Records from 1985 to 2026. Most recent: inspection, 6 July 2026.
Inspection history · 271
6 July 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8430768
16 April 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8350668
7 April 2026
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8345042
7 April 2026
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8453486
4 February 2026
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8305979
1 January 2026
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8288999
8 December 2025
Vessel Attendance · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8271345
14 October 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8251973
25 August 2025
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8214983
17 August 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8211619
17 August 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8212965
19 July 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8189787
19 July 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8234845
9 July 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8180839
28 January 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8071221
7 August 2024
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7977082
29 April 2024
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7903204
26 February 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7877809
9 February 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7896436
31 January 2024
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7856420
26 July 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7754918
29 June 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7726700
19 April 2023
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7676293
17 February 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7639449
17 February 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7644748
26 January 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7810830
10 January 2023
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7613875
13 October 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7577063
29 August 2022
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7547586
19 August 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538427
5 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7525557
21 July 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7513079
6 July 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7498548
6 June 2022
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7473894
3 March 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7402123
3 December 2021
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7363226
30 September 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7324359
9 August 2021
Re-Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7283815
13 May 2021
Deficiency Check · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7195631
11 February 2021
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7138294
3 September 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7049219
5 August 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7026710
7 July 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001795
26 May 2020
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001777
7 March 2020
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6909506
4 November 2019
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6847422
15 October 2019
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6835129
15 October 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6841237
2 August 2019
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6773565
20 June 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6720479
15 May 2019
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6686759
28 February 2019
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6608431
18 December 2018
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6598998
19 October 2018
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6563930
7 August 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6504113
31 July 2018
MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6491695
5 June 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6434769
3 April 2018
MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379140
4 January 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6332460
27 November 2017
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6315495
25 August 2017
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6256964
9 May 2017
MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6138045
31 January 2017
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6080436
2 November 2016
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6034281
3 August 2016
MTSA/ISPS Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5962056
5 May 2016
Examination of Repairs · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5867126
16 October 2015
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5746152
10 October 2015
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5749664
22 September 2015
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5726261
15 August 2014
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4954937
17 June 2014
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4891434
15 May 2014
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4856616
21 May 2012
MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4311584
5 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202093
1 September 2011
Periodic Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4133780
17 February 2011
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3951210
7 February 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3941031
28 January 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3935165
3 December 2010
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3903340
18 October 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3872506
22 February 2010
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3685030
10 February 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3692719
14 July 2009
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3535367
15 April 2009
COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3452678
20 March 2009
Plan Review (Other than "T")
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3436949
6 January 2009
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3389512
3 October 2008
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3336612
22 July 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3278601
11 July 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3268586
3 July 2008
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3284045
6 May 2008
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3200398
3 April 2008
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3172341
16 March 2008
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3165999
21 February 2008
MTSA Verification · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3150385
16 December 2007
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3117829
11 October 2007
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3080379
19 May 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3183783
17 May 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2932926
15 May 2007
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2930989
19 April 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2911331
9 February 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2869687
21 January 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2859796
23 August 2006
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2757643
2 March 2006
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2594587
6 October 2005
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2512736
6 October 2005
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2516823
5 October 2005
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2508596
2 August 2005
MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2448851
11 July 2005
MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2423339
17 May 2005
Re-Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2366329
22 February 2005
Re-Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2312992
22 November 2004
Re-Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2246290
16 November 2004
MTSA Verification · Spot Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2242676
7 September 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2189780
3 September 2004
MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2185896
19 August 2004
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2169997
29 June 2004
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2115629
19 April 2004
Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2049567
17 March 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2031277
27 January 2004
Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1999218
22 December 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1969003
8 November 2003
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1947935
30 October 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1950380
23 October 2003
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1934081
26 June 2003
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1827632
19 May 2003
Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1797489
26 March 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1774954
11 January 2003
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1730403
11 January 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1735131
6 January 2003
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1726690
1 November 2002
Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1702226
13 August 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1664561
8 August 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1671133
30 July 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1654641
17 July 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1652395
5 June 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1632256
4 June 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1632754
18 August 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1420567
15 June 2001
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1065355
17 May 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1408739
8 February 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1467268
19 October 2000
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1054990
4 October 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1426473
18 September 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 822220
1 September 2000
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1452714
28 July 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 223781
5 July 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1433683
3 July 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 33251
13 April 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1369609
22 December 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 813435
14 December 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403005
30 August 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1469601
15 July 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 163028
23 May 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 182942
29 April 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1126312
23 March 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1375692
23 December 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 807872
7 December 1998
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1399014
20 September 1998
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1421560
15 September 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1372359
1 July 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 104825
16 June 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381268
10 April 1998
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1126950
16 March 1998
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1458500
29 December 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 782573
4 December 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1454505
28 October 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 778602
6 October 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 63139
18 September 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1406185
13 August 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 82012
11 August 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 164793
4 July 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 110285
26 June 1997
Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383593
23 June 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 167415
20 March 1997
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1451155
