Records from 1981 to 2025. Most recent: inspection, 20 October 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 October 2025
Resolved
Where flexible nonmetallic hose is permitted for use in 46 CFR 182.720 (e) piping systems by this section, it must meet SAE J—1942(incorporated by reference; see 46 CFR 175.600) or be specifically approved by the commandant. MI found fuel
hose on port engine to not be authorized for use on fuel
systen. Replace.
46 CFR 182.720 (e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2025
Resolved 12 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 October 2025
Resolved
Machinery and equipment installed on each vessel must be 46 CFR 182.100 16 c suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a menner as to afford adequate protection from causing fire, explosion,
machinery failure, and personnel injury. MI observed
Fuel valve on Port generator to be leaking. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2025
Resolved 12 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 October 2025
Resolved
Machinery and equipment installed on each vessel must be 46 CFR 182.100 16 c
suitable for the vessel and its operation and for the
purpose intended. All machinery and equipment must be
installed and maintained in such a manner as to afford
adequate protection from causing fire, explosion,
machinery failure, and personnel injury. Mi observed
Port Generator R/W Piping to be leaking. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2025
Resolved 12 December 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2024
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not have integrated smoke detection system. Owner to install in all necessary locations.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2024
Resolution: Received proof that vessel has installed an integrated smoke detection system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2024
Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, pressure relief valves must be checked twice every 5 years. Pressure relief valves on air tanks had no proof of last inspection or replacement. Owner to replace relief valves.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2024
Resolved 30 October 2024
Resolution: Received proof that the two relief valves on the air tanks have been replaced.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 October 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol swabs kept on board found expired. Owner to replace alcohol swabs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2024
Resolved 30 October 2024
Resolution: Received proof that alcohol swaps have been replaced and onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 October 2024
Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by 181.320(b). Spanner wrench missing at fire hose station. Operator to install spanner wrenches at fire station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2024
Resolved 30 October 2024
Resolution: Received proof that spanner wrenches are installed at the fire stations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2024
Resolved
Each life jacket kept in a stowage container must be readily available. Life jacket stowage on vessel requires wooden slats be broken to access. Operator to change stowage to make life jackets readily available to passengers.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2024
Resolved 30 October 2024
Resolution: Received proof that the life jacket are stowed in an area readily available to passangers.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 August 2024
Resolved
A vessel that is exposed to salt water more than three
months in any 12 month period since the last examination
must undergo a drydock examination and an internal
structural at least once every two years. Vessel owner/
operator failed to complete drydock exam. Schedule and
complete drydock exam.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2024
Resolved 28 August 2024
Resolution: Satisfactorily completed drydock exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 August 2023
Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. STBD MDE wet exhaust system was observed to have an active leak near bolted flange connection. Diagnose leak and repair to satisfaction of the Marine Inspector.
46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2023
Resolution: New flange installed. No leaks detected
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 August 2023
Resolved
Each item of life saving equipment with an expiration date on it must be replaced if the expiration date has passed. EPIRB hydrostatic release was expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2023
Resolution: New hydro installed
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 August 2023
Resolved
The owner or managing operator shall provide satisfactory evidence of the required servicing to the marine inspector. Provide annual servicing completed by Hiller.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 September 2023
Resolution: Report provided
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 August 2023
Resolved
A hatch exposed to the weather must be watertight. Lazarette and forepeak hatches were observed to have broken/cracked gaskets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 September 2023
Resolution: New gaskets installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 August 2023
Resolved
- The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and stern of the vessel Name of vessel was worn and not visible on the STBD bow.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 September 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 August 2023
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Bulkhead penetration was observed in watertight bilge below crew storage space. Temporary repairs authorized; repairs must be made watertight to the satisfaction of the marine inspector. Permanent repairs must be competed at the next scheduled drydock in 2024.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 1 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 August 2023
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Red hand flares and waterlight batteries were expired. Replaced and operational while onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 August 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 August 2023
Resolved
A hinged watertight bulkhead door must be fitted with a 46 CFR 179.330(b) quick action closing device operable from both sides of the door and indicator lights at the operating station showing whether the door is open or closed. Closed/open indicator lights for both type I WTDs were inoperable. Replaced and operational while onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 October 2022
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessels floating marker light has unauthorized battery with spring leads. Batteries shall be of the post type. Replace battery with approved type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 1 November 2022
Resolution: Received documentary evidence of approved floating marker light.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 October 2022
Resolved
An indicator light for each door with warns when the door is open must be installed on the bridge. Indicator lights for both watertight doors were inoperable. Show proper operation of lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 25 October 2022
Resolution: Received documentary evidence of operable watertight door lights.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 October 2022
Resolved
Alcohol testing must be conducted on each individual must be conducted within 2 hours of a serious marine incident occurs. Vessel was missing alcohol test strips. Obtain approved alcohol test strips. Vessel is limited to voyages that would allow testing to be completed within 2 hours.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2022
Resolved 1 November 2022
Resolution: Received documentary evidence of approved alcohol test strips.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2020
Resolved
AIR COMPRESSOR RELIEF VALVES NEED REPLACING. DATA PLATE ON AIR RECEIVER IS NOT LEGIBLE. REPLACEMENT VALVES TO SATISFACTION OF MARINE INSPECTOR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 11 August 2020
Resolution: Vessel rep [name withheld] submitted objective evidence clearing deficiencies. Replaced compressor relief valves with new ones.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 August 2020
Resolved
EMERGENCY ESCAPE HATCH IN ENGINE ROOM NEEDS RELABELING ON BOTH SIDES.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 11 August 2020
Resolution: Vessel rep [name withheld] submitted objective evidence clearing deficiencies. Relabeled emergency escape hatch on both sides.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 July 2019
Resolved
ANCHOR LIGHT INOPERABLE. PROVE PROPER OPERATION
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 31 July 2019
Resolved
PROVIDE UPDATED OR ELECTRONIC CHARTS FOR AREA OF
OPERATION
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 July 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 July 2019
Resolved
CO2 EXTINGUISHER DOES NOT HAVE CURRENT HYDROSTATIC TEST.
