MAURY USCG vessel records Sign in
← All vessels

MAUI NUI EXPLORER

MAUI NUI EXPLORER is a 1996 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 1996, most recently in August 2023, along with 51 deficiencies, 1 operational control and 2 casualty investigations between 2021 and 2023.

Records from 1996 to 2023. Most recent: inspection, 9 August 2023.

Built
1996
Last inspected
9 August 2023
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI9422
440244
Flag
UNITED STATES
367127030, 367748470 (licence lapsed)
Maury page id
psix-440244

Inspections, by type

…with no type recorded4
Years with a record 23 calendar years (1996–2023)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)43.4 ft × 10.7 ft × 3.7 ft
Registered tonnagegross 11 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN RIGID INFLATABLE BOATS INC · COSTA MESA, CA, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9422MMSI 367748470 · expired · compulsorily equipped · granted 28 July 2016, cancelled 5 September 2026
WDD3187MMSI 367127030 · expired · compulsorily equipped · granted 29 June 2006, cancelled 3 September 2016
WCW6839MMSI not assigned · expired · compulsorily equipped · granted 19 June 1996, cancelled 19 August 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SCOTCH MIST II Passenger (Inspected) · MISLE 54428 · 23 December 2020 · activity 7131921NAPALI EXPLORER III Passenger (Inspected) · MISLE 429374 · 23 December 2020 · activity 7131921

Inspection history · 44

9 August 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770031
9 August 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7775326
12 July 2023 DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7741981
3 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7679824
1 November 2022 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7587133
11 May 2022 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7448095
4 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7214055
3 February 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7135314
9 January 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7137715
23 December 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7131921
18 November 2020 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7097393
15 July 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7007839
7 August 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6807983
16 May 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6686053
13 December 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6597501
5 December 2018 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6593397
10 July 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6475067
18 May 2017 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6146963
26 April 2017 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6134818
18 May 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5934288
30 May 2012 Plan Review "T" Boat · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4357694
3 May 2012 Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4320660
19 January 2010 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3666041
14 May 2009 Deficiency Check · Annual Inspection · Hull Examination · DAPI Audit · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3475272
28 May 2008 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3220513
21 May 2008 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3212947
30 May 2007 Hull Examination · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2946540
11 July 2006 Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2709494
15 June 2005 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2391642
4 June 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2089067
2 June 2004 Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2085731
18 June 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1632729
4 June 2002 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1623885
15 June 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1069307
6 June 2001 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362259
5 June 2000 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1415388
9 June 1999 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 811131
8 June 1999 MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360969
5 June 1998 Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1452409
12 December 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 30465
17 October 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 776211
5 June 1997 MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364212
8 August 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1421186
10 June 1996 COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1441074

