Inspection history · 70
14 April 2026
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8349927
9 March 2026
Administrative Inspection · Vessel Attendance · COI Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8323281
8 May 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8130765
11 March 2024
Internal Structural Exam · Periodic Inspection · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7877493
22 May 2023
Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7693756
18 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7671018
14 February 2023
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7636594
14 April 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7430829
23 March 2021
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7161254
3 February 2021
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7141477
11 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6951275
10 April 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6937887
6 February 2020
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6905938
12 June 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6711573
9 May 2019
In-Service Inspection · Examination of Repairs · Administrative Inspection · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6680117
27 April 2018
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6400832
16 March 2017
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6097101
10 August 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5968152
9 August 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5967477
11 February 2016
Internal Structural Exam · COI Inspection · DAPI Audit · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5814154
16 April 2015
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5104107
6 March 2015
MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5078927
7 February 2014
MARPOL Annex I Examination · Annual Inspection · Administrative Inspection · Cargo Tank Internal · MARPOL Annex VI Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4804557
23 October 2013
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4739562
22 July 2013
Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4661350
26 October 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4472803
18 April 2012
MTSA Verification · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4290948
7 January 2012
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4220315
29 July 2011
In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4098685
3 November 2010
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3883759
27 October 2010
Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3878320
11 May 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3735348
8 June 2009
MARPOL Annex VI Survey · MARPOL Annex V Examination · MARPOL Annex I Examination · Periodic Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3498161
18 February 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3424188
20 October 2008
Administrative Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3348808
7 March 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3162058
30 May 2007
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2946374
14 March 2007
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2887875
15 September 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2778985
14 September 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2778391
31 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2765186
4 April 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2616104
9 March 2006
COI Inspection · MARPOL Annex V Examination · Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2599353
13 February 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2593209
25 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2567497
15 September 2005
Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2492846
10 March 2005
MTSA Verification · MARPOL Annex I Examination · MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2307118
6 December 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2254036
18 May 2004
Deficiency Check · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2070993
7 May 2004
Deficiency Check · Administrative Inspection · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2058827
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1978445
22 October 2003
Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1933666
22 September 2003
Construction Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1910465
24 June 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1825671
10 March 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1755400
5 March 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1753136
25 February 2003
MARPOL Annex I Examination · Periodic Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1739576
21 February 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1747707
6 April 2002
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1602026
1 April 2002
In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1599866
1 April 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1599948
2 March 2001
Annual Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1453856
9 October 2000
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369881
11 March 2000
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1381822
21 June 1999
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 485390
11 March 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1386467
6 March 1998
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1445329
26 March 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1400528
21 July 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 540506
8 March 1996
Hull Examination · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1444842
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 April 2026
Resolved
Vessel has sustained damage to hull, water tight integrity of the vessel is compromise. In general, compliance with the standards established by the American Bureau of Shipping, see subpart 90.35 of this subchapter, will be considered as satisfactory evidence of the structural efficiency of the vessel. However, in special cases, a detailed analysis of the entire structure or some integral part may be made by the Coast Guard to determine the structural requirements. Repairs to hull must be conducted. Vessel is allowed to transit to shipyard to conduct repairs. Vessel will not be allowed to leave shipyard until repairs are complete.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2026
Resolved 2 May 2026
Resolution: Received ABS report of completed repairs. Accepted ABS report as vessel does have load lines certificate from ABS and must maintain watertight integrity to remain in rolled. ABS have reviewed repairs and stated the damage has be rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2026
Resolved
Tankships of less than 100 gross tons and manned tank barges must meet the requirements of § 32.40-60. PAM did not have data plate.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 April 2026
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 6 April 2026
Resolved
Each cargo tank of a tank barge must have a high-level indicating device, unless the barge complies with 46 CFR 39.2009(a). The high-level indicating device must—
(1) Indicate visually the level of liquid in the cargo tank when the liquid level is within a range of 1 meter (3.28 feet) of the top of the tank.
Visual meter indicator were stuck impeding visual range of tank for cargo tanks: no. 4 stbd / no. 3 port / no. 1 port and stbd
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 April 2026
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 9 March 2026
Resolved
Each emergency shutdown station must be marked as described in § 153.955 (c), (d), and (e) with the legend “EMERGENCY SHUTDOWN STATION” so that the legend is visible from work areas in the part of the deck where the cargo containment systems are located.
Cargo pump emergency shutdown sign needs re-stenciling.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 April 2026
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 March 2024
Resolved
See Work List attached in documents dated 12MAR24 for specific details.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 May 2023
Resolved
Rails of at least 39.5 inches must be installed on deck. Both port and starboard guardrails are damaged and should be repaired at next drydock. Port side guardrail in way of the #5 void manhole includes a stanchion which is broken from the side of the ship. Make immediate temporary repairs as discussed and permanent repairs at next drydock.
