Records from 2016 to 2026. Most recent: inspection, 27 July 2026.
Inspection history · 39
27 July 2026
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8447912
27 May 2026
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8383787
14 March 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8325969
6 June 2025
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8156393
22 May 2025
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8141268
7 May 2025
COI Inspection · MARPOL Annex VI Survey · MARPOL Annex IV Survey · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8128935
12 February 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8108256
12 December 2024
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8069097
7 August 2024
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7976311
5 July 2024
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7949635
14 June 2024
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7953519
12 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7933585
14 May 2024
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7908733
3 May 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7906062
29 November 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7831342
18 October 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7810839
21 September 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7795713
20 September 2023
Type not recorded
No type recorded · Activities Europe · Activity 7795721
12 September 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7790450
24 April 2023
Annual Inspection
Physical examination · Activities Europe · Activity 7674437
31 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7661872
7 October 2022
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7575834
15 September 2022
Appeal · Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7559545
8 September 2022
Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7543394
2 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7549585
23 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7541541
13 August 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7536673
18 July 2022
MTSA/ISPS Verification · Periodic Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7510843
14 April 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7849372
23 March 2022
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7438231
13 December 2021
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7375199
10 November 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7353850
3 June 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7214287
2 May 2019
Inclining Experiment · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6766192
26 March 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6785357
15 January 2018
DAPI Audit · Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6343828
16 May 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6147877
28 April 2016
COI Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5844908
6 April 2016
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 5848173
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2025
Resolved
A vessel's hull must not carry current as a conductor except for the following ...A voltage to hull potential ground was found in the bow thruster room lighting circuit. This was indicated in the installed ground detection system. Circuit has LO-TO procedures in place IAW the SMS. Provide proper installation to attending USCG MI prior to placing back in to service.
46CFR 111.05-11.a.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 21 May 2025
Resolution: System was corrected and placed in service
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 May 2025
Resolved
Watertight doors shall be designed, constructed, tested, and marked in accordance with ASTM F 1196. The class III WTD's have no audible indication of remote (Bridge) closure. Provide IAW the ASTM F1196 standard to the satisfaction of the attending USCG MI.
46CFR 170.270.c.1.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 22 May 2025
Resolution: New aduible alarm installed and operationally tested.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 7 May 2025
Resolved
Non-conducting deck coverings, such as non-conducting mats or gratings, suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard ...The main switchboard is missing rear matting. Provide matting to the satisfaction of the attending USCG MI.
46CFR 111.30-11
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 21 May 2025
Resolution: Matting installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 May 2025
Resolved
Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel. The vessel could only produce the approval of testing from MSC. Provide OCMI level approval letter that the tests have been satisfactorily witnessed IAW the MSC letter.
46CFR 61.40-1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 7 June 2025
Resolved 9 July 2025
Resolution: Revised 835v
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 May 2025
Resolved
The respective piping systems installed on ships ...for safe and efficient operation of the vessel. A pinhole fracture was found in the copper nickel overboard discharge pipe for generator salt water cooling (IVO overhead OWS). Effect repairs to the satisfaction of the attending USCG MI.
46CFR 56.01-2.b.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 21 May 2025
Resolution: Piping replaced by Detyens Shipyard
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 May 2025
Resolved
At the bottom of the fact sheet of the maneuvering data, the following statement must appear: WARNING The response of ...This is missing from the posted maneuvering placard on the pilothouse. Provide IAW with regulation to the attending USCG MI.
46CFR 196.19-1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 21 May 2025
Resolution: Statement added
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 7 May 2025
Resolved
The Oil Record Book, whether as part of the ship's official logbook or otherwise, shall be completed on each occasion as indicated in Annex I of MARPOL. The vessel had substantial increases in values to the Waste Oil Tank that were improperly documented. The increases were only noted by the weekly soundings. Crew educated for a correction on the spot.
MARPOL Annex I
Reg. 17
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 7 May 2025
Resolved 7 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 May 2025
Resolved
The integrity of any deck in way of a stairway, shall be maintained by means of “A” or “B” class ...There were three marine cable transitions in way of stair towers missing or having inadequate "fire-stop" material to maintain boundary. Corrected on the spot.
46CFR 190.07-10
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 7 May 2025
Resolved 7 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 May 2025
No resolution recorded
Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel. The vessel could only produce the approval of testing from MSC. Provide OCMI level approval letter that the tests have been satisfactorily witnessed IAW the MSC letter. This item is due prior to departure from next US port of call. Local shifting is authorized within the OCMI zone.
