Inspection history · 82
4 April 2020
Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6935327
16 May 2019
Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6685863
9 May 2019
Damage Survey · Administrative Inspection · Permit to Proceed
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6680304
9 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6659024
13 July 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6481703
5 October 2017
Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6282238
4 October 2017
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6281558
4 October 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6334133
14 April 2017
COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6123982
13 March 2017
Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6103858
21 July 2016
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5947853
18 June 2015
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5167748
3 March 2015
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5077821
28 November 2014
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5030890
26 November 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5033429
25 November 2014
In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5030444
25 November 2014
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5036325
4 August 2014
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4943951
17 June 2013
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4624381
25 June 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4358725
13 December 2011
Drydock Exam · Internal Structural Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4207599
26 July 2011
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4095130
13 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3875111
3 October 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3862296
20 August 2010
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3840712
1 April 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3706939
14 September 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3594936
19 September 2008
Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3331578
18 September 2008
Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3325877
29 September 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3068977
6 June 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2954111
1 September 2006
Damage Survey · Internal Structural Exam · Hull Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2765989
1 August 2006
COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2732799
11 July 2005
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2422593
8 September 2004
MTSA Verification · Periodic Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2190628
20 August 2004
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2171559
9 August 2004
Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2161123
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1998698
18 November 2003
Cargo Tank Internal · Administrative Inspection · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1949182
10 October 2003
Examination of Repairs · Permit to Proceed · Hull Examination · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1900532
19 September 2002
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1677413
7 August 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1076294
7 August 2001
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1443231
12 April 2001
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1429530
18 October 2000
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1384591
21 September 2000
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1464320
18 August 1999
Damage Survey · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1124714
4 August 1999
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1415221
15 September 1998
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1404604
4 August 1997
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1428814
4 September 1996
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1425788
9 May 1996
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1407674
28 August 1995
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1404003
6 July 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 59224
12 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1374289
31 March 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1149050
17 March 1995
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 868535
6 October 1994
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1416030
15 September 1994
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1177312
17 June 1994
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1021375
17 September 1993
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1414192
19 February 1993
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 835679
6 August 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 957492
31 July 1992
Permit to Proceed
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 951021
13 May 1992
Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 952509
16 May 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1016425
18 June 1990
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 929837
14 February 1990
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 908594
2 June 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 887260
19 May 1989
Hull Examination · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1208202
11 August 1988
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1038299
1 July 1987
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1325121
21 May 1987
Hull Examination · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1335264
6 August 1986
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1307038
11 June 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1290871
15 May 1985
COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 986011
15 May 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1295000
8 May 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 977297
27 May 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 966791
18 May 1983
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 964313
3 August 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 968679
15 May 1981
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1273475
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 May 2019
Resolved
The subject vessel reported a failure to the primary cargo pump seal, resulting in approximately 100lbs of sulfur was reported spilled. Vessel shall conduct permanent repairs to the affected seal to the satisfaction of the attending CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2019
Resolved 16 May 2019
Resolution: MI verified a new seal was installed on the primary cargo pump at the deck to pump interface.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 9 May 2019
Resolved
The vapor control system of the subject vessel including the pressure/vacuum control valve are currently clogged with sulfur due to an overfilled tank. Permanent repairs to the vapor control system must be made prior to cargo operations including cargo discharge. If discharging cargo is required to conduct repairs, a discharge plan shall be submitted to USCG Sector Houston-Galveston for approval prior to discharge.
Action required: 705 - Other - as specified
Due 9 May 2019
Resolved 16 May 2019
Resolution: MI verified two vent headers and the associated deck vent pipeline have been cleaned and cleared of hardened Sulphur. New gasket material has been installed at the header to deck interface.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2019
Resolved
An electrical apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. Inspector observed a light switch in the engine room to be improperly installed. The unit was not mounted to the bulkhead and was being supported solely by the conductor. Vessel is required to repair electrical installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2019
Resolved 15 April 2019
Resolution: Outlet properly mounted and broken plug removed from socket. See image in documents.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 April 2019
Resolved
The prime mover to the generator was found with excessive oil/oily grime on the cooling fan and fan screen creating a increase hazard for fire. Possible cause for the excessive oil can be due to the prime mover missing its crankcase breather filter unit. Remove excess oil/oily grime.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2019
Resolved 15 April 2019
Resolution: Fan cleaned of all oil and dust. See image in documents.