Action required: 705 - Other - as specified
Resolved 1 May 2024
Resolution: Port and STBD rails have been replaced with new railing on deck.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 May 2023
Resolved
Crop and renew bent transverse stiffener on baffle located at FR 13 in Void #2P at next drydock.
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Transverse stiffener replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 May 2023
Resolved
Tripping brackets #2, 3, 4, 5 from the top of the tank on the forward bulkhead of the #4P void are bent renew these brackets as appropriate at next drydock.
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Tripping brackets replaced to return to original.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 18 April 2023
Resolved
Each immersion suit must be marked in such a way as to identify the person or vessel to which it belongs. Immersion suits were not marked. 46 CFR 199.273(d)/ 46 CFR 70(c)(3).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 25 April 2023
Resolution: Stenciled
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 18 April 2023
Resolved
Vessel must meet 46 CFR 199.170 for carriage of line throwing appliances. Vessel must have 4 charges and is presently outfitted with only one. 46 CFR 199.170.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 26 April 2023
Resolution: New line throwers bought and put onboard
03 - Water/Weathertight Conditions › N/A - No Subsystem › Overloading
Issued 14 April 2022
Resolved
Each vessel must have a stability letter issues by the Coast Guard before the vessel is placed into service, this letter sets forth conditions of operation. Current deepest draft is 23'0". As per the stability letter the maximum draft for manned operations is 19'8.25". Ensure proper draft is obtained prior to departing port. 46 CFR 35.08-1 and 46 CFR 170.120(a)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2022
Resolved 28 April 2022
Resolution: MI verified proper draft of VSL IAW valid stability letter.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 14 April 2022
Resolved
The Load Line marks when placed on a vessel shall indicate the maximum amidships draft to which such vessel can be lawfully submerged. Ensure proper loading is obtained prior to departing port. 46 CFR 42.01-10(a)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2022
Resolved 28 April 2022
Resolution: MI verified proper draft of VSL IAW valid stability letter.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 April 2020
Resolved
(issued on 19Mar2020)
The Frame or Support of each size III, IV, and V fire extinguisher required by table 46 CFR 34.50-10(a) must be welded or otherwise permanently attaached to thea bulkhead or a deck. Semi-Portable extinguisher was not secured to a permanently attached frame/support. 46 CFR 34.50-20(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2020
Resolved 10 April 2020
Resolution: semi-portable stowage corrected by adding permanent attachment fittings with quick release pins
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 10 April 2020
Resolved
(issued on 19Mar2020)
No more than 55 gallons of of combustible liquids may be stowed in any machinery space. 145 gallons were found stored in STBD machinery space. 46 CFR 147.45(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2020
Resolved 10 April 2020
Resolution: Moved 55 gallons of combustible liquid to a second machinery space for stowage, and removed excess from vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 April 2020
Resolved
(issued on 19Mar2020)
Electrical Installations on vessel must ensure protection of crew and vessel from electrical hazards. 120V ground detection inoperatble. 46 CFR 111.01-1(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2020
Resolved 17 April 2020
Resolution: Received new parts to repair and correct ground detection.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 April 2020
Resolved
(issued on 19Mar2020)
Each cargo vessel must carry liferafts with an aggragate capacity ot accomodate total number of persons onboard and stowed in postion providing for easy side to side transfer at a single open deck level. Liferaft is stowed above port side machinery space. Re-locate liferaft or install liferaft on starboard side. 46 CFR 199.261(b)(2)(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2020
Resolved 10 April 2020
Resolution: life raft stowage was corrected by relocating life raft from above the machinery space to the elevated platform on stern of barge.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 10 April 2020
Resolved
(issued on 19Mar2020)
Each hose must be marked with the MAWP and the hose burst pressure/pressure used for test must not be marked on the hose. Test pressure was found labeled on cargo transfer hose. 33 CFR 154.500(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2020
Resolved 10 April 2020
Resolution: Operator removed the test pressure stenciling from the cargo hoses and cargo manifold piping.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 April 2020
Resolved
(issued on 19Mar2020)
All lifesaving appliances and arrangements on tank vessels must be in accordance with subchapter W. Vessel's route is restricted to "Coastwise" until it is in compliance with "Oceans, Manned", in accordance with subchapter W. During this time, vessle must meet all Coastwise Manning requirements. 46 CFR 31.36-1
Action required: 705 - Other - as specified
Resolved 11 May 2020
Resolution: Lifesaving equipment was added to the vessel in accordance with subchapter 'W' which makes the vessel now in compliance to return to a "manned Oceans Route".