PROVIDE DOCUMENTATION THAT ALL CO2 EXTINGUISHERS HAVE
BEEN HYDROTESTED
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2019
Resolved
REPLACE CRACKED AND UNSERVICEABLE LIFE RINGS
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 July 2019
Resolved
PROPERLY SECURE LOOSE WIRES OUTSIDE OF PILOT HOUSE
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 31 July 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 31 July 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 31 July 2019
Resolved
PORT GENERATOR MOUNT HAS NUMEROUS CRACKS. PROVIDE REPAIR PLAN
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 31 July 2019
Resolved
LONGITUDINAL ON TOP OF INSERT BETWEEN MAIN ENGINES IS CRACKED. PROVIDE REPAIR PLAN
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 31 July 2019
Resolved
MAKE DAVIT HOLES WATER TIGHT ON STERN OF VESSEL
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 31 July 2019
Resolved
REPLACE WASTED HYDRAULIC LINE BRACKETS IN LAZARETTE
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 31 July 2019
Resolved
REPLACE WASTED JUNCTION BOX IN LAZARETTE
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 July 2019
Resolved
REPLACE WASTED FIRE MAIN PIPING ON PORT SIDE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 31 July 2019
Resolved
REPAIR LOOSE FLUORESCENT LIGHT BALLAST OVER TABLE
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 July 2019
Resolved
REPLACE BROKEN SWITCH COVER ON BRIDGE FOR SPOTLIGHT
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 31 July 2019
Resolved
PROVIDE MISSING CHAIN FOR FIRE NOZZLE TIP
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 July 2019
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2019
Resolved
TIGHTEN LOOSE BOLTS ON PORT MAIN ENGINE MOUNTS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 July 2019
Resolved
PROVE PROPER OPERATION OF PORT NAV LIGHT
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 July 2019
Resolved
HULL INSERT BETWEEN MAIN ENGINES IS SQUARE AND OF INAPPROPRIATE SIZE. NO RELIEF CUTS OR RADIUS CORNERS. REPLACE AT NEXT DRY DOCK
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 28 July 2020
Resolution: Hull doubler removed and correct plate added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2019
Resolved
REPLACE PORT SIDE RAW WATER SUPPLY HOSE
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 4 October 2017
Resolved
No Navigation Rules onboard; vessel required to have a copy of navigation rules onboard IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 2 November 2017
Resolution: Nav rules current edition was inplace on the vessel, at time of inspection.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 October 2017
Resolved
No FCC Safety Certificate onboard; vessel required to have FCC Safety Cert. onboard IAW 47CFR80.401.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 2 November 2017
Resolution: Valid FCC certificate was inplace on the vessel at time of inspection.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 October 2017
Resolved
No MMSI number entered into radio; vessel required to have MMSI number entered into radio IAW 47CFR80.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 2 November 2017
Resolution: MMSI number was placed in vhf radio.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 3 August 2016
Resolved
The MADISON GAIL operates more than 20 nautical miles from shore carrying freight and passengers while not engaged in the offshore oil industry trade. In accordance with old Subchapter S, 46 CFR 170.255 (c), vessels with Class 1 water tight doors in subdivision bulkheads are not permitted to proceed past 20 nautical miles unless they are operating exclusively -see narative for remaining def data.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 September 2016
Resolved 24 May 2017
Resolution: Owner installed a 20 person IBA on the bow, updated lifesaving equipment, routes and conditions, and issued an amended COI.
Engineering › Steering Gear System › Pump
Issued 21 July 2016
Resolved
Leak on stbd hydraulic pump. Repair as needed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: leaking line was replaced with approved hose.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 21 July 2016
Resolved
Replace throttle control wiring on port battery connection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Throttle control wire was repaired.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 July 2016
Resolved
Floating water light must have a lanyard of at least 3 but not more than 6 feet.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Proper water light lanyard attached.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 July 2016
Resolved
Life ring buoy needs relabeling and replace retro tape.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Relabeled and new retro tape on life rings.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 July 2016
Resolved
Floating water lights for life float needs to be extended to at least 18 feet.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Line replaced with 18 feet.
Lifesaving › Lifefloat › Lifeline
Issued 21 July 2016
Resolved
Individually attach each life float with sufficient line long enough so that each can float without contacting any other life float.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Sufficient line provided on life floats.
Engineering › Compressed Air System (control) › Hose
Issued 21 July 2016
Resolved
Replace air conditioner wiring hose in laz with acceptable tubing/pipe.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Air conditioner line replaced with proper tubing.
Communications › Alarms/Indicators › High Water Alarm
Issued 21 July 2016
Resolved
Make bilge high level alarm and indication light operable for space below crew seating.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: High water alarm was working.
Electrical › Electric Generation Source (service) › Panelboard
Issued 21 July 2016
Resolved
Make indicator light for generator and shore power on distribution panel operable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Lights on generator panel working.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 July 2016
Resolved
Make emergency light in crew accommodation space operable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Light operational.