46CFR 61.40-1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 19 March 2025
Resolved
Noted the following areas in the plenum, needing to be cropped/renewed:
1. The aft bulkhead, inboard side, had an area approximately 18"x10" that was substantially corroded, crop and renew.
2. Aft bulk head, middle of the bulkhead, approximately a 18"x18" minimum insert due to a hole through the bulkhead.
2. Inboard bulkhead, aft section, 12"x 12" minimum insert due to hole through the bulkhead.
3. Forward bulkhead, middle of the bulkhead, below the main deck, minimum of a 12"x12" insert due to a hole through the bulkhead.
705c
Prior to dry dock credit.
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: All areas identified for repair were renewed, conducted NDT - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2024
Resolved
Power-driven pump or pumps connected to the bilge main as required by table 56.50-55(a).
The bilge pump was inoperable.
46 CFR 56.50-55(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2024
Resolved 17 May 2024
Resolution: Pump motor was replaced. Operational test SAT.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 17 May 2024
Resolved
Machinery space bilges,bilge wells, shaft alley bilges, and other minimally attended locations where liquids might accumulate must be monitored for the ECC to detect flooding angles from vertical of up to 15 degrees heel and trim.
MI observed the bilge alarm for the Bow Thruster Room was inoperable in the ECR.
46 CFR 188.20-1
46 CFR 62.50-20 (e)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2024
Resolved 17 May 2024
Resolution: Sensor was replaced. Operational test SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 17 May 2024
Resolved
All ducts shall be of steel construction and reasonably gastight from end to end.
MI observed an exhaust leak in the incinerator upper duct.
46 CFR 188.20-1
46 CFR 190.15-5 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 17 May 2024
Resolution: Gasket was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 May 2024
Resolved
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm setpoints, the procedure to be followed, and the expected test result.
Vessel did not have step-by-step procedure to test emergency generator alarms.
Vessel shall submit procedure to MSC for approval.
46 CFR 61.40-10 (a)
Action required: 705 - Other - as specified
Due 1 June 2024
Resolved 13 December 2024
Resolution: PSTP was witnessed by MI and approved by MSC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 November 2023
Resolved
Vessel is operating on one of two power inverters, causing a reduction in power to the port propulsion unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2023
Resolved 21 December 2023
Resolution: Rcvd ABS attendance Report, and technician report attesting to the replacement of parts, and full restoration of the engineering plant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2023
Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service intended. Received report of failed seal on port Z-Drive. Effect repairs at drydock. Provide Class Report once repaired.
Action required: 705 - Other - as specified
Resolved 27 November 2023
Resolution: received class report with satisfaction of repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 22 May 2023
Resolved
OCMI will determine the specific manning levels for vessels required to have certificates of inspection by Part B of Subtitle II of Title 46 U.S.C. The masters or individuals in command of all vessels, whether required to be inspected under 46 U.S.C. 3301 or not, are responsible for properly manning vessels in accordance with the applicable laws, regulations, and international conventions. Vessel is sailing short 2nd Engineer; return to full crew compliment per COI minimum manning requirements.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2023
Resolved 26 May 2023
Resolution: New C/E reported
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 22 May 2023
Resolved
The Oil Record Book Part I shall be kept in such a place as to be readily available for inspection at all reasonable times and... shall be kept on board... for a period of three years after the last entry has been made. Vessel Oil Record Book Part I from April 2019 to May 2022 could not be found on board. Vessel and shoreside personnel believe book was archived at home port. Return oil record book to ship. MARPOL 73/78 (2021 Ed) Annex I/17.6
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 24 May 2023
Resolution: Record Book was located in San Diego and overnighted to the vessel.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 22 May 2023
Resolved
Each operation required in the Oil Record Book Part I shall be fully recorded without delay, so that all entries in the book appropriate to that operation are completed. Each completed operation shall be signed by the officer or officers in charge of the operations concerned. Vessel Oil Record Book Part I from May 2022 to present was found with inaccurate code entries and signed by the deck officers, not the engineering officer in charge of the operation concerned. Correct all inaccurate code entries in red ink and have master sign each page after review in red ink.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2023
Resolved 16 June 2023
Resolution: ORB code entries corrected in red ink by vessel master. Training provided.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 22 May 2023
Resolved
Entries in the Garbage Record Book shall be made when garbage is discharged to a reception facility ashore. Garbage entry was missing for 2.0m3 discharge in Australia on 09 March 2023. Correct Garbage Record Book to reflect missed entry - post dated correction okay.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 June 2023
Resolved 17 May 2024
Resolution: Garbage Record Book- All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 May 2023
Resolved
Propulsion machinery orders from the navigation bridge shall be indicated in the main machinery control room or at the maneuvering platform as appropriate. Propulsion orders relating to EOT/RPM equivalents are not posted on bridge, ECR and propulsion control room. Post at each location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2023
Resolved 27 May 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 22 May 2023
Resolved
Complete internal SMS audit within next 90 days for STCW and Record Management deficiencies noted above.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 17 May 2024
Resolution: Audit completed on 30JUNE2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 April 2023
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Wiring to permanently installed start air receivers’ automatic blow downs are not properly installed. Properly install power cables into junction boxes.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 24 May 2023
Resolution: Hard wired cable into j-box
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 August 2022
Resolved
The statutes relating to inspection of public vessels are primarily contained in 46 U.S.C. 2101(24) and 2109.
a. 46 U.S.C. 2101(24) defines a public vessel as one that "is owned, or demise chartered, and operated by the United States Government or a government of a foreign country; and…is not engaged in commercial service."