Construction/Loadline › Hull › Transverse Frame
Issued 4 October 2017
Resolved
3 fractured frame bracket and one diagonal angle member that needs to be replaced approximately 12' down from the head log on the port side.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2017
Resolution: Witnessed air test
Construction/Loadline › Hull › Sheerstrake
Issued 4 October 2017
Resolved
Approximately a 3' x 4' upset on the port bow rack bilge knuckle at the transition, 3"-4" deep.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 11 October 2017
Resolution: Witnessed air test.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 June 2015
Resolved
Small battery box had insufficient support for the battery. Place support in the box for the batteries to prevent movement within the box.
Action required: 705 - Other - as specified
Due 19 June 2015
Resolved 19 June 2015
Resolution: Placed addtional support in existing battery box.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 18 June 2015
Resolved
Engine overspeed shutdown inoperable.
Action required: 705 - Other - as specified
Due 19 June 2015
Resolved 19 June 2015
Resolution: Company engineers completed necessary repairs and test was conducted satisfactorily.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 November 2014
Resolved
The goose neck vents onboard the DUVAL 1 were found to be fully obstructed due to the accumulation of sulfur. Goose neck vents must be cleaned and sulfur/obstructions removed prior to taking on cargo.
Action required: 705 - Other - as specified
Resolved 28 November 2014
Resolution: All vents onboard have been cleaned
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 13 December 2011
Resolved
In regards to the independent diesel fuel tank located on deck, install baffle plates IAW 46CFR58.50-10(a)(7-8). Prior to the commencement of work, submit and receive approval of repair plan that specifies material and minimum thickness of baffle plates, installation invervals, welding procedures/materials adn the number location of limber holes.
Due 12 February 2012
Resolved 25 June 2012
Resolution: Independent fuel tank was rebuilt IAW 46CFR58.50-10(a)(7-8). Tank was satisfactorily hydro tested and installed.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 26 July 2011
Resolved
Due to the fact that overspeed device on generator prime mover is not functioning generator may not be used to provide electrical power to barge until proper operation is proved IAW 46 CFR 111.12-1 to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2011
Resolved 28 July 2011
Resolution: Item repaired.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 September 2007
Resolved
Secure batteries in battery box.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2007
Resolution: Installed wood blocks to prevent batteries form sliding around.
Construction/Loadline › Structures › Scuttle
Issued 29 September 2007
Resolved
R/R wasted sounding tube opening IWO # 1 port Void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2007
Resolution: Cropped and renewed sounding tube.
Construction/Loadline › Hull › Bottom Plating
Issued 1 September 2006
Resolved
The vessel has a 2" hole in the first bay port side of the hopper. A temporary repair of shingles and water plug is in place. Vessel is required to make permanent repairs to the satisfaction of a Coast Guard Marine Inspector prior to conducting any cargo operations. Vessel is permitted to transit to Brady Island Shipyard to conduct permanent repairs.
Action required: 705 - Other - as specified
Due 3 September 2006
Resolved 28 September 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 9 August 2004
Resolved
Proceed to Galveston, Texas for discharge of cargo and to make permanent repairs to port cargo pump gasket.
Action required: 705 - Other - as specified
Due 13 August 2004
Resolved 20 August 2004
Resolution: Port cargo pump gasket replaced and tested.
Construction/Loadline › Hull › Hull Plating
Issued 9 September 2003
Resolved
There were low gauge readings in some areas of the side shell.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2003
Resolution: Proper repairs were made to side shell.
