Records from 1996 to 2014. Most recent: inspection, 21 August 2014.
Inspection history · 30
21 August 2014
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4955921
12 February 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3676220
12 February 2010
COE-Offshore · ISPS I Exam · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3679076
10 November 2008
PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3360479
6 November 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3360486
13 May 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3196824
16 October 2007
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3081095
15 October 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3080645
15 October 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3080925
11 October 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3077792
21 September 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2783599
17 October 2005
MARPOL Annex V Examination · ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2515399
12 June 2004
Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2091535
24 April 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2052010
9 November 2003
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1941833
25 April 2003
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1777047
27 December 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1724720
17 January 2002
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1476180
24 May 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 290547
13 January 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 285854
11 March 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 275544
26 July 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 431092
1 April 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 427164
27 June 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 417177
27 June 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 462783
21 July 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 405912
28 March 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 401512
3 June 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 645616
3 June 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 718417
28 May 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 391396
Fire Fighting › Structural - A Class Divisions › Doors
Issued 21 August 2014
Resolved
0750 - Fire Prevention - The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. The opening located on "B" deck leading to the pipe and duct room is fitted with a B-0 door. The fire control plan has this space listed as an "A" boundary. SOLAS 74 (97) II-2/47.1
Action required: 705 - Other - as specified
Due 20 September 2014
Resolved 24 January 2015
Resolution: The fire resistant door leading into the pipe and duct room located on the "B" deck, was corrected and is listed as a "B" boundary on the fire control plan.
Fire Fighting › Portable Foam Applicators › General
Issued 21 August 2014
Resolved
0730- Appliances (General Equipment) - Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. Excess paint in paint locker prevented immediate use of fire extinguisher. Crew reorganized the paint and made a clear path to the fire extinguisher. SOLAS 74 (97) II-2/21
Action required: 705 - Other - as specified
Resolved 21 August 2014
Resolution: Crew reorganized the paint and made a clear path to fire extinguisher
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 13 May 2008
Resolved
0610/0680-Starboard lifeboat: 1)Embarkation ladder wasted at the deck connection 2)Limit switch fell off in hands of inspector 3)Inside and outside becket lines fwd are broken, tied together and inboard connection for the line has been patched 4)Gear box leaking oil 5)Fwd/Aft wooden shoes are wasted and forward support for the shoes has cracks in it. To be addressed by Class. ISM A/10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Items was corrected under the supervision of the Classification Society Representative.
Lifesaving › Lifebuoys › Immediately Available
Issued 13 May 2008
Resolved
0650-Lifebuoy: 1)Bridge-wing life buoys will not self deploy when the pin is pulled because hey are too big 2)Poop deck port side lifebuoy is being held in place with tape 3)Aft of port and stbd lifeboat, lifebuoy is missing reflective tape and paint color missing. To the satisfaction of Class. ISM A/9. ISM A/10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Items was corrected under the supervision of the Classification Society Representative.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 13 May 2008
Resolved
0710-Fire Prevention: 1)Hatch in front of the funnel leading to Eng room is not bolted down. 2)hatch leading to Eng room, stbd side is not secured 3)Wires running through A-0 boundary of the air cond room & ECR with no packing material 4)Spare state room has been converted into store room, no indication on fire plan 5)Galley doors (A-0) were tied open 6)Air vents aft of house will not close.
Action required: 705 - Other - as specified
Resolved 16 May 2008
Resolution: Items were corrected under the supervision of the Classification Society Representative. One item the Bulkhead aft of the A/C room will be repaired at the next dry-dock in May 1009.
Operations/Management › Pollution › Control of Garbage
Issued 13 May 2008
Resolved
2120-Garbage: 1)Two GMPs on board 2)No one in crew new C/Eng was in charge of garbage (as stated in GMP) 3)Mixed garbage found throughout including final collection point 4)Pipe duct and water closet being used as overflow garbage storage 5)Receptacle types and locations are not as listed in GMP 6)No special container is being used for hazardous waste as required in GMP. ISM A/2
Action required: 705 - Other - as specified
Resolved 16 May 2008
Resolution: Items was corrected under the supervision of the Classification Society Representative.
Documentation › Logs/Records › Oil Record Book
Issued 13 May 2008
Resolved
1210-Oil Record Book: C/Eng has not been maintaining the Oil Record Book in accordance with the MARPOL Regs. He is still using the old codes that changed in the 2006 MARPOL. Weekly entries are not current and bunkering are not being used. To the satisfaction of Class. ISM A/2. ISM A/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Items was corrected under the supervision of the Classification Society Representative.