17 February 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1110134
10 February 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 109871
10 February 1997
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1105323
3 February 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1406040
13 January 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 31010
29 November 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 40457
22 November 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1179803
14 November 1996
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 863395
28 October 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1165962
26 September 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1385822
8 September 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 89765
24 July 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360580
12 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 54965
12 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 133565
10 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 125225
5 April 1996
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1448747
4 March 1996
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1355684
22 February 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1390196
22 November 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 7096
14 November 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1377549
5 September 1995
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1190574
15 August 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1367477
7 August 1995
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 881434
10 July 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2808
7 July 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 11265
7 July 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 78968
12 May 1995
Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1231337
3 May 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1377444
17 March 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357065
14 March 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 51419
4 November 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 866726
19 October 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1172779
13 October 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 184355
16 September 1994
Hull Examination · COI Inspection · Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1398094
3 May 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 44088
11 May 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 58409
6 May 1993
Re-Inspection · Drydock Extension
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1420737
21 January 1993
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1391808
11 December 1992
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1138365
24 September 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 943725
29 October 1991
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1004302
30 September 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 937354
30 September 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1249522
27 September 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1247421
23 July 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 999091
13 June 1991
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 930405
24 April 1991
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 925933
11 March 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 903613
8 March 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 903930
24 January 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 911957
31 December 1990
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 926761
6 November 1990
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 907841
25 September 1990
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1220309
7 August 1990
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1212676
7 May 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 902057
23 March 1990
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 916704
20 October 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1194571
17 October 1989
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1348941
19 September 1989
Deficiency Check · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1194022
24 August 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1209680
11 August 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 895468
1 June 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1038824
1 June 1989
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1196656
24 May 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1033157
8 May 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1032721
3 February 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1209360
11 January 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1194703
4 January 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1038812
13 December 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1209912
21 July 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1339767
3 June 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 886785
23 February 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1331784
11 January 1988
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1318955
8 January 1988
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1013806
14 December 1987
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1005011
19 October 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1019933
8 September 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1308246
25 August 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1031172
15 August 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1030519
28 July 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1333039
15 May 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1024361
5 May 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1018650
8 April 1987
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1020536
5 March 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1007219
27 January 1987
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1318450
17 November 1986
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1017608
12 September 1986
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1309018
27 August 1986
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1298468
20 May 1986
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 995749
6 May 1986
Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1298457
14 March 1986
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1305578
26 February 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1298276
28 January 1986
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 999794
11 October 1985
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1297477
30 August 1985
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 985417
3 May 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 979573
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 July 2026
Resolved
All marine engineering details such as piping, valves, fittings, boilers, pressure vessels, etc., and their appurtenances installed on the vessel, shall be designed, constructed, and installed in accordance with the provisions of subchapter F (Marine Engineering) of this chapter. MI received report of a cracked fuel oil pipe on the vessel's No. 1 main propulsion diesel engine, causing active leakage. O/o shall replace the damaged pipe on the No. 1 main propulsion engine in accordance with approved marine engineering standards, test the system under working conditions, and prove satisfactory operation to the attending Marine Inspector prior to returning the engine to service.
46 CFR 70.20-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2026
Resolved 8 July 2026
Resolution: Replaced fuel oil pipe with in-kind replacement.Operational tests were satisfactory to attending MI.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 7 April 2026
Resolved
In the event of an accident to a boiler, unfired pressure vessel, or machinery tending to the render the further use of the item unsafe until repairs are made, a report shall be made by the chief engineer immediately to the OCMI. A notification was made but the wrong Ferry Quick Reference guide was utilized. When the TILLIKUM lost one of the two main engines, the vessel should have been in "take home mode only". The vessel continued with its service for at least one more stop before taking itself out of service. All WSF vessels and operators shall use the most current and approved Ferry Quick Reference Guide. 46CFR78.33-5a
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 April 2026
Resolved 7 April 2026
Resolution: Provided WSF current guide.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 January 2026
Resolved
Vessel reported a fuel leak on the crossover manifold connecting fuel banks on propulsion generator #1. Vessel is authorized to continue service with passengers IAW approved WSF matrix, USCG will attend vessel to attest to satisfactory repairs.
46CFR71.55-5(a)
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 1 January 2026
Resolution: Satisfactory repair witnessed by attending MI
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 December 2025
Resolved
Door closers removed from fire screen doors in emergency generator space. Replace closers.
Action required: 10 - Deficiency Rectified
Due 9 January 2026
Resolved 10 December 2025
Resolution: Closers replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2025
Resolved
Relief valve at the whistle tank reducing station will not reseat. Repair or renew relief valve.
Action required: 10 - Deficiency Rectified
Due 9 January 2026
Resolved 10 December 2025
Resolution: Relief valve renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2025
Resolved
Steam heating system condensate return pipe adjacent to the boiler flat has an external temperature greater than 150 degrees F.
Action required: 10 - Deficiency Rectified
Due 9 January 2026
Resolved 10 December 2025
Resolution: Piping lagged.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 October 2025
Resolved
Each passenger vessel of 500 tons gross tonnage and over must carry on each side of the vessel at least one rescue boat approved under approval series 160.156 that is equipped as specified in table 199.175 of this part.
The #2 rescue boat is inoperable. Vessel shall reduce pax capacity by 50% until rescue boat is fully operational and tested.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 15 October 2025
Resolution: Inoperable rescue boat was replaced with a spare. Operational test completed. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 August 2025
Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions.
Properly troubleshoot root cause of loss of propulsion and provide proof of repairs to CG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2025
Resolved 18 August 2025
Resolution: O/o provided root cause analysis report, completed repair/replacement of #1 gen voltage regulator IAW manufacturer's instructions, and successfully performeed sea trials with no further errors. Reports uploaded to Deficiency -> Documents Tab
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 July 2025
Resolved
Operating generators must provide a continuous and uninterrupted source of power for the ship's service load under normal operational conditions.
Properly troubleshoot root cause of loss of propulsion and provide proof of repairs to CG.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2025
Resolved 20 July 2025
Resolution: Replaced UPS and then completed satisfactory dock trials and sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2025
Resolved
Aux steam boiler is only equipped with one low water cut off device. ASME/ANSI CSD-1 (incorporated by reference) requires two such devices. Install a second low water cut off device in accordance with all code requirements at the vessel's next yard period.
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 27 February 2025
Resolution: Received email from C/E attesting to the installation and proper function of the second low low water cut out. Email included photos.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 January 2025
Resolved
Approximately 155 gallons of combustible liquids in 5 gallon containers is being stored in the machinery space. 46 CFR Subchapter N only allows 55 gallons of combustible liquid stores to be kept in the machinery space. Relocate excess combustible liquid outside the machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 6 February 2025
Resolution: Received email from C/E with photos showing the combustible had been moved to a location outside the machinery space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2025
Resolved
Wiring to heater fan (over boiler) includes an inappropriate inline splice. Provide continuous cable connection or splice in accordance with IEEE Standard 45.
