D III is a 1996 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1996, most recently in September 2025, along with 163 deficiencies — 1 with no resolution recorded —, 2 operational controls, 1 with no removal date recorded and 1 casualty investigation in 2008.

Records from 1996 to 2025. Most recent: inspection, 21 September 2025.

Built
1996
Last inspected
21 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

ZJL8562
441233
Flag
VIRGIN ISLANDS, BRITISH
367069010 (licence lapsed)
Maury page id
psix-441233

Inspections, by type

…with no type recorded8
…past their stated due date1
Years with a record 21 calendar years (1996–2025)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it24 - Simplified, Gross Ton
24 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC7280MMSI 367069010 · expired · compulsorily equipped · granted 28 September 2005, cancelled 28 November 2015
WCW9293MMSI not assigned · expired · voluntarily equipped · granted 30 October 1996, cancelled 30 December 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

M/V ADVENTURER Passenger (Inspected) · MISLE 52790 · 23 August 2018 · activity 6521747

Inspection history · 53

21 September 2025 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8238824
18 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8190453
24 June 2025 MTSA/ISPS Verification · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8165979
23 April 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam · COE-Administrative
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8130712
27 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8070241
15 April 2024 Administrative Inspection · DAPI Audit · Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7895352
4 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7863485
4 November 2022 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7589341
1 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7522131
24 February 2022 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7398108
5 February 2022 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7392388
25 August 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7312037
18 July 2019 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6781076
2 April 2019 ISPS III Exam · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6654584
29 January 2019 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6616514
14 January 2019 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6607108
4 December 2018 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6592151
23 August 2018 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6521747
28 June 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6459492
29 March 2018 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6381703
27 March 2018 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6379496
8 March 2018 ISPS II Exam · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6365757
18 October 2017 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6291541
27 June 2017 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6182124
9 January 2017 COI Inspection · DAPI Audit · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6089371
28 January 2016 COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5805220
26 June 2014 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4972020
16 June 2014 ISPS II Exam · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4890157
26 November 2008 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3369850
10 July 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3263671
29 November 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3106500
28 November 2007 Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3104378
25 September 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2786369
12 September 2005 Simplified Stability Test · Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2497643
20 July 2005 Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2440173
18 June 2004 Hull Examination · Annual Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2102419
15 August 2002 Annual Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1660221
20 June 2001 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1425188
18 August 2000 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 11451
20 June 2000 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 818817
29 July 1999 Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1107707
22 July 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 168410
12 June 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 90431
20 May 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 719084
17 May 1999 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1416884
8 October 1998 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 166720
31 July 1998 Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1131247
21 July 1998 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 794830
22 June 1998 Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 793642
26 June 1997 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 776823
21 November 1996 Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1178734
12 November 1996 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1184657
20 August 1996 Hull Examination · Initial Certification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1357692

