Records from 1985 to 2026. Most recent: inspection, 8 April 2026.
Inspection history · 88
8 April 2026
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8344373
8 December 2025
Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8276669
13 May 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7911917
30 May 2023
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7689489
2 March 2023
Internal Structural Exam · COI Inspection · Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7633476
8 June 2022
In-Service Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7472044
4 March 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7400796
12 May 2021
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7195326
22 April 2021
Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7180524
22 December 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7115055
3 September 2020
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7055943
16 April 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6943321
4 December 2019
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6867244
24 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6841169
19 April 2019
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6671204
6 December 2018
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6592737
18 April 2018
Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6393561
17 April 2018
Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6393398
3 December 2015
Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5774810
17 August 2015
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5220698
25 March 2014
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4822449
17 July 2012
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4381818
9 July 2012
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4373138
7 July 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4373417
10 January 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4221988
15 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4208818
21 September 2011
MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4150568
22 September 2010
MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3854980
5 May 2009
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3464640
8 October 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3340855
18 June 2008
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3249400
26 September 2007
Deficiency Check · MTSA Verification · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3066355
28 September 2006
COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2734600
7 June 2006
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2672889
4 November 2004
COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2234532
14 April 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2043737
29 May 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1802489
18 March 2003
Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1758855
21 November 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1709371
21 August 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1664321
21 August 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1664488
19 August 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1663228
3 April 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1600393
9 May 2001
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1063334
25 April 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1447084
4 July 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 148255
24 May 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1049928
19 April 2000
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1376135
20 October 1999
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1471724
8 October 1999
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1121744
7 October 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 125644
12 September 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 124974
22 July 1999
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1103210
21 July 1998
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 793796
22 May 1997
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1101417
10 December 1996
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1097676
16 August 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 128469
24 July 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1091041
28 June 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1088897
28 June 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1090824
22 May 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 881541
11 July 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 883374
31 May 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1184144
10 May 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858058
22 April 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 856955
3 June 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 847231
25 June 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 956696
22 May 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 955456
22 May 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 956789
1 May 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 953934
1 May 1992
Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 957996
9 December 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 944170
19 April 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 926652
17 October 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1238396
4 October 1990
Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 932121
30 April 1990
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 929798
24 April 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1204092
30 March 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1042869
9 February 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1340062
14 July 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1210020
7 April 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 994144
16 September 1987
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1314598
22 July 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1328725
23 April 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1013602
18 March 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 995106
16 September 1985
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1297541
6 September 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 989061
27 February 1985
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 987117
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 May 2021
Resolved
Small holes in overhead of laz. Crop/Renew in kind NLT 31OCT2021.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 May 2021
Resolved
Small holes in overhead on tank void. Crop/renew in kind NLT 31OCT2021.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2021
Resolved 9 June 2022
Resolution: Repaired in kind.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 December 2019
Resolved
The steel hull is corroded all the way through in several locations including; In the tank room, a hole in the overhead just forward of the 4th frame forward about 16" inboard from the starboard side. as well as knifing corrosion at the bottom of the 2nd frame forward on the starboard side in the same space. In the #2 Void, just aft of the 2nd frame forward, a hole in the overhead about 3" inboard from the starboard side.
Complete repairs prior to credit for next drydock.
46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 3 September 2020
Resolution: Operator cut out bad steel and made insert with new plate. Soap and blow test was conducted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 December 2018
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Bulkhead penetration found on bulkhead between void #2 and storage void #3 that was not watertight. Make penetration watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 12 December 2018
Resolution: Penetration was sealed and capped on both sides.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 December 2018
Resolved
Each life jacket must be marked with type 1 retroflective material. Found 35 life jackets with worn retroflective material. Renew retroflective material on identified lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 December 2018
Resolved 12 December 2018
Resolution: Retroflective tape replace on the spot by crew.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 April 2018
Resolved
Provide suitable/safe location for MOB ladder.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 23 April 2018
Resolution: Vessel rep. relocated ladder to a safer location.
Stability › Watertight Integrity › General
Issued 18 April 2018
Resolved
Vessel is past due for a credit hull exam. Complete exam prior to carrying passengers for hire.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2018
Resolution: Completed credit hull exam.