Action required: 10 - Deficiency Rectified
Due 5 February 2025
Resolved 5 February 2025
Resolution: Cable replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 January 2025
Resolved
Numerous fire doors in the machinery spaces found with manual hold backs installed. Hold backs are only allowed if they can be remotely released. Remove manual hold backs on fire doors in the engineering spaces.
Action required: 10 - Deficiency Rectified
Due 5 February 2025
Resolved 5 February 2025
Resolution: Hold backs removed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 August 2024
Resolved
Illustrations and instructions must be conspicuously displayed at each muster station; the method of donning life jackets. Life Jacket drop points on all four corners of vessel car deck missing required signage.
46CFR199.80(c)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2024
Resolved 25 September 2024
Resolution: Evidence of purchase order produced to attending MI
08 - Alarms › N/A - No Subsystem › General alarm
Issued 7 August 2024
Resolved
All general alarm bells shall be identified by red lettering at least 1/2 inch high: "GENERAL ALARM - WHEN BELL RINGS GO TO YOUR STATION." All general alarm bells on vessel car deck missing signage, signage faded and/or missing throughout vessel.
46CFR78.47-7(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2024
Resolved 25 September 2024
Resolution: Evidence of purchase order produced to attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2023
Resolved
Each auxiliary boiler must be available for examination by the marine inspector at intervals specified by Table 61.05-10. Boiler valve inspection required as per Table 46 CFR 61.05-10 has not been conducted within 5 years from the date of the last inspection. Vessel to make boiler valves available for inspection at next scheduled drydock. 46 CFR 61.05-10(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2023
Resolved 5 February 2025
Resolution: Boiler inspections and tests up to date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2022
Resolved
(a) Each self-propelled vessel, except as provided in paragraph (d) of this section, must have an electric or mechanical engine order telegraph system from the navigating bridge to the engine room.
(c) On a double-ended vessel that has two navigating bridges, this system must be between the engine room and each navigation bridge.
Engine order telegraph cable on number two end is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 14 October 2022
Resolution: Replaced engine order telegraph cable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2022
Resolved
The main steering gear must be of adequate strength for and capable of steering the vessel at maximum ahead service speed, which must be demonstrated to the satisfaction of the cognizant Officer in Charge Marine Inspections. At normal operating speeds the pedestal bearing oil unit is showing a high temperature alarm.
Cite: 46 CFR 58.25-10(b)(1)
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2022
Resolution: Replaced pedestal bearing and conducted sea trials. All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 March 2022
Resolved
Prove the proper operation of the AMS and propulsion control systems. When attempting to prove PSTP PCS-13 the failure of the AUX 1 PLC did not leave the propulsion system unaffected. Propulsion control was lost from each pilothouse. 46 CFR 62.25-25, Code 60 c
Action required: 60 - Rectify deficiencies prior to movement
Due 8 March 2022
Resolved 8 March 2022
Resolution: Tested system. All Sat
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 March 2022
Resolved
Provide a means to acknowledge and silence the annunciator for the EOT failure in both the pilot house and the engineer's operating station. 46 CFR 62.25-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2022
Resolved 10 January 2023
Resolution: Witnessed PSTP related to EOT failure and capability to silence alarm.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 March 2022
Resolved
Separate the over-speed alarm from the other safety shutdowns,the main propulsion prime movers safeties e.g. e-stop, CO2, etc. also result in an over-speed indication. Alarms must be independent of each other. 46 CFR 62.25-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2022
Resolved 10 January 2023
Resolution: Witnessed alarm for main propulsion prime movers e-stop. Reason for deficient condition due to poorly written PSTP.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 March 2022
Resolved
Update the the vessel's PSTPs to reflect the condition
found on the vessel. The majority of the procedures and
the expected results did not match the condition found
on the vessel as noted on the shipboard copy dated
2021-2022. Submit the revision to the USCG MSC for
approval. 46 CFR 61.40-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2022
Resolved 31 January 2024
Resolution: PSTP's were updated and reflected proper procedures to test equipment. All were approved by MSC.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 3 March 2022
Resolved
Repair the fractured butt weld in way of the overhead
deck transverse stiffener located in the No.2 steering
gear room and above the e-steering station. 46 CFR 72.01-15\
Repair at next DDX.
Action required: 705 - Other - as specified
Due 17 March 2022
Resolved 10 January 2023
Resolution: Butt weld in #2 steering gear room repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 March 2022
Resolved
Repair the inoperable RPM indicators located in the
central control station. 46 CFR 62.25-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2022
Resolved 17 March 2022
Resolution: WSF submitted video of the RPM inicator working.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 March 2022
Resolved
Prove all non-completed PSTPs. The engineering systems were not ready for inspection. 46 CFR 61.40-6, Code 701 c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 March 2022
Resolved 8 March 2022
Resolution: Tested- All Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2021
Resolved
Electrical installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions.
Vessel received a ground fault on #2 generator on 9/28/21 and conducted maintenance to rectify the issue. Received same ground fault on 9/30/21.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2021
Resolved 1 October 2021
Resolution: Resolved deficiency in order to issue updated deficiency with prior to carriage of passengers code.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 February 2021
Resolved
Qualify the emergency power system. The frequency continually surges 60-69 hz, and when a load is applied the amps and voltage fluctuates for approx. 10 seconds. 46 CFR 112.05-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2021
Resolution: Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 February 2021
Resolved
Reconnect and qualify the remote operating valves serving the fire main/sprinkler isolation valve and the dirty oil tank which were found disconnected.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2021
Resolution: DEficiency corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 February 2021
Resolved
Prove the proper operation of the low lube oil alarm on the in-port generator as it was inoperable during the test. Prove the proper operation of the e-gen over-crank alarm, it worked 1 out of 4 attempts.
46 CFR 62.35-50
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2021
Resolved 3 December 2021
Resolution: Completed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 February 2021
Resolved
Prove proper operation of emergency steering from the steering gear compartment.
