Records from 2016 to 2026. Most recent: inspection, 23 February 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 February 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Battery installation under bridge console has excessive connections without over-current protection and multiple dead end wires. Remove unused wires, limit connections directly to the battery, and ensure all connections have over-current protection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 15 June 2026
Resolution: Removed dead end wires, cleaned up battery connections, and added overcurrent protection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 February 2026
Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Fwd chain locker hatch missing securing device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 15 June 2026
Resolution: Added securing device.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 February 2026
Resolved
Each lifeline on a ring life buoy must be of at least 18.3 meters (60 feet) in length. Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Fit a lifeline of atleast 60 feet and attach a lanyard (3-6 feet) to the waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 25 February 2026
Resolution: Added 60' lifeline and 3' lanyard for waterlight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 February 2026
Resolved
A hatch exposed to the weather must be watertight. Laz hatch cover gasket deteriorated, replace with new gasket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 15 June 2026
Resolution: Replaced gasket.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 February 2026
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Stbd fuel tank vent pipe missing flame screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 15 June 2026
Resolution: Added flame screen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2026
Resolved
Flexible hose runs must be visible, easily accessible, protected from mechanical damage, and must not penetrate watertight decks or bulkheads. Flexible hose on MSD pump and washdown pump not protected from mechanical damage. Properly secure MSD pump and washdown pump to deck/bulkhead to prevent damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 15 June 2026
Resolution: Secured pumps to deck.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 February 2026
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Steering ram connection loose causing decrease in mavuverability.
Action required: 10 - Deficiency Rectified
Due 12 February 2026
Resolved 12 February 2026
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 10 February 2025
Resolved
An exposed hazard, such as guard or rotating machinary must be properly protected. Port MDE at front has no guard for the belt.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 7 April 2025
Resolution: Guard installed for PORT MDE belt.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 10 February 2025
Resolved
Mattresses must comply with "standard for mattress flammability (FF 4-72.16), 16 CFR 1632 Subpart A. Crew accommodation mattresses do not comply.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 7 April 2025
Resolution: Mattresses removed from vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 February 2024
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Make bulkhead in STBD Aft engine room vapor tight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2024
Resolved 8 March 2024
Resolution: STBD AFT engine room properly sealed and vapor tight.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 February 2024
Resolved
A vessel must be provided with a main steering gear that is: (1) of adequate strenght and capable of steering the vessel at all service speeds. Secure loose steering ram support post.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2024
Resolved 8 March 2024
Resolution: Steering ram support satisfactorily supported.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 February 2024
Resolved
Make void space vapor tight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2024
Resolved 8 March 2024
Resolution: Void space properly sealed and vapor tight.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 February 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation closure device for engine room on the STBD side weather deck was found wasted and unable to close. Repair/replace closure device and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 February 2024
Resolved 16 February 2024
Resolution: New ventilation cover installed and verified proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 February 2024
Resolved
A hatch exposed to the weather must be watertight. A hatch cover must have securing devices; and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Make lazarette hatch watertight; install securing devices to hatch.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 16 March 2024
Resolution: Gasket reapplied to hatch and all W/T hatches have lanyard that is attached to space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2024
Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. One of the 2 Batteries under operating station was found with exposed terminals. Provide cover for battery or cover terminals to protect from falling objects.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 4 April 2024
Resolution: covered reattached to battery boxes
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2024
Resolved
Electrical equipment exposed to the weather must be watertight. Electrical junction boxes on top of wheelhouse for AC powered overhead lights were found with exposed wires and no longer watertight. Repair/replace electrical junction boxes above wheelhouse so that there are watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 16 March 2024
Resolution: Exterior junction boxes sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical receptacle in bunkroom on aft portside bulkhead was found with a missing/broken face plate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 24 March 2024
Resolution: New cover installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2024
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Fixed gas extinguishing system electric control box was not installed to bulkhead under operating station to prevent damage to unit or disconnecting installed wires. Mount box to prevent movement.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 1 April 2024
Resolution: Device mounted to bulkhead
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 February 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Remove oil from engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 16 March 2024
Resolution: All oil has been removed from E/R bilge
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2024
Resolved
Cable and wiring requirements. Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Replace wire zip tie supports in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 16 March 2024
Resolution: Proper supports installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2024
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of §111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. No flexible cord may be used except: As allowed under Sections 400-7 and 400-8 of NFPA NEC 2002. NEC states: Flexible cords shall not be used as a substitute for the fixed wiring. MI observed extension cord being utilized to extend circuits to power deep freezer appliance. Remove extension cords from A/C receptacles. Prior to any modifications to approved fixed electrical installations vessel must submit electrical drawings to USCG and gain approval for proposed modifications.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 16 March 2024
Resolution: Extension cord removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 February 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Generator was found with a custom heat/sound dampener box, unable to verify its material use during the construction of the non-ridged box was of a non-combustible material. Provide proof that material is non-combustible and suitable for the intended use in a machinery space.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 16 March 2024
Resolution: Documentation was provided, constructed by Sound Waves Insulation; manufacture information below.