Engineering › Electric Propulsion System › Cable
Issued 9 July 2012
Resolved
Throttle cable broke at the MDE. A temp repair was done with a wire tie. A permanent repair must be made to the cable and the vessel must perform an underway operational test prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2012
Resolved 10 July 2012
Resolution: The cable that had broken was actually the clutch cable and not the throttle cable. The clutch cable had been switched out with a new cable from the controlling unit to the MDE. We conducte
Documentation › Certificates/Documents › Stability Letter
Issued 15 December 2011
Resolved
The vessel's owner/operator has not requested an initial or updated stability letter or has not certified compliance with the revised stability criteria for assumed average weight per person (AAWPP) of 185 pounds. Based upon a weight ratio calculation, the vessel's capacity is therefore limited to: 161 persons (passengers and crew). 46 CFR 170.090
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 10 January 2012
Resolution: Received Stability Letter Addendum changing the allowable persons on board from 213 to 161. COI has been ammended. 835 cleared.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 September 2011
Resolved
Three type 1 child size lifejackets were found to be non-serviceable. Provide three new CG approved child size lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2011
Resolved 14 October 2011
Resolution: Vessel provided three new CG approved child life jackets.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 September 2011
Resolved
Cap off the access hole on the left side of the electrical panel in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2011
Resolved 14 October 2011
Resolution: Access hole on the left side of the engine room electrical panel has been properly capped.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 October 2008
Resolved
Replace 6 lifejackets that were condemded.
Due 9 October 2008
Resolved 22 October 2008
Resolution: Lifejackets replaced.
Construction/Loadline › Hull › Side Shell
Issued 8 October 2008
Resolved
repair small holes in sideshell above the main deck windows.
Due 23 October 2008
Resolved 22 October 2008
Resolution: All holes repaired sat.
Engineering › Bilge Water Management System › Not Operational
Issued 8 October 2008
Resolved
Repair or replace bilge high level alarm.
Due 23 October 2008
Resolved 22 October 2008
Resolution: repaired sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 September 2007
Resolved
Repair broken overhead light in engine room.
Due 10 October 2007
Resolved 18 October 2007
Resolution: light repaired sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 September 2007
Resolved
Make permanent repair to port running light mount.
Due 10 October 2007
Resolved 18 October 2007
Resolution: nav light repaired sat.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 26 September 2007
Resolved
Repalce broken window on main deck stbd side aft.
Due 10 October 2007
Resolved 18 October 2007
Resolution: new window installed sat.
Construction/Loadline › Hull › Side Shell
Issued 26 September 2007
Resolved
Repair small holes in sideshell above waterline IWO above main deck windows and stem area.
Due 10 October 2007
Resolved 18 October 2007
Resolution: This item to be conducted during spring 2008 dry-dock. Note added.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 26 September 2007
Resolved
replace handle for sewage overboard disharge valve.
Due 10 October 2007
Resolved 18 October 2007
Resolution: Sewage discharge handle repaired sat.
Electrical › Electric Generation Source (service) › Generator
Issued 28 September 2006
Resolved
Prove proper operation of vessel's secondary ship service generator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 October 2006
Resolved 10 October 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 June 2006
Resolved
Make vessel available for full, 5-year COI exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2006
Resolved 28 September 2006
Construction/Loadline › Structures › Deck Plating
Issued 7 June 2006
Resolved
Crop and renew as original, wasted deck plating IWO #2 void stbd side at end of bar counter.
Action required: 705 - Other - as specified
Resolved 22 June 2006
Resolution: Examined satisfactory plate insert.
Engineering › Bilge Water Management System › Strainer
Issued 7 June 2006
Resolved
Provide proper strainers, with a minimum area of 3 times the diameter of pipe, for bilge suction lines in emgine room and #5 void.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 28 September 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 7 June 2006
Resolved
Renew broken window in main passenger compartment, stbd/aft (last window).
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 28 September 2006
Construction/Loadline › Penetrations › Valve Flange
Issued 7 June 2006
Resolved
Make available for inspection sea valve at sea chest for salt water pump line for heads.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Resolution: [name withheld] examined sea valve. All sat.