46 CFR 58.25-70(k)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2021
Resolution: Marine inspector witnessed proper operation.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 February 2021
Resolved
Mark all valves which may be used in an emergency in at least 1" letters identifying the system and the direction of operation. The emergency fuel shut off valves located on the main deck were not easily identifiable and were not minimally marked. 46 CFR 78.47-38
Due in 7 days.
Action required: 705 - Other - as specified
Due 19 February 2021
Resolved 3 December 2021
Resolution: During deck walk of quarterly, noted that valves were poperly marked with placards at valves.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 February 2021
Resolved
The black line on the ring buoy near the #1 rescue boat is deteriorating. Required to replace line.
46 CFR 70.28-1
46 CFR 199.70(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2021
Resolved 29 April 2021
Resolution: Crew fixed ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2021
Resolved
Update periodic safety tests, incorporating all notes taken by the crew and CG inspectors. 46 CFR 61.40-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2021
Resolved 3 December 2021
Resolution: Revised PSTP on 24FEB2021. Vessel had revision onboard during quarterly inspection.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 February 2021
Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, sop valve controls and in the CO2 cylinder storage room. The instructions did not match the labeling of the CO2 pulls. 46 CFR 76.15-10(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2021
Resolved 3 December 2021
Resolution: CO2 pull instructions have been updated.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 February 2021
Resolved
Class 3 sliding watertight door must operate in accordance with incorporated reference ASTM F1197. Door does not close completely, with an approximate 1" gap from full closure. Limit switch is inoperable. 46 CFR 170.270(c)(1)
Action required: 10 - Deficiency Rectified
Resolved 12 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2021
Resolved
As designed and noted in the periodic safety test procedures, #2 main diesel engine did not shut upon activation of the fixed fire extinguishing system. Corrected on the spot. 46 CFR 61.40-6(a)
Action required: 10 - Deficiency Rectified
Resolved 11 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 February 2021
Resolved
Boiler safety controls must control and cycle the unit in the proper manner and sequence. According to the PSTP, the boiler's pressure limit control's setting was
9 PSI but the boiler did not secure until 12 PSI. The switch setting indicated it was set at 9 PSI. 46 CFR 61.35-3 (a)(1) & (a)(8)
Action required: 10 - Deficiency Rectified
Resolved 12 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2021
Resolved
The hot water heating boiler must have at least one safety relief valve. The safety relief valve was marked for 15 PSI. The relief valve did not relieve at 15 PSI and the crew member utilized the remote hand pull to relieve the pressure at 17 PSI. 46 CFR 53.05-2(b)
Action required: 10 - Deficiency Rectified
Resolved 12 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 11 February 2021
Resolved
Boiler sight glass missing all 4 guards. 46 CFR 71.25-50
Action required: 10 - Deficiency Rectified
Resolved 12 February 2021
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 7 July 2020
Resolved
Wasteage on vehicle deck beyond tolerance.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 July 2020
Resolved 24 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 March 2020
Resolved
In all ventilation systems, annually operated dampers or other suitable means shall be provided in accessible locations, for the shutting off the passage of air in the event of fire. The Engine room NO2 Supply fire damper is not operating properly. 46CFR72.05-50(i) 701 C Vessel requested an extension for 30 days. Granted with the requirement to wire shut the damper and not use the fan, until fixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 26 May 2020
Resolution: Crew was able to replace the cable on the engine room damper. Tested. all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 February 2019
Resolved
The lifesaving plan onboard the vessel does not accurately reflect the amount of lifejackets onboard. Update plan to reflect the change in amount and location of lifejackets. Submit plans to the Officer in Charge, Marine Inspections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 9 April 2019
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 April 2018
Resolved
Replace SOLAS Tape on 238 lifejackets to the satisfaction of USCG Marine Inspector. 46 CFR 199.70.b.3.ii
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 6 April 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 April 2018
Resolved
#1 and #2 end port car deck lifebuoy needs re-stenciling. Stencil vessel name onto lifebuoy. 46 CFR 199.70(2)
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Lifesaving › Lifebuoys › Serviceable
Issued 3 April 2018
Resolved
06 lifebuoys SOLAS tape worn. Replace SOLAS tape. 46 CFR 199.70
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 April 2018
Resolved
03 Lifebuoy grablines wasted. Replace grablines on lifebuoys. 46 CFR 199.70(3)(i)
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Fire Fighting › Fire Hoses › Condition
Issued 3 April 2018
Resolved
Fire Station #11 hose has pinhole leak. Hose cut in front of inspector. Replace hose. 46 CFR 76.10-10
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Lifesaving › Rescue Boat › Markings
Issued 3 April 2018
Resolved
SOLAS Tape worn. Replace SOLAS Tape on both rescue boats. 46 CFR 156-7(28)
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Engineering › Steam Boiler (auxiliary/waste heat) › Water Wall
Issued 25 August 2017
Resolved
Make permanent repairs to ship service boiler to include hydrostatic testing
Action required: 705 - Other - as specified
Due 5 October 2017
Resolved 31 October 2017
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 25 August 2017
Resolved
Make repairs to ventilation fan motor servicing #2 void/steering space
Action required: 705 - Other - as specified
Due 25 September 2017
Resolved 31 August 2017
Resolution: Vent fan replaced.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 9 May 2017
Resolved
Repair three fire damper closure listed below, 1. Shaft alley access Nat exhaust (#2 end)
2. EOS supply fire damper 3. EDR supply fire damper.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 11 May 2017
Resolution: Fix all three inop dampers
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 9 May 2017
Resolved
Vessel needs new FCC "communication act safety radiotelephony and bridge to bridge certificate"
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 11 May 2017
Resolution: Vessel obtained new FCC certs.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 9 May 2017
Resolved
Prove local operation of watertight of watertight doors and indication light on bridge after closure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 11 May 2017
Resolution: Tested watertight door closures locally and from bridge, all sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 May 2016
Resolved
Ensure proper operation of #2 MDE fire damper at generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 6 May 2016
Resolution: Repaired fire damper.
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 5 May 2016
Resolved
Ensure proper operation of #1 MDE shutdown via fixed CO2 deployment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 6 May 2016
Resolution: Repaired shutdown relay.
