766192
26 March 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6785357
15 January 2018 DAPI Audit · Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6343828
16 May 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6147877
28 April 2016 COI Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5844908
6 April 2016 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 5848173
27 October 2015 Hull Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5751563
29 November 2010 Drydock Exam · Internal Structural Exam
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 3906506
20 November 2008 Administrative Inspection
Administrative · Activities Europe · Activity 3366510
5 November 2008 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3357645
26 June 2008 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3248420
8 November 2007 Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 3104209
20 March 2007 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3194724
11 October 2006 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2798477
22 September 2006 Inclining Experiment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2781560
2 June 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2668252
3 May 2006 MTSA Verification · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2639966
20 April 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2629680
15 February 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2585667
26 January 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2573881
3 November 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2510135
2 August 2005 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2449136
21 June 2004 MTSA/ISPS Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2080275
19 May 2004 Periodic Inspection · MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2035540
24 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1982882
10 July 2003 MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1821566
19 June 2003 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1821811
29 May 2003 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1804882
19 May 2003 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1797070
30 April 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1783493
20 February 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1746523
11 December 2002 Inclining Experiment
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1718015
10 June 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1628847
29 May 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1623012
16 January 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1479290
3 October 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1433884
11 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 18980
11 June 2001 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1423586
7 February 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379268
29 June 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1376248
1 December 1999 Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1361256
1 September 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 782220
12 August 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 777546
10 August 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1375866
3 December 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 805495
30 October 1998 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 804042
2 June 1998 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1127645
11 August 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1120782
28 July 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1383649
24 July 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1368390
17 April 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1102644
3 October 1996 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 836061
25 June 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1040458
11 June 1996 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1184904

Deficiency record · 65

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2025 Resolved
A vessel's hull must not carry current as a conductor except for the following ...A voltage to hull potential ground was found in the bow thruster room lighting circuit. This was indicated in the installed ground detection system. Circuit has LO-TO procedures in place IAW the SMS. Provide proper installation to attending USCG MI prior to placing back in to service. 46CFR 111.05-11.a.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 21 May 2025
Resolution: System was corrected and placed in service
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 May 2025 Resolved
Watertight doors shall be designed, constructed, tested, and marked in accordance with ASTM F 1196. The class III WTD's have no audible indication of remote (Bridge) closure. Provide IAW the ASTM F1196 standard to the satisfaction of the attending USCG MI. 46CFR 170.270.c.1.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 22 May 2025
Resolution: New aduible alarm installed and operationally tested.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 7 May 2025 Resolved
Non-conducting deck coverings, such as non-conducting mats or gratings, suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard ...The main switchboard is missing rear matting. Provide matting to the satisfaction of the attending USCG MI. 46CFR 111.30-11
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 21 May 2025
Resolution: Matting installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 May 2025 Resolved
Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel. The vessel could only produce the approval of testing from MSC. Provide OCMI level approval letter that the tests have been satisfactorily witnessed IAW the MSC letter. 46CFR 61.40-1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 7 June 2025
Resolved 9 July 2025
Resolution: Revised 835v
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 May 2025 Resolved
The respective piping systems installed on ships ...for safe and efficient operation of the vessel. A pinhole fracture was found in the copper nickel overboard discharge pipe for generator salt water cooling (IVO overhead OWS). Effect repairs to the satisfaction of the attending USCG MI. 46CFR 56.01-2.b.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 21 May 2025
Resolution: Piping replaced by Detyens Shipyard
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 May 2025 Resolved
At the bottom of the fact sheet of the maneuvering data, the following statement must appear: WARNING The response of ...This is missing from the posted maneuvering placard on the pilothouse. Provide IAW with regulation to the attending USCG MI. 46CFR 196.19-1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 21 May 2025
Resolution: Statement added
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 7 May 2025 Resolved
The Oil Record Book, whether as part of the ship's official logbook or otherwise, shall be completed on each occasion as indicated in Annex I of MARPOL. The vessel had substantial increases in values to the Waste Oil Tank that were improperly documented. The increases were only noted by the weekly soundings. Crew educated for a correction on the spot. MARPOL Annex I Reg. 17
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 7 May 2025
Resolved 7 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 May 2025 Resolved
The integrity of any deck in way of a stairway, shall be maintained by means of “A” or “B” class ...There were three marine cable transitions in way of stair towers missing or having inadequate "fire-stop" material to maintain boundary. Corrected on the spot. 46CFR 190.07-10
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 7 May 2025
Resolved 7 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 May 2025 No resolution recorded
Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel. The vessel could only produce the approval of testing from MSC. Provide OCMI level approval letter that the tests have been satisfactorily witnessed IAW the MSC letter. This item is due prior to departure from next US port of call. Local shifting is authorized within the OCMI zone. 46CFR 61.40-1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 19 March 2025 Resolved
Noted the following areas in the plenum, needing to be cropped/renewed: 1. The aft bulkhead, inboard side, had an area approximately 18"x10" that was substantially corroded, crop and renew. 2. Aft bulk head, middle of the bulkhead, approximately a 18"x18" minimum insert due to a hole through the bulkhead. 2. Inboard bulkhead, aft section, 12"x 12" minimum insert due to hole through the bulkhead. 3. Forward bulkhead, middle of the bulkhead, below the main deck, minimum of a 12"x12" insert due to a hole through the bulkhead. 705c Prior to dry dock credit.
