Documentation record
Registered dimensions (L × B × D)65.0 ft × 25.0 ft × 7.0 ft
Registered tonnagegross 70 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTURGEON BAY SHIPBUILDING · STURGEON BAY, WI, UNITED STATES · built 1961
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 19 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 40 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 40
13 May 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8372565
25 March 2026
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8331639
24 February 2025
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8083605
12 July 2024
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7956631
2 April 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7888486
7 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7875055
1 November 2023
Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7819747
24 September 2023
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7830705
1 June 2023
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7710612
23 May 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7696640
21 April 2023
Deficiency Check · Deadweight Survey · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7671505
20 April 2023
MTSA Verification · In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7671162
23 February 2023
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7640666
7 November 2022
Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7590362
18 August 2022
Examination of Repairs · In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7537893
9 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7501776
11 March 2022
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7410011
7 July 2021
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7249456
11 March 2021
DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7154034
16 June 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6978316
10 February 2020
Administrative Inspection · DAPI Audit · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6905974
4 October 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6828472
23 September 2019
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6818481
20 September 2019
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6828426
4 April 2019
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6661033
28 November 2018
Plan Review "T" Boat · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6588962
6 September 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6534240
1 August 2018
Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6499650
12 June 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6443951
12 April 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6390049
8 March 2018
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6370056
27 April 2017
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6134421
16 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6089949
12 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5970596
7 August 2016
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5968157
6 August 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5977140
25 July 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5952108
7 June 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5901841
26 May 2016
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5887765
22 January 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5801614
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2026
Resolved
All electrical installations shall be to the satisfaction of the [name withheld] end cable found in fuel tank compartment. Remove the same. Cite: 46 CFR 183.01-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2026
Resolved 13 May 2026
Resolution: Owner provided photographic evidence of completion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026
Resolved
At least one ring life buoy must be fitted with a lifeline. Lifeline on ring life buoy port second deck is worn. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2026
Resolved 13 May 2026
Resolution: Owner provided photographic evidence of new lifline.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 25 March 2026
Resolved
New installations of piping systems on an existing vessel must be completed to the satisfaction of the [name withheld] pipes in sewage compartment and lazarette need proper installation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2026
Resolved 13 May 2026
Resolution: Owner provided photographic evidence of proper installation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2024
Resolved
Provide onboard portable fire extinguisher brackets type approved with extinguishers. Extinguishers did not properly fit into existing brackets.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2024
Resolved 1 April 2024
Resolution: Photos provided of proper brackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 June 2023
Resolved
While underway with passengers, vessel exprianced a loss of power. Vessel crew started the off libe generator and proceeded to dock without incident. Vessel is restricted from operation with passengers until generator is repaired and tested to the satisfaction of the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2023
Resolution: Impeller replaced and op tested.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 21 April 2023
Resolved
Each vessel must have permanent draft marks at each end of the vessel. The aft draft mark is missing. Provide draft marks at vessel's stern.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2023
Resolved
INSULATION FOR PORT AND STBD ENGINE EXHAUST PIPING NEEDS TO BE INSTALLED.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 28 April 2023
Resolution: Exhaust insluation was installed for both engines.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 April 2023
Resolved
SECTIONS OF STRUCTURAL FIRE PROTECTION INSULATION ARE MISSING IN ENGINE ROOM OVERHEAD. REPLACE INSULATION.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 4 May 2023
Resolution: Structural fire protection insulation was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 April 2023
Resolved
A WINDOW IN THE OPERATING STATION IS CRACKED/BROKEN. REPLACE WINDOW.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 28 April 2023
Resolution: Window has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 April 2023
Resolved
REPLACE WEATHER TIGHT COVER FOR MAIN DECK COOLER GFCI OUTLET.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 28 April 2023
Resolution: Cover for GFCI outlet has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 April 2023
Resolved
DRESS LIGHTING ON TOP OF VESSEL HAS BULBS FULL OF WATER. REMOVE FAULTED LIGHTING FROM VESSEL.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2023
Resolved 28 April 2023
Resolution: Dress lights have been removed from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2019
Resolved
Repair Port MDE, send tech report, conduct sea trials
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2019
Resolved 4 October 2019
Resolution: Tested and conducted sea trials.
Electrical › Electric Generation Source (service) › Generator
Issued 8 March 2018
Resolved
Revise electrical one line to reflect modifications, and submit for approval to the Marine Safety Center, Submittal must include electrical load analysis 46 CFR 115.700
Action required: 705 - Other - as specified
Due 6 October 2018
Resolved 28 November 2018
Engineering › Fuel Oil Service System › Piping
Issued 7 August 2016
Resolved
Diesel fuel leaks in piping system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2016
Resolved 12 August 2016
Resolution: installed new fuel rail on #5.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 May 2016
Resolved
Repair or replace emergency light above emergency escape hatch on lower passenger deck. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 27 May 2016
Resolution: Light in escape trunk properly operating.
Engineering › Bilge Water Management System › Valve
Issued 26 May 2016
Resolved
Repair or replace bilge valve for collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2016
Resolution: Bilge valve and reach rod properly operating.
Engineering › Bilge Water Management System › Pump
Issued 26 May 2016
Resolved
Repair or replace installed bilge pump to meet minimum 50 gallons per minute. 46 CFR 182.25-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2016
Resolution: 50 GPM bilge pump was repaired. Inspector verified proper operation using water filled void.
Lifesaving › Line-Throwing Appliances › Lines
Issued 26 May 2016
Resolved
Replace Ring Buoy life line on portside life ring. 46 CFR 117.70(c)
Condition: Improper/Lack of Maintenance
Due 26 June 2016
Resolved 7 June 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 26 May 2016
Resolved
Replace / Repair wire insulation (in upper bar area). 46 CFR 183.05-45
Condition: Improper/Lack of Maintenance
Due 26 June 2016
Resolved 25 July 2016