Accommodation/Occupational Safety › Ventilation › General
Issued 5 May 2016
Resolved
Ensure proper operation of vent damper shutdown in #2 passenger cabin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 6 May 2016
Resolution: Serviced shutdown switch.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 May 2016
Resolved
Ensure proper operation of #2 ens, port exit light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Replaced light.
Lifesaving › Rescue Boat › Seating
Issued 5 May 2016
Resolved
Prove proper operation of Rescue boat & davit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2016
Resolution: Operational test of rescue boat #1 & davit, all sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 February 2011
Resolved
Ring lifebuoy on cardeck did not have any retro-reflective tape.
Condition: Design Flaw
Due 17 February 2011
Resolved 17 February 2011
Resolution: Crew has retro-reflective tape onboard to make repairs
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 February 2011
Resolved
Buoyant lifeline on ring lifebouy located on passenger deck was wasted due to weather
Due 17 February 2011
Resolved 17 February 2011
Resolution: Vessel had spare lifebuoy onboard
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 17 February 2011
Resolved
Provide guaranteed open deck area outside emergency gear locker on vehicle deck, stbd side to facilitate preparing gear and dressing out in an emergency situation
Action required: 705 - Other - as specified
Due 31 May 2011
Resolved 19 May 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 15 April 2009
Resolved
Demonstrate proper operation of the CO2 shutdown for #2 MDE.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 April 2009
Resolution: Witnessed sat operational test of #2 MDE Genset CO2 activated pressure switch shutdown.
Engineering › Pressure Vessel › Relief Valve
Issued 15 April 2009
Resolved
Demonstrate proper operation of ship's horn air receiver pressure relief valve.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 April 2009
Resolved 16 April 2009
Electrical › Electric Generation Source (emergency) › Switch
Issued 15 April 2009
Resolved
Demonstrate proper operation of the high J/W temp alarm.
Due 16 April 2009
Resolved 16 April 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 April 2009
Resolved
Fix PFD dropped down stowage bins (total of 4) in way of car deck area to release all PFD properly.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 April 2009
Resolved 16 April 2009
Fire Fighting › Fire Hydrants › Condition
Issued 3 April 2008
Resolved
Repair or replace station #2 valve from leaking by when closed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 3 April 2008
Fire Fighting › Structural - Horizontal Zones › General
Issued 3 April 2008
Resolved
Replace painted fusible links for #1 end, stbd, #1 and #2 engine room supply ventilation shutdown devices. Make operational #1 end, port #1 supply forced supply vent shutdown.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 3 April 2008
Construction/Loadline › Hull › Hull Plating
Issued 16 December 2007
Resolved
Where hull plate degradation beyond 25% was identified, monitoring is required weekly by crew and monthly by an attending Marine Inspector. If any change to the material condition is detected (fractures/leaks), WSF must notify the USCG immediately. Vessel is to be dry-docked within the next 4 months, not later than 1 MAY 2008.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 19 May 2008
Resolution: Completed as per ACT#3200398.
Construction/Loadline › Hull › Hull Plating
Issued 16 December 2007
Resolved
A thorough assessment and detailed mapping of identified wastage must be documented prior to receiving drydock credit. Submit written repair proposals for all wastage beyond 25%. Develop preservation plans for areas where coating failure is evident and where wastage is <25%.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 19 May 2008
Resolution: Completed as per ACT#3200398.
Fire Fighting › Fire Hydrants › Condition
Issued 11 October 2007
Resolved
Reseat leaking fire main valve at station #11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2007
Resolved 15 October 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 17 May 2007
Resolved
Demonstrate proper operation of #1 engine room exhaust damper on the texas deck.
Due 22 May 2007
Resolved 22 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2007
Resolved
Properly wire lighting in crew deck house on the car deck.
Due 22 May 2007
Resolved 22 May 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 17 May 2007
Resolved
Demonstrate proper operation of #2 end magnetic compass backlight.
Due 22 May 2007
Resolved 22 May 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 17 May 2007
Resolved
Repair/replace damaged light cage on explosion proof lighting in battery room.
Due 22 May 2007
Resolved 22 May 2007
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 17 May 2007
Resolved
Properly secure spare SCBA bottles in emergency lockers.
Due 22 May 2007
Resolved 22 May 2007
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 5 October 2005
Resolved
Prove proper operation of #1 Rescue Boat davit, Auth manual lowering in interim.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 6 October 2005
Resolution: Timing curcuit replaced, tested davit 3 complete cycles, test sat.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 19 August 2004
Resolved
Prove proper operation (i.e. complete closure) of the #1 Engine Room exhaust dampers, port & starboard, Texas Deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 30 August 2004
Fire Fighting › Ventilation Systems › Operating Controls
Issued 19 August 2004
Resolved
Prove proper operation (i.e. complete closure) of the #2 Engine Room exhaust damper, starboard side, Texas Deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 30 August 2004
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 23 October 2003
Resolved
Prove proper operation of loss of steering power/control, audible alarm, both #1 and #2 end wheelhouse.
Due 8 November 2003
Resolved 31 October 2003
Stability
Issued 26 June 2003
Resolved
A new stability letter based on newly established lightship characteristics must be posted on your vessel.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 19 August 2003
Resolution: New stability letter issued.
Stability
Issued 26 June 2003
Resolved
Not more than 800 passengers may be carried until revised loading conditions are reviewed by MSC and new stability letter is issued.
Action required: 705 - Other - as specified
Resolved 19 August 2003
Resolution: New stability letter issued permitting carriage of 1200 passengers.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 January 2003
Resolved
There were an inadequate number of floating electric waterlights on board IAW vessel's COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2003
Resolution: Vessel mounted needed waterlights.
Navigation › Piloting/Steering
Issued 9 January 2003
Resolved
Magnetic compass lights were extinguished in both pilot houses. LEGACY COMPONENT DESC: Magnetic Compass
Due 10 January 2003
Resolved 10 January 2003
Resolution: Compass lights were replaced immediatly.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 January 2003
Resolved
Lifejacket storage bin on cardeck would not close. The metal door was bent.
