MAURY USCG vessel records
← All vessels

TILLIKUM

Built
1959
Last inspected
6 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 July 2026
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8836120
WL3377
Flag
UNITED STATES
Maury page id
psix-43660

Documentation record

Registered dimensions (L × B × D)298.0 ft × 73.0 ft × 23.8 ft
Registered tonnagegross 2,069 / net 1,407
ITC dimensions (L × B × D)298.0 ft × 73.0 ft × 23.8 ft
ITC tonnagegross 4,869 / net 2,172
BuilderPUGET SND BRIDGE&DREDG CO · SEATTLE WA, UNITED STATES · built 1959
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2069 - Regulatory (Subpart C or D), Gross Ton
4869 - Convention (Subpart B), Gross Ton
1407 - Regulatory (Subpart C or D), Net Ton
2172 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 66 inspections, each with its date, unit and type; 58 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 66

6 July 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8430768
16 April 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8350668
7 April 2026 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8345042
7 April 2026 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8453486
4 February 2026 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8305979
1 January 2026 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8288999
8 December 2025 Vessel Attendance · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8271345
14 October 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8251973
25 August 2025 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8214983
17 August 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8211619
17 August 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8212965
19 July 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8189787
19 July 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8234845
9 July 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8180839
28 January 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8071221
7 August 2024 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7977082
29 April 2024 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7903204
26 February 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7877809
9 February 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7896436
31 January 2024 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7856420
26 July 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7754918
29 June 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7726700
19 April 2023 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7676293
17 February 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7639449
17 February 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7644748
26 January 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7810830
10 January 2023 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7613875
13 October 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7577063
29 August 2022 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7547586
19 August 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538427
5 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7525557
21 July 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7513079
6 July 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7498548
6 June 2022 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7473894
3 March 2022 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7402123
3 December 2021 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7363226
30 September 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7324359
9 August 2021 Re-Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7283815
13 May 2021 Deficiency Check · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7195631
11 February 2021 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7138294
3 September 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7049219
5 August 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7026710
7 July 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001795
26 May 2020 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001777
7 March 2020 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6909506
4 November 2019 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6847422
15 October 2019 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6835129
15 October 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6841237
2 August 2019 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6773565
20 June 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6720479
15 May 2019 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6686759
28 February 2019 Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6608431
18 December 2018 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6598998
19 October 2018 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6563930
7 August 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6504113
31 July 2018 MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6491695
5 June 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6434769
3 April 2018 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379140
4 January 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6332460
27 November 2017 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6315495
25 August 2017 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6256964
9 May 2017 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6138045
31 January 2017 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6080436
2 November 2016 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6034281
3 August 2016 MTSA/ISPS Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5962056
5 May 2016 Examination of Repairs · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5867126

Deficiency record · 58

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 July 2026 Resolved
All marine engineering details such as piping, valves, fittings, boilers, pressure vessels, etc., and their appurtenances installed on the vessel, shall be designed, constructed, and installed in accordance with the provisions of subchapter F (Marine Engineering) of this chapter. MI received report of a cracked fuel oil pipe on the vessel's No. 1 main propulsion diesel engine, causing active leakage. O/o shall replace the damaged pipe on the No. 1 main propulsion engine in accordance with approved marine engineering standards, test the system under working conditions, and prove satisfactory operation to the attending Marine Inspector prior to returning the engine to service. 46 CFR 70.20-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2026
Resolved 8 July 2026
Resolution: Replaced fuel oil pipe with in-kind replacement.Operational tests were satisfactory to attending MI.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 7 April 2026 Resolved
In the event of an accident to a boiler, unfired pressure vessel, or machinery tending to the render the further use of the item unsafe until repairs are made, a report shall be made by the chief engineer immediately to the OCMI. A notification was made but the wrong Ferry Quick Reference guide was utilized. When the TILLIKUM lost one of the two main engines, the vessel should have been in "take home mode only". The vessel continued with its service for at least one more stop before taking itself out of service. All WSF vessels and operators shall use the most current and approved Ferry Quick Reference Guide. 46CFR78.33-5a
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 April 2026
Resolved 7 April 2026
Resolution: Provided WSF current guide.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 January 2026 Resolved
Vessel reported a fuel leak on the crossover manifold connecting fuel banks on propulsion generator #1. Vessel is authorized to continue service with passengers IAW approved WSF matrix, USCG will attend vessel to attest to satisfactory repairs. 46CFR71.55-5(a)
Action required: 705 - Other - as specified
Due 1 January 2026
Resolved 1 January 2026
Resolution: Satisfactory repair witnessed by attending MI
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 December 2025 Resolved
Door closers removed from fire screen doors in emergency generator space. Replace closers.