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: All areas identified for repair were renewed, conducted NDT - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2024 Resolved
Power-driven pump or pumps connected to the bilge main as required by table 56.50-55(a). The bilge pump was inoperable. 46 CFR 56.50-55(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2024
Resolved 17 May 2024
Resolution: Pump motor was replaced. Operational test SAT.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 17 May 2024 Resolved
Machinery space bilges,bilge wells, shaft alley bilges, and other minimally attended locations where liquids might accumulate must be monitored for the ECC to detect flooding angles from vertical of up to 15 degrees heel and trim. MI observed the bilge alarm for the Bow Thruster Room was inoperable in the ECR. 46 CFR 188.20-1 46 CFR 62.50-20 (e)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2024
Resolved 17 May 2024
Resolution: Sensor was replaced. Operational test SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 17 May 2024 Resolved
All ducts shall be of steel construction and reasonably gastight from end to end. MI observed an exhaust leak in the incinerator upper duct. 46 CFR 188.20-1 46 CFR 190.15-5 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 17 May 2024
Resolution: Gasket was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 May 2024 Resolved
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm setpoints, the procedure to be followed, and the expected test result. Vessel did not have step-by-step procedure to test emergency generator alarms. Vessel shall submit procedure to MSC for approval. 46 CFR 61.40-10 (a)
Action required: 705 - Other - as specified
Due 1 June 2024
Resolved 13 December 2024
Resolution: PSTP was witnessed by MI and approved by MSC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 November 2023 Resolved
Vessel is operating on one of two power inverters, causing a reduction in power to the port propulsion unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2023
Resolved 21 December 2023
Resolution: Rcvd ABS attendance Report, and technician report attesting to the replacement of parts, and full restoration of the engineering plant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2023 Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service intended. Received report of failed seal on port Z-Drive. Effect repairs at drydock. Provide Class Report once repaired.