Due 10 January 2003
Resolved 10 January 2003
Resolution: Lifejacket storage bin was repaired.
Fire Fighting › Self-contained Breathing Apparatus
Issued 9 January 2003
Resolved
[name withheld] regulator was beyond service date. LEGACY COMPONENT DESC: Valve
Due 10 January 2003
Resolved 10 January 2003
Resolution: Air regulation was replaced.
Operations/Management › Navigation Safety
Issued 30 July 2002
Resolved
Prior to getting underway, provide Navigation Safety Regulations for #2 Pilothouse. LEGACY COMPONENT DESC: Rules
Condition: Unknown
Due 1 August 2002
Resolved 1 August 2002
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 30 July 2002
Resolved
Prior to getting underway provide five(5) additional child lifejackets.
Condition: Unknown
Due 1 August 2002
Resolved 1 August 2002
Fire Fighting › Fire Hoses › Condition
Issued 30 July 2002
Resolved
Prior to getting underway replace one(1) fire hose.
Due 1 August 2002
Resolved 1 August 2002
Engineering › Steam Boiler (auxiliary/waste heat) › Inner Casing
Issued 30 July 2002
Resolved
Repair leak between cast sections of boiler and hydro test to 1 1/2 MAWP.
Condition: Unknown
Due 1 August 2002
Resolved 1 August 2002
Engineering
Issued 23 March 1999
Resolved
Demonstrate proper operation of overspeed shutdown device for #2 Main Diesel Engine.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Navigation
Issued 20 September 1998
Resolved
MATHEWS STEERING GEAR MULTILEVEL SWITCH NO 1 END FAILED, CAUSING RUDDER TO FAIL IN THE HARD LEFT POSITION.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998
Electrical
Issued 16 March 1998
Resolved
DEMONSTRATE OPERATION OF OVERSPEED TRIP FOR #1 MAIN DIESEL ENGINE.
Condition: Unknown
Due 18 April 1998
Resolved 20 May 1998
Electrical
Issued 16 March 1998
Resolved
PROVE OPERATION OF REVERSE POWER RELAYS FOR BOTH MAIN DIESEL GENERATORS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 April 1998
Resolved 20 May 1998
Construction/Loadline
Issued 4 December 1997
Resolved
VEE AND WELD FRACTURE WELDS LOCATED IN #1 AND #2 END STEERING GEAR ROOMS OVERHEAD AREA IN A WAY OF CAR DECK TO BE COMPLETED PRIOR TO 11 DECEMBER 1997 TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Construction/Loadline
Issued 4 December 1997
Resolved
PROVIDE WRITTEN PROPOSAL TO OCMI FOR MAKING PERMANENT REPAIRS TO FRACTURES FOUND IN THE STEERING GEAR ROOMS TO BE COMPLETED PRIOR TO 04 JANUARY 1998._x001C_THESE AREAS HAD BEEN REWELD SEVERAL TIMES AND FOUND TO BE A RE-OCCURING PROBLEM THAT NEED TO BE RESOLVED.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Engineering
Issued 4 December 1997
Resolved
MAKE READY AND AVAILABLE FOR FIRE AND WATERSIDE EXAMINATION THE AUXIALIARY BOILER PRIOR TO 11 DECEMBER 1997. THIS REQUIRED EXAM IS PAST DUE SINCE SEPTEMBER 1997.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Lifesaving
Issued 4 December 1997
Resolved
VESSEL IS RESTRICTED TO CARRYING TOTAL PASSENGERS TO 1120 PERSONS DUE TO 20MISSING LIFE PRESERVERS FROM UNDERNEATH ONE OF THE BENCH SEATS ON THE PASSENGER DECK STARBOARD SIDE FACING NO.1 END.
Condition: Unknown
Due 28 February 1998
Resolved 8 December 1997
Lifesaving
Issued 18 September 1997
Resolved
PROVIDE COUNT OF LIFEJACKETS ENSURING AMOUNT ON BOARD MATCHES OR EXCEEDS NUMBER REQUIRED BY C.O.I..
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Lifesaving
Issued 18 September 1997
Resolved
MAKE REPAIRS TO #2 RESCUE BOAT. CRACK IN TRANSOM, PORT SIDE OF MOTOR MOUNT.
Condition: Unknown
Due 1 October 1997
Resolved 19 September 1997
Navigation
Issued 26 June 1997
Resolved
Submit CG-2692 outlining steering deficiency. Make repairs and demonstrate proper operation of steering gear, #1 and #2 ends.
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Electrical
Issued 20 March 1997
Resolved
#1 END PORT NAVIGATION LIGHT PANEL FILIMENT NOT WORKING. FILIMENT REPLACEDON THE SPOT.
Condition: Unknown
Due 2 April 1997
Resolved 2 April 1997
Lifesaving
Issued 20 March 1997
Resolved
CHILD PFD COUNT WAS 112 COI REQUIRES 115. 3 CHILD PFDS PROVIDED ON THE SPOT.
Condition: Unknown
Due 2 April 1997
Resolved 2 April 1997
Lifesaving
Issued 20 March 1997
Resolved
2 GENERAL ALARM BELLS ON CAR DECK STBD SIDE HAD CORROSION AND DID NOT FUNCTION PROPERLY. BELLS REPLACED ON THE SPOT.
Condition: Unknown
Due 2 April 1997
Resolved 2 April 1997
Navigation
Issued 3 February 1997
Resolved
POST STEERING INSTRUCTIONS/PROCEDURES IN BOTH STEERING GEAR SPACES.
Condition: Unknown
Due 10 February 1997
Resolved 19 February 1997
Engineering
Issued 3 February 1997
Resolved
REPLACE UPPER START AIR TANK (2ND FROM DECK) PRESSURE RELIEF VALVE.
