Records from 1996 to 2025. Most recent: inspection, 21 September 2025.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 September 2025
No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
A report was received that D III was partially submerged in Road Town, Tortola. MI contacted vsl owner; Owner stated the rudder was removed in order to change props and the vessel took on water.
A damage survey and written report shall be provided in writing by a qualified marine surveyor. The survey shall include a full assessment of the vessels structure, all equipment, and overall condition of seaworthiness.
A root cause and analysis shall be provided in writing to MSU St. Thomas for review. A determination of casual factors shall be provided and all steps taken to safely recover the vessel.
Owner shall provide a detailed and written repair plan and submit to Marine Safety Unit St. Thomas for review. Once the repair plan has been reviewed, a response will be provided to the owner prior to commencing repairs.
All Repairs and/or alterations will need to be reviewed prior to commencing and will require Coast Guard oversight throughout process.
All above mentioned requirements shall be met to the satisfaction of Marine Safety Unit St. Thomas prior to operating commercially in USVI waters. D III is required to conduct a USCG COI inspection prior to continuing operations in USVI waters. In addition, a drydock inspection may be required. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2025
Resolved
If your vessel is operated on international voyages.....
it must undergo a drydock examination once every 12 months.
D III did not conduct yearly drydock inspection as indicated on USCG COI.
Coordinate with USCG for scheduling for drydock inspection and provide intentions for operating in USVI prior to carrying passengers in USVI.
46 CFR 176.600(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2025
Resolved 23 April 2025
Resolution: Vessel underwent satisfactory drydock & internal structural exam.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Main passenger cabin deck plating was not secured and provided open access to engine room which is protected with CO2. Multiple areas of the engine room allowed the passage of vapors. Provide repair plan for securing deck plating and making engine room vapor tight. Submit repair plan for approval prior conducting repairs. Make engine room vapor tight as original.
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 27 June 2024
Resolution: met requirment
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jacket stowage was not seperate from adults. Stow child life jacket seperately and label prior to COI issuance.
46 CFR 180.78(a)(5)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Stbd ER battery bank and wiring was found wasted; replace battery and install battery wiring as required prior to COI issuance.
46 CFR 183.200 (b)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024
Resolved
All engines must be water cooled and meet the requirements of this paragraph.A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. ME (port) raw water strainer housing was found without strainer, replace as required prior to COI issuance.
46 CFR 182.420 (a)(2) 46 CFR 182.100
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Bother caps on raw water strainers were found with temp repairs and broken, replace as required
46 CFR 182.100
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024
Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant.
ER access hatch insulation was removed; replace as required
46 CFR 177.410(c)(4)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Steering linkage bolts were inverted, rearrange linkage bolts
46 CFR 182.100
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 April 2024
Resolved
Shall be provided with individual bigle lines and suctions for each water tight compartment.
Aft steering bilge system float switch was broken and ovbd discharge was not properly configured
46 CFR 182.25-5(a)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024
Resolved
Shut off valve at the tank shall be operable from outside the tank compartment.
Emergency Fuel COV was not operable and linkage was wasted, make COV operable and replace fasteners. Also secure pull handle closure box and label.
46 CFR 182.20-40(b)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 April 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
MI discovered daylight from multiple areas on main deck to aft steering. Make permanent repairs to deck plating.
46 CFR 177.100
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024
Resolved
All fuel tanks shall be electrically bonded to the common ground.
Vsl rep did not know which fuel tank piping was for vent or fill. Electrical bonding was not installed; install bonding on fill side.
46 CFR 182.20-25(b)(4)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024
Resolved
Filling and sounding pipes shall be so arranged that overflow of liquid or vapor cannot escape to the inside of the vessel.
Wasted piping was discovered above fuel tank on fill/vent. Replace fuel tank piping in corroded sections.
46 CFR 182.20-30(b)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 April 2024
Resolved
The general construction shall be such as to minimize fire hazarards.