Deficiency record · 51

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 12 July 2023
Resolution: Completed satisfactory DAPI audit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2023 Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Missing double hose clamps on stbd MDE oil cooler hose, stbd fire pump hose, port shaft seal. 46 CFR 182.410 (d) (1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 5 May 2023
Resolution: Double hose clamps provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2023 Resolved
Battery installations must be mounted too protect against shifting of the vessel and free from exposure to water splash or spray. Batteries did not have covers and battery boxes not secured to prevent shifting. Provide suitable protection against exposure to water or spray and shifting. 46 CFR 183.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 5 May 2023
Resolution: Battery box secured and lid provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Inboard aft rubber engine mounts on both port and starboard engines cracked. Provide new engine mount rubber. 46CFR182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 24 May 2023
Resolution: New rubber engine mounts provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2022 Resolved
The name of the vessel must be marked on port and starboard bow. Vessel name on starboard side falling off. Provide vessel name on starboard side bow. 46 CFR 67.123
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 27 July 2022
Resolution: New vessel name decals installed on the port and stbd side.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 May 2022 Resolved
As appropriate for the intended voyage vessel must carry adequate and up to date charts, US Coast Pilot [name withheld], and Tide Tables. Nav publication either missing or not updated. Provide updated nav publications. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 10 June 2022
Resolution: All required publications provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2022 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located at the pull handle. Pre-engineered fire fighting system does not have instructions at pull handle. Provide instruction for fire boy pull handle at pull handle. 46 CFR 185.612
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 12 May 2022
Resolution: Signage provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner to afford protection from causing machinery failure. Block that steering ram sits on loose. make steering system tights to prevent movement. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 12 May 2022
Resolution: Steering gear tightened up.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2022 Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure. Work Instruction 31
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 14 June 2022
Resolution: Written WI-31 procedures provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 June 2021 Resolved
Navigation publications outdated. Provide current navigation publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 18 June 2021
Resolution: Nav pubs provided.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 4 June 2021 Resolved
Compass light not operational. Provide operational compass light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 15 June 2021
Resolution: New compass with light installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2021 Resolved
Marking showing number of child life jackets missing. Provide marking for number of child life jacket stowage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 18 June 2021
Resolution: Marking provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2021 Resolved
Portable Fire extinguisher brackets corroded and hard to remove extinguishers. Provide new fire extinguisher brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 10 June 2021
Resolution: New brackets installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 July 2020 Resolved
Inspect lifesaving equipment in accordance with 46 CFR 176.808. Life float cover hydrostatic release was expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2020
Resolution: New hydrostatic release installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2020 Resolved
An adult life jacket shall be provided for each person in accordance with 46 CFR 180.71. 09 adult life jackets failed inspection. Vessel limited to 36 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 August 2020
Resolution: New lifejackets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020 Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. Ring life buoy was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 4 August 2020
Resolution: New ring buoy provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 July 2020 Resolved
Inspect bulkheads in accordance with 46 CFR 176.802. Forward engine compartment bulkhead was not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 29 July 2020
Resolution: Bulkhead glassed and watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2020 Resolved
Inspect electrical wiring in accordance with 46 CFR 176.608. Unused/unsecured wire was present in engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 29 July 2020
Resolution: Dead end wire removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020 Resolved
Inspect piping in accordance with 46 CFR 176.804. Scupper drain pipe clamp in engine compartment failed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 29 July 2020
Resolution: Drain scupper clamp replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 July 2020 Resolved
Mark life jacket stowage compartments in accordance with 46 CFR 185.604. Life jacket storage location was not properly marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 29 July 2020
Resolution: Lifejacket marking provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 July 2020 Resolved
Conduct inflatable collar tests in accordance with 46 CFR 176.804.Port aft collar baffle failed. To be repaired at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 November 2020
Resolution: Wing rep came to island and made repair on baffle.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 July 2018 Resolved