The ROGER REVELLE is owned by the United States Navy (Office of Naval Research), operated by SCRIPPS INSTITUTE, and is not engaged in commercial service.
U.S. Navy and National Oceanic and Atmospheric Administration (NOAA) vessels as defined in 46 U.S.C. 2101(24) operated for oceanographic research are not required to be inspected and certificated by the Coast Guard. However, such vessels may be inspected and certificated upon request by the parent agency and upon an “interagency agreement to this effect.”
Without an interagency agreement, the Coast Guard does not have authority or jurisdiction to conduct inspections, or casualty investigations on the ROGER REVELLE.
You are required to "initiate" an interagency agreement between the Office of Naval Research (ONR) and the United States Coast Guard no later than December 22, 2022.
Failure to establish an interagency agreement with the Coast Guard will result in the Coast Guard withdrawing the vessel’s Certificate of Inspection (COI).
It is our understanding that the Office of Naval Research owns several research vessels that are operating in a similar manner. It would be beneficial to enter all ONR research vessels under the same interagency agreement.
If you disagree with this decision you may ask for reconsideration, or appeal this decision in accordance with 46 CFR 1.03-20.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 December 2022
Resolved 31 March 2023
Resolution: CG-CVC has determined that they will not require ONR to enter into an interagency agreement or MOA/MOU with CG. Policy guidance is under development by CG-CVC regarding inspection of vessels under the University-National Oceanographic Laboratory System.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 23 August 2022
Resolved
ISM CODE 1.2 Objectives
1.2.3 The safety management system should ensure:
1.2.3.2 that applicable codes, guidelines and standards recommended by the Organization, Administrations, classification societies and maritime industry organizations are taken into account.
Evidence: During a recent Coast Guard administrative inspection, it was discovered that the ROGER REVELLE has been sailing into and out of pilotage ports without being under the direction and control of an individual qualified to serve as pilot. In accordance with 46 CFR 15.812, when the ROGER REVELLE is underway on federal pilotage waters of the united states, the vessel must be under the direction and control of an individual qualified to serve as pilot.
Conducted a review of pilot procedures in the vessel SMS. The SMS contains two pilot procedures; One for embarking a pilot and the other on interactions with the pilot [name withheld] does not contain procedures or guidance on on when a pilot is required.
You are required to initiate corrective action plan in accordance with your SMS.
Final corrective action is to be to the satisfaction of the Recognized Organization (ABS).
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 September 2022
Resolved 7 October 2022
Resolution: Corrective Action accepted by ABS (the RO)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 July 2022
Resolved
Vessel's ANSUL Fixed Fire Fighting System, which protects a range hood and deep fat fryer in the galley, has failed service testing. Repair/replace the affected ANSUL system so that it passes service testing. The range hood and deep fat fryer associated with the affected ANSUL system must be tagged out and may not be used until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 21 July 2022
Resolution: Recevied documentation of completed repairs and satisfactory functional test.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 18 July 2022
Resolved
OWS functional test failure due to faulty PWS feed pump. Repair/replace PWS feed pump, and conduct a satisfactory test of the OWS in presence of USCG marine inspectors. This deficiency must be rectified by 30SEP2022.
Action required: 705 - Other - as specified
Resolved 21 July 2022
Resolution: Witness Operational test SAT, endorsed IOPP certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2022
Resolved
Each device must be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. Identified a temporary patch on 3-4 inch pipe on Marine Sanitation system piping within the engine room lower level forward bulkhead. Provide permanent repair plan proposal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 21 July 2022
Resolution: Replaced 4 inch section of pipe; in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2021
Resolved
Main bilge pump found unable to draw suction from engine room and bow thruster space. Repair or replace.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2021
Resolved 8 June 2021
Resolution: Bilge pumping witnessed by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 June 2021
Resolved
Structural fire protection (SFP) on workshop overhead found removed. Properly replace with appropriate SFP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 8 June 2021
Resolution: SFP reinstalled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 June 2021
Resolved
Vessel lost power when starting propulsion motors. Determine cause and proper rectification with manufacturer input.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 24 August 2021
Resolution: Siemens Techs corrected crossed wiring. MI witnessed proper start ups.