Action required: 10 - Deficiency Rectified
Due 9 January 2026
Resolved 10 December 2025
Resolution: Closers replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2025 Resolved
Relief valve at the whistle tank reducing station will not reseat. Repair or renew relief valve.
Action required: 10 - Deficiency Rectified
Due 9 January 2026
Resolved 10 December 2025
Resolution: Relief valve renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2025 Resolved
Steam heating system condensate return pipe adjacent to the boiler flat has an external temperature greater than 150 degrees F.
Action required: 10 - Deficiency Rectified
Due 9 January 2026
Resolved 10 December 2025
Resolution: Piping lagged.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 October 2025 Resolved
Each passenger vessel of 500 tons gross tonnage and over must carry on each side of the vessel at least one rescue boat approved under approval series 160.156 that is equipped as specified in table 199.175 of this part. The #2 rescue boat is inoperable. Vessel shall reduce pax capacity by 50% until rescue boat is fully operational and tested.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 15 October 2025
Resolution: Inoperable rescue boat was replaced with a spare. Operational test completed. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 August 2025 Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions. Properly troubleshoot root cause of loss of propulsion and provide proof of repairs to CG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2025
Resolved 18 August 2025
Resolution: O/o provided root cause analysis report, completed repair/replacement of #1 gen voltage regulator IAW manufacturer's instructions, and successfully performeed sea trials with no further errors. Reports uploaded to Deficiency -> Documents Tab
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 July 2025 Resolved
Operating generators must provide a continuous and uninterrupted source of power for the ship's service load under normal operational conditions. Properly troubleshoot root cause of loss of propulsion and provide proof of repairs to CG.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2025
Resolved 20 July 2025
Resolution: Replaced UPS and then completed satisfactory dock trials and sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2025 Resolved
Aux steam boiler is only equipped with one low water cut off device. ASME/ANSI CSD-1 (incorporated by reference) requires two such devices. Install a second low water cut off device in accordance with all code requirements at the vessel's next yard period.
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 27 February 2025
Resolution: Received email from C/E attesting to the installation and proper function of the second low low water cut out. Email included photos.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 January 2025 Resolved
Approximately 155 gallons of combustible liquids in 5 gallon containers is being stored in the machinery space. 46 CFR Subchapter N only allows 55 gallons of combustible liquid stores to be kept in the machinery space. Relocate excess combustible liquid outside the machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 6 February 2025
Resolution: Received email from C/E with photos showing the combustible had been moved to a location outside the machinery space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2025 Resolved
Wiring to heater fan (over boiler) includes an inappropriate inline splice. Provide continuous cable connection or splice in accordance with IEEE Standard 45.
Action required: 10 - Deficiency Rectified
Due 5 February 2025
Resolved 5 February 2025
Resolution: Cable replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 January 2025 Resolved
Numerous fire doors in the machinery spaces found with manual hold backs installed. Hold backs are only allowed if they can be remotely released. Remove manual hold backs on fire doors in the engineering spaces.