Construction/Loadline › Structures › Deck Plating
Issued 7 June 2006
Resolved
Crop and renew as original, wasted 2nd deck plating stbd/aft.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 28 September 2006
Construction/Loadline › Hull › Hull Plating
Issued 7 June 2006
Resolved
Provide gauging results for hull.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Resolution: [name withheld] examined gauging results. All readings show less than 25% wastage. All sat.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 November 2004
Resolved
Prove proper operation of ground dectection device on main switchboard.
Action required: 705 - Other - as specified
Due 4 December 2004
Resolved 7 June 2006
Resolution: Examined and found sat.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 4 November 2004
Resolved
Provide 6 additioanal child-size PFDs for a total of 22. Until complete, vessel may only carry a maximum of 16 persons that are either less than 45 pounds or less than 47b inches tall.
Action required: 705 - Other - as specified
Due 4 December 2004
Resolved 2 February 2005
Resolution: Received fax receipt for 6 new child PFDs.
Engineering › Fuel Oil Service System
Issued 14 April 2004
Resolved
Separate SSDG common fuel return piping from electrical ground wire running through same conduit. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 30 April 2004
Resolution: Examined by [name withheld] and found satisafctory.
Electrical › Electrical Distribution System (service)
Issued 14 April 2004
Resolved
Prove proper operation of switchboard meters and ground detection, and replace missing fuses. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 21 May 2004
Resolution: Examined switchboard and found all satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2004
Resolved
Properly terminate 2 dead-ended wires under console in pilothouse IWO helm.
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 30 April 2004
Resolution: Examined by [name withheld] and found satisfactory.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 April 2004
Resolved
Prior to carrying passengers, crop and renew as original lower half of 8 wasted bulkhead stiffeners in #5 void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2004
Resolved 30 April 2004
Resolution: Examined by [name withheld] and found satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 April 2004
Resolved
Provide 6 additional child-size PFDs for a total of 22. Until complete, vessel limited to carrying 16 children.
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 30 April 2004
Resolution: [name withheld] examined and found satisfactory 6 new child PFDs.
Engineering
Issued 29 May 2003
Resolved
Main engine alarm to be made visible at control console.
Due 20 June 2003
Resolved 2 July 2003
Engineering
Issued 29 May 2003
Resolved
Provide aft generator lube oil and jacket water temp gauges at operating station.
Due 20 June 2003
Resolved 2 July 2003
Engineering
Issued 29 May 2003
Resolved
Provide guard on front of main engine.
Due 20 June 2003
Resolved 2 July 2003
Accommodation/Occupational Safety
Issued 29 May 2003
Resolved
Provide rung at 42" height around entire main deck except where fixed glass exists.
Due 5 July 2003
Resolved 2 July 2003
Construction/Loadline › Structures
Issued 18 March 2003
Resolved
Crop and renew wasted main desk steel to good steel to port fuel tank and aft above enine room, engine room overhead centerline 1 foot aft of main deck stairwell, and fill 2 - 2mm holes in stbd fuel tank overhead. LEGACY COMPONENT DESC: Deck Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2003
Resolved 25 April 2003
Resolution: Repairs completed.
Construction/Loadline › Structures
Issued 18 March 2003
Resolved
Crop and renew stbd fuel tank overhead to good steel. LEGACY COMPONENT DESC: Deck Plating
Due 28 February 2004
Resolved 2 July 2003
Engineering › Bilge Water Management System
Issued 21 November 2002
Resolved
Prior to carrying passengers, prove proper operation of the bilge piping system from each space. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 29 May 2003
Communications › Alarms/Indicators
Issued 21 November 2002
Resolved
Prior to carrying passengers, properly repair and test the high water bilge alarms in the lazarette space and the #5 void space. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2003
Resolved 29 May 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 3 April 2002
Resolved
Renew broken light fixture in engine room.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Resolution: Examined new fixture and found satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2002
Resolved
Remove dead end cable port side in the engine room.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Engineering › Fuel Oil Service System › Hose
Issued 3 April 2002
Resolved
Install chafing protection for fuel line for westerbeke generator.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 April 2002
Resolved
Replace plug in main engine cooling water strainer and clean.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Engineering › Bilge Water Management System
Issued 3 April 2002
Resolved
Provide bilge strainer in packing gland compartment.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Engineering › Bilge Water Management System
Issued 3 April 2002
Resolved
Provide strainer screen to bilge suction line in # 1 void space.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 3 April 2002
Resolved
Reweld hand railing stanchions and supporting members on upper deck.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Construction/Loadline › Structures
Issued 3 April 2002
Resolved
Repair pilot house plating.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 3 April 2002
Resolved
Repair hand railing located port side.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Deck/Cargo
Issued 3 April 2002
Resolved
Resurface upper deck areas that are damaged.