Condition: Unknown
Due 10 February 1997
Resolved 19 February 1997
Engineering
Issued 26 September 1996
Resolved
REPAIR AS ORIGINAL, THE OUTER CASING OF BOILER; PANEL AND INSULATION REMOVED - BOILER WAS EXPOSED.
Condition: Unknown
Due 10 October 1996
Resolved 8 October 1996
Engineering
Issued 26 September 1996
Resolved
IN ACCORDANCE WITH 46 CFR 61.10-5, CONDUCT THE REQUIRED INTERNAL EXAMINATION OF ALL UNFIRED PRESSURE VESSELS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN 22OCT96.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Fire Fighting
Issued 24 July 1996
Resolved
REPAIR F.S.D. #1 TO CLOSE PROPERLY.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Engineering
Issued 5 April 1996
Resolved
VSL DID NOT HAVE MSC APPROVAL LTR OF VITAL SYSTEMS PERIODIC SAFETY TEST PROCEDURE.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 14 November 1995
Resolved
REPAIR THE AUDIO & VISUAL LOW LUBE OIL ALARM INSTALLED ON THE #1 MAIN PROPULSION GENERATOR.
Condition: Unknown
Due 29 November 1995
Resolved 1 December 1995
Lifesaving
Issued 15 August 1995
Resolved
SECURE ALL STORAGE LOCKERS,WASHER,CUTOFF SAW,AND REFRIGERATOR TO PREVENT MOVEMENT.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Construction/Loadline
Issued 15 August 1995
Resolved
CLEAN OUT HATCH COMBINGS AND FREE UP OPERATION.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Construction/Loadline
Issued 15 August 1995
Resolved
PROVE PROPER OPERATION OF WTD AND INDICATORS AND LIGHTS.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Fire Fighting
Issued 15 August 1995
Resolved
PROVIDE SCHEMATIC AT CO2 PULL STATION IAW 46CFR76.15-10(h)
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Electrical
Issued 15 August 1995
Resolved
MAKE ELECTRICAL PLUGS FOR WASHER AND REFRIGERATOR WATERTIGHT.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Electrical
Issued 7 August 1995
Resolved
PROVIDE PROOF THAT COMMENTS OF MSC-2 LTR SERIAL E2-9502924 DTD 26JUL95_x001C_ HAVE BE RESPONDED TO AND THAT MODIFICATION TO MAIN SWITCHBOARD BUS-TIE _x001C_ CIRCUIT BREAKER HAVE BEEN COMPLETED.
Condition: Unknown
Due 7 August 1995
Resolved 7 August 1995
Accommodation/Occupational Safety
Issued 12 May 1995
Resolved
PROVIDE APPROPRIATE GUARDS OR RAILS INWAY OF ROTATING SHAFTS OF #1 MOTOR OUTBOARD SIDE.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Engineering
Issued 12 May 1995
Resolved
PROVIDE PROOF THAT COMMENTS IN MSC-2 LTR SERIAL # E2 9501395 DATED 27APR95 ARE ADDRESSED AND RESPONDED TOO.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Electrical
Issued 17 March 1995
Resolved
REPLACE THE COLLAPSED RUBBER SHOCK MOUNTS SUPPORTING NO.3&4 SCR CABINET CONTAINING ROSS HILL CONTROL MODULES A&B LOCATED IN THE NO.2 END ENGINEROOM.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Engineering
Issued 16 September 1994
Resolved
SUBMIT FOR APPROVAL PERIODIC SAFETY TEST PROCEDURE FOR PROPULSION CONTROL SYSTEM TO COGNIZANT OCMI_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 16 September 1994
Resolved
INSTALL AUDIBLE ALARM IN MACHINERY SPACES TO ACTIVATE UPON ANY ALARM CONDITION FOR COMPLIANCE WITH MSC LTR E2-94025990 DTD 12SEP94_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Fire Fighting
Issued 24 September 1992
Resolved
REPAIR/REPLACE WINDOW IN FIRE SCREEN DOOR ON PORT SIDE #2 END MEZZANINE LEVEL.
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Engineering
Issued 23 July 1991
Resolved
MAKE REPAIRS AS NECESSARY TO LEAKS IN THE AUXILIARY BOILER AND HOLES IN THEBOILER CASING. UPON COMPLETION PERFORM A 1 1/2 MAWP HYDRO TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Engineering
Issued 8 March 1991
Resolved
RENEW/REPLACE/REPAIR SAFETY VALVE ON L.P. HEATING BOILER AND PROVE PROPER OPERATION OF RELIEF AT OR BELOW 15 PSI TO CG INSPECTOR PRIOR TO OPERATING BOILER.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 7 August 1990
Resolved
PROVE PROPER OPERATION OF NO. 2 SHIP'S SERVICE GENERATOR OVERSPEED TRIP ANDLOW LUBE OIL PRESSURE SHUTDOWNS.
Condition: Unknown
Due 7 August 1990
Resolved 7 August 1990
Engineering
Issued 17 October 1989
Resolved
REPAIR LEAKS ON AUXILLARY HEATING BOILER AND SATISFACTORY TEST SAFETY VALVE.
Condition: Unknown
Due 17 October 1989
Resolved 17 October 1989
Fire Fighting
Issued 3 February 1989
Resolved
LOCK VALVE AND POST SIGN AT VALVE STATING "THIS VALVE MUST REMAIN LOCKED CLOSED WHEN NOT IN USE", OR SHOW PROOF OF SPECIFIC COMMANDANT APPROVAL, OR REMOVE FIREMAIN TO SEWAGE CROSS CONNECTION.
Condition: Unknown
Due 3 February 1989
Resolved 3 February 1989
Fire Fighting
Issued 4 January 1989
Resolved
PROVIDE PROOF OF SPECIFIC COMMANDANT APPROVAL FOR CROSSOVER FROM FIRE MAIN TO SEWAGE PIPING IAW 46 CFR 76.10-5(F) OR REMOVE THE CROSSOVER.