Action required: 10 - Deficiency Rectified
Due 5 February 2025
Resolved 5 February 2025
Resolution: Hold backs removed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 August 2024 Resolved
Illustrations and instructions must be conspicuously displayed at each muster station; the method of donning life jackets. Life Jacket drop points on all four corners of vessel car deck missing required signage. 46CFR199.80(c)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2024
Resolved 25 September 2024
Resolution: Evidence of purchase order produced to attending MI
08 - Alarms › N/A - No Subsystem › General alarm
Issued 7 August 2024 Resolved
All general alarm bells shall be identified by red lettering at least 1/2 inch high: "GENERAL ALARM - WHEN BELL RINGS GO TO YOUR STATION." All general alarm bells on vessel car deck missing signage, signage faded and/or missing throughout vessel. 46CFR78.47-7(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2024
Resolved 25 September 2024
Resolution: Evidence of purchase order produced to attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2023 Resolved
Each auxiliary boiler must be available for examination by the marine inspector at intervals specified by Table 61.05-10. Boiler valve inspection required as per Table 46 CFR 61.05-10 has not been conducted within 5 years from the date of the last inspection. Vessel to make boiler valves available for inspection at next scheduled drydock. 46 CFR 61.05-10(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2023
Resolved 5 February 2025
Resolution: Boiler inspections and tests up to date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2022 Resolved
(a) Each self-propelled vessel, except as provided in paragraph (d) of this section, must have an electric or mechanical engine order telegraph system from the navigating bridge to the engine room. (c) On a double-ended vessel that has two navigating bridges, this system must be between the engine room and each navigation bridge. Engine order telegraph cable on number two end is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 14 October 2022
Resolution: Replaced engine order telegraph cable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2022 Resolved
The main steering gear must be of adequate strength for and capable of steering the vessel at maximum ahead service speed, which must be demonstrated to the satisfaction of the cognizant Officer in Charge Marine Inspections. At normal operating speeds the pedestal bearing oil unit is showing a high temperature alarm. Cite: 46 CFR 58.25-10(b)(1)
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2022
Resolution: Replaced pedestal bearing and conducted sea trials. All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 March 2022 Resolved
Prove the proper operation of the AMS and propulsion control systems. When attempting to prove PSTP PCS-13 the failure of the AUX 1 PLC did not leave the propulsion system unaffected. Propulsion control was lost from each pilothouse. 46 CFR 62.25-25, Code 60 c
Action required: 60 - Rectify deficiencies prior to movement
Due 8 March 2022
Resolved 8 March 2022
Resolution: Tested system. All Sat
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 March 2022 Resolved
Provide a means to acknowledge and silence the annunciator for the EOT failure in both the pilot house and the engineer's operating station. 46 CFR 62.25-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2022
Resolved 10 January 2023
Resolution: Witnessed PSTP related to EOT failure and capability to silence alarm.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 March 2022 Resolved
Separate the over-speed alarm from the other safety shutdowns,the main propulsion prime movers safeties e.g. e-stop, CO2, etc. also result in an over-speed indication. Alarms must be independent of each other. 46 CFR 62.25-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2022
Resolved 10 January 2023
Resolution: Witnessed alarm for main propulsion prime movers e-stop. Reason for deficient condition due to poorly written PSTP.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 March 2022 Resolved
Update the the vessel's PSTPs to reflect the condition found on the vessel. The majority of the procedures and the expected results did not match the condition found on the vessel as noted on the shipboard copy dated 2021-2022. Submit the revision to the USCG MSC for approval. 46 CFR 61.40-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2022
Resolved 31 January 2024
Resolution: PSTP's were updated and reflected proper procedures to test equipment. All were approved by MSC.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 3 March 2022 Resolved
Repair the fractured butt weld in way of the overhead deck transverse stiffener located in the No.2 steering gear room and above the e-steering station. 46 CFR 72.01-15\ Repair at next DDX.