Fire Fighting › Fire Hoses › Connections
Issued 21 July 2016
Resolved
Replace/repair both fire hose nozzles.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Both nozzles were repaired and tested.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 21 July 2016
Resolved
Post emergency and radio instructions at operating station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Instructions posted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 July 2016
Resolved
Post original COI and stability letter in specified locations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: COI and stability letter posted.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 21 July 2016
Resolved
Properly label emergency fuel shutoff's.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Fuel valves labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2016
Resolved
Remove all wire nuts and dead ended wires from port generator.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Wire nuts and dead end wires removed.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 21 July 2016
Resolved
Provide suitable safety chain at pilot house doors and deck railing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Safety chain attached.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2016
Resolved
Update all expired items in first-aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 14 November 2016
Resolution: Provided valid first aid kit.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 21 July 2016
Resolved
Provide updated copy of inland navigation rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Rules of the road purchased.
Navigation › Piloting/Steering › Marine Charts
Issued 21 July 2016
Resolved
Provide updated charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Provided charts.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 July 2016
Resolved
Provide updated alcohol testing devices.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 29 July 2016
Resolution: Provided testing strips.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 July 2016
Resolved
Provide supervisory training for master and crew members.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 14 November 2016
Resolution: Provided proof of completion of required supervisory training.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 21 July 2016
Resolved
Provide roster sheet with expiration for all crew enrolled in drug and alcohol program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 14 November 2016
Resolution: Provided proof of crew member enrollment in a drug and alcohol program.
Engineering › Steering Gear System › Rudder
Issued 21 July 2016
Resolved
Determine why port rudder is scrapping on the hull.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 29 July 2016
Resolution: Rudders were repaired and not rubbing bottom of hull.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 July 2016
Resolved
Nonconducting mats or grating must be provided on deck in front of switchboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Mat provided in front of switch board.
Fire Fighting › Fire Main › Pressure
Issued 21 July 2016
Resolved
Fire pump is only providing 45 psi. Clean sea strainer and piping at dry dock and retest.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 29 July 2016
Resolution: Fire pump checks satisfactory.
Construction/Loadline › Penetrations › Bottom Plug
Issued 21 July 2016
Resolved
Remove and plug the 2 pvc pipes going overboard under passenger seating area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: 2 PVC pipes were removed and plugged.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2016
Resolved
Remove dead ended cable in space below galley.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: Dead end wire removed.
Communications › Public Address System › Loudspeaker
Issued 21 July 2016
Resolved
Make PA system operable throughout all accommodation spaces.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: PA system checked satisfactory.
Deck/Cargo › Ballast › Tank
Issued 21 July 2016
Resolved
The forepeak is currently being used for ballast water for rough seas and cargo for delivery to vessels offshore. The vessels stability letter states that the “Forepeak Tank is considered to be a void space and shall not be used for the carriage of ballast water or other liquids”. As no liquid is authorized in the forepeak, the vessel must either have a new stability letter issued allowing the
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 29 July 2016
Resolution: All piping removed for any transfer of ballast water. Piping removed was placed back on bilge manifold with check valve. System tested satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 January 2016
Resolved
Flooding occured in engine due to a fractured port side overboard discharge from heat exchanger.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 16 February 2016
Resolution: Examined engine room where flooding occured and tested all equipment along with power trials. All satisfactory.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 July 2015
Resolved
Expired med kit supplies, IAW 46CFR184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Med kit expired items replaced.
Engineering › Steering Gear System › Power Unit
Issued 24 July 2015
Resolved
Steering gear in laz has loose gear and hardware, IAW 46CFR182.600
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Steering gear hardware and lines were repaired and inspected.
Communications › Internal Communications System › Voice Tube
Issued 24 July 2015
Resolved
PA system not working in required spaces. IAW 46CFR184.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: PA system was repaired and tested.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 July 2015
Resolved
Add nuts and lock washers to battery post in engine room. IAW 46CFR183.350
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: All battery cable post hold downs were tightened, added lock washers.
Electrical › Lighting (service) › Outlet Box
Issued 24 July 2015
Resolved
Electrical box on overhead near pilot house needs repaired. IAW 46CFR183.340
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: New junction box added and sealed.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 July 2015
Resolved
Light in engine room needs repaired and mark all emergency lighting. IAW 46CFR183.432
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 10 August 2015
Resolution: Light and wires were removed.
Construction/Loadline › Hull › Hull Plating
Issued 27 July 2012
Resolved
Wasted aluminum in vicinity of engine room vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2012
Resolved 31 July 2012
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 4 August 2009
Resolved
Make air receivers ready for internal inspection per 46 CFR 54.01-5.
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: Completed satisfactory internal inspection of both air receivers.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 August 2009
Resolved
Make emergency instructions specific to vessel per 46 CFR 185.25-1.
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: Emergency instructions are specific to vessel''s operations and equipment.
Engineering › Compressed Air System (start air) › Valve
Issued 4 August 2009
Resolved
Prove pressure relief valve on stbd air receiver as per 46 CFR 54.15-10(g).
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: Pressure relief valve on stbd air receiver relieved properly at 151 psi; set at 150 psi.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 August 2009
Resolved
Provide and install proper batteries for all electric waterlights per 46 CFR 161.010.
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: Batteries in the electric waterlights are of a type approved for use in those waterlights.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 4 August 2009
Resolved
Prove proper operation of SSB radio per 46 CFR 184.502.
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: SSB radio operates properly and was satisfactorily tested.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 August 2009
Resolved
Replace deteriorated line on ring buoy light per 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: Line attaching light to ring buoy was replaced.
Engineering › Bilge Water Management System › Pump
Issued 4 August 2009
Resolved
Prove proper operation of the primary bilge pump attached to the stbd main engine per 46 CFR 182.500.
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: Bilge pump operates properly and is self-priming.