Deficiency record · 163

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 September 2025 No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. A report was received that D III was partially submerged in Road Town, Tortola. MI contacted vsl owner; Owner stated the rudder was removed in order to change props and the vessel took on water. A damage survey and written report shall be provided in writing by a qualified marine surveyor. The survey shall include a full assessment of the vessels structure, all equipment, and overall condition of seaworthiness. A root cause and analysis shall be provided in writing to MSU St. Thomas for review. A determination of casual factors shall be provided and all steps taken to safely recover the vessel. Owner shall provide a detailed and written repair plan and submit to Marine Safety Unit St. Thomas for review. Once the repair plan has been reviewed, a response will be provided to the owner prior to commencing repairs. All Repairs and/or alterations will need to be reviewed prior to commencing and will require Coast Guard oversight throughout process. All above mentioned requirements shall be met to the satisfaction of Marine Safety Unit St. Thomas prior to operating commercially in USVI waters. D III is required to conduct a USCG COI inspection prior to continuing operations in USVI waters. In addition, a drydock inspection may be required. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2025 Resolved
If your vessel is operated on international voyages..... it must undergo a drydock examination once every 12 months. D III did not conduct yearly drydock inspection as indicated on USCG COI. Coordinate with USCG for scheduling for drydock inspection and provide intentions for operating in USVI prior to carrying passengers in USVI. 46 CFR 176.600(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2025
Resolved 23 April 2025
Resolution: Vessel underwent satisfactory drydock & internal structural exam.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Main passenger cabin deck plating was not secured and provided open access to engine room which is protected with CO2. Multiple areas of the engine room allowed the passage of vapors. Provide repair plan for securing deck plating and making engine room vapor tight. Submit repair plan for approval prior conducting repairs. Make engine room vapor tight as original.
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 27 June 2024
Resolution: met requirment
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jacket stowage was not seperate from adults. Stow child life jacket seperately and label prior to COI issuance. 46 CFR 180.78(a)(5)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Stbd ER battery bank and wiring was found wasted; replace battery and install battery wiring as required prior to COI issuance. 46 CFR 183.200 (b)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024 Resolved
All engines must be water cooled and meet the requirements of this paragraph.A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. ME (port) raw water strainer housing was found without strainer, replace as required prior to COI issuance. 46 CFR 182.420 (a)(2) 46 CFR 182.100
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Bother caps on raw water strainers were found with temp repairs and broken, replace as required 46 CFR 182.100
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024 Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. ER access hatch insulation was removed; replace as required 46 CFR 177.410(c)(4)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Steering linkage bolts were inverted, rearrange linkage bolts 46 CFR 182.100
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 April 2024 Resolved
Shall be provided with individual bigle lines and suctions for each water tight compartment. Aft steering bilge system float switch was broken and ovbd discharge was not properly configured 46 CFR 182.25-5(a)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024 Resolved
Shut off valve at the tank shall be operable from outside the tank compartment. Emergency Fuel COV was not operable and linkage was wasted, make COV operable and replace fasteners. Also secure pull handle closure box and label. 46 CFR 182.20-40(b)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 April 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. MI discovered daylight from multiple areas on main deck to aft steering. Make permanent repairs to deck plating. 46 CFR 177.100
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024 Resolved
All fuel tanks shall be electrically bonded to the common ground. Vsl rep did not know which fuel tank piping was for vent or fill. Electrical bonding was not installed; install bonding on fill side. 46 CFR 182.20-25(b)(4)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024 Resolved
Filling and sounding pipes shall be so arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. Wasted piping was discovered above fuel tank on fill/vent. Replace fuel tank piping in corroded sections. 46 CFR 182.20-30(b)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 April 2024 Resolved
The general construction shall be such as to minimize fire hazarards. Seal bulkhead penetrations in ER protected with CO2 46 CFR 177.10-5(a)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024 Resolved
All electrical installations shall be to the satisfaction of the OCMI, Marine Inspections. Electrical junction box in aft steering and ER was not sealed; seal as required 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 April 2024 Resolved
All watertight doors in subdivision bulkheads must be kept tightly closed during the navigation of the vessel except when being used for transit between compartments. Aft steering water tight hatch gasket is wasted; replace gasket 46 CFR 185.330(b)
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 April 2024 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. MOB drill: Effective communication was lacking, and boat hook was not on board. Crew was not competent with drill. Run drill again and demonstrate crew proficiency. 46 CFR 185.520(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2024
Resolved 27 June 2024
Resolution: met requirment
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2024 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Covered employee list from 2022. Provide current covered employee list. 46 CFR 16.210
Action required: 705 - Other - as specified
Due 27 June 2024
Resolved 27 June 2024
Resolution: met requirment
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2024 Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall inspect all lifesaving equipment to determine its serviceability. Port and starboard liferaft cradle lashing pelican hooks found loose and unsecured. Properly secure liferafts to the cradles in accordance with manufacturers instructions.
Action required: 705 - Other - as specified
Due 27 June 2024
Resolved 27 June 2024
Resolution: met requirment
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical smoke was observed. Provide technical report and diagnosis for approval in addition to making necessary repairs of electrical system.
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 27 June 2024
Resolution: met requirment
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 15 April 2024 Resolved
he construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. MI discovered passenger gangway access door secured with bailing wire. Make repairs IAW original design.
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 27 June 2024
Resolution: met requirment
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 April 2024 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended. Electrical wiring and steering hoses below operating station covered in hydraulic fluid. Clean all affected wires, cables, and hoses for USCG reinspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2024
Resolved 27 June 2024
Resolution: met requirment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2022 Resolved
Bilge and drainage systems. The means provided for pumping bilges shall be tested by operation. Attending MI's were unable to test bilge suction in after steering due to oily bilge conditions. Also did not function correctly in FWD lower compartment.46CFR176.25-1 (b)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 4 November 2022 Resolved
The fire pump shall be tested and the fire hose shall be subjected to the available fire pump pressure. The fire pump was inoperable during USCG Inspection.46CFR176.25-25
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 November 2022 Resolved
Re-inspection conducted of lifesaving equipment shall be made as deemed necessary by the Officer in Charge of marine inspection. Attending MI's noted that the IBA's listed on vessels BVI and USCG COI's have been replaced by life floats.46CFR176.25-22
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 November 2022 Resolved
At each inspection for certification and re inspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Attending MI's noted excessive oil in the engine room and steering compartment bilges. 46CFR176.25-50(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 November 2022 Resolved
Electrical equipment shall be reasonably safe from electrical shock of personal. The breaker panel which contains the fire pump breaker has loose and missing a cover. 46CFR183.01-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 November 2022 Resolved
Fire hose length shall be not less than 25 feet and not more than 50 feet. Attending MI’s noted that he fire hoses on board were 100 feet in length which will reduce their effectiveness in an emergency. 46CFR181.15-10 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 November 2022 Resolved
Fuel systems installed shall be checked and tested by operation locally and at remote locations. Attending MI's noted that the fuel shut off valve was inaccessible and not conducive to easy rapid closing of the fuel.46CFR176.25(5)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 4 November 2022 Resolved
Flexible or portable cords such as SO, STO and similar types cannot be used for permanently installed wiring. Attending MI's noted a wired plug over the sink. 46CFR183.10-10(c)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 4 November 2022 Resolved
Suitable covers, guards or rails shall be installed in a way of all exposed and hazardous places such as gears and machinery. The installed generator guard is insufficient to protect crew.46CFR177.35-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 November 2022 Resolved
Deck Rails shall be installed near the periphery of all weather decks accessible to passengers and crew. Attending MI's noted that the after most port handrail was loose and easily pushed out with minimal force. 46CFR177.35(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 November 2022 Resolved
Battery connections shall be made to the battery terminals with permanent type connections. Spring clips or other temporary type clams are not permitted. Attending MI's noted that numerous battery terminals of the temporary type. 46CFR183.05-20(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 4 November 2022 Resolved
All wires shall terminate in a junction box. MI's noted open wires top of open deck, lower forward compartment and in the engine room. All dead ended or unused wires shall be terminated in a junction box. 46CFR183.10-20 46CFR183.10-20
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2022 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas or liquid the temperature of which exceeds 150F, must be suitably insulated where necessary to prevent injuries. Attending MI's noted that the exhaust manifold expansion joints before the water inlet were uninsulated. 46CFR177-970, 46CFR182.20-20
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2022 Resolved
Vessel shall be inspected for compliance with standards required by this sub chapter. Jacket water piping for both main engines is being held in place with plastic wire ties as opposed to permeate pipe hangers. 46CFR176.25
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 November 2022 Resolved
Escape hatch located under operating station console blocked by storage items. Remove all storage items blocking hatch. 46 CFR 185.310-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2022 Resolved
C02 fixed firefighting system activation pull station at the operating station not marked. 46 CFR 181.20-15(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2022 Resolved
C02 fixed firefighting system activation pull station does not have operating instructions. 46 CFR 181.20-15(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2022 Resolved
Provide C02 fixed firefighting system servicing report for inspection. 46 CFR 176.25-25(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 November 2022 Resolved
All electrical cables and wiring in the engine room are suspended by plastic zip ties. Wiring and cables must be suspended by metal supports not more than 24” apart in a manner to avoid chaffing. 46 CFR 183.340(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 4 November 2022 Resolved
Metal Sheaving & insulation needs replacement Eng. Room 46CFR176.25
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: 12 December 2022, conducted a def follow up and all deficiencies have been resolved and verified by the attending marine inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 August 2022 Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. If your vessel is operated on international voyages subject to SOLAS requirements, it must undergo a drydock examination once every 12 months unless it has been approved to undergo an underwater survey (UWILD) per § 176.615 of this part. Operator failed to complete required drydock by inspection date listed on COI of 31July2022.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2022
Resolved 7 December 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 24 February 2022 Resolved
Provide proof of DAPI compliance of a chemical testing program for the crew and current enrollment list.
Action required: 705 - Other - as specified
Resolved 2 March 2022
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 24 February 2022 Resolved
Post Stability Letter and COI outside the operating station where passengers can view them.
Action required: 705 - Other - as specified
Resolved 2 March 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 February 2022 Resolved
EPIRB battery & hydrostatic release unit expired.
Action required: 705 - Other - as specified
Resolved 2 March 2022
Resolution: New EPIRB purchased
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2022 Resolved