Seal bulkhead penetrations in ER protected with CO2
46 CFR 177.10-5(a)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024
Resolved
All electrical installations shall be to the satisfaction of the OCMI, Marine Inspections.
Electrical junction box in aft steering and ER was not sealed; seal as required
46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 April 2024
Resolved
All watertight doors in subdivision bulkheads must be kept tightly closed during the navigation of the vessel except when being used for transit between compartments.
Aft steering water tight hatch gasket is wasted; replace gasket
46 CFR 185.330(b)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 April 2024
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.
MOB drill: Effective communication was lacking, and boat hook was not on board. Crew was not competent with drill. Run drill again and demonstrate crew proficiency.
46 CFR 185.520(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2024
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer.
Covered employee list from 2022. Provide current covered employee list. 46 CFR 16.210
Action required: 705 - Other - as specified
Due 27 June 2024
Resolved 27 June 2024
Resolution: met requirment
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2024
Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall inspect all lifesaving equipment to determine
its serviceability. Port and starboard liferaft cradle lashing pelican hooks found loose and unsecured. Properly secure liferafts to the cradles in accordance with manufacturers instructions.
Action required: 705 - Other - as specified
Due 27 June 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical smoke was observed.
Provide technical report and diagnosis for approval in addition to making necessary repairs of electrical system.
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 27 June 2024
Resolution: met requirment
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 15 April 2024
Resolved
he construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection.
MI discovered passenger gangway access door secured with bailing wire. Make repairs IAW original design.
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 27 June 2024
Resolution: met requirment
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 April 2024
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary
to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended. Electrical wiring and steering hoses below operating station covered in hydraulic fluid. Clean all affected wires, cables, and hoses for USCG reinspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2022
Resolved
Bilge and drainage systems. The means provided for pumping bilges shall be tested by operation. Attending MI's were unable to test bilge suction in after steering due to oily bilge conditions. Also did not function correctly in FWD lower compartment.46CFR176.25-1 (b)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 4 November 2022
Resolved
The fire pump shall be tested and the fire hose shall be subjected to the available fire pump pressure. The fire pump was inoperable during USCG Inspection.46CFR176.25-25
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 November 2022
Resolved
Re-inspection conducted of lifesaving equipment shall be made as deemed necessary by the Officer in Charge of marine inspection. Attending MI's noted that the IBA's listed on vessels BVI and USCG COI's have been replaced by life floats.46CFR176.25-22
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2022
Resolved
At each inspection for certification and re inspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Attending MI's noted excessive oil in the engine room and steering compartment bilges. 46CFR176.25-50(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 November 2022
Resolved
Electrical equipment shall be reasonably safe from electrical shock of personal. The breaker panel which contains the fire pump breaker has loose and missing a cover. 46CFR183.01-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 November 2022
Resolved
Fire hose length shall be not less than 25 feet and not more than 50 feet. Attending MI’s noted that he fire hoses on board were 100 feet in length which will reduce their effectiveness in an emergency. 46CFR181.15-10 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 November 2022
Resolved
Fuel systems installed shall be checked and tested by operation locally and at remote locations. Attending MI's noted that the fuel shut off valve was inaccessible and not conducive to easy rapid closing of the fuel.46CFR176.25(5)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 4 November 2022
Resolved
Flexible or portable cords such as SO, STO and similar types cannot be used for permanently installed wiring. Attending MI's noted a wired plug over the sink. 46CFR183.10-10(c)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 4 November 2022
Resolved
Suitable covers, guards or rails shall be installed in a way of all exposed and hazardous places such as gears and machinery. The installed generator guard is insufficient to protect crew.46CFR177.35-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 November 2022
Resolved
Deck Rails shall be installed near the periphery of all weather decks accessible to passengers and crew. Attending MI's noted that the after most port handrail was loose and easily pushed out with minimal force. 46CFR177.35(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 November 2022
Resolved
Battery connections shall be made to the battery terminals with permanent type connections. Spring clips or other temporary type clams are not permitted. Attending MI's noted that numerous battery terminals of the temporary type. 46CFR183.05-20(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 4 November 2022
Resolved
All wires shall terminate in a junction box. MI's noted
open wires top of open deck, lower forward compartment and in the engine room. All dead ended or unused wires shall be terminated in a junction box. 46CFR183.10-20