Due 18 April 2002
Resolved 18 April 2002
Construction/Loadline › Hull › Weld
Issued 3 April 2002
Resolved
Plug weld hole located in #2 compartment.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Construction/Loadline › Structures › Scupper
Issued 3 April 2002
Resolved
Reweld main deck old freeing ports.
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 18 April 2002
Lifesaving
Issued 25 April 2001
Resolved
Update equipment in the first aid kit
Condition: Unknown
Due 25 April 2001
Resolved 26 April 2001
Electrical
Issued 25 April 2001
Resolved
Provide a belt and pulley guard for the aft generator
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 25 April 2001
Resolved
Provide three child sized life preservers
Condition: Unknown
Due 25 April 2001
Resolved 26 April 2001
Lifesaving
Issued 19 April 2000
Resolved
MAKE VESSEL AND CREW AVAILABLE TO CONDUCT UNDERWAY DRILLS TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 19 April 2000
Resolved 19 April 2000
Construction/Loadline
Issued 22 July 1999
Resolved
CROP AND RENEW BULKHEAD FRAME, #5 VOID, STBD SIDE, OUTERMOST FRAME.
Condition: Unknown
Due 25 August 1999
Resolved 15 September 1999
Accommodation/Occupational Safety
Issued 22 July 1999
Resolved
REPAIR WINDOW IN STBD SIDE LOADING DOOR.
Condition: Unknown
Due 25 August 1999
Resolved 15 September 1999
Construction/Loadline
Issued 22 July 1999
Resolved
CROP AND RENEW LONGITUDINAL FRAME, AFTER LAZARETTE, STBD SIDE.
Condition: Unknown
Due 25 August 1999
Resolved 15 September 1999
Construction/Loadline
Issued 28 June 1996
Resolved
REPAIR HOLED STBD LOADING DOOR COAMING.
Condition: Unknown
Due 28 June 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
#2 COMPT.- RENEW #1,2,3 AND 4 FLOOR FRAMES. CROP TO GOOD STEEL AND RENEW TRANSVERSE FRAME ENDS 1 THROUGH 4, PORT AND STBD.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
REPAIR STBD LOADING DOOR WHERE FRACTURED.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Engineering
Issued 28 June 1996
Resolved
CROP TO GOOD STEEL AND RENEW APPROXIMATELY 2 FEET OF THE PORT SIDE MAIN ENGINE EXHAUST. (FROM TRANSOM FWD 2 FEET)
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
CROP TO GOOD STEEL AND RENEW FRAMES 1 AND 4 PORT AND THE PORT LONGITUDINAL STRINGER.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
RENEW PORT SIDE LONGITUDINAL STINGER. CROP TO GOOD STEEL AND RENEW FRAMES 2,3,4, AND 5 PORT AND #5 STBD. PROVIDE GUAGINGS OF THE LOWER 2 FEET OF THEFWD AND AFT WATERTIGHT BHDS.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
CROP TO GOOD STEEL AND RENEW WASTED BOTTOM PLATING UNDER MAIN ENGINE ON THEPORT AND STBD SIDES OF KEEL.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
#3 COMPT.- CROP TO GOOD STEEL AND RENEW FRAME #4 PORT.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
RENEW AFT HATCH COAMING ON UPPER PASSENGER DECK.
Condition: Unknown
Due 28 June 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
REMOVE DECK COVERING FROM THE AFT STBD CORNER OF THE UPPER PASSENGER DECK, GUAGE AND PROPOSE REPAIR WHERE HOLED.
