Records from 1989 to 2012. Most recent: inspection, 2 October 2012.
Inspection history · 21
2 October 2012
PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4455210
20 April 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3473873
18 February 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3424188
29 November 2006
MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2816647
18 October 2005
Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 2523335
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978379
7 April 2003
Type not recorded
No type recorded · Station Philadelphia · USCG East District (CGD-E) · Activity 1769906
8 September 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 123043
5 April 2000
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1048439
13 March 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 74813
29 April 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 683302
22 February 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1130684
19 February 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 111949
10 March 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 20660
3 March 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 14341
20 May 1997
Uninspected Towing Vessel · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1100641
29 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 17985
29 August 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 136263
14 April 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 68849
8 January 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 32796
16 August 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347216
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 October 2012
Resolved
Vessel is missing current tide tables and tidal current tables.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2012
Resolution: Provided current publications.
Construction/Loadline › Structures › Manhole
Issued 2 October 2012
Resolved
Vessel needs to make sure that all watertight doors and hatches are able to be made watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2012
Resolution: Vessel hatches and watertight doors have been repaired.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 2 October 2012
Resolved
Vessel has 2 life rings that are not in serviceable condition. Vessel needs to replace the 2 life rings with serviceable ones.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2012
Resolution: Replaced life rings.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 2 October 2012
Resolved
Vessel's CO2 room does not have the proper ventilation required. Vessel needs to have means to properly ventilate the CO2 space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2012
Resolution: Ventilation installed in CO2 space.
Fire Fighting › Fire Hydrants › Condition
Issued 2 October 2012
Resolved
Port side stern fire station has a temporary patch. Vessel must repair fire station to original condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2012
Resolution: Repaired wasted section of fire hydrant.
Lifesaving
Issued 20 May 1997
Resolved
Affix NOAA registration decal to epirb unit, not the cover._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 20 May 1997
Resolved
Captain of vessel is required to hold a radio operator's permit as per 46CFR164.72.
Condition: Unknown
Due 20 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past