46CFR183.10-20
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2022
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas or liquid the temperature of which exceeds 150F, must be suitably insulated where necessary to prevent injuries. Attending MI's noted that the exhaust manifold expansion joints before the water inlet were uninsulated. 46CFR177-970, 46CFR182.20-20
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2022
Resolved
Vessel shall be inspected for compliance with standards required by this sub chapter. Jacket water piping for both main engines is being held in place with plastic wire ties as opposed to permeate pipe hangers. 46CFR176.25
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 November 2022
Resolved
Escape hatch located under operating station console blocked by storage items. Remove all storage items blocking hatch. 46 CFR 185.310-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2022
Resolved
C02 fixed firefighting system activation pull station at the operating station not marked. 46 CFR 181.20-15(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2022
Resolved
C02 fixed firefighting system activation pull station does not have operating instructions. 46 CFR 181.20-15(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2022
Resolved
Provide C02 fixed firefighting system servicing report for inspection. 46 CFR 176.25-25(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 November 2022
Resolved
All electrical cables and wiring in the engine room are suspended by plastic zip ties. Wiring and cables must be suspended by metal supports not more than 24” apart in a manner to avoid chaffing. 46 CFR 183.340(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 4 November 2022
Resolved
Metal Sheaving & insulation needs replacement Eng. Room 46CFR176.25
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 August 2022
Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. If your vessel is operated on international voyages subject to SOLAS requirements, it must undergo a drydock examination once every 12 months unless it has been approved to undergo an underwater survey (UWILD) per § 176.615 of this part.
Operator failed to complete required drydock by inspection date listed on COI of 31July2022.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2022
Resolved 7 December 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 24 February 2022
Resolved
Provide proof of DAPI compliance of a chemical testing program for the crew and current enrollment list.
Action required: 705 - Other - as specified
Resolved 2 March 2022
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 24 February 2022
Resolved
Post Stability Letter and COI outside the operating station where passengers can view them.
Action required: 705 - Other - as specified
Resolved 2 March 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 February 2022
Resolved
EPIRB battery & hydrostatic release unit expired.
Action required: 705 - Other - as specified
Resolved 2 March 2022
Resolution: New EPIRB purchased
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2022
Resolved
Aft Life Ring out of service
Action required: 705 - Other - as specified
Resolved 2 March 2022
Resolution: New lifering provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Properly wire aft door lighting into an electrical box.
Action required: 705 - Other - as specified
Resolved 2 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Remove portable pump plugged into aft door outlet.
Action required: 705 - Other - as specified
Resolved 2 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Provide light fixture on stbd side near aft door.
Action required: 705 - Other - as specified
Resolved 2 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2022
Resolved
Properly mark fuel shut-off valve.
Action required: 705 - Other - as specified
Resolved 2 March 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 July 2019
Resolved
Controls and valves for operation of fixed gas fire extinguishing system must be located outside of the space protected by the system. The D III fixed fire extinguishing system control valves are located in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 1 October 2019
Resolution: Controls were moved to the compartment forward of the engine room. outside of the protected space.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 April 2019
Resolved
Provide a fire detection system or a fixed gas system capable of automatic activation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2019
Resolution: Fire system has heat activated automatic discharge installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 April 2019
Resolved
Conduct man overboard and fire drill.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2019
Resolution: Witnessed drills
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 April 2019
Resolved
Provide proof of enrollement in DAPI consortium.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2019
Resolution: Witnessed proof of enrollment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2019
Resolved
Separate child's lifejackets from adults.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2019
Resolution: Lifejackets seperated.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2019
Resolved
Post stability letter in wheel house.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 April 2019
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance (DoC/ ISM)
Issued 2 April 2019
Resolved
Provide current BVI issued DOC.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2019
Resolution: Provided.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 2 April 2019
Resolved
Prove proper operation of public address system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2019
Resolution: Witnessed proper operation.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 December 2018
Resolved
Due to steering casualty, make vessel available for dry dock exam by attending USCG Marine Inspector.