02106-Testing of RHIB sponsons for structural integrity. Baffles separating 9 compartments failed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2018
Resolution: New collars installed. Test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2018 Resolved
11118-Adult PFD must be provided for each person. 6 adult PFDs failed inspection. Vessel restricted to 39 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 July 2018
Resolution: 6 adult PFDs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 July 2018 Resolved
11132-Each item of lifesaving equipment must be in serviceable condition. Lifefloat is faded and retro needs renewal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 13 December 2018
Resolution: New life floats installed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 May 2017 Resolved
COD not provided during inspection.
Condition: Invalid
Due 3 June 2017
Resolved 5 June 2017
Resolution: Provided.
Navigation › Piloting/Steering › Marine Charts
Issued 18 May 2017 Resolved
Chart not provided during inspection.
Condition: Invalid
Due 3 June 2017
Resolved 7 June 2017
Resolution: Chart provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 18 May 2017 Resolved
Provide service record for installed fire ext system.
Condition: Improper/Lack of Maintenance
Due 3 June 2017
Resolved 5 June 2017
Resolution: System serviced.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 14 May 2009 Resolved
Provide manufacturer's recommended operating PSI for pontoons.
Due 31 May 2009
Resolved 9 June 2009
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 May 2008 Resolved
Display EAP policy/statement and hotline numbers.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 9 June 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 May 2008 Resolved
Unable to do adequate first aid to the recovered person. Complete first aid training and complete drills again.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 9 June 2008
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 28 May 2008 Resolved
Complete 1 hour EAP supervisor training.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 9 June 2008
Lifesaving › Lifebuoys › Serviceable
Issued 30 May 2007 Resolved
Renew as original lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2007
Resolved 8 June 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 30 May 2007 Resolved
Renew as original damaged lifejackets; reduce passengers to 36 adults and 4 children until repaired or replaced.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 8 June 2007
Lifesaving › Buoyant Apparatus › Serviceable
Issued 30 May 2007 Resolved
Renew as original the buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2007
Resolved 8 June 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 May 2007 Resolved
Conduct underway drills with the Coast Guard.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 8 June 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 May 2007 Resolved
Prove function of the fixed firefighting override system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2007
Resolved 8 June 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 June 2004 Resolved
Provide original document to attending Marine Inspector. Vessel has copy of COI.
Condition: Unknown
Due 15 June 2004
Resolved 15 June 2005
Navigation › Piloting/Steering
Issued 4 June 2002 Resolved
Provide CG light list IAW 46CFR184.420. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Due 18 June 2002
Resolved 18 June 2002
Navigation
Issued 6 June 2001 Resolved
PROVIDE CURRENT CG LIGHT LIST IAW 46CFR184.420 NLT 20JUN01.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Lifesaving
Issued 6 June 2001 Resolved
PROVIDE LIFE RING BUOY THAT IS ORANGE AND APPROVED IAW 46CFR180.70 NLT 20JUN01.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Accommodation/Occupational Safety
Issued 6 June 2001 Resolved
UPDATE FIRST AID KIT TO COMPLY WITH 46CFR184.420 NLT 20JUN01.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Lifesaving
Issued 6 June 2001 Resolved
PROVIDE PROOF OF CURRENT EPIRB REGISTRATION WITH NOAA NLT 20JUN01.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Lifesaving
Issued 6 June 2001 Resolved
BATTERY EXPIRED ON EPIRB. PROVIDE EPIRB THAT COMPLIES WITH 46CFR185.728(b) AND 180.64 NLT 20JUN01. VESSEL IS RESTRICTED FROM OPERATING OUTSIDE OF 3 MILES FROM SHORE UNTIL CORRECTED.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Fire Fighting
Issued 6 June 2001 Resolved
PROVIDE ONE B-I FIRE EXTINGUISHER AND MOUNT PRIOR TO CARRYING PASSENGERS IAW 46CFR181.500 NLT 20JUN01._x001C_
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Construction/Loadline
Issued 8 June 1999 Resolved
Renew dogs for watertight hatch covers as necessary.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Fire Fighting
Issued 8 June 1999 Resolved
Provide means to close all supply and exhaust ducts IAW 46 CFR 182.465(h).
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Unknown
Issued 10 June 1996 Resolved
PROVIDE AND MAINTAIN A LOG FOR REQUIRED FIRE FIGHTING DRILLS AND TRAINING AS PER IFR 185.524.
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Construction/Loadline
Issued 10 June 1996 Resolved
INSTALL SECURING DEVICES FOR EACH HATCH COVER ATTACHED TO THE FRAME OR COAMING BY HINGES, CAPTIVE CHAINS, OR OTHER DEVICES TO PREVENT THEIR LOSS.
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Unknown
Issued 10 June 1996 Resolved
PROVIDE AND MAINTAIN A LOG FOR REQUIRED ABANDON SHIP AND MAN OVERBOARD DRILLS AND TRAINING AS PER IFR 185.520.
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Engineering
Issued 10 June 1996 Resolved
INSTALL FLAME SHIELD BOWLS FOR ALL RACOR FILTER ASSEMBLIES.
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Unknown
Issued 10 June 1996 Resolved
PROVIDE WEEKLY, MONTHLY, AND ANNUAL MAINTENANCE AND INSPECTION PROCEDURES FOR VESSEL'S PRIMARY LIFESAVING EQUIPMENT AS PER IFR 185.720,722 & 726.
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996

Casualty record · 2

9 January 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7137715
9 August 2023Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7775326
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.