Lifesaving › Lifefloat › Lifeline
Issued 4 August 2009
Resolved
Replace deteriorated grab line and line attaching netting on 15-person lifefloat per 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: 15-person lifefloat was replaced in kind.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 4 August 2009
Resolved
Provide and install locking device for stove doors per 46 CFR 184.220(a).
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: Proper locking device was installed on stove door.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 August 2009
Resolved
Provide and install a drip-proof electrical connection for cooking appliances per 46 CFR 184.220(f).
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: A drip-proof electrical connection for cooking appliances was installed.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 4 August 2009
Resolved
Properly mount A/C pump filters located in lazarette per 46 CFR 182.01-5.
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 6 August 2009
Resolution: A/C pump filters are properly secured in place with U-bolts.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 November 2007
Resolved
Make the watertight bulkhead between the bilge of the crew's quarters and the mid-body compartment watertight as per 46 CFR 179.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Made the watertight bulkhead between the bilge of the crew''s quarters and the mid-body compartment watertight as per 46 CFR 179.
Construction/Loadline › Structures › Door
Issued 13 November 2007
Resolved
Provide and install the proper rubber gasket in all watertight doors as per 46 CFR 179.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Provided and installed the proper rubber gasket in all watertight doors as per 46 CFR 179.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 13 November 2007
Resolved
Properly stow all loose gear in the crew's berthing as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Properly stowed all loose gear in the crew''s berthing as per 46 CFR 176.800.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 November 2007
Resolved
Provide and install guards over rotating machinery on both port and starboard main engines as per 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Provided and installed guards over rotating machinery on both port and starboard main engines as per 46 CFR 177.960.
Engineering › Fuel Oil Service System › Valve
Issued 13 November 2007
Resolved
Prove proper operation of both emergency fuel shut-offs as per 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Proved proper operation of both emergency fuel shut-offs as per 46 CFR 182.455.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 November 2007
Resolved
Make repairs to the exhaust piping on both main engines to stop exhaust leaks as per 46 CFR 182.430.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Made repairs to the exhaust piping on both main engines to stop exhaust leaks as per 46 CFR 182.430.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 13 November 2007
Resolved
Provide a repair proposal for repairs to both main engines to secure the excessive lube oil leaks as per 46 CFR 182.220.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Provided a repair proposal for repairs and made repairs to both main engines to secure the excessive lube oil leaks as per 46 CFR 182.220.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 November 2007
Resolved
Provide a repair proposal for the chaffed electrical cable on both ship's service generators as per 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Provided a repair proposal and made repairs for the chaffed electrical cable on both ship''s service generators as per 46 CFR 183.340.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 November 2007
Resolved
Conduct maintenance on all batteries in the engine room as per 46 CFR 183.350.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Conducted maintenance on all batteries in the engine room as per 46 CFR 183.350.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 November 2007
Resolved
Clean the engine room and make space ready for inspection as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Cleaned the engine room and made space ready for inspection as per 46 CFR 176.800.
Documentation › Certificates/Documents › FCC SSL
Issued 13 November 2007
Resolved
Provide an FCC Station License and a Radiotelephony Safety Certificate as per 47 CFR 80.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Provided an FCC Station License and a Radiotelephony Safety Certificate as per 47 CFR 80.
Communications › Radio Communications › EPIRB
Issued 13 November 2007
Resolved
Provide proof of EPIRB registration as per 47 CFR 80.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 19 November 2007
Resolution: Provided proof of EPIRB registration as per 47 CFR 80.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 November 2007
Resolved
Prove operation of the Port main diesel engine as per 46 CFR 182.220.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 21 November 2007
Resolution: Proved operation of the Port main diesel engine as per 46 CFR 182.220.
Communications › Radio Communications › EPIRB
Issued 10 November 2005
Resolved
Renew hydrostatic release for EPIRB to the satisfaction of the attending marine inspector as required by 46 CFR 185.728.
Condition: Improper Installation
Due 10 December 2005
Resolved 18 November 2005
Resolution: Hydrostatic release was replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 November 2005
Resolved
Renew expired aspirin and eyewash in first aid kit to the satisfaction of the attending marine inspector as required by 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Due 10 December 2005
Resolved 18 December 2005
Resolution: Asprin and eyewash were provided.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 November 2005
Resolved
Install blank covers or additional circuit breakers in the empty spaces in the distribution panel in the lazarette space to the satisfaction of the attending marine inspector as required by 46 CFR 183.10-10(b).
Due 10 December 2005
Resolved 18 November 2005
Resolution: Installed blank covers over all empty spaces in distribution panel.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 November 2005
Resolved
Provide a directory of circuits for all circuit breakers in the electrical distribution panels located in the lazarette and engine room to the satisfaction of the attending marine inspector as required by 46 CFR 183.01-15.
Due 10 December 2005
Resolved 18 November 2005
Resolution: Directory was povided for all distribution panels.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 November 2005
Resolved
Repair or renew leaking exhaust piping for the port and starboard main engines to the satisfaction of the attending marine inspector as required by 46 CFR 182.20-20.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2005
Resolved 18 November 2005
Resolution: Piping was replaced.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 10 August 2004
Resolved
Provide first aid card for 50% of the crew.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 August 2004
Resolved
Provide bridge log.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 August 2004
Resolved
Provide lifesaving equipment log
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Provided.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 10 August 2004
Resolved
Provide proper day shapes for vessel size.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 10 August 2004
Resolved
Repair or replace the MF SSB radio or limit operations to no more than 20nm from shore.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Repaired and demonstrated.