Construction/Loadline
Issued 18 August 1999
Resolved
HAVE HULL AVAILABLE TO EVALUATE DAMAGE TO THE SATISFACTION OF INSPECTOR ANDPRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 19 August 1999
Resolved 20 October 1999
Construction/Loadline
Issued 18 August 1999
Resolved
MAKE PERMANENT REPAIRS AND CONDUCT INSPECTION OF HULL TO THE SATISFACTION OF LOCAL OCMI PRIOR TO 25 AUG99.
Condition: Unknown
Due 25 August 1999
Resolved 20 October 1999
Construction/Loadline
Issued 4 August 1999
Resolved
MAKE PERMANENT REPAIRS TO HATCH PLATING ABOVE CARGO TANKS PRIOR TO NEXT LOADING AND TO THE SATISFACTION OF THE LOCAL OCMI.
Condition: Unknown
Due 14 August 1999
Resolved 17 August 1999
Deck/Cargo
Issued 4 August 1997
Resolved
PROVE PROPER OPERATION OF CARGO PUMP EMERGENCY SHUT DOWN.
Condition: Unknown
Due 4 September 1997
Resolved 12 August 1997
Engineering
Issued 4 August 1997
Resolved
PROVE PROPER OPERATION OF THERMAL HEATER IAW APPROVED PROCEDURES.
Condition: Unknown
Due 4 September 1997
Resolved 12 August 1997
Construction/Loadline
Issued 17 March 1995
Resolved
MAKE ONE WAY VOYAGE TO GALVESTON,TX TO OFF LOAD CARGO AND MAKE PERMANANT REPAIRS TO HULL IN WAY OF #2 STBD WING VOID.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Construction/Loadline
Issued 13 May 1992
Resolved
PROCEED TO SHIPYARD AND MAKE PERMANENT REPAIRS TO HOLED BOTTOM PLATING AND DECK HOUSING.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Fire Fighting
Issued 19 May 1989
Resolved
PROVIDE SERVICING REPORT FOR THE FOUR B-II DRY CHEMICAL FIRE EXTINGUISHERS ON BOARD TO THE SATISFACTION OF THE ATTENDING U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Deck/Cargo
Issued 19 May 1989
Resolved
CONDUCT HYDROSTATIC TEST OF CARGO LINE TO 1 1/2 MAWP, TO THE SATISFACTION OF THE ATTENDING U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Deck/Cargo
Issued 19 May 1989
Resolved
PROVE PROPER OPERATION OF EMERGENCY SHUTDOWNS FOR ELECTRIC CARGO PUMPS, TO THE SATISFACTION OF THE ATTENDING U. S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Electrical
Issued 19 May 1989
Resolved
PROVE PROPER OPERATION OF GENERATOR OVERSPEED TRIP TO THE SATISFACTION OF THE ATTENDING U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Construction/Loadline
Issued 21 May 1987
Resolved
FREE UP HATCH COVER SECURING DOGS AS NECESSARY LOCATED IN WAY OF HOPPER SPACE HOUSE ENCLOSURE. ABOVE REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] CARGO.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Deck/Cargo
Issued 21 May 1987
Resolved
PRIOR TO LOADING CARGO DEMONSTRATE OPERATION OF ELECTRICAL GENERATING PLANTEMERGENCY SHUTDOWN SYSTEM.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Construction/Loadline
Issued 21 May 1987
Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY REPAIRS MADE TO ALL PORT AND STBD WING VOID ULLAGE OPENINGS ABOVE REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] CARGO.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Unknown
Issued 15 May 1985
Resolved
TEST IN THE PRESCENCE OF A COAST GUARD MARINE INSPECTOR THE FOLLOWING: (A)CARGO PUMP ENGINE SHUTDOWN. (B)GENERATOR OVERSPEED. (C)THERMAL FLUID HTRSYSTEM. THIS ITEMS ARE TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANTO.C.M.I. VESSEL TO CONDUCT NO CARGO OPERATION UNTIL COMPLETED.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985