All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Vessel made available for drydock inspection by attending USCG marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 December 2018
Resolved
Identify source of water ingress in way of port side transom lazarette & provide repair proposal.
All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Vessel made repairs following identification of a crack in the port strut allowing propogation into lazarette. Repairs overseen by BVI VISR.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 4 December 2018
Resolved
Identify source of dirty oil in lazarette.
All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Oil propogated through old through bulkhead fitting that was not properly secured. Vessel secured and stopped movement of liquid.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 4 December 2018
Resolved
Remove all oil and oily residues in lazarette and engine room.
All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Oil and residues removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018
Resolved
Provide manufacturers instructions for drip-less shaft seals.
All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Manufacturers instructions provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2018
Resolved
Properly secure deck plates in main cabin.
All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Deckplates secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018
Resolved
Make permanent repairs or replace leaking shaft seal oil reservoirs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Leaks secured.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2018
Resolved
Provide deck rails atleast 39.5" tall with rail courses atleast every 4 inches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2018
Resolved 29 January 2019
Resolution: Vessel sent pictures showing installation of grating that meets course requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018
Resolved
Replace starboard shaft seal.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Starboard shaft seal replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018
Resolved
Replace starboard steering tiller.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Tiller replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2018
Resolved
Provide survey report from Virgin Islands [name withheld] attesting to proper repairs to both shaft struts and bottom plate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: VISR report showing deficiencies and dates cleared provided.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 June 2018
Resolved
Crop and renew inset on starboard side shell below pilot house in way of chine.
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 2 July 2018
Resolution: Area cropped and renewed with no CG oversight.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 June 2018
Resolved
Make connection between sea valve and through hull fitting for generator raw water cooling with metallic piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2018
Resolution: Sea valve threaded to through hull fitting.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 March 2018
Resolved
Provide records for servicing of fixed firefighting (CO2) system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2018
Resolution: Vessel provided servicing report.
Communications › Radio Communications › EPIRB
Issued 8 March 2018
Resolved
Mount EPIRB to facilitate float free release.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: EPIRB mounted properly.
Lifesaving › Lifefloat › Float-free Link
Issued 8 March 2018
Resolved
Provide weak link for life float.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Lifelfoat weak link provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 8 March 2018
Resolved
Provide instructions for CO2 system.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel posted instructions for CO2 system.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 March 2018
Resolved
Mount and protect ship service circuit breaker.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel mounted circuit breaker.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 8 March 2018
Resolved
Provide servicing certificate for IBA
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Servicing certificate provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 March 2018
Resolved
Provide generator fan belt guard.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Fan belt guard provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 March 2018
Resolved
Provide DSC Radio with MMSI and GOS input
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel replaced DSC VHF with compliant one.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 March 2018
Resolved
Mount lazarett bilge alarm.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel mounted bilge alarm.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 March 2018
Resolved
Provide lid for generator start batteries.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel provided battery box cover.
Engineering › Bilge Water Management System › Pump
Issued 8 March 2018
Resolved
Provide suitable emergency/hand bilge pump.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Hand bilge pump provided with long enough hose.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 March 2018
Resolved
Secure stern bench seat in place.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Bench seat secured.
Lifesaving › Lifefloat › Markings
Issued 8 March 2018
Resolved
Mark vessel name on life float.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Vessel name marked.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 March 2018
Resolved
MArk vessel noame on ring buoy.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Vessel name marked.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 March 2018
Resolved
Provide lanyard and clip for life buoy.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Lanyard and clip provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 March 2018
Resolved
Attach buoyant lifeline around body of life buoy.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Lifeline attached.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 March 2018
Resolved
Show proper operation of emergency lights.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel showed operation and added photoluminescent signage.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 March 2018
Resolved
Mount COI and stability letters.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel posted required certificates.