Fire Fighting › Fire Hydrants › Material
Issued 10 August 2004
Resolved
Provide Spanner wrench for each fire station.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Provided
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 August 2004
Resolved
Provide and demonstrate emergency lighting at the engine room forward watertight door and for the main switchboard and emergency escape.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Provided and demonstrated.
Documentation › Markings/Placards › Warning Signs
Issued 10 August 2004
Resolved
Properly stencil the engine room emergency escape.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Stencilled.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 10 August 2004
Resolved
Provide passenger safety orientation.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Provided.
Lifesaving › Buoyant Apparatus › Marking
Issued 10 August 2004
Resolved
Properly stencil the vessel name on each life float paddle.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Stencilled
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 August 2004
Resolved
Provide two additional life preservers for the crew's use. Items are to be stored in the pilothouse.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Provided.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 10 August 2004
Resolved
Provided dated batteries for all life preserver lights.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Provided
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 August 2004
Resolved
Provide and install a new salt water cooling hose for the port main engine exhaust overboard.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Provided and installed.
Construction/Loadline › Structures › Air Pipe
Issued 10 August 2004
Resolved
Provide means to plug both fuel oil tank vents.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 August 2004
Resolved
Repair the lazarette bilge alarm sensor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Repaired
Electrical › Electrical Distribution System (service) › Switch
Issued 10 August 2004
Resolved
Properly label each engine room 12V disconnect switch.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Labeled.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 August 2004
Resolved
Provide non-conductive matting for the main switchboard.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Provided.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 August 2004
Resolved
Paint the draft marks a contrasting color.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: painted.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 August 2004
Resolved
Provide FCC Radio station operator's license for the master.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Provided.
Construction/Loadline › Hull › Weld
Issued 10 August 2004
Resolved
Properly repair the radar platform on the pilothouse.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Repaired
Communications › Radio Communications › EPIRB
Issued 10 August 2004
Resolved
Reposition the EPIRB or provide a means of accessing the pilohouse top.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Epirb moved to 01 level.
Fire Fighting › Fire Hoses › Condition
Issued 10 August 2004
Resolved
Properly stencil the vessel's name on each firehose.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Stencilled.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 10 August 2004
Resolved
Properly stencil the emergency fuel oil cut-off valve for each tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Corrected.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 August 2004
Resolved
Properly secure the extra fire extinguishers or remove from the vessel.
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: secured 1 and removed 1.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 August 2004
Resolved
Double hose clamp the flexible hose for the air conditioner raw water cooling pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 August 2004
Resolved
Install metallic cable restraints on the lazarette AC panel distribution cables, and install blanking devices in the panel to replace missing breaker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 11 August 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Fuse
Issued 10 August 2004
Resolved
Provide fuse holders and fuses for the pilothouse DC panel boards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2004
Resolved 12 August 2004
Resolution: Provided
Construction/Loadline › Hull
Issued 3 March 2004
Resolved
Gouge and weld crack located on stern trim tab. LEGACY COMPONENT DESC: Stern Trim Tab
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 March 2004
Resolved 8 March 2004
Resolution: Inspected satisfactory repairs to the stern trim tab.
Construction/Loadline › Hull
Issued 3 March 2004
Resolved
Gouge and weld crack located on the port rudder. LEGACY COMPONENT DESC: Port Rudder
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 March 2004
Resolved 8 March 2004
Resolution: Inspected satisfactory repairs to the port rudder.
Construction/Loadline › Hull › Side Shell
Issued 3 March 2004
Resolved
Gouge and weld crack at side shell IWO port generator exhaust.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 March 2004
Resolved 8 March 2004
Resolution: Inspected satisfactory repairs of side shell IWO port generator exhaust.
Construction/Loadline › Hull › Side Shell
Issued 3 March 2004
Resolved
Gouge and weld crack on starboard side shell aft of collision bulkhead located between frames 3 and 4.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 March 2004
Resolved 8 March 2004
Resolution: Inspected satisfactory repairs of crack on starboard side shell aft of collision bulkhead located between frames 3 and 4.
Construction/Loadline › Hull › Side Shell
Issued 3 March 2004
Resolved
Gouge and weld crack located on the bow.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 March 2004
Resolved 8 March 2004
Resolution: Inspected satisfactory repairs of crack located on the bow.
Construction/Loadline › Hull
Issued 10 January 2003
Resolved
V/W #'s 1, 3, 5 & 6 aft port corner brackets. LEGACY COMPONENT DESC: Bracket
Due 17 January 2003
Resolved 14 January 2003
Construction/Loadline › Hull
Issued 10 January 2003
Resolved
C/R #'s 2 & 4 aft port corner brackets. LEGACY COMPONENT DESC: Bracket
Due 17 January 2003
Resolved 14 January 2003
Construction/Loadline › Hull › Side Shell
Issued 10 January 2003
Resolved
V/W sideshell IWO deck at aft port corner.
Due 17 January 2003
Resolved 13 January 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 10 January 2003
Resolved
Provide report to ACTNY OCMI identifying problem, actions to correct & actions to prevent reoccurance of stbd main engine failure prior to carrying passengers. Make vessel available for sea trial with U.S. Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2003
Resolved 30 January 2003
Resolution: Sea trials conduted on new stbd engine. Original engine was deemed "unrepairable" by service personnel. Identical SV-71 Detroit Diesel installed. Conducted full power (as rated by break in manual) for approx 30 mins-no vibrations, leakage or probs.