Condition: Unknown
Due 28 June 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
PROVIDE GUAGINGS OF COLLISION BULKHEAD FROM APPROX. 2 FEET ABOVE KEEL AND OUTBOARD PORT AND STARBOARD.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Construction/Loadline
Issued 28 June 1996
Resolved
PROVIDE GUAGING REPORT ON HULL TO DETERMINE EXTENT OF BOTTOM INSERTS NECESSARY.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Accommodation/Occupational Safety
Issued 28 June 1996
Resolved
REPLACE FRACTURED WINDOW ON THE PORT SIDE OF THE MAIN DECK ACCOMMODATION SPACE.
Condition: Unknown
Due 22 July 1996
Resolved 5 August 1996
Accommodation/Occupational Safety
Issued 28 June 1996
Resolved
LABEL PORT AND STBD EMERGENCY FUEL OIL SHUT-OFF VALVES.
Condition: Unknown
Due 22 July 1996
Resolved 6 August 1996
Accommodation/Occupational Safety
Issued 28 June 1996
Resolved
WELD SUPPORT ON FORWARD PORT HAND RAIL.
Condition: Unknown
Due 22 July 1996
Resolved 5 August 1996
Fire Fighting
Issued 28 June 1996
Resolved
PROVIDE PROPER BRACKET FOR THE ENGINE
Condition: Unknown
Due 22 July 1996
Resolved 5 August 1996
Accommodation/Occupational Safety
Issued 31 May 1995
Resolved
RENEW FRACTURED WINDOWS ON THE STARBOARD SIDE OF PILOT HOUSE AND THE PORT SIDE (AFT) ACCOMMODATION SPACE.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Construction/Loadline
Issued 31 May 1995
Resolved
CLEAN AREA AROUND BILGE SUCTIONS IN THE #5 AND #6 COMPARTENTS.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Construction/Loadline
Issued 31 May 1995
Resolved
RENEW BILGE PUMP OVERBOARD VALVE HANDLE IN THE #5 COMPARTMENT STARBOARD SIDE.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Fire Fighting
Issued 10 May 1994
Resolved
REPLACE LOVE JOY COUPLING ON FIRE PUMP DRIVE.
Condition: Unknown
Due 10 May 1994
Resolved 13 May 1994
Electrical
Issued 10 May 1994
Resolved
INSTALL LAGGING ON #2 SHIPS SERVICE GENERATOR EXHAUST PIPE.
Condition: Unknown
Due 10 May 1994
Resolved 13 May 1994
Lifesaving
Issued 10 May 1994
Resolved
PROVIDE 12 ADULT TYPE 1 PFD'S.
Condition: Unknown
Due 10 May 1994
Resolved 13 May 1994
Documentation
Issued 22 April 1994
Resolved
MAKE VESSEL AVAILABLE FOR INSPECTION FOR CERTIFICATION PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 30 April 1994
Resolved 10 May 1994
Construction/Loadline
Issued 22 April 1994
Resolved
CLEAN BILGES AND VOID SPACES SO AS TO ALLOW PROPER ACCESS TO BILGE DEWATERING SUCTION STRAINERS.
Condition: Unknown
Due 30 April 1994
Resolved 10 May 1994
Unknown
Issued 22 April 1994
Resolved
REPLACE STANTION IN VOID SPACE #4.
Condition: Unknown
Due 30 April 1994
Resolved 10 May 1994
Electrical
Issued 22 April 1994
Resolved
REMOVE/REPLACE EXTENSION CORD WIRE FOR LIGHT SWITCH (120 VOLT) LEADING TO ENGINE ROOM.
