Records from 1996 to 2021. Most recent: inspection, 5 August 2021.
Documentation record
Registered dimensions (L × B × D)52.0 ft × 27.0 ft × 4.0 ft
Registered tonnagegross 47 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWHITE'S FERRY INC · DICKERSON, MD, UNITED STATES · built 1995
Hull materialSteel
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portDICKERSON, MD
Trade endorsementsRegistry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Net Ton
47 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
5 August 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7277680
7 July 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6999633
1 July 2020
In-Service Inspection · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7133214
1 August 2019
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6769365
27 June 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6459467
25 April 2017
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6132425
2 August 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5974752
7 December 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5776669
4 December 2015
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5778491
24 September 2015
Underwater Inspection in lieu of Drydock
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5747804
29 July 2015
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5200674
13 August 2014
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4955539
12 August 2014
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4952482
27 July 2011
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4096260
21 March 2010
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3701366
20 March 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3700407
28 October 2008
Drydock Extension · Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3356973
19 April 2007
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2919632
19 September 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2781695
18 August 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1901466
1 May 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2639540
25 May 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2365946
4 May 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2114004
4 November 2003
Underwater Inspection in lieu of Drydock
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1942654
30 September 2003
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1917526
2 May 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1789924
19 June 2002
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1635462
30 April 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1610670
16 May 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1384840
3 May 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1397440
6 May 1999
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 808309
23 September 1998
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 803124
21 July 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 796090
24 June 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1364221
10 May 1996
Initial Certification · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1089012
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 December 2015
Resolved
At all times the vessel shall have licensed master and applicable assigned crew as perscribed under routes and conditions of vessel's Certificate of Inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 December 2015
Resolved 23 December 2015
Resolution: Licensed master was observed on board.
Deck/Cargo › Towing › Towline
Issued 23 December 2015
Resolved
Provide maintenance plan to include inspection proceedures for tow cable and all applicable fittings and connections including replacement intervals as applicable.
Condition: Improper/Lack of Maintenance
Due 1 February 2016
Resolved 19 January 2016
Resolution: Received written correspondence of updated proceedures.
Deck/Cargo › Towing › Towline
Issued 23 December 2015
Resolved
Provide updated emergency proceedures for vessel in way of cable malfunction or parting of wire including rescue boat operation and launch proceedures.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 19 January 2016
Resolution: Written correspondence received
Engineering › Bilge Water Management System › Not Operational
Issued 29 July 2015
Resolved
Prove proper operation of bilge system in all compartmentsand ensure intake screens are attached at all suction sites. 46 CFR 182.25-1.
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 24 August 2015
Resolution: Attended vessel and cleared above deficiency.
Engineering › Bilge Water Management System › Pump
Issued 29 July 2015
Resolved
Properly install Jabsco PTO pump and prove proper operation. 46 CFR 182.25-10.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 24 August 2015
Resolution: Attended vessel and cleared above deficiency.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 July 2015
Resolved
Missinf 05 adult type I PFDs. Replace and check all lifejackets for SOLAS retro-reflective tape and labeling. 46 CFR 180-25-5/46 CFR 180.25-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 24 August 2015
Resolution: Attended vessel and cleared above deficiency.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 July 2015
Resolved
Replace missing heat protection on engine dry exhaust system. 46 CFR 182.15-20(g).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 24 August 2015
Resolution: Attended vessel and cleared above deficiency.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 July 2015
Resolved
Remove all dead end wires on propulsion barge. 46 CFR 176.25-50.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 24 August 2015
Resolution: Attended vessel and cleared above deficiency.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 July 2015
Resolved
Remove wing nut on battery for back-up propusion engine. 46 CFR 176.25-50.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 24 August 2015
Resolution: Attended vessel and cleared above deficiency.
Engineering › Lubricating Oil Service System › Hose
Issued 29 July 2015
Resolved
Hoses in way of exhaust are melted. Replace and protect from excessive heat. 46 CFR 176.25-50.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 24 August 2015
Resolution: Attended vessel and cleared above deficiency.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 July 2015
Resolved
Navication lights need to be in accordance with Navigation rules, Reg. 23 and Annex I. Switchable for both transits to and from Maryland.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 7 August 2017
Resolution: Verified at next annual inspection.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 13 August 2014
Resolved
Engine tachometer is not operational.
Condition: Improper Installation
Due 27 August 2014
Resolved 19 November 2014
Engineering › Fuel Oil Service System › Piping
Issued 13 August 2014
Resolved
Fuel return line needs support and protection from chaffing.
Condition: Improper Installation
Due 27 August 2014
Resolved 5 November 2014
Resolution: Fuel line supported and protected.
Engineering › Fuel Oil Service System › Piping
Issued 13 August 2014
Resolved
A small fuel leak exist between the fuel filter and the engine. Stop leaking to prevent risk of fire.
Condition: Improper/Lack of Maintenance
Due 27 August 2014
Resolved 5 November 2014
Resolution: Leak was stopped.
Lifesaving › Lifefloat › Lifeline
Issued 13 August 2014
Resolved
Replace lifelines on all liferings.
Condition: Improper/Lack of Maintenance
Due 27 August 2014
Resolved 19 November 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 July 2011
Resolved
Life Ring Light caseing fractured. Light still works. Repair/Replace and make water tight.
Action required: 705 - Other - as specified
Due 15 August 2011
Resolved 18 August 2011
Resolution: Received fax from O/Op showing the purchase of a new Ring Life Buoy Light.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 29 May 2007
Resolved
Renew gasket and/or fittings to provide seal between vessel connections of bilge manifold piping.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 7 June 2007
Resolution: Made repairs to system. Will conduct operational checks at later date.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 4 November 2003
Resolved
Provide approved Preventative Mantenance Plan for the vessel's hull as required by 46 CFR 176.630 for application for the Alternative Hull Examination program.
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 16 November 2004
Resolution: Finally!!
Lifesaving
Issued 24 June 1997
Resolved
Water light for ring buoy missing.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997