MAURY USCG vessel records
← All vessels

MARLYN

Built
1961
Last inspected
13 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 May 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAB9757
Flag
UNITED STATES
Maury page id
psix-44039

Documentation record

Registered dimensions (L × B × D)65.0 ft × 25.0 ft × 7.0 ft
Registered tonnagegross 70 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTURGEON BAY SHIPBUILDING · STURGEON BAY, WI, UNITED STATES · built 1961
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 19 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 40 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FRED A BUSSE Passenger (Inspected) · MISLE 59674 · 24 September 2023 · activity 7830705

Inspection history · 40

13 May 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8372565
25 March 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8331639
24 February 2025 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8083605
12 July 2024 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7956631
2 April 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7888486
7 March 2024 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7875055
1 November 2023 Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7819747
24 September 2023 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7830705
1 June 2023 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7710612
23 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7696640
21 April 2023 Deficiency Check · Deadweight Survey · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7671505
20 April 2023 MTSA Verification · In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7671162
23 February 2023 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7640666
7 November 2022 Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7590362
18 August 2022 Examination of Repairs · In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7537893
9 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7501776
11 March 2022 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7410011
7 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7249456
11 March 2021 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7154034
16 June 2020 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6978316
10 February 2020 Administrative Inspection · DAPI Audit · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6905974
4 October 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6828472
23 September 2019 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6818481
20 September 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6828426
4 April 2019 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6661033
28 November 2018 Plan Review "T" Boat · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6588962
6 September 2018 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6534240
1 August 2018 Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6499650
12 June 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6443951
12 April 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6390049
8 March 2018 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6370056
27 April 2017 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6134421
16 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6089949
12 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5970596
7 August 2016 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5968157
6 August 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5977140
25 July 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5952108
7 June 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5901841
26 May 2016 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5887765
22 January 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5801614

Deficiency record · 19

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2026 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] end cable found in fuel tank compartment. Remove the same. Cite: 46 CFR 183.01-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2026
Resolved 13 May 2026
Resolution: Owner provided photographic evidence of completion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026 Resolved
At least one ring life buoy must be fitted with a lifeline. Lifeline on ring life buoy port second deck is worn. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2026
Resolved 13 May 2026
Resolution: Owner provided photographic evidence of new lifline.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 25 March 2026 Resolved
New installations of piping systems on an existing vessel must be completed to the satisfaction of the [name withheld] pipes in sewage compartment and lazarette need proper installation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2026
Resolved 13 May 2026
Resolution: Owner provided photographic evidence of proper installation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2024 Resolved
Provide onboard portable fire extinguisher brackets type approved with extinguishers. Extinguishers did not properly fit into existing brackets.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2024
Resolved 1 April 2024
Resolution: Photos provided of proper brackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 June 2023 Resolved
While underway with passengers, vessel exprianced a loss of power. Vessel crew started the off libe generator and proceeded to dock without incident. Vessel is restricted from operation with passengers until generator is repaired and tested to the satisfaction of the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2023
Resolution: Impeller replaced and op tested.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 21 April 2023 Resolved
Each vessel must have permanent draft marks at each end of the vessel. The aft draft mark is missing. Provide draft marks at vessel's stern.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2023 Resolved
INSULATION FOR PORT AND STBD ENGINE EXHAUST PIPING NEEDS TO BE INSTALLED.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 28 April 2023
Resolution: Exhaust insluation was installed for both engines.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 April 2023 Resolved
SECTIONS OF STRUCTURAL FIRE PROTECTION INSULATION ARE MISSING IN ENGINE ROOM OVERHEAD. REPLACE INSULATION.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 4 May 2023
Resolution: Structural fire protection insulation was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 April 2023 Resolved
A WINDOW IN THE OPERATING STATION IS CRACKED/BROKEN. REPLACE WINDOW.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 28 April 2023
Resolution: Window has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 April 2023 Resolved
REPLACE WEATHER TIGHT COVER FOR MAIN DECK COOLER GFCI OUTLET.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 28 April 2023
Resolution: Cover for GFCI outlet has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 April 2023 Resolved
DRESS LIGHTING ON TOP OF VESSEL HAS BULBS FULL OF WATER. REMOVE FAULTED LIGHTING FROM VESSEL.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 28 April 2023
Resolution: Dress lights have been removed from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2019 Resolved
Repair Port MDE, send tech report, conduct sea trials
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2019
Resolved 4 October 2019
Resolution: Tested and conducted sea trials.
Electrical › Electric Generation Source (service) › Generator
Issued 8 March 2018 Resolved
Revise electrical one line to reflect modifications, and submit for approval to the Marine Safety Center, Submittal must include electrical load analysis 46 CFR 115.700
Action required: 705 - Other - as specified
Due 6 October 2018
Resolved 28 November 2018
Engineering › Fuel Oil Service System › Piping
Issued 7 August 2016 Resolved
Diesel fuel leaks in piping system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2016
Resolved 12 August 2016
Resolution: installed new fuel rail on #5.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 May 2016 Resolved
Repair or replace emergency light above emergency escape hatch on lower passenger deck. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 27 May 2016
Resolution: Light in escape trunk properly operating.
Engineering › Bilge Water Management System › Valve
Issued 26 May 2016 Resolved
Repair or replace bilge valve for collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2016
Resolution: Bilge valve and reach rod properly operating.
Engineering › Bilge Water Management System › Pump
Issued 26 May 2016 Resolved
Repair or replace installed bilge pump to meet minimum 50 gallons per minute. 46 CFR 182.25-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2016
Resolution: 50 GPM bilge pump was repaired. Inspector verified proper operation using water filled void.
Lifesaving › Line-Throwing Appliances › Lines
Issued 26 May 2016 Resolved
Replace Ring Buoy life line on portside life ring. 46 CFR 117.70(c)
Condition: Improper/Lack of Maintenance
Due 26 June 2016
Resolved 7 June 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 26 May 2016 Resolved
Replace / Repair wire insulation (in upper bar area). 46 CFR 183.05-45
Condition: Improper/Lack of Maintenance
Due 26 June 2016
Resolved 25 July 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.