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 3 June 2019
Resolved
A PRESSURE GAUGE SHALL BE INSTALLED FOR EACH PUMP DISCHARGE. ONE GAUGE MISSING, THE OTHER NOT PROPERLY CALIBRATED. REPLACE WITH PROPERLY CALIBRATED GAUGES, ONE PER PUMP DISCHARGE.
Action required: 10 - Deficiency Rectified
Resolved 3 June 2019
Resolution: REPLACED WITH NEW, CALIBRATED GAUGES.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 May 2019
Resolved
The master, owner, operator, or agent of the vessel shall notify the Officer in Charge, Marine Inspection, whenever the vessel is dry docked regardless of the reason for dry docking. Barge was discovered in dry dock at Tampa ship during a yard inspection. Make proper notifications immediately to the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2019
Resolution: OPERATOR REQUESTED CG ATTENDANCE.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 16 March 2017
Resolved
Prove proper operation of #1 port cargo piping relief valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2017
Resolved 20 March 2017
Resolution: Verified proper operation of relief valve.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 8 June 2009
Resolved
Vsl not currently in full compliance with MARPOL Annex VI regulations. Vsl to prove full compiance with MARPOL Annex VI to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 8 July 2009
Resolved 27 July 2009
Resolution: Vessel Proved compliance with MARPOL Annex VI. Deficiency cleared.
Engineering › Generator (propulsion-electric) › Battery Charging Circuitry
Issued 8 June 2009
Resolved
Prove operation of both gensets to satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 15 June 2009
Resolved 9 June 2009
Resolution: Witnessed satisfactory operational test of the vessel''s generators.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 June 2009
Resolved
VESSEL DOES NOT HAVE APPROVED SHIPBOARD MARINE
POLLUTION EMERGENCY PLAN FOR NOXIOUS LIQUID SUBSTANCES (SMPEP) ONBOARD. VESSEL IS RESTRICTED FROM CARRYING NLS CARGOES LISTED ON CARGO AUTHORITY ATTACHMENT UNTIL APPROVED SMPEP IS OBTAINED.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 February 2011
Resolution: Attending MI was presented an approved SMPEP with USCG approval letter.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 March 2006
Resolved
Install battery box on # 2 Generator Start battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 4 April 2006
Resolution: Received email picture with new installation of battery box.
Engineering › Fuel Oil Service System › Hose
Issued 9 March 2006
Resolved
Replace fuel hoses on generators to J1942 specs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 4 April 2006
Resolution: Replace hoses to satisfaction of attending marine inspector.
Engineering › Lubricating Oil Service System › Tank
Issued 9 March 2006
Resolved
Install cap on blow by container on pump engine #2 before use of engine
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2006
Resolved 9 March 2006
Resolution: Installed new cap.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 9 March 2006
Resolved
Refill or replace 3 SCBA bottles to approved pressures before commercial operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2006
Resolved 9 March 2006
Resolution: Replaced 3 SCBA bottles with newly serviced units.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 9 March 2006
Resolved
Replace or service fire extinguisher as discussed before commercial operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2006
Resolved 9 March 2006
Resolution: Replaced extinguisher with a newly serviced unit.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 March 2005
Resolved
Repair damaged rails on main deck. As discussed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 March 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 10 March 2005
Resolved
Provide for proper portable (certified inspected) extingushers as needed per COI. 03 missing.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2005
Deck/Cargo › Cargo Heating › General
Issued 10 March 2005
Resolved
Provide for sat. test of vsls TFH. Prior to use of the THF for cargo ops.
Action required: 705 - Other - as specified
Resolved 11 March 2005
Construction/Loadline › Structures › Door
Issued 10 March 2005
Resolved
Repair/ Install properly the vsls paint locker doors (hinges).
Condition: Damaged By Earlier Event
Due 17 April 2005
Resolved 14 March 2005
Construction/Loadline › Structures › Ventilators
Issued 10 March 2005
Resolved
Replace missing paint locker screen vent sceeen.
Condition: Improper/Lack of Maintenance
Due 10 April 2005
Resolved 11 March 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 March 2005
Resolved
Provide for proper trash receptacle for vsls oily rags.
Due 10 April 2005
Resolved 31 March 2005
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 10 March 2005
Resolved
Make vsls DS/DB spaces "safe for entry", so USCG can inspect said spaces as required. Ref: MSO MOBILE Activity# 2254036.