Lifesaving › Hand Flares › Storage
Issued 6 December 2002
Resolved
Provide new box, watertight and marked (labled) for signaling defices (flares, smoke).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Documentation › Certificates/Documents
Issued 6 December 2002
Resolved
Post COI and stability letter properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Construction/Loadline › Structures › Deck Plating
Issued 6 December 2002
Resolved
C/R crack in deck on bow (port side).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Construction/Loadline › Hull › Longitudinal Frame
Issued 6 December 2002
Resolved
C/R SSL #1 & 2 on port side (rope locker).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Construction/Loadline › Hull
Issued 6 December 2002
Resolved
C/R port horizontal stem support (rope locker).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Construction/Loadline › Hull › Bracket
Issued 6 December 2002
Resolved
C/R TB (bow) #s 1-3 (rope locker tripping brackets).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Stability › Watertight Integrity
Issued 6 December 2002
Resolved
Properly stuff all wire holes with proper stuffing in aft bulkhead (void #1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 December 2002
Resolved
Renew stanchion by stbd loading area prior to using stbd side for loading.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 December 2002
Resolved
Remove labeling of child life jackets off of last row of center seats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Lifesaving › Lifejacket/PFD (General)
Issued 6 December 2002
Resolved
Place an arrow or other means for identifying the location of adult life jackets on upper deck. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 6 December 2002
Resolved
Place a "donning placard" (lifejacket) on main passenger deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 December 2002
Resolved
Main cabin distribution panel is missing breaker cover (plug), install.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 December 2002
Resolved
Repair/replace stbd side flush deck fill cover. Tripping hazard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 December 2002
Resolved
Install cover around belts on fwd end of stbd MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Engineering
Issued 6 December 2002
Resolved
Install two hose clamps on all critical systems on MDE (port/stbd) cooling hoses, etc..
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 December 2002
Resolved
Remove dead end wires or properly dead end (terminate) aft end of both engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 6 December 2002
Resolved
Repair overhead (sheathing) behind MDE, port side (hazard).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 6 December 2002
Resolved
Install non-conductive electrical matting in front of main electrical panel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 December 2002
Resolved
Replace cooling line on top outboard side of stbd MDE (patched).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 December 2002
Resolved
Replace missing light covers on three light fixtures in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 6 December 2002
Resolved
Repair leak in exhaust piping, stbd/aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 6 December 2002
Resolved
Replace light fixture in fwd head.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 6 February 2002
Resolved
Conduct a satisfactory Failure Mode Effect Analysis (FMEA), in accordance with 46 CFR 184.620 and the manufacturers specifications, in the presence of a Coast Guard Marine Inspector. See plan review ltr dtd 06Feb02, PR-020027.
Action required: 705 - Other - as specified
Resolved 17 September 2002
Resolution: Witnessed satisfactory test.
Navigation
Issued 13 September 2000
Resolved
Renew rudder bearings.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Navigation
Issued 13 September 2000
Resolved
V & weld cracks in rudders.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Engineering
Issued 13 September 2000
Resolved
Renew shaft cutlass bearings.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Engineering
Issued 13 September 2000
Resolved
Provide shaft runout readings. Both stainless shafts have been straightened twice. If over limit renew shafts.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Construction/Loadline
Issued 13 September 2000
Resolved
In A/C void, crop and renew an 18" x 18"insert at 3rd longitudinal down aftbay, approx. 12" of tripped frame, and tripped bracket.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Construction/Loadline
Issued 13 September 2000
Resolved
On starboard side forward of vent renew "Temp" plywood patch in deck with welded insert.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Unknown
Issued 13 September 2000
Resolved
Upon completion of repairs to aft rub-rail, railings and vent, repairs to be examined.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Construction/Loadline
Issued 13 September 2000
Resolved
V & Weld 3" crack in trim tab, located above and behind port shaft in forward weld.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Construction/Loadline
Issued 13 September 2000
Resolved
Crop and renew 6 of the 8 gouges, located forward on port side. Insert's to be a minimum of 18" x 18" and insert frame as discussed.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Construction/Loadline
Issued 6 July 2000
Resolved
INSTALL BILGE ALARM SYSTEM AS PER APPROVED PLANS.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Construction/Loadline
Issued 8 December 1999
Resolved
Make permanent repairs to leak in bilge/fire pump manifold.
Condition: Unknown
Due 8 December 1999
Resolved 8 December 1999
Engineering
Issued 8 December 1999
Resolved
Offload all passengers. Proceed to facility to effect permanent repairs to port shaft coupling. Vessel is not to operate until permanent repairs are made to the port shaft coupling to the satisfaction of the attending marineinspector.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Engineering
Issued 15 October 1999
Resolved
Fix/repair fuel leak starboard engine.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Electrical
Issued 15 October 1999
Resolved
Fix gauges on front of generator.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Electrical
Issued 15 October 1999
Resolved
Wrap block heater cord to engine.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Engineering
Issued 15 October 1999
Resolved
Fix/repair clutch assembly.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Electrical
Issued 15 October 1999
Resolved
Place metal wire ties in engine room every 24inch in way of machinery.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Engineering
Issued 15 October 1999
Resolved
Double clamp all vital systems in eng room.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Engineering
Issued 15 October 1999
Resolved
Engine must be operationally tested and proven satisfactory to the attending Marine Inspector before operations with passengers.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Electrical
Issued 4 October 1999
Resolved
Remove all dead end wire runs or terminate in box, throughout vessel.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Accommodation/Occupational Safety
Issued 4 October 1999
Resolved
Repair/replace life rails on stern embarkation.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Electrical
Issued 4 October 1999
Resolved
Repair shore tie connection.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Accommodation/Occupational Safety
Issued 4 October 1999
Resolved
Provide safety chains for bridge wings, port and stbd.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Construction/Loadline
Issued 4 October 1999
Resolved
Repair latch to forward bilge hatch.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Construction/Loadline
Issued 4 October 1999
Resolved
Replace wooden bilge plates with authorized material in forward bilge.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Electrical
Issued 4 October 1999
Resolved
Hard wire power supply for cell phone and water cooler fwd bilge.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Accommodation/Occupational Safety
Issued 4 October 1999
Resolved
Submit plans for added life rails port and stbd side at embarkation.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Engineering
Issued 4 October 1999
Resolved
Mount T-handle, readily accwssible.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Unknown
Issued 4 October 1999
Resolved
Make vessel available for complete re-inspection.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Electrical
Issued 4 October 1999
Resolved
Hard wire hot starts both main diesel engines.
