Documentation record
Registered dimensions (L × B × D)160.0 ft × 38.0 ft × 7.8 ft
Registered tonnagegross 396 / net 396
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG B ZIGLER COMPANY · MERMENTAU, LA, UNITED STATES · built 1960
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Endorsements, as the file codes themcw_un
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it396 - Regulatory (Subpart C or D), Gross Ton
396 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 43 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 43
12 February 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3146393
21 August 2006
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2755282
3 July 2006
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2699604
29 June 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2725398
2 August 2005
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2448764
8 October 2004
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2287876
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1976217
29 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1966608
24 October 2002
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1694721
14 August 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431112
17 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068777
1 August 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821380
15 April 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 121011
29 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 816015
10 August 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 775052
4 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802023
1 August 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798064
2 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 476475
5 February 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1108151
7 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 447992
7 October 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421424
9 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121474
1 August 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774187
1 August 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396571
1 August 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357282
9 August 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460727
1 September 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354451
14 August 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410744
30 October 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1253462
19 September 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934240
2 October 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915874
2 April 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 476557
28 September 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347546
4 December 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 523038
22 September 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042981
11 July 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 481496
29 September 1987
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318110
4 June 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310666
11 June 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988018
17 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978500
7 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975177
7 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972311
24 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277320
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 October 2005
Resolved
Renew ullage hatch cover on #1 stbd cargo tank.
Action required: 705 - Other - as specified
Due 8 October 2005
Resolved 8 October 2005
Resolution: Ullage hatch renewed.
Pollution Prevention/Response › Prevention Equipment
Issued 29 October 2003
Resolved
Mechanical means of closing the STBD aft combing plug was inoperable. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Action required: 705 - Other - as specified
Resolved 18 December 2003
Resolution: Renewed the plug.
Engineering › Fuel Oil Service System › Valve
Issued 29 October 2003
Resolved
No cut off valve was installed on the prime mover fuel line on the prime mover end.
Action required: 705 - Other - as specified
Resolved 18 December 2003
Resolution: Installed proper valve in the fuel line.
Engineering › Fuel Oil Service System
Issued 29 October 2003
Resolved
Chafing gear needs to be provided on various fuel lines. Also, one fuel line on the prime mover was in disrepair. LEGACY COMPONENT DESC: Hose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2003
Resolution: Chafing gear provided as discussed, and a new fuel line was installed on the prime mover itslef.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 29 October 2003
Resolved
Draft marks were unreadable.
Action required: 705 - Other - as specified
Resolved 18 December 2003
Resolution: Draft marks were repainted.
Stability › Watertight Integrity
Issued 29 October 2003
Resolved
Butter worth hatch covers were loose and had missing and misaligned bolts. LEGACY COMPONENT DESC: Hatch Covers
Action required: 705 - Other - as specified
Resolved 18 December 2003
Resolution: All hatch covers properly secured.