Records from 2003 to 2026. Most recent: inspection, 22 April 2026.
Inspection history · 24
22 April 2026
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8329414
23 September 2025
Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8240140
22 May 2025
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8141966
27 March 2025
Administrative Inspection · Damage Survey
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8100373
26 March 2025
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8100871
20 September 2023
Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7795700
1 March 2023
Annual Inspection · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7643565
29 August 2022
Damage Survey · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7548332
29 August 2022
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7558403
12 April 2022
DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7426822
6 October 2021
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7328419
6 April 2021
Administrative Inspection · Examination of Repairs · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7170137
3 August 2020
Administrative Inspection · Excursion Permit
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7047457
21 April 2020
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6971626
5 November 2019
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6850637
4 April 2019
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6656896
15 June 2018
Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6448259
1 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6441516
14 February 2018
Hull Examination · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6351440
16 May 2017
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6144833
15 June 2016
Damage Survey · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5913750
15 June 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5914404
4 May 2016
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5917124
23 February 2016
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5821523
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 April 2026
Resolved
Reinstall all lighting fixtures cover in the forward and aft tank rooms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 13 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2026
Resolved
Replace all flexible hose installed between bilge pipe and strainers with 46 CFR 182. 720 approved non collapsible hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 13 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 22 April 2026
Resolved
Each door, , must be capable of being opened by one person, from either side. Handles and securing devices must be permanently installed and not capable of being easily removed. Repair Port side head door. There is no hand to operate the door on the inside and the handle with shaft can be removed from the outside which could cause a person to be trapped in the head. Repair door prior to allowing use of the head.
Action required: 705 - Other - as specified
Due 22 April 2026
Resolved 13 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2025
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 Deg F, must be suitably insulated where necessary to prevent injuries. All four turbos for the main engines are missing the required insulation. Reinstall the exhaust lagging prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2025
Resolved 3 June 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 May 2025
Resolved
A pre-engineered fixed gas fire fighting system must automatically shut down all power ventilation and engines that draw intake air from within the protected space. The installed generator does not shut down when the system is activated. Due by June 5, 2025
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 3 June 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2025
Resolved
All hatches used as a means of escape must be marked on both sides in legible letters at least 2 inches high " EMERGENCY EXIT, KEEP CLEAR". The escape hatch from the below deck space needs new markings. Due by June 22, 2025.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2025
Resolved 3 June 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2025
Resolved
Remote fuel shut off stations must be marked in clearly legible letters at least 1 inch high, indicating the purpose. The remote fuel shut off valves are not labeled. Due by June 22, 2025
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2025
Resolved 3 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2023
Resolved
Fire hose(s) must have a corrosion-resistant solid stream orifice or combination nozzle. The current nozzle does not allow for water to stream out for fire protection. Repair or replace the nozzle. Old T: 46 CFR 181.15-10(d)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 24 March 2023
Resolution: Replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 March 2023
Resolved
All radiotelephones must contain integral GPS capabilities or must be connected to an electronic position-fixing device. Current radios have to GPS link. Connect all onboard VHF radios to GPS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 24 March 2023
Resolution: Interlinked radios to GPS.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 April 2022
Resolved
Replace all combustible trash can with non combustible trash can with no opening in the side or bottoms or provide proof current trash cans are non combustible
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 20 May 2022
Resolution: Vsl now has metal trash can.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 April 2022
Resolved
Update or replace chart with current ones.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 25 April 2022
Resolution: Charts have been updated
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2022
Resolved
Provide blocking and bracing to prevent batteries from shifting when the vessel pitchs and rolls.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2022
Resolved 25 April 2022
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 13 April 2022
Resolved
install guard over pull on port main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 25 April 2022
Resolution: all Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2021
Resolved
Starboard exhaust boot located in the laz was leaking. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 16 April 2021
Resolution: Hose clamps renewed to prevent leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2019
Resolved
Ensure fuel vents have flame screens. (46 CFR 182.20-35(d))
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2019
Resolved 11 April 2019
Resolution: Flame screens installed
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 2 May 2018
Resolved
Provide proper exhaust insulation around all turbo piping on both main diesel engines. Current condition lacks suitable insulation. Installation must be verified to the satisfaction of attending Coast Guard marine inspector prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2018
Resolved 16 May 2018
Resolution: Verified proper installation of exhaust insulation.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 May 2017
Resolved
Provide valid FCC radio telephony certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 18 May 2017
Resolution: Certificate issued.
Stability › Watertight Integrity › General
Issued 17 May 2017
Resolved
Provide positive action shut off valve for gray water overboard in space #3 on the stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 18 May 2017
Resolution: valve installed.
Stability › Unintentional Flooding › General
Issued 17 May 2017
Resolved
Provide cap for abandoned thru hull fitting on starboard side of Engine Room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 18 May 2017
Resolution: Cap installed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 May 2017
Resolved
Mark emergency fuel shut off valves and direction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 18 May 2017
Resolution: markings added.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 May 2017
Resolved
Prove proper operation of running indicator light for electric submersible bilge pump in space #2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 18 May 2017
Resolution: corrected.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 24 February 2016
Resolved
Install additional courses on forward handrail to have no more distance than 4" between courses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 21 March 2016
Resolution: Additional courses have been added.
Construction/Loadline › Penetrations › Pipe Flange
Issued 24 February 2016
Resolved
Provide repair proposal for old sewage and new sewage discharge ports.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 15 March 2016
Resolution: Repair proposal was received and approved, witness new valve installation.
Electrical › Electrical Distribution System (service) › Conductor
Issued 24 February 2016
Resolved
Replace bonding wire on fuel fill pipes
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 15 March 2016
Resolution: New wires were installed.