Condition: Unknown
Due 18 October 1999
Resolved 15 October 1999
Engineering
Issued 7 July 1999
Resolved
PORT ENGINE: UPON COMPLETION OF OVERHAUL HAVE ENGINE TEST RUN TO THE SATISFACTION ON ATTENDING [name withheld] OF VSL
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Documentation
Issued 4 December 1998
Resolved
MOUNT STABILITY LETTER UNDER GLASS IN PILOTHOUSE
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Unknown
Issued 4 December 1998
Resolved
PROVE PROPER OPERATION OF PA SYSTEM THRU OUT PASSENGER CABINS
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Navigation
Issued 28 August 1998
Resolved
Make repairs to hydraulic lines leaking in Lazerette.
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Engineering
Issued 28 August 1998
Resolved
Provide insulation on starboard and port exhaust from exhaust manifold to water injection line.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Construction/Loadline
Issued 28 August 1998
Resolved
Remove 3 plastic coverings for through hull bulkhead penetrations in void space forward of engine room and replace with metal similar to bulkhead.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Electrical
Issued 28 August 1998
Resolved
Remove dead end wiring, port engine.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Electrical
Issued 28 August 1998
Resolved
Provide metal retaining supports on all wires throughout vessel, every 24 inches.
Condition: Unknown
Due 17 September 1998
Resolved 17 September 1998
Construction/Loadline
Issued 28 August 1998
Resolved
Provide proper stuffing boxes for boundary penatrations for watertight bulkheads, piping and electrical, from engine room to forward void, engine room to lazerette, and forward bulkhead on forward void.
Condition: Unknown
Due 28 August 1998
Resolved 28 August 1998
Accommodation/Occupational Safety
Issued 28 August 1998
Resolved
Remove or repair third AC compressor/condensor in Lazerette.
Condition: Unknown
Due 28 August 1998
Resolved 4 September 1998
Engineering
Issued 28 August 1998
Resolved
Replace missing cutlass bearing in starboard shaft.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Construction/Loadline
Issued 28 August 1998
Resolved
V and reweld IWO void space port side, side long. #2 down from overhead.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Construction/Loadline
Issued 28 August 1998
Resolved
Remove black oil from bilge in Lazerette.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Construction/Loadline
Issued 28 August 1998
Resolved
Remove black oil from engine room bilge.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Electrical
Issued 28 August 1998
Resolved
Provide cover for motor on starboard side of engine room, aft.
Condition: Unknown
Due 28 August 1998
Resolved 28 August 1998
Engineering
Issued 28 August 1998
Resolved
Replace missing bolts for port engine stuffing box flange, tighten loose bolts.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Accommodation/Occupational Safety
Issued 28 August 1998
Resolved
Make repairs to ladder in engine room.
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Engineering
Issued 28 August 1998
Resolved
Repair support bracket, starboard side, forward exhaust riser.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Engineering
Issued 28 August 1998
Resolved
Remove temporary repair on forward exhaust riser, port engine, and make proper repair.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Engineering
Issued 28 August 1998
Resolved
Make repairs to cracked weld in aft exhaust riser, port side.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Engineering
Issued 28 August 1998
Resolved
Repair support bracket, outboard exhaust, port engine.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Navigation
Issued 29 January 1998
Resolved
Vessel must procure all applicable notice to mariners.
Condition: Unknown
Due 15 February 1998
Resolved 23 February 1998
Engineering
Issued 29 January 1998
Resolved
Vessel must replace flame screens for fuel vents.
Condition: Unknown
Due 15 February 1998
Resolved 23 February 1998
Electrical
Issued 29 January 1998
Resolved
Vessel must procure two flashlights for the bridge and engine space.
Condition: Unknown
Due 15 February 1998
Resolved 23 February 1998
Lifesaving
Issued 29 January 1998
Resolved
Secure microwave and garbage disposal unit in kitchen.
Condition: Unknown
Due 15 February 1998
Resolved 23 February 1998
Fire Fighting
Issued 29 January 1998
Resolved
Portable fire extinguisher in galley needs servicing.
Condition: Unknown
Due 15 February 1998
Resolved 23 February 1998
Lifesaving
Issued 29 January 1998
Resolved
Vessel must procure an anchor ball day shape.
Condition: Unknown
Due 15 February 1998
Resolved 23 February 1998
Electrical
Issued 29 January 1998
Resolved
Make proper electrical connections under bridge console.
Condition: Unknown
Due 15 February 1998
Resolved 23 February 1998
Documentation
Issued 29 January 1998
Resolved
Vessel was issued an CG 835 for failing to prove it was a member of a drug testing consortium.
Condition: Unknown
Due 29 January 1998
Resolved 29 January 1998
Electrical
Issued 29 January 1998
Resolved
Vessel must procure protective guards for lights in the engine room.