Condition: Unknown
Due 30 April 1994
Resolved 10 May 1994
Navigation
Issued 3 June 1993
Resolved
PRIOR TO GETTING UNDERWAY, PROVE PROPER OPERATION OF THE VESSEL'S ANCHOR LIGHT TO THE SATISFACTION OF AN ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Fire Fighting
Issued 3 June 1993
Resolved
PROVIDE ONBOARD A PORTABLE HAND OPERATED FIRE/BILGE PUMP MEETING THE REQUIREMENTS OF 46 CFR PART 181.10-5. A TEMPORARY HAND OPERATED FIRE/BILGEPUMP SHALL REMAIN ONBOARD UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Navigation
Issued 3 June 1993
Resolved
PROVIDE A VALID COMPASS DEVIATION TABLE FOR THE VESSEL'S COMPASS.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Documentation
Issued 3 June 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Electrical
Issued 1 May 1992
Resolved
REPLACE COOLING WATER HOSE ON SHIP SERVICE GENERATOR WHERE CHAFED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Accommodation/Occupational Safety
Issued 1 May 1992
Resolved
RENEW BILGE LINE WHERE WASTED IN VOID SPACE AFT OF ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Accommodation/Occupational Safety
Issued 1 May 1992
Resolved
PROVIDE CAP FOR OPEN THRU HULL PIPE LOCATED ON STARBOARD SIDE OF THE ENGINEROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Accommodation/Occupational Safety
Issued 1 May 1992
Resolved
SECURE ICE BOX IN GALLEY AREA._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Accommodation/Occupational Safety
Issued 1 May 1992
Resolved
PROVE OPERATION OF FORE PEAK BILGE SUCTION VALVE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Electrical
Issued 1 May 1992
Resolved
SECURE ELECTRICAL OUTLET BOX IN CEILING OF PASSENGER CABIN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Navigation
Issued 1 May 1992
Resolved
PROVE OPERATION OF EMERGENCY TILLER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Construction/Loadline
Issued 1 May 1992
Resolved
RENEW REPAIR MOORING BITS WHERE FRACTURED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Lifesaving
Issued 1 May 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Navigation
Issued 1 May 1992
Resolved
PROVIDE NAVIGATIONAL RUNNING LIGHTS IN ACCORDANCE WITH COLREGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Lifesaving
Issued 1 May 1992
Resolved
PROVIDE 16 ADDITIONAL ADULT PFD'S_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Lifesaving
Issued 1 May 1992
Resolved
PROVIDE VISUAL DISTRESS SIGNALS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Lifesaving
Issued 1 May 1992
Resolved
PROVIDE 24" RING BUOY WITH WATER LIGHT, AND LINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Lifesaving
Issued 1 May 1992
Resolved
PROVIDE RESCUE LADDER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Fire Fighting
Issued 1 May 1992
Resolved
REMOVE EXTRA FIRE EXTINQUISHER BRACKET IN PILOT HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1992
Resolved 29 May 1992
Fire Fighting
Issued 1 May 1992
Resolved
PROVIDE MOUNT FOR FIRE EXTINGUISHER IN GALLEY AREA.
Condition: Unknown
Due 1 May 1992
Resolved 1 May 1992
Lifesaving
Issued 1 May 1992
Resolved
PROVIDE LABELS/MARKING FOR LIFEJACKET STORAGE EMERGENCY ESCAPE, AND EMERGENCY FUEL SHUT DOWNS AS PER 46 CFR 185.30.
Condition: Unknown
Due 1 May 1992
Resolved 1 May 1992
Unknown
Issued 9 February 1989
Resolved
THE REQUIRED EMERGENCY CHECK OFF LIST WAS NOT POSTED.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Unknown
Issued 9 February 1989
Resolved
THE WARNING OF ILLEGAL DISCHARGE OF OIL WAS NOT POSTED AS REQUIRED.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Unknown
Issued 9 February 1989
Resolved
THE EXPIRATION DATE OF THE SIX FLARES ONBOARD HAS PASSED.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Navigation
Issued 9 February 1989
Resolved
STARBOARD NAVIGATION WAS NOT FUNCTIONING AT THE TIME OF THE INSPECTION.
Condition: Unknown
Due 9 February 1989
Resolved 9 February 1989
Construction/Loadline
Issued 7 April 1988
Resolved
REWELD (PREVIOUS WELDED) FRACTURE LOCATED IN 2ND FRAME FROM STERN, STBD SIDE APPROX 2.5' FROM SIDE SHELL.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Lifesaving
Issued 23 April 1987
Resolved
VESSEL IS LIMITED TO 182 TOTAL PERSONS ON BOARD UNTIL ADDITIONAL LIFE PRESERVERS ARE PROVIDED
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987