Sound Waves Insulation, Inc.
Phone (714) 556 - 2110
Fax - (714) 541 - 2633
1406 S. Ritchey, Unit D
Santa Ana, Ca. 92705
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 February 2024
Resolved
Life jackets must be stored in convenient places throughout accommodation spaces and each stowage container must be readily available. Child life jackets must be stowed in a location that is appropriately marked and separate from adult life jackets, so the child size life jackets are not mistaken for adult life jackets. Adults and child life jackets were stored together in the crew sleeping quarters. The stowage location was unmarked, and lifejackets were not readily available.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 1 April 2024
Resolution: PFD locatons marked
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 February 2024
Resolved
The owner or managing operator shall be prepared to test the steering system and make them available for inspection to determine that they are in suitable condition and fit for intended service. The steering ram was leaking excessively while the vessel was underway.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 24 March 2024
Resolution: Steering system repaired, no longer leaking
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 February 2024
Resolved
Only one pre-engineered fixed gas fire extinguishing system is allowed to be installed in each space protected by such system. The pre-engineered fixed gas fire extinguishing system installed in the engine room has a bulkhead separating the space from the freezer room. Several penetrations were present on the bulkhead separating these spaces. In the event, the fire system was activated, the extinguishing gas will enter the adjacent space through the bulkhead penetrations, which will exceed the system’s design capacity, rending the system ineffective.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 February 2024
Resolved 1 April 2024
Resolution: Penetrations sealed in E/R bulkhead
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 February 2024
Resolved
When a vessel is anchored it shall exhibit, where it can best be seen, in the fore part, an all-round white light. The all-round white light was partially obstructed, inhibiting its visibility and impacting the vessel’s ability to anchor safely should the vessel need.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 16 March 2024
Resolution: All around white light repositioned.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 15 February 2024
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: (1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Crew on duty unable to produce Marine Radio Operator Permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 16 March 2024
Resolution: FCC license provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 February 2024
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Captain did not have a medical certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 24 March 2024
Resolution: Captain provided proof of medical cert
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 February 2024
Resolved
The Certificate of Inspection (COI) must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. The current COI was not posted and readily available for observation by passengers.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 16 March 2024
Resolution: All documents posted
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 December 2023
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel and stowed so that when the vessel sinks the survival craft floats free and inflates automatically. The life raft was found to be secured to the deck by a ratchet strap and the hydrostatic release unit was found to be expired.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2023
Resolution: The vessel owner provided photos and a video showing the correct life raft securing installation and valid hydrostatic release unit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2023
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The vessel's name on the sole ring life buoy was found to be faded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2023
Resolved 14 December 2023
Resolution: The vessel owner provided a picture of the ring buoy with the vessel's name stenciled properly.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 7 June 2023
Resolved
No marine employer shall engage or employ any individual
to serve as a crewmember unless the individual passes a
chemical test for dangerous drugs for that employer.