Condition: Unknown
Due 15 February 1998
Resolved 23 February 1998
Engineering
Issued 3 February 1997
Resolved
PROVE PROPER OPERATION OF VESSEL THROTTLE CONTROLS DURING UNDERWAY TRIALS WITH AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Construction/Loadline
Issued 3 February 1997
Resolved
DRYDOCK VESSEL AND MAKE AVAILABLE FOR INSPECTION. VESSEL NOT TO OPERATE UNTIL REPAIRS COMPLETED TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Construction/Loadline
Issued 31 August 1996
Resolved
Replace broken window on stbd side.
Condition: Unknown
Due 9 September 1996
Resolved 10 September 1996
Engineering
Issued 6 December 1994
Resolved
PROVIDE EVIDENCE OF HYDRO TEST ON PORT/STBD STARTING AIR RECEIVERS TO USCG MIO NEW YORK.
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994
Lifesaving
Issued 6 November 1992
Resolved
PROVIDE SATISFACTORY RESCUE PLATFORM, TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 November 1992
Resolved 6 November 1992
Fire Fighting
Issued 31 August 1990
Resolved
PROVIDE SERVICING REPORT FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Navigation
Issued 31 August 1990
Resolved
PROVIDE CHARTS AND NAUTICAL PUBLICATIONS PER 46 CFR 185.20-35.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Lifesaving
Issued 31 August 1990
Resolved
PROVIDE LIFEFLOATS OR BUOYANT APPARATUS FOR 10% OF PERSONS ON CERTIFICATE OF INSPECTION PER 46 CFR 180.10-25.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Navigation
Issued 31 August 1990
Resolved
PROVE PROPER OPERATION OF RADAR MODEL RM 914C.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Accommodation/Occupational Safety
Issued 31 August 1990
Resolved
REPAIR FORCED AIR VENTILATION IN HEAD.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Accommodation/Occupational Safety
Issued 31 August 1990
Resolved
PROPERLY LABEL MEN AND WOMEN ON HEAD DOORS.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Accommodation/Occupational Safety
Issued 31 August 1990
Resolved
SECURE LADDER IN ENGINE ROOM WITH BOLTS.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Construction/Loadline
Issued 28 June 1990
Resolved
SECURING DEVICE FOR HATCH ON FOCSLE IS MISSING.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Unknown
Issued 28 June 1990
Resolved
RELIEF VALVES FOR THE PORT AND STARBOARD AIR RECEIVERS WERE NOT OPERABLE.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Construction/Loadline
Issued 21 April 1987
Resolved
REPAIR PRESSURE GAUGE ON ENGINE DRIVEN FIRE/BILGE PUMP.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Lifesaving
Issued 21 April 1987
Resolved
RE-MARK ALL LIFE RINGS WITH THE PROPER SPELLING OF THE VESSEL NAME.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Construction/Loadline
Issued 21 April 1987
Resolved
MAKE REPAIRS FOR PROPER CLOSURE TO WTD #1
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Electrical
Issued 21 April 1987
Resolved
REMOVE TYPE SO CABLE TO WATER PUMP BREAKERS AND REPLACE WITH PROPER MARINE TYPE CABLE.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Fire Fighting
Issued 21 April 1987
Resolved
STENCIL VESSEL NAME ON FIRE AXE.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Engineering
Issued 21 April 1987
Resolved
SHOW PROPER OPERATION OF TWO RELIEF VALVES ON ENGINE STARTING AIR RECIEVERS AND HYDRO TEST THE RECIEVERS.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Unknown
Issued 9 May 1986
Resolved
SECURE DECK PLATES IN ENGINE ROOM
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Accommodation/Occupational Safety
Issued 9 May 1986
Resolved
SHOW PROPER OPERATION OF STBD COMPRESSOR
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Lifesaving
Issued 9 May 1986
Resolved
PLACE VESSEL NAME ON RING BUOYS AND REPAIR GRAB LINES
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Lifesaving
Issued 9 May 1986
Resolved
REPAIR GRAB LINES ON TWO B/A
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Electrical
Issued 9 May 1986
Resolved
REMOVE LOOSE WIRE FROM ENGINEROOM AND FROM 2 COMPT. FWD OF ENGINEROOM
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Deck/Cargo
Issued 9 May 1986
Resolved
PUMP BILGE IN 2 COMPT FWD OF ENGINEROOM
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Electrical
Issued 9 May 1986
Resolved
REPLACE GLOBE IN # 3 COMPT.
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Unknown
Issued 12 March 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL INDEPENDENCE DN641076
Condition: Unknown
Due 30 March 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 12 March 1984
Resolved
REPAIR AND PROVE OPERABLE THE STARBOARD BILGE PUMP.
Condition: Unknown
Due 12 March 1984
Resolved 12 March 1984
Construction/Loadline
Issued 12 March 1984
Resolved
PROVIDE SUITABLE HAND GRABS ALONG PORT AND STARBOARD OUTER SIDES OF MAIN PASSENGER CABIN.
Condition: Unknown
Due 12 March 1984
Resolved 12 March 1984
Construction/Loadline
Issued 12 March 1984
Resolved
MARK EXIT DOORS ON MAIN PASSENGER COMPARTMENT "NO PASSENGERS ALLOWED ON EXPOSED WEATHER DECK".
Condition: Unknown
Due 12 March 1984
Resolved 12 March 1984
Construction/Loadline
Issued 12 March 1984
Resolved
OBTAIN AND MOUNT VALID FCC CERTIFICATE.
Condition: Unknown
Due 12 March 1984
Resolved 12 March 1984
Construction/Loadline
Issued 12 March 1984
Resolved
MARK ALL ESCAPE HATCHES AND EXITS ON BOTH SIDES, USING AT LEAST 1" LETTERS "ENERGENCY EXIT, KEEP CLEAR".
Condition: Unknown
Due 12 March 1984
Resolved 12 March 1984