Communications › Radio Communications › EPIRB
Issued 18 October 2017
Resolved
Provide serviceable EPIRB HRU
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2017
Resolution: New HRU installed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 18 October 2017
Resolved
Make permanent repairs to port side engine room vent
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 8 December 2017
Resolution: Vent properly repaired.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 October 2017
Resolved
Reconnect fuel shut-off valve
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2017
Resolved 18 October 2017
Resolution: Fuel rod was reconnected and valve operation verified by attending inspectors
Communications › Radio Communications › EPIRB
Issued 18 October 2017
Resolved
Provide valid EPIRB registration
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 8 December 2017
Resolution: Registration witnessed.
Engineering › Lubricating Oil Storage/Transfer System › Drain Tank
Issued 18 October 2017
Resolved
Remove excess oil from the vessel bilges
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 8 December 2017
Resolution: Excess oil removed from bilge.
Fire Fighting › Fire Pumps › Power Source
Issued 18 October 2017
Resolved
Show proper operation of fire pump and bilge pumps
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Resolution: Proper operation of fire/bilge pumps witnessed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 June 2017
Resolved
Work List: Provide battery box and cover for battery in engine room.
Action required: 705 - Other - as specified
Resolved 3 August 2017
Resolution: Battery box verified by BVI Shipping Resgistry Inspector.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 June 2017
Resolved
Repair lazarette ladder rungs.
Action required: 705 - Other - as specified
Resolved 3 August 2017
Resolution: Ladder rungs verified by BVI Shipping Resgistry Inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2017
Resolved
Cracks discovered in port strut, and salt deposit on interior of strut. Investigate extent of cracks and complete temporary repair.
Action required: 705 - Other - as specified
Resolved 3 August 2017
Resolution: Repairs verified by BVI Shipping Resgistry Inspector.
Engineering › Bilge Water Management System › Pump
Issued 10 March 2017
Resolved
remove bilge pump forward of collision bulkhead and cap off the penetration through the bulkhead
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 15 March 2017
Resolution: removed submersible bilge pump fwd of collision bulkhead and capped off penetration through the collision bulkhead
Engineering › Fuel Oil Service System › Vent Pipe
Issued 10 March 2017
Resolved
Weld fuel vent pipe IWO gooseneck
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 15 March 2017
Resolution: re-welded fuel vent pipe
Engineering › Bilge Water Management System › Piping
Issued 10 February 2016
Resolved
Remove flex hose outboard of insalled electrical bilge pump valves and fit up with hard pipe.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 28 March 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 10 February 2016
Resolved
Provide indicator for newly installed sewage tank indicating 3/4 level as required.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 28 March 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 February 2016
Resolved
Make repairs to wet exhaust piping where leaking into steering gear compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Engineering › Bilge Water Management System › Manifold
Issued 1 February 2016
Resolved
Make repairs to installed bilge piping manifold where holed and wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Resolution: Operator has installed electric submersibele pumps.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 February 2016
Resolved
Provide cover for electrical junction box in forward compartment.
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 10 February 2016
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 February 2016
Resolved
Repair engine room hatch where holed and make water tight.
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 10 February 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 July 2014
Resolved
Prove proper operation of stern light.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Lifesaving › Lifebuoys › Stowage
Issued 2 July 2014
Resolved
Replace ring bouy floating light mounting bracket.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 July 2014
Resolved
Provide & install fitting for Fuel Oil Remote Shutdown cable.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 July 2014
Resolved
Conduct twelve (12) year hydrostatic testing of fixed CO2 firefighting storage bottle.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 July 2014
Resolved 3 July 2014
Documentation › Safety/Response Plans/Programs › Search and Rescue Co-Op Plan
Issued 2 July 2014
Resolved
Provide approved SAR Co-Op Plan.