Deckhand onboard had not taken the pre-employment drug
test, and was not on the vessel consortium roster.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 December 2023
Resolution: Operator provided DAPI crew list for the company containing deckhand's name.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 June 2023
Resolved
Except as provided in paragraph (g) of this section, a
complete application for renewal must contain the
following: Applicants seeking a national endorsement
must either hold an unexpired medical certificate or
submit a medical certificate. Master does not have the
current medical certificate endorsement onboard. Must
show proof of non-expired certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2024
Resolution: Previous MISLE Activity 7802193 mariner provided MMC
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 7 June 2023
Resolved
A marine employer whose vessel is involved in a casualty
or incident that is, or is likely to become, a serious
marine incident as defined in 46 CFR 4.03-2 of
subchapter A of this chapter shall comply with the
requirements of 46 CFR 4.06 in subchapter of this
chapter. Vessel had expired DAPI swabs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 July 2023
Resolution: Vessel Owner submitted photos showing DAPI swabs with an expiration of December 31, 2023.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 7 June 2023
Resolved
Abandon ship and man overboard drills and training shall
be logged or otherwise documented for review by the
Coast Guard upon request. Vessel has not properly logged
drills in any form for at least 2 months. Vessel must
show proof of conducting drills and needs to conduct
drills with all new members.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2024
Resolution: Previous MSILE Activity 7802193 MI observed
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 June 2023
Resolved
Firefighting drills and training shall be logged or
otherwise documented for review by the Coast Guard upon
request. Vessel has not properly logged drills in any
form for at least 2 months.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2024
Resolution: Previous MSILE Activity 7802193 MI Observed
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 June 2023
Resolved
Each EPIRB must be tested monthly, using the integrated
test circuit and output indicator, to determine tht it
is operative. The EPIRB test shall be logged or
otherwise documented.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 December 2023
Resolution: Vessel log showing monthly EPIRB tests was provided by operator.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 June 2023
Resolved
A vessel must carry one floating waterlight, unless it
is limited to daytime operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 December 2023
Resolution: A new waterlight has been fitted to the vessel's ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 November 2022
Resolved
All engines must have at least two means for stopping the engine(s) under any operating conditions. The
fuel oil shutoff required at the engine by § 182.455(b)(4) will satisfy one means of stopping the engine. Fuel shutoff valve on the aft port side tank did not close fully. Approximately 5-10% of of the valve remained open. 46CFR182.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 January 2023
Resolution: Video and picture provided, attesting to fuel valve shut down.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 November 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which
it is installed. MI observed excessive water leaking (consistent flow rate) from the port and stbd shaft bearings. 46CFR182.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 January 2023
Resolution: Shaft bearing tightened, stopping excessive leaking.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2022
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket
light. MI observed aprox 15-18 life jackets with inoperable or missing lights. 46CFR180.75(a)
Action required: 10 - Deficiency Rectified
Resolved 22 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI observed 03 missing life jackets. Per COI vessel is required to have 27 Type I life jackets. 46CFR180.71(a)
Action required: 10 - Deficiency Rectified
Resolved 22 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 October 2022
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel and stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Survival craft was discovered with a ratchet strap around the container preventing raft from floating free. Survival craft painter line was not secured to the vessel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2022
Resolved 8 October 2022
Resolution: Operator removed ratchet strap and secured painter to the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 October 2022
Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date.
EPIRB registration was expired.
47CFR80.1061(f)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 October 2022
Resolved 8 October 2022
Resolution: Operator provided picture of updated registration for EPRIB.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 13 December 2021
Resolved
Fire hazards to be minimized so far as reaonable and practicable. Mattresses must comply with US Dept. of Commerce "Standard for Mattress Flammability (FF 4-72) and not contain polyeurethane foam; or; IMO resolution A.688(17). Mattresses on vessel are of unknown foam material and have vinyl wrap. Discussed with operator, due to cost it is acceptable to USCG to phase in all 14 mattresses over the next three years.
46 CFR 177.405(g)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2024
Resolved 24 July 2024
Resolution: Vsl provided proof of acceptable mattresses.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 November 2021
Resolved
Properly arrange hydrostatic release for life raft immediate release.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 November 2021
Resolved 3 November 2021
Resolution: Corrected during inspection.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 November 2021
Resolved
Repair hatch cover seals as ID'd (accomodations emergency escape, and engine room hatches).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2021
Resolution: Witnessed satisfactory gasket closures during follow up inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 November 2021
Resolved
Replace first-aid kit with USCG approved kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2021
Resolution: New first aid kit onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 3 November 2021
Resolved
Replace reflective tape on lifejackets as ID'd.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2021
Resolution: Reflective tape replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 November 2021
Resolved
Secure and cover loose battery for generator.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2021
Resolution: Battery secured and inside plastic box with lid.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2021
Resolved
Remove unused aft auxialiary fuel tanks (port and stbd lazarette) and associated temporary fuel transfer piping system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2021
Resolution: Tanks and piping removed from lazarette.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 November 2021
Resolved
Generator windings soaked with oil. Clean and service.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2021
Resolution: Generator appeared clean during follow up, operator stated paid 400 dollars for servicing but had no receipt. Generator was run appx 10 minutes and did not observe any oil fling.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 November 2021