Operations/Management › Log/Records › Ballast Water Logs/Records
Issued 13 May 2008
Resolved
2535-Ballast Water Management Plan: Records of training and sediment documentation is not being recorded as per the plan. The plan is missing a diagram for sample points and an approved Ballast Water Handling Log form. The C/Officer has a form but it has not been incorporated into the plan. To the satisfaction of Class. ISM A/2. ISM A/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Items was corrected under the supervision of the Classification Society Representative.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 13 May 2008
Resolved
1705-Shipboard Oil Pollution Emergency Plan: The crew has only been conduction bunkering drills. As per the SOPEP and NT-VRP additional drills such as fire/explosion, grounding, collision and others should be conducted. Reference SOPEP Sec 3 and NT-VRP Ch.6. In addition, there is no updated list of local contact numbers in the SOPEP as required by Sec.2.2.3.1. To the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Items was corrected under the supervision of the Classification Society Representative.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 May 2008
Resolved
1199-Hydraulic Leaks: 1)Ballast valve boxes on main deck One box by #4 hold. 2)Control boxes for hatch covers located on the starboard side are filled with oil. 3)Fwd port anchor windlass leaking at the control. 4)Hydraulic controls inside the forward Bos'n store. To the satisfaction of Class. ISM A/10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Items was corrected under the supervision of the Classification Society Representative.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 13 May 2008
Resolved
1760-Standard Discharge Connection (SDC): The port SDC has been cut and the stbd one has been modified. To the satisfaction of Class. MARPOL Con Ed 2006 Annex I Reg 13
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Items was noted by the Classification Society Representative, he issued a Condition of Class for the flanges to be replaced within two months.
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 May 2008
Resolved
0300- Accommodations: 1)The hot water line outside the 1st Eng stateroom is patched 2)The hot water line outside the hospital water closet is patched 3)The hot water line above the "B" deck exit door stbd side is patched 4)The hot water line outside the door to the hospital is patched. To the satisfaction of Class. ISM A/10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Item were noted by the Classification Society Representative. He issued a Condition of Class for the lines to be renewed at the next dry-docking in May 2009.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 13 May 2008
Resolved
0371-Hospital Space: Insecticide was found mixed with a first aid kit. The 2nd Mate stated that he needed to retain this in the hospital. Location fo insecticide should be located by itself. To the satisfaction of Class. ILO 147
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Items was corrected under the supervision of the Classification Society Representative.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 13 May 2008
Resolved
0399-Gymnasium: There is standing water on the deck in the port corner. It appears there is a leakage between the panel. The 3rd Mate was unsure where the water was coming from. Inspection must be carried out by Class. To the satisfaction of Class. ISM A/9. ISM A/10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2008
Resolution: Items was corrected under the supervision of the Classification Society Representative.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 June 2004
Resolved
Hold back devices on self closing class "A" doors in galley. Remove self closing devices. SOLAS 74 Amend II-2/47 LEGACY COMPONENT DESC: Openings - Doors
Action required: 15 - Rectify deficiencies by next port
Resolved 17 October 2005
Resolution: PSCO ensured proper operation of galley doors.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 June 2004
Resolved
Oily water separator (OWS) is currrently unable to produce effluent of less than 15 ppm. Prior to next use of OWS demonstrate proper operation. MARPOL Annex I. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Resolved 17 October 2005
Resolution: PSCO conducted an operational test of the Oily water separator (OWS) and verified proper operation of the system at 15ppm
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 12 June 2004
Resolved
Engine room currently has excessive five gallon cans of oil throughout, being used for cleaning. Remove all open five gallon containers of oil in engine room. SOLAS 74 Amend II-2/15.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 October 2005
Resolution: During the course of the inspection, the PSCO verified that portable containment cans had been removed.
Personnel › Training
Issued 25 April 2003
Resolved
Update the new crew familiarization training to comply with STCW 95. LEGACY COMPONENT DESC: Familiarization Training
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 June 2003
Resolution: THE NEW CREW NOW COMPLIES WITH THE TRAINING OF STCW 95 AND IS UPDATED.
Construction/Loadline › Penetrations
Issued 25 April 2003
Resolved
Repair as original or provide class approval of the temporary repair on the sewage overboard line outboard of the skin valve, SOLAS 74 AMD I/II. Rcvd fax from ClassNK approving of temporary repair and recommending permanent repairs to be conducted before 24JUN03. LEGACY COMPONENT DESC: Pipe Flange
Due 24 June 2003
Resolved 30 June 2003
Resolution: REPAIRS MADE TO THE SATISFACTION OF CLASSIFICATION SOCIETY.
Navigation
Issued 28 May 1996
Resolved
Vessel failed to notify nearest USCG COTP, or District Commander, that its secondary radar was not functioning normally.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Navigation
Issued 28 May 1996
Resolved
Prove proper operation of secondary radar, per 33 C.F.R. 164.37(a), prior to next U. S. port call.
Condition: Unknown
Due 31 March 1997
Resolved 31 March 1997