Action required: 705 - Other - as specified
Resolved 11 March 2005
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 10 March 2005
Resolved
Make proper repairs to crack in #1P DB IWO Swosh Blkd IAW Swosh Bulkhead Approved Drawings /Plans From ABS.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 31 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 6 December 2004
Resolved
Make permanent modifications to wing void transverse frames to eliminate micro-cracks. Vessel is restricted to carry cargoes with a loading temperature not to exceed 165 degrees Fahrenheit until modifications are complete.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 14 September 2005
Resolution: ABS Class Report with repairs to vessel
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 18 May 2004
Resolved
Crop and renew fracture/holes in cargo tanks #3 port and starboard sides and #4 starboard with 18" X 18" insert Prior to loading cargo. LEGACY COMPONENT DESC: Cargo Tank
Condition: Unknown
Due 14 June 2004
Resolved 18 May 2004
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 18 May 2004
Resolved
Conduct NDT of welds at all transverse frames and bilge turns in wings voids #3, 4, 5 and 6 port and starboard sides. If fracture are found crop and renew with 18" X 18" insert. LEGACY COMPONENT DESC: Cargo Tank
Condition: Unknown
Due 14 June 2004
Resolved 18 May 2004
Stability › Watertight Integrity › General
Issued 18 May 2004
Resolved
Make reparis to all void space vents or replace. LEGACY COMPONENT DESC: Wing Void Vents
Condition: Improper/Lack of Maintenance
Due 14 June 2004
Resolved 18 May 2004
Construction/Loadline › Hull › Transverse Frame
Issued 18 May 2004
Resolved
Master directed to ensure #1through #6 port and starboard wing voids are entered and all transverse frames are examined at the bilge turns to ensure there are no leaks from the cargo tanks. Then you are to notify this office in writing quarterly via fax of the results.
Action required: 705 - Other - as specified
Due 18 May 2005
Resolved 6 December 2004
Resolution: Vessel will carry No. 6 oil, reducing thermal stresses on areas of concern. Added special note for marine inspector to examine these areas during annual exams until they are modified at next drydock.
Electrical › Lighting (service)
Issued 7 May 2004
Resolved
Replace light globe covers on exterior heater space structure. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Engineering › Fuel Oil Service System
Issued 7 May 2004
Resolved
Repack packing gland on fuel oil gate valve to fluid heater. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Electrical › Lighting (emergency)
Issued 7 May 2004
Resolved
Repair battle lantern (emergency lighting) in berthing space.
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 18 May 2004
Electrical › Lighting (emergency)
Issued 7 May 2004
Resolved
Install emergency lighting outside of berthing entrance.
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 7 May 2004
Resolved
Install gangway warning sign in accordance with 46 CFR 35.30-1
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Construction/Loadline › Structures
Issued 7 May 2004
Resolved
Adjust watertight doors to berthing area and replace screw in door port light. LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Documentation › Markings/Placards
Issued 7 May 2004
Resolved
Stencil/Mark emergency cargo shutdown.
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Deck/Cargo › Mooring/Anchoring
Issued 7 May 2004
Resolved
Repair hydraulic leak on forward fendering system.
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 24 May 2004
Engineering › Fuel Oil Service System
Issued 7 May 2004
Resolved
Reinstall fuel filter bowls on #1 generator. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Engineering › Diesel Engine (propulsion-electric)
Issued 7 May 2004
Resolved
Reinstall radiator guard on #2 generator.
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 7 May 2004
Resolved
Renew starter, as original, on #1 cargo pump prime mover. LEGACY COMPONENT DESC: Cargo Pump
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 7 May 2004
Resolved
Adjust/repack #2 cargo pump valve. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Fire Fighting › Combustible Materials
Issued 7 May 2004
Resolved
Remove combustibles in hot water heater room.
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Fire Fighting › Miscellaneous Items
Issued 7 May 2004
Resolved
Submit plans/design for wooden awning at berthing entrance to USCG or remove awning.
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Deck/Cargo › Ballast › SBT
Issued 7 May 2004
Resolved
Make all SBTs and aft center void available for examination to complete IOPP renewal.
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 14 May 2004
Construction/Loadline › Hull
Issued 7 May 2004
Resolved
Complete internal structural exam prior to loading cargo and prior to departing [name withheld] zone.
Action required: 705 - Other - as specified
Resolved 14 May 2004
Construction/Loadline › Structures
Issued 6 April 2002
Resolved
Noted Fractures in Cargo Tank plating at the radius turn on outboard corners of cargo Tanks in 8 locations. Fractures are in similiar locations to other fractures in the past, but none in previously repaired areas, Crop and renew Cargo tank plating In way of identified fractures. LEGACY COMPONENT DESC: Double Bottom Tank Corner radius Plating
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2002
Resolved 8 April 2002
Resolution: Repaired
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 1 April 2002
Resolved
Complete satisfactory 150% hydrostatic test of vessels cargo piping, prior to conducting cargo operations, I.A.W. 33 CFR 156.170(c)(4). LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2002
Resolved 6 April 2002
Resolution: Witnessed Hydrostatic testing of cargo piping.