Resolved
Remove or terminate dead end wiring in engine room and lazarette.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2021
Resolution: Dead end cabling was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 November 2021
Resolved
Properly connect 110V wiring in 3 engine room overhead lights and bilge mounted lazarette seawater pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2021
Resolution: Engine room lights and lazarette pump connected with junction boxes.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 November 2021
Resolved
Replace broken electical outlet on forward port engine room bulkhead.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2021
Resolution: New outlet observed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 November 2019
Resolved
Demonstrate compliance with US Department of Commerce Standard for mattress flammability FF 4-72.16, 16 CFR Part 1632 Sub part A and not contain polyurethane foam or IMO resolution A.688(17 or remove/replace all mattresses on board with compliant mattresses.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 29 January 2020
Resolution: Replacement schedule been found acceptable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 November 2019
Resolved
Attach the correct length of line to the water light with a corrosion resistant clip to the line/lanyard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 13 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 November 2019
Resolved
Attach lifeline around the body of the ring life buoy.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 13 January 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2019
Resolved
Seal hole/opening in the starboard side hull of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 November 2019
Resolved 6 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2019
Resolved
Prove proper operation of the fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 November 2019
Resolved 6 November 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 September 2018
Resolved
EPRIB found zipped tied in place making hydrostatic release inoperable.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 September 2018
Resolved 4 September 2018
Resolution: Zip ties removed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 4 September 2018
Resolved
Life raft painter not connected to weak link of hydrostatic release.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 September 2018
Resolved 4 September 2018
Resolution: Painter connected to weak link of hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2018
Resolved
Floating light found not attached to lifebuoy.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 September 2018
Resolved 4 September 2018
Resolution: Floating light attached to lifebuoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 August 2018
Resolved
Install check valves in bilge lines for lazarette/below galley (sonar)/bunk/bow space pick-ups.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 4 September 2018
Resolution: Valves installed and suction from lines tested, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 August 2018
Resolved
Properly ventilate batteries in below-galley space prior to entry. Gases generated during charging of batteries in space set off carbon monoxide detection device.
Action required: 705 - Other - as specified
Resolved 6 September 2018
Resolution: Batteries changed and ventilation verified, all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 August 2018
Resolved
Provide detailed report of annual fire servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 4 September 2018
Resolution: United Fire of San Diego 2/1/18
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 August 2018
Resolved
Provide proof of preemployment testing and continuous enrollment of members on current crew list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 4 September 2018
Resolution: Provided and updated wit ASTS
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2018
Resolved
Provide evidence of elimination of dead end wires found in sonar room and engine and generator rooms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 4 September 2018
Resolution: Cables removed,
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2018
Resolved
Provide proof of proper labeling of lifejackets (correct vessel name).
Action required: 10 - Deficiency Rectified
Due 15 August 2018
Resolved 15 August 2018
Resolution: Lifejackets were labeled with the vessel's new name.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 15 August 2018
Resolved
Provide proof of FCC Marine Operator permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 6 September 2018
Resolution: Captain operating permit is valid and on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 August 2018
Resolved
Provide proof of gasket renewal on engine room & fish hold hatches.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 26 October 2018
Resolution: Vessel renewed gaskets in way of ER and Fish Hold hatches.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2018
Resolved
Rehang breaker panel in box to prevent open gaps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2018
Resolved 6 September 2018
Resolution: Properly installed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2018
Resolved
Rehang outlets in generator space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 4 September 2018
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 August 2018
Resolved
Conduct drills & underway tests.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
Resolution: Conducted satisfactory drills and underway tests.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2018
Resolved
Provide evidence of fuel oil leak in lazarette is secure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2018
Resolution: Fuel vent was repaired.
05 - Radio Communications › N/A - No Subsystem › Facilities for reception of marine safety inform.
Issued 15 August 2018
Resolved
Provide NAVTEX for 100-200 NM route. Vessel is limited to 100 nm.
Action required: 705 - Other - as specified
Resolved 19 November 2018
Resolution: Vessel does not have radio installed or inspected. Agreed to reduce COI route to not more than 100 nm.
Communications › Public Address System › Loudspeaker
Issued 13 September 2016
Resolved
Demontrate proper operation of the vessl's public address.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 1 December 2016
Resolution: Demontrated proper operation of the vessl's public address.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 13 September 2016
Resolved
Provide FCC Radio Operators Permit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 16 August 2018
Resolution: outdated deficiency cleared during new COI issued in LA/LB
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 13 September 2016
Resolved
Adjust loose belt for hydraulics
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 1 December 2016
Resolution: Adjusted loose belt for hydraulics
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 September 2016
Resolved
Post COI
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 1 December 2016
Resolution: Posted COI
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 September 2016
Resolved
Provide a method for retrieving a hapless person from the water.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 1 December 2016
Resolution: Provided a method for retrieving a hapless person from the water.