Action required: 705 - Other - as specified
Due 17 March 2022
Resolved 10 January 2023
Resolution: Butt weld in #2 steering gear room repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 March 2022 Resolved
Repair the inoperable RPM indicators located in the central control station. 46 CFR 62.25-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2022
Resolved 17 March 2022
Resolution: WSF submitted video of the RPM inicator working.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 March 2022 Resolved
Prove all non-completed PSTPs. The engineering systems were not ready for inspection. 46 CFR 61.40-6, Code 701 c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 March 2022
Resolved 8 March 2022
Resolution: Tested- All Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2021 Resolved
Electrical installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions. Vessel received a ground fault on #2 generator on 9/28/21 and conducted maintenance to rectify the issue. Received same ground fault on 9/30/21.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2021
Resolved 1 October 2021
Resolution: Resolved deficiency in order to issue updated deficiency with prior to carriage of passengers code.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 February 2021 Resolved
Qualify the emergency power system. The frequency continually surges 60-69 hz, and when a load is applied the amps and voltage fluctuates for approx. 10 seconds. 46 CFR 112.05-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2021
Resolution: Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 February 2021 Resolved
Reconnect and qualify the remote operating valves serving the fire main/sprinkler isolation valve and the dirty oil tank which were found disconnected.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2021
Resolution: DEficiency corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 February 2021 Resolved
Prove the proper operation of the low lube oil alarm on the in-port generator as it was inoperable during the test. Prove the proper operation of the e-gen over-crank alarm, it worked 1 out of 4 attempts. 46 CFR 62.35-50
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2021
Resolved 3 December 2021
Resolution: Completed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 February 2021 Resolved
Prove proper operation of emergency steering from the steering gear compartment. 46 CFR 58.25-70(k)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2021
Resolution: Marine inspector witnessed proper operation.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 February 2021 Resolved
Mark all valves which may be used in an emergency in at least 1" letters identifying the system and the direction of operation. The emergency fuel shut off valves located on the main deck were not easily identifiable and were not minimally marked. 46 CFR 78.47-38 Due in 7 days.
Action required: 705 - Other - as specified
Due 19 February 2021
Resolved 3 December 2021
Resolution: During deck walk of quarterly, noted that valves were poperly marked with placards at valves.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 February 2021 Resolved
The black line on the ring buoy near the #1 rescue boat is deteriorating. Required to replace line. 46 CFR 70.28-1 46 CFR 199.70(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2021
Resolved 29 April 2021
Resolution: Crew fixed ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2021 Resolved
Update periodic safety tests, incorporating all notes taken by the crew and CG inspectors. 46 CFR 61.40-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2021
Resolved 3 December 2021
Resolution: Revised PSTP on 24FEB2021. Vessel had revision onboard during quarterly inspection.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 February 2021 Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, sop valve controls and in the CO2 cylinder storage room. The instructions did not match the labeling of the CO2 pulls. 46 CFR 76.15-10(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2021
Resolved 3 December 2021
Resolution: CO2 pull instructions have been updated.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 February 2021 Resolved
Class 3 sliding watertight door must operate in accordance with incorporated reference ASTM F1197. Door does not close completely, with an approximate 1" gap from full closure. Limit switch is inoperable. 46 CFR 170.270(c)(1)
Action required: 10 - Deficiency Rectified
Resolved 12 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2021 Resolved
As designed and noted in the periodic safety test procedures, #2 main diesel engine did not shut upon activation of the fixed fire extinguishing system. Corrected on the spot. 46 CFR 61.40-6(a)
Action required: 10 - Deficiency Rectified
Resolved 11 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 February 2021 Resolved
Boiler safety controls must control and cycle the unit in the proper manner and sequence. According to the PSTP, the boiler's pressure limit control's setting was 9 PSI but the boiler did not secure until 12 PSI. The switch setting indicated it was set at 9 PSI. 46 CFR 61.35-3 (a)(1) & (a)(8)
Action required: 10 - Deficiency Rectified
Resolved 12 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2021 Resolved
The hot water heating boiler must have at least one safety relief valve. The safety relief valve was marked for 15 PSI. The relief valve did not relieve at 15 PSI and the crew member utilized the remote hand pull to relieve the pressure at 17 PSI. 46 CFR 53.05-2(b)