Action required: 705 - Other - as specified
Resolved 27 November 2023
Resolution: received class report with satisfaction of repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 22 May 2023 Resolved
OCMI will determine the specific manning levels for vessels required to have certificates of inspection by Part B of Subtitle II of Title 46 U.S.C. The masters or individuals in command of all vessels, whether required to be inspected under 46 U.S.C. 3301 or not, are responsible for properly manning vessels in accordance with the applicable laws, regulations, and international conventions. Vessel is sailing short 2nd Engineer; return to full crew compliment per COI minimum manning requirements.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2023
Resolved 26 May 2023
Resolution: New C/E reported
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 22 May 2023 Resolved
The Oil Record Book Part I shall be kept in such a place as to be readily available for inspection at all reasonable times and... shall be kept on board... for a period of three years after the last entry has been made. Vessel Oil Record Book Part I from April 2019 to May 2022 could not be found on board. Vessel and shoreside personnel believe book was archived at home port. Return oil record book to ship. MARPOL 73/78 (2021 Ed) Annex I/17.6
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 24 May 2023
Resolution: Record Book was located in San Diego and overnighted to the vessel.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 22 May 2023 Resolved
Each operation required in the Oil Record Book Part I shall be fully recorded without delay, so that all entries in the book appropriate to that operation are completed. Each completed operation shall be signed by the officer or officers in charge of the operations concerned. Vessel Oil Record Book Part I from May 2022 to present was found with inaccurate code entries and signed by the deck officers, not the engineering officer in charge of the operation concerned. Correct all inaccurate code entries in red ink and have master sign each page after review in red ink.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2023
Resolved 16 June 2023
Resolution: ORB code entries corrected in red ink by vessel master. Training provided.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 22 May 2023 Resolved
Entries in the Garbage Record Book shall be made when garbage is discharged to a reception facility ashore. Garbage entry was missing for 2.0m3 discharge in Australia on 09 March 2023. Correct Garbage Record Book to reflect missed entry - post dated correction okay.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 June 2023
Resolved 17 May 2024
Resolution: Garbage Record Book- All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 May 2023 Resolved
Propulsion machinery orders from the navigation bridge shall be indicated in the main machinery control room or at the maneuvering platform as appropriate. Propulsion orders relating to EOT/RPM equivalents are not posted on bridge, ECR and propulsion control room. Post at each location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2023
Resolved 27 May 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 22 May 2023 Resolved
Complete internal SMS audit within next 90 days for STCW and Record Management deficiencies noted above.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 17 May 2024
Resolution: Audit completed on 30JUNE2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 April 2023 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Wiring to permanently installed start air receivers’ automatic blow downs are not properly installed. Properly install power cables into junction boxes.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 24 May 2023
Resolution: Hard wired cable into j-box
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 August 2022 Resolved
The statutes relating to inspection of public vessels are primarily contained in 46 U.S.C. 2101(24) and 2109. a. 46 U.S.C. 2101(24) defines a public vessel as one that "is owned, or demise chartered, and operated by the United States Government or a government of a foreign country; and…is not engaged in commercial service." The ROGER REVELLE is owned by the United States Navy (Office of Naval Research), operated by SCRIPPS INSTITUTE, and is not engaged in commercial service. U.S. Navy and National Oceanic and Atmospheric Administration (NOAA) vessels as defined in 46 U.S.C. 2101(24) operated for oceanographic research are not required to be inspected and certificated by the Coast Guard. However, such vessels may be inspected and certificated upon request by the parent agency and upon an “interagency agreement to this effect.” Without an interagency agreement, the Coast Guard does not have authority or jurisdiction to conduct inspections, or casualty investigations on the ROGER REVELLE. You are required to "initiate" an interagency agreement between the Office of Naval Research (ONR) and the United States Coast Guard no later than December 22, 2022. Failure to establish an interagency agreement with the Coast Guard will result in the Coast Guard withdrawing the vessel’s Certificate of Inspection (COI). It is our understanding that the Office of Naval Research owns several research vessels that are operating in a similar manner. It would be beneficial to enter all ONR research vessels under the same interagency agreement. If you disagree with this decision you may ask for reconsideration, or appeal this decision in accordance with 46 CFR 1.03-20.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 December 2022
Resolved 31 March 2023
Resolution: CG-CVC has determined that they will not require ONR to enter into an interagency agreement or MOA/MOU with CG. Policy guidance is under development by CG-CVC regarding inspection of vessels under the University-National Oceanographic Laboratory System.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 23 August 2022 Resolved
ISM CODE 1.2 Objectives 1.2.3 The safety management system should ensure: 1.2.3.2 that applicable codes, guidelines and standards recommended by the Organization, Administrations, classification societies and maritime industry organizations are taken into account. Evidence: During a recent Coast Guard administrative inspection, it was discovered that the ROGER REVELLE has been sailing into and out of pilotage ports without being under the direction and control of an individual qualified to serve as pilot. In accordance with 46 CFR 15.812, when the ROGER REVELLE is underway on federal pilotage waters of the united states, the vessel must be under the direction and control of an individual qualified to serve as pilot. Conducted a review of pilot procedures in the vessel SMS. The SMS contains two pilot procedures; One for embarking a pilot and the other on interactions with the pilot [name withheld] does not contain procedures or guidance on on when a pilot is required. You are required to initiate corrective action plan in accordance with your SMS. Final corrective action is to be to the satisfaction of the Recognized Organization (ABS).
