Records from 2005 to 2026. Most recent: inspection, 14 May 2026.
Documentation record
Registered dimensions (L × B × D)98.8 ft × 30.3 ft × 10.2 ft
Registered tonnagegross 89 / net 60
ITC dimensions (L × B × D)98.8 ft × 30.3 ft × 10.2 ft
ITC tonnagegross 218 / net 102
BuilderGLADDING-HEARN SHIPBLDG · SOMERSET MA, UNITED STATES · built 1996
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
218 - Convention (Subpart B), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
102 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
14 May 2026
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8353276
2 March 2026
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8318811
2 June 2025
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8152172
17 May 2024
MTSA Verification · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7903444
22 February 2024
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7883518
6 June 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7695672
26 April 2023
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7676143
7 November 2022
DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7592323
29 August 2022
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7554103
9 May 2022
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7425561
10 March 2022
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7400708
10 March 2021
Annual Inspection · MTSA Verification · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7153429
10 August 2020
Annual Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7035401
21 January 2020
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6892998
21 March 2019
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6646925
5 April 2018
Hull Examination · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6386103
21 June 2017
Annual Inspection · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6181885
17 August 2016
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5975607
21 March 2016
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5813559
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2024
Resolved
Service / replace aft life ring, provide proper markings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2024
Resolved 20 June 2024
Resolution: New life ring installed on vessel.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2023
Resolved
Repair replace hull plate in P/S fuel tank bilge, P/S fwd #2 space, removal of pitting in bilge plates.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 26 April 2023
Resolved 22 May 2023
Resolution: Hull plate replaced inkind, test hull welds, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2021
Resolved
Prove operation of starboard Eng Rm. Vent closure (over generator).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 24 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2021
Resolved
Replace ring buoy, port main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 24 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 12 May 2021
Resolved
Replace galley window.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 4 June 2021
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 12 May 2021
Resolved
Prove operation of phone in starboard jet room and in galley (bad cord).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 24 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2021
Resolved
Replair CB Panel doors (missing Latches)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 4 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2019
Resolved
Replace CO2 extuishers with properly rated extinguishers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 June 2019
Resolution: CO2 extinguishers are mislabeled as B:C-1. Confirmed with CG-ENG-4 that they are approved as B-II.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2019
Resolved
Update circuit breaker panel directory on bridge to include computer outlet circuits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 11 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 17 May 2019
Resolved
Lengthen MOB tether line to allow crewmember access to platform.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 11 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 May 2019
Resolved
Install fire stop as needed in cable ways at P/S entry trunks to engine rooms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2019
Resolved 11 June 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 17 May 2019
Resolved
Label first upper deck to capture 233 max on upper two decks IAW stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 May 2018
Resolved
Provide updated Coast Pilot and Light List.
Due 16 June 2018
Resolved 12 June 2018
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 16 May 2018
Resolved
Provide bracket for CO2 extinguisher (2nd deck aft).
Due 16 June 2018
Resolved 12 June 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 May 2018
Resolved
Provide fire servicing report and fire detection installation report/invoice.
Due 16 June 2018
Resolved 12 June 2018
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 May 2018
Resolved
Update circuit breaker directories on E/R and main distribution panels.
Due 16 June 2018
Resolved 12 June 2018
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 May 2018
Resolved
Replace missing covers on electrical boxes in hazardous locations (engine room and jet room).
Due 16 June 2018
Resolved 12 June 2018
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 16 May 2018
Resolved
Provide updated deviation table.
Due 16 June 2018
Resolved 12 June 2018
Fire Fighting › Fixed Fire Detection System › Approval
Issued 27 September 2017
Resolved
Submit a proposal to install an approved fire detection system on the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 22 April 2020
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 21 June 2017
Resolved
Provide CO2 alarm placard when visible to crew in both E/R.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 20 July 2017
Resolution: corrected
Electrical › Electrical Distribution System (service) › Busway
Issued 21 June 2017
Resolved
Provide metallic ties vice plastic on vertical cable runs.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 10 July 2017
Resolution: Corrected
Engineering › Bilge Water Management System › Manifold
Issued 21 June 2017
Resolved
Label bilge manifold valves for the location of use.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 10 July 2017
Resolution: completed
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 21 June 2017
Resolved
Provide documentation of heat detector testing.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 25 July 2017
Resolution: New Heat detectors installed and tested by 3rd party.
Stability › Watertight Integrity › General
Issued 21 June 2017
Resolved
Adjust both E/R hatches to be able to dog down and close properly.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 27 September 2017
Resolution: Corrected
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 June 2017
Resolved
Renew marking on 02 Ring buoys with vsl's name
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 10 July 2017
Resolution: completed
Documentation › Logs/Records › MIS Form
Issued 21 June 2017
Resolved
Provide documentation that the user fees are paid
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 3 July 2017
Resolution: paid