Action required: 705 - Other - as specified
Due 31 August 2014
Resolved 9 September 2014
Navigation › Piloting/Steering › Steering Magnetic Compass
Issued 2 July 2014
Resolved
Prove operation of compass light.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 July 2014
Resolved 3 July 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 July 2014
Resolved
Provide first aid kit as per 46 CFR 160.041.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 July 2014
Resolved 3 July 2014
Communications › Radio Communications › EPIRB
Issued 2 July 2014
Resolved
Provide current EPIRB registration.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Fire Fighting › Fire Main › Condition
Issued 2 July 2014
Resolved
Make permanent repairs to leaking fire main piping located in engine room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 July 2014
Resolved 3 July 2014
Fire Fighting › Fire Pumps › Arrangement
Issued 2 July 2014
Resolved
Tighten drive belts for belt-driven fire pump.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Fire Fighting › Fire Hoses › Condition
Issued 2 July 2014
Resolved
Mark vessel name on Fire Hose.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Construction/Loadline › Structures › Scuttle
Issued 26 June 2014
Resolved
Weld underside of all main deck scuttles.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 26 June 2014
Resolved
Provide and install ground conductor for fuel oil storage tank fill rubber hose.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 2 July 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 26 June 2014
Resolved
Provide and install insulation blankets for port and stbd main engine turbochargers.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 2 July 2014
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 November 2008
Resolved
Provide proof of new operating company listed on drug and alcohol program.
Due 15 January 2009
Resolved 8 July 2009
Resolution: Item was not corrected however COI was deactviated due to company going bankrupt.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 November 2008
Resolved
Secure wiring in mid void.
Due 15 December 2008
Resolved 1 July 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 26 November 2008
Resolved
Intall proper fire extiguisher bracket
Due 15 December 2008
Resolved 1 July 2009
Documentation › Certificates/Documents › FCC SSL
Issued 26 November 2008
Resolved
Provide proof fo FCC SSL
Due 15 December 2008
Resolved 8 July 2009
Resolution: Item was not corrected however COI was deactviated due to company going bankrupt. New owner will need full COI.
Fire Fighting › Fire Pumps › Pressure
Issued 26 November 2008
Resolved
Install pressure gauge on discharge side of fire pump
Due 2 January 2009
Resolved 1 July 2009
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 26 November 2008
Resolved
Replace cracked window in accomidation space.
Due 1 July 2009
Resolved 1 July 2009
Construction/Loadline › Hull › Hull Plating
Issued 21 November 2007
Resolved
Make vsl available for a credited hull and ISE exam.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2008
Resolution: Completed credit hull exam
Documentation › Certificates/Documents › FCC SSL
Issued 12 September 2005
Resolved
Update FCC license with the current vessel owners
Due 21 September 2005
Resolved 26 October 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 September 2005
Resolved
Label PFD locker with number and adult or children
Due 21 September 2005
Resolved 26 October 2005
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 September 2005
Resolved
Mark emergency exit
Due 21 September 2005
Resolved 26 October 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 September 2005
Resolved
Obtain tide tables/current charts
Due 21 September 2005
Resolved 26 October 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 September 2005
Resolved
Obtain valid Coast Pilot
Due 21 September 2005
Resolved 26 October 2005
Electrical › Electric Supply System (service) › Cable
Issued 12 September 2005
Resolved
Replace GPS wiring in Pilot House
Due 21 September 2005
Resolved 26 October 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 September 2005
Resolved
Mount PFD donning placard
Due 21 September 2005
Resolved 26 October 2005
Construction/Loadline › Penetrations › Gasket
Issued 12 September 2005
Resolved
Renew gasket on aft steering hatch
Due 21 September 2005
Resolved 26 October 2005
Engineering › Lubricating Oil Service System › Flange
Issued 12 September 2005
Resolved
Remove hydraulic oil from aft steering area.
Due 21 September 2005
Resolved 26 October 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 September 2005
Resolved
Renew leaking water piping for MSD in Aft steering compartment.
Due 21 September 2005
Resolved 26 October 2005
Lifesaving › Hand Flares › Expired
Issued 1 September 2004
Resolved
Replaced expired hand flares.