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 September 2022
Resolved 7 October 2022
Resolution: Corrective Action accepted by ABS (the RO)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 July 2022 Resolved
Vessel's ANSUL Fixed Fire Fighting System, which protects a range hood and deep fat fryer in the galley, has failed service testing. Repair/replace the affected ANSUL system so that it passes service testing. The range hood and deep fat fryer associated with the affected ANSUL system must be tagged out and may not be used until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 21 July 2022
Resolution: Recevied documentation of completed repairs and satisfactory functional test.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 18 July 2022 Resolved
OWS functional test failure due to faulty PWS feed pump. Repair/replace PWS feed pump, and conduct a satisfactory test of the OWS in presence of USCG marine inspectors. This deficiency must be rectified by 30SEP2022.
Action required: 705 - Other - as specified
Resolved 21 July 2022
Resolution: Witness Operational test SAT, endorsed IOPP certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2022 Resolved
Each device must be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. Identified a temporary patch on 3-4 inch pipe on Marine Sanitation system piping within the engine room lower level forward bulkhead. Provide permanent repair plan proposal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 21 July 2022
Resolution: Replaced 4 inch section of pipe; in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2021 Resolved
Main bilge pump found unable to draw suction from engine room and bow thruster space. Repair or replace.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2021
Resolved 8 June 2021
Resolution: Bilge pumping witnessed by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 June 2021 Resolved
Structural fire protection (SFP) on workshop overhead found removed. Properly replace with appropriate SFP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 8 June 2021
Resolution: SFP reinstalled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 June 2021 Resolved
Vessel lost power when starting propulsion motors. Determine cause and proper rectification with manufacturer input.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 24 August 2021
Resolution: Siemens Techs corrected crossed wiring. MI witnessed proper start ups.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 26 January 2006 Resolved
Upon return to first U.S. port complete renewal of Safety Radio Certificate and provide documentation to the cognizant OCMI.
Action required: 705 - Other - as specified
Resolved 20 April 2006
Resolution: Sighted new radio certs dated 14 APR06
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 August 2005 Resolved
Hydro test all fixed CO2 bottles thate are coming due and perform a full functional test of system.
Due 29 September 2005
Resolved 29 November 2005
Construction/Loadline › Structures › Superstructure
Issued 2 August 2005 Resolved
Make perminate and proper repairs to the Starboard bridge wing. To be completed during the next shipyard period.
Due 29 September 2005
Resolved 29 November 2005
Lifesaving › Rescue Boat
Issued 30 April 2003 Resolved
Rescue Boat Falls were end for ended. Conduct 110% weight test.
Due 1 May 2003
Resolved 1 May 2003
Resolution: Weight test was conducted using cement bags.
Fire Fighting › Structural Fire Protection - General
Issued 30 April 2003 Resolved
Properly pack cable run in emergency generator room and provide certification showing packing meets structural fire protection requirements.
Due 1 June 2003
Resolved 27 May 2003
Resolution: Verified proper packing
Documentation › Safety/Response Plans/Programs
Issued 30 April 2003 Resolved
Provide Fire Control Plan for Coast Guard approval that meets SOLAS requirements and addresses relocation of AFFF hose reels. LEGACY COMPONENT DESC: Fire Control Plans
Due 1 July 2003
Resolved 19 June 2003
Resolution: Reviewed plan and stamped approved.
Documentation › Certificates/Documents
Issued 30 April 2003 Resolved
Provide certification showing weathertight doors meet USCG approval.
Due 1 June 2003
Resolved 27 May 2003
Resolution: Witnessed water pressure test of doors. No leakage noticed, proper seal obtained.
Engineering › Lubricating Oil Storage/Transfer System
Issued 30 April 2003 Resolved
Repair piping leaks in lube oil transfer system servicing propulsion motors. LEGACY COMPONENT DESC: Piping
Due 1 May 2003
Resolved 1 May 2003
Engineering › Steering Gear System
Issued 30 April 2003 Resolved
Repair power failure audible alarm on the bridge.