Condition: Unknown
Due 4 January 1989
Resolved 4 January 1989
Construction/Loadline
Issued 13 December 1988
Resolved
MAKE PERMANENT REPAIRS TO PIPING IN WAY OF 13DEC88 TEMP REPAIR TO SEWAGE PUMP CROSS OVER FROM FIRE MAIN. PERMANENT REPAIR MUST BE ACCORDANCE WITH USCG APPROVED WELD PROCEDURE. PERMANENT REPAIR MUST BE COMPLETED PRIOR TO COMPLIANCE DATE TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Lifesaving
Issued 14 December 1987
Resolved
CONDUCT FIRE AND BOAT DRILL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO 14FEB88.
Condition: Unknown
Due 14 December 1987
Resolved 14 December 1987
Electrical
Issued 19 October 1987
Resolved
PROVIDE AND INSTALL PROPER COVER AND GUARD TO OVERHEAD LIGHT ON PORT SIDE CAR DECK ON NUMBER 2 END. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR AND IN NO CASE LATER THAN 27OCT87.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Electrical
Issued 19 October 1987
Resolved
PROVIDE AND INSTALL PROPER COVER AND GUARD TO OVERHEAD LIGHT IN PURSERS OFFICE. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR AND IN NO CASE LATER THAN 27OCT87.
Condition: Unknown
Due 19 October 1987
Resolved 19 October 1987
Fire Fighting
Issued 25 August 1987
Resolved
EFFECT REPAIRS TO FSD NO. 4 TO ENSURE PROPER CLOSING.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 15 May 1987
Resolved
PROVIDE CURRENT STATION BILL TO SHOW INSTALLATION OF RESCUE BOATS AND ADDITION OF LIFERAFTS, PERMANENTLY MOUNTED.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Construction/Loadline
Issued 8 April 1987
Resolved
PROVE THE FOLLOWING NEW INSTALLATIONS AND DECK INSERTS: A) DECK ACCESS CUT INTO BOTH SHAFT ALLEYS (02). B) ALL NEWLY INSTALLED SCUTTLES FOR VOIDS AND STEERING FLATS (10). C) INSERTS (02) TO MAIN DECK AT PORT ENTRYWAY TO ENGINE ROOM.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Engineering
Issued 8 April 1987
Resolved
CLEAN EXCESS OIL FROM BILGES IN ENGINE ROOMS.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Engineering
Issued 8 April 1987
Resolved
INSTALL PROPER SIZE STRAINERS ON BILGE SUCTIONS IN ALL VOIDS WHERE ABSENT.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Construction/Loadline
Issued 8 April 1987
Resolved
CAP THE OPEN STUFFING TUBE ON MIDSHIP BULKHEAD INSIDE PORT ENTRY TO #1 END SHAFT ALLEY.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Accommodation/Occupational Safety
Issued 8 April 1987
Resolved
RE-LAG STEAM PIPE AT LADDER TO #2 END SHAFT ALLEY INSIDE STARBOARD ENTRY.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Accommodation/Occupational Safety
Issued 8 April 1987
Resolved
RE-BOLT TWO PIPE HANGARS FOR OVERHEAD PIPING IN #2 END SHAFT ALLEY.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Lifesaving
Issued 27 January 1987
Resolved
CONDUCT EMERGENCY DRILLS WITH FULL CREW COMPLIMENT.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Navigation
Issued 27 January 1987
Resolved
PROVIDE CURRENT DEVIATION TABLE ON COMPLETION OF REPAIRS TO NO. 1 AND NO.2 END WHEELHOUSES.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Electrical
Issued 27 January 1987
Resolved
PROPERLY DEAD-END OR REMOVE ELECTRICAL CABLE THAT LED TO GALLEY DISHWASHER AND MAKE CURRENT THE CIRCUIT BREAKER AND LABELS TO PANEL BOX ADJACENT TO GALLEY.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Fire Fighting
Issued 27 August 1986
Resolved
PROVIDE TWO (O2) EXPLOSION PROOF 3 CELL FLASHLIGHTS FOR EMERGENCY GEAR IN ACCORDANCE WITH 46 CFR 77.35.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Lifesaving
Issued 27 August 1986
Resolved
PROVIDE WEARING INSTRUCTIONS FOR "HORSE COLLAR" TYPE LIFE SAVERS AT BOTH ENDS OF THE PASSENGER DECK.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Engineering
Issued 27 August 1986
Resolved
PROPERLY MARK THE EMERGENCY FUEL SHUT OFF VALVES AS SPECIFIED IN 46 CFR 78.47-38.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Navigation
Issued 27 August 1986
Resolved
REPLACE WASTED REFLECTOR ON SEARCH LIGHT LOCATED ATOP #2 PILOT HOUSE.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Lifesaving
Issued 28 January 1986
Resolved
HAVE ANNUAL SERVICING OF BOUYANT INFLATABLE RESCUE PLATFORMS PERFORMED.
Condition: Unknown
Due 28 January 1986
Resolved 28 January 1986
Unknown
Issued 3 May 1985
Resolved
PROVIDE, MOUNT, AND STENCIL A FIRE CONTROL PLAN ON THE EXTERIOR OF THE VESSEL.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Unknown
Issued 3 May 1985
Resolved
PROVIDE RUBBER GLOVES FOR BOTH FIREMEN'S OUTFITS.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Unknown
Issued 3 May 1985
Resolved
PROVIDE AN INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Lifesaving
Issued 3 May 1985
Resolved
PROVIDE 81 ADDITIONAL ADULT LIFE PRESERVERS. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 10 MAY 1985. UNTIL THIS ITEM IS CORRECTED AND CLEARED BYA COAST GUARD MARINE INSPECTOR, THE VESSEL IS RESTRICTED TO CARRIAGE OF 1062 TOTAL PERSONS.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Fire Fighting
Issued 3 May 1985
Resolved
PROVIDE AND MOUNT 2 FOG APPLICATORS BY FIRE STATIONS IN THE SERVICE AND ACCOMMODATION SPACES. THIS ITEM WAS TO HAVE BEEN CORRECTED BY 10 MAY 1985.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985