Action required: 10 - Deficiency Rectified
Resolved 12 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 11 February 2021 Resolved
Boiler sight glass missing all 4 guards. 46 CFR 71.25-50
Action required: 10 - Deficiency Rectified
Resolved 12 February 2021
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 7 July 2020 Resolved
Wasteage on vehicle deck beyond tolerance.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 July 2020
Resolved 24 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 March 2020 Resolved
In all ventilation systems, annually operated dampers or other suitable means shall be provided in accessible locations, for the shutting off the passage of air in the event of fire. The Engine room NO2 Supply fire damper is not operating properly. 46CFR72.05-50(i) 701 C Vessel requested an extension for 30 days. Granted with the requirement to wire shut the damper and not use the fan, until fixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 26 May 2020
Resolution: Crew was able to replace the cable on the engine room damper. Tested. all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 February 2019 Resolved
The lifesaving plan onboard the vessel does not accurately reflect the amount of lifejackets onboard. Update plan to reflect the change in amount and location of lifejackets. Submit plans to the Officer in Charge, Marine Inspections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 9 April 2019
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 April 2018 Resolved
Replace SOLAS Tape on 238 lifejackets to the satisfaction of USCG Marine Inspector. 46 CFR 199.70.b.3.ii
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 6 April 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 April 2018 Resolved
#1 and #2 end port car deck lifebuoy needs re-stenciling. Stencil vessel name onto lifebuoy. 46 CFR 199.70(2)
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Lifesaving › Lifebuoys › Serviceable
Issued 3 April 2018 Resolved
06 lifebuoys SOLAS tape worn. Replace SOLAS tape. 46 CFR 199.70
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 April 2018 Resolved
03 Lifebuoy grablines wasted. Replace grablines on lifebuoys. 46 CFR 199.70(3)(i)
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Fire Fighting › Fire Hoses › Condition
Issued 3 April 2018 Resolved
Fire Station #11 hose has pinhole leak. Hose cut in front of inspector. Replace hose. 46 CFR 76.10-10
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Lifesaving › Rescue Boat › Markings
Issued 3 April 2018 Resolved
SOLAS Tape worn. Replace SOLAS Tape on both rescue boats. 46 CFR 156-7(28)
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 3 April 2018
Engineering › Steam Boiler (auxiliary/waste heat) › Water Wall
Issued 25 August 2017 Resolved
Make permanent repairs to ship service boiler to include hydrostatic testing
Action required: 705 - Other - as specified
Due 5 October 2017
Resolved 31 October 2017
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 25 August 2017 Resolved
Make repairs to ventilation fan motor servicing #2 void/steering space
Action required: 705 - Other - as specified
Due 25 September 2017
Resolved 31 August 2017
Resolution: Vent fan replaced.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 9 May 2017 Resolved
Repair three fire damper closure listed below, 1. Shaft alley access Nat exhaust (#2 end) 2. EOS supply fire damper 3. EDR supply fire damper.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 11 May 2017
Resolution: Fix all three inop dampers
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 9 May 2017 Resolved
Vessel needs new FCC "communication act safety radiotelephony and bridge to bridge certificate"
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 11 May 2017
Resolution: Vessel obtained new FCC certs.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 9 May 2017 Resolved
Prove local operation of watertight of watertight doors and indication light on bridge after closure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 11 May 2017
Resolution: Tested watertight door closures locally and from bridge, all sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 May 2016 Resolved
Ensure proper operation of #2 MDE fire damper at generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 6 May 2016
Resolution: Repaired fire damper.
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 5 May 2016 Resolved
Ensure proper operation of #1 MDE shutdown via fixed CO2 deployment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 6 May 2016
Resolution: Repaired shutdown relay.
Accommodation/Occupational Safety › Ventilation › General
Issued 5 May 2016 Resolved
Ensure proper operation of vent damper shutdown in #2 passenger cabin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 6 May 2016
Resolution: Serviced shutdown switch.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 May 2016 Resolved
Ensure proper operation of #2 ens, port exit light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Replaced light.
Lifesaving › Rescue Boat › Seating
Issued 5 May 2016 Resolved
Prove proper operation of Rescue boat & davit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2016
Resolution: Operational test of rescue boat #1 & davit, all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.