CBC 206

CBC 206 is a 1996 tank barge. The Coast Guard has recorded 48 inspections since 1996, most recently in July 2021, along with 16 deficiencies and 2 casualty investigations between 2015 and 2017.

Records from 1996 to 2021. Most recent: inspection, 26 July 2021.

Built
1996
Last inspected
26 July 2021
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

436197
Flag
UNITED STATES
Maury page id
psix-436197

Inspections, by type

…with no type recorded7
Years with a record 25 calendar years (1996–2021)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)195.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,061 / net 1,061
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE GROUP · GULFPORT, MS, UNITED STATES · built 1996
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 16 September 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1061 - Simplified, Gross Ton
1061 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 8

Inspection history · 48

26 July 2021 Examination of Repairs · Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7268735
11 September 2020 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7056075
18 October 2018 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6563648
12 September 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6262648
4 July 2017 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6313380
28 July 2016 Internal Structural Exam · Hull Examination · Examination of Repairs · COI Inspection · MTSA Verification · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5955996
22 March 2016 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5838360
29 February 2016 Damage Survey · Permit to Proceed · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5824708
27 February 2016 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5823805
17 July 2015 Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5185064
25 June 2015 Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5164223
10 June 2015 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5149472
9 June 2015 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5149553
11 May 2015 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5123889
15 July 2014 Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4923424
6 September 2013 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4710847
11 June 2013 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4617586
25 June 2012 Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4356629
21 June 2012 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4351348
27 July 2011 Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4094601
4 June 2010 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3757594
9 July 2009 Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3528977
26 June 2009 MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3514409
1 June 2009 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3492253
5 June 2008 MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3228002
4 May 2007 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2922160
26 February 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2877866
25 February 2007 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2877569
25 February 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2897062
28 June 2006 Hull Examination · Cargo Tank Internal · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2693323
6 July 2005 COI Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2417483
18 August 2004 Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2169519
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997034
24 September 2003 Examination of Repairs · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1912188
12 August 2002 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1660133
8 August 2001 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1069423
7 August 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1069421
2 August 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1393500
26 April 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 145153
9 August 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1388870
19 August 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1440046
17 March 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 83367
27 August 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1407946
10 June 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 118143
21 January 1997 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1098430
18 November 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1176132
30 September 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1143236
21 August 1996 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458334

Deficiency record · 16

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 29 February 2016 Resolved
Possible leaking gasket on cargo piping system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2016
Resolved 23 March 2016
Resolution: Cause of leak was a cracked weld seam on the cargo pump suction line. Upon testing of repairs to weld seam, another cracked weld seam was discovered. Addtional crack was also repaired and subsequent hydrostatic testing results were satisfactory.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 27 February 2016 Resolved
Barge was discovered with potential product in the stern void. A CG-835 was issued to proceed to Memphis, TN to locate, inspect and determine cause of leak.
Action required: 705 - Other - as specified
Resolved 23 March 2016
Resolution: Cause of leak was a cracked weld seam on the cargo pump suction line. Upon testing of repairs to weld seam, another cracked weld seam was discovered. Addtional crack was also repaired and subsequent hydrostatic testing results were satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 June 2015 Resolved
Twisted frames and bent and tripped gussets.
Condition: Damaged By Earlier Event
Due 9 July 2015
Resolved 17 July 2015
Resolution: Witnessed satisfactory repairs of all inserts and completed air tests of 1.5 psi.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 15 July 2014 Resolved
Prior to loading cargoes that require a closed gauging arrangement and/or the use of the vapor control system: prove proper operation of the high level/overfill alarm/shutdown system.
Action required: 705 - Other - as specified
Due 29 July 2014
Resolved 17 July 2014
Construction/Loadline › Structures › Superstructure
Issued 20 June 2009 Resolved
Routine inspection revealed water in the fwd compartment. Deck crew commenced pumping out compartment. MSD Vicksburg along with a surveyor and repair person went out on the CBC 206. A temp repair was place on the 10 inch wide by 1.5 inch split. The damage was located aprox 6 inches below the head log and aprox 20 ft from the port bow corner. Vessel was permitted to head to Joliet IL to off load.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2009
Resolved 13 July 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 26 February 2007 Resolved
Prior to loading any cargos which require a vapor control system IAW the vessels CAA prove that cargo tanks and vapor header are vapor tight IAW 40CFR61.302.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2007
Resolution: Vapor tightness test conducted satisfactorily at Hannah Marine. Test results attached to activity.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 26 February 2007 Resolved
Prove proper operation of the VCS header P/V valve IAW 33CFR156(g)(1).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2007
Resolution: Reissued 835 with new operational conditions.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 26 February 2007 Resolved
Test VCS header P/V valve and gauge IAW 33CFR156.170(g)(1) prior to loading cargoes that require a VCS after current Benzene cargo is offloaded.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 18 August 2004 Resolved
Emergency shut-down actuating cable incorrectly connected at diesel engine.
Condition: Improper Installation
Due 18 August 2004
Resolved 18 August 2004
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 August 2004 Resolved
Provide Vessel Response Plan Approval Letter.
Due 18 August 2004
Resolved 18 August 2004
Electrical › Lighting (service)
Issued 24 September 2003 Resolved
Repaint navigational light screen.
Due 19 October 2003
Resolved 24 September 2003
Resolution: Yard personnel repainted navigation screens.
Stability › Weathertight Integrity
Issued 24 September 2003 Resolved
Tighten dogs on starboard side #2 void. LEGACY COMPONENT DESC: Loose Dogs on void
Condition: Design Flaw
Due 19 October 2003
Resolved 24 September 2003
Resolution: Yard personnel tightened dogson void hatch.
Documentation
Issued 2 August 2000 Resolved
Provide copy of Fuel/Oil transfer procedures line diagram. Line diagram missing from procedures.
Condition: Unknown
Due 2 August 2000
Resolved 7 August 2000
Documentation
Issued 2 August 2000 Resolved
Provide copy of Response Plan Approval Letter. Letter missing from barge paperwork, not onboard barge.
Condition: Unknown
Due 2 August 2000
Resolved 7 August 2000
Deck/Cargo
Issued 2 August 2000 Resolved
Remove excess rainwater and oily residue mixture from catchment pan underneath cargo pump prime mover._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 2000
Resolved 7 August 2000
Deck/Cargo
Issued 21 August 1996 Resolved
REDUCE F/O HOSE LENGTH EQUAL TO/OR LESS THAN 30 INCHES ON CARGO PUMP ENGINEAS PER 46 CFR 56.60-25(c)2(a)4.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996

Casualty record · 2

9 June 2015Routine · role: Involved in a Marine Casualty · activity 5149553
4 July 2017Routine · role: Involved in a Marine Casualty · activity 6313380
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record