Condition: Unknown
Due 1 October 2004
Resolved 27 September 2004
Resolution: Replaced Flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 September 2004
Resolved
Replace expired medicines in first aid kit.
Due 1 October 2004
Resolved 5 September 2004
Engineering › Bilge Water Management System › Pump
Issued 1 September 2004
Resolved
Relocate lazerette bilge pump switch.
Condition: Unknown
Due 1 October 2004
Resolved 5 September 2004
Resolution: Relocated bilge alarm switch
Communications › Audible Communications › SPD (Other)
Issued 1 September 2004
Resolved
Repair as original Public address system.
Due 1 October 2004
Resolved 27 September 2004
Fire Fighting
Issued 20 June 2001
Resolved
Service fixed and portable fire extinguishers IAW 46 CFR 176.810. Item to be completed prior to operating with passengers.
Condition: Unknown
Due 27 June 2001
Resolved 2 July 2001
Construction/Loadline
Issued 20 June 2001
Resolved
Repair installed bilge high level alarms make operational to 46 CFR 182.530Item to be completed prior to operating with passengers.
Condition: Unknown
Due 27 June 2001
Resolved 2 July 2001
Electrical
Issued 20 June 2001
Resolved
Make emergency lighting operational IAW 46 CFR 183.432. Item to be completed prior to operating with passengers.
Condition: Unknown
Due 27 June 2001
Resolved 2 July 2001
Lifesaving
Issued 20 June 2000
Resolved
provide Life jacket donning placard as required in 46 CFR 185.516
Condition: Unknown
Due 20 July 2000
Resolved 23 June 2000
Electrical
Issued 17 May 1999
Resolved
Ensure proper operation of emergency light outside in passageway outside head space below decks, prior to carring passengers.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Electrical
Issued 17 May 1999
Resolved
Provide second operational portable light as per 46 CFR 183.432 within 30 days.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Navigation
Issued 17 May 1999
Resolved
Provide on board current and corrected charts of the area of operation prior to operating with passengers.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999
Resolved
Provide in date signal flares as required by 46 CFR 180.68 (three day / three night flares) prior to operating with passengers.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999
Resolved
Update battery and hytrostatic release for EPIRB with 30 days.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Documentation
Issued 17 May 1999
Resolved
Document crew training as per 46 CFR 185.420 and provide copy of same withing 60 days.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Documentation
Issued 17 May 1999
Resolved
Provide proof of drug testing program in accordance with 46 CFR part 16.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Documentation
Issued 17 May 1999
Resolved
Stability letter not poted. Post Stability letter in pilot house within_x001C_ 30 days.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999
Resolved
Crew not present. Conduct emergency drills with the crew in the pressence of a Coast Guard marine inspector.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Engineering
Issued 21 July 1998
Resolved
MAKE OPERATIONAL EMERGENCY FUEL SHUT OFF, ENSURING VALVE_x001C_ CLOSES IN THE FULL OFF POSITION.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 21 July 1998
Resolved
RENEW PRESSURE GAGE ON ENGINE DRIVEN FIRE PUMP.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Lifesaving
Issued 21 July 1998
Resolved
ATTACH RETRO-REFLECTIVE TAPE TO CHILD SIZE PFD'S
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Deck/Cargo
Issued 26 June 1997
Resolved
RIG PORT AND STBD ANCHORS FOR DEPLOYMENT WITH LINE AND SHACKLES.
Condition: Unknown
Due 6 July 1997
Resolved 24 September 1997
Lifesaving
Issued 26 June 1997
Resolved
MAKE FLOAT LIGHT ON STBD LIFERING OPERATIONAL
Condition: Unknown
Due 6 July 1997
Resolved 24 September 1997
Lifesaving
Issued 26 June 1997
Resolved
INSTALL RETRO-REFLECTIVE TAPE ON ALL LIFERINGS.
Condition: Unknown
Due 6 July 1997
Resolved 24 September 1997
Documentation
Issued 20 August 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996