Due 1 May 2003
Resolved 1 May 2003
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System
Issued 30 April 2003 Resolved
Hydro test all weld attachments on modified piping for AFFF hose reels.
Due 1 May 2003
Resolved 1 May 2003
Engineering
Issued 11 June 2001 Resolved
Repair inoperative OWS, solenoid operated, overboard discharge valve.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Lifesaving
Issued 10 August 1999 Resolved
Replace expired and water damaged items in rescue boat first aid kit.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Fire Fighting
Issued 10 August 1999 Resolved
Ensure all fire safety doors close and latch completely.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Fire Fighting
Issued 10 August 1999 Resolved
Place a legend of symbols on all fire control plans.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 10 August 1999 Resolved
Provide ring buoys of sufficient mass to deploy the port and stbd bridge wing smoke flares and waterlights.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Deck/Cargo
Issued 10 August 1999 Resolved
Prove proper operation of port anchor windlass. - Corrected
Condition: Unknown
Due 10 September 1999
Resolved 10 August 1999
Navigation
Issued 10 August 1999 Resolved
Post emergency steering change-over diagram and instructions at wheelhouse steering station.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 10 August 1999 Resolved
Replace both safety relief valves for pressure vessels 312-1279-1 and_x001C_ 312-1279-2 with devices that are stamped at or below MAWP and prove proper opertaion to attending U.S.C.G. Marine Inspector.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 10 August 1999 Resolved
Renew reflective tape on stbd bridge wing ring buoy.
Condition: Unknown
Due 10 September 1999
Resolved 10 August 1999
Fire Fighting
Issued 10 August 1999 Resolved
Label controls and post operating instruction for scientist flammable locker.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 10 August 1999 Resolved
Post Viking liferaft launching instructions at each liferaft station.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 10 August 1999 Resolved
Label general alarm bells 01 deck, port and stbd side weather decks, and focsle.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Lifesaving
Issued 10 August 1999 Resolved
Renew pilot station ring buoy and install automatic waterlight.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Fire Fighting
Issued 10 August 1999 Resolved
Prove operation of EDG room CO2 alarm.
Condition: Unknown
Due 11 August 1999
Resolved 11 August 1999
Fire Fighting
Issued 10 August 1999 Resolved
Post operating instructions at EDG fixed fire extinguishing station.
Condition: Unknown
Due 11 August 1999
Resolved 11 August 1999
Electrical
Issued 10 August 1999 Resolved
Seal wire penatrations between main fire pump room and space above.
Condition: Unknown
Due 11 August 1999
Resolved 11 August 1999
Electrical
Issued 28 July 1997 Resolved
PROVIDE JUNCTION BOX OR PROPERLY COMPLETE CABLE INSTALLATION IN FORWARD STAIR TOWER ON MAIN DECK
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Electrical
Issued 28 July 1997 Resolved
LABEL SWITCH BOX ON MAIN DECK IN AFT TRUNK AND PROVIDE MATCHING CIRCUIT DESIGNATION.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Fire Fighting
Issued 28 July 1997 Resolved
PROVIDE ACCURATE FIRE CONTROL PLAN.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Fire Fighting
Issued 28 July 1997 Resolved
PROVIDE PLANS AND INSTALL GENERAL ALARM BELL OR LIGHT, DEPENDING ON AMBIANTdb LEVEL IN BOS'N LOCKER FORWARD.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Documentation
Issued 28 July 1997 Resolved
PROVIDE SOLAS TRAINING MANNUAL.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Unknown
Issued 11 June 1996 Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED FIRE CONTROL PLAN
Condition: Unknown
Due 8 July 1996
Resolved 26 June 1996
Unknown
Issued 11 June 1996 Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED SOPEP IAW MARPOL 73/78 REGULATION 26. VESSEL IS RESTRICTED FROM PROCEDDING SEAWARD PAST THREE NAUTICAL MILES UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 8 July 1996
Resolved 26 June 1996
Unknown
Issued 11 June 1996 Resolved
CONDUCT FIRE AND BOAT DRILSS
Condition: Unknown
Due 8 July 1996
Resolved 26 June 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.