Aft Life Ring out of service
Action required: 705 - Other - as specified
Resolved 2 March 2022
Resolution: New lifering provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022 Resolved
Properly wire aft door lighting into an electrical box.
Action required: 705 - Other - as specified
Resolved 2 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022 Resolved
Remove portable pump plugged into aft door outlet.
Action required: 705 - Other - as specified
Resolved 2 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022 Resolved
Provide light fixture on stbd side near aft door.
Action required: 705 - Other - as specified
Resolved 2 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2022 Resolved
Properly mark fuel shut-off valve.
Action required: 705 - Other - as specified
Resolved 2 March 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 July 2019 Resolved
Controls and valves for operation of fixed gas fire extinguishing system must be located outside of the space protected by the system. The D III fixed fire extinguishing system control valves are located in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 1 October 2019
Resolution: Controls were moved to the compartment forward of the engine room. outside of the protected space.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 April 2019 Resolved
Provide a fire detection system or a fixed gas system capable of automatic activation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2019
Resolution: Fire system has heat activated automatic discharge installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 April 2019 Resolved
Conduct man overboard and fire drill.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2019
Resolution: Witnessed drills
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 April 2019 Resolved
Provide proof of enrollement in DAPI consortium.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2019
Resolution: Witnessed proof of enrollment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2019 Resolved
Separate child's lifejackets from adults.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2019
Resolution: Lifejackets seperated.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2019 Resolved
Post stability letter in wheel house.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 April 2019
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance (DoC/ ISM)
Issued 2 April 2019 Resolved
Provide current BVI issued DOC.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2019
Resolution: Provided.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 2 April 2019 Resolved
Prove proper operation of public address system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2019
Resolution: Witnessed proper operation.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 December 2018 Resolved
Due to steering casualty, make vessel available for dry dock exam by attending USCG Marine Inspector. All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Vessel made available for drydock inspection by attending USCG marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 December 2018 Resolved
Identify source of water ingress in way of port side transom lazarette & provide repair proposal. All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Vessel made repairs following identification of a crack in the port strut allowing propogation into lazarette. Repairs overseen by BVI VISR.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 4 December 2018 Resolved
Identify source of dirty oil in lazarette. All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Oil propogated through old through bulkhead fitting that was not properly secured. Vessel secured and stopped movement of liquid.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 4 December 2018 Resolved
Remove all oil and oily residues in lazarette and engine room. All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Oil and residues removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018 Resolved
Provide manufacturers instructions for drip-less shaft seals. All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Manufacturers instructions provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2018 Resolved
Properly secure deck plates in main cabin. All vessel movements to be approved by the USCG prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Deckplates secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018 Resolved
Make permanent repairs or replace leaking shaft seal oil reservoirs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Leaks secured.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2018 Resolved
Provide deck rails atleast 39.5" tall with rail courses atleast every 4 inches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2018
Resolved 29 January 2019
Resolution: Vessel sent pictures showing installation of grating that meets course requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018 Resolved
Replace starboard shaft seal.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Starboard shaft seal replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018 Resolved
Replace starboard steering tiller.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: Tiller replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2018 Resolved
Provide survey report from Virgin Islands [name withheld] attesting to proper repairs to both shaft struts and bottom plate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 January 2019
Resolution: VISR report showing deficiencies and dates cleared provided.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 June 2018 Resolved
Crop and renew inset on starboard side shell below pilot house in way of chine.
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 2 July 2018
Resolution: Area cropped and renewed with no CG oversight.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 June 2018 Resolved
Make connection between sea valve and through hull fitting for generator raw water cooling with metallic piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2018
Resolution: Sea valve threaded to through hull fitting.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 March 2018 Resolved
Provide records for servicing of fixed firefighting (CO2) system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2018
Resolution: Vessel provided servicing report.
Communications › Radio Communications › EPIRB
Issued 8 March 2018 Resolved
Mount EPIRB to facilitate float free release.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: EPIRB mounted properly.
Lifesaving › Lifefloat › Float-free Link
Issued 8 March 2018 Resolved
Provide weak link for life float.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Lifelfoat weak link provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 8 March 2018 Resolved
Provide instructions for CO2 system.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel posted instructions for CO2 system.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 March 2018 Resolved
Mount and protect ship service circuit breaker.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel mounted circuit breaker.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 8 March 2018 Resolved
Provide servicing certificate for IBA
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Servicing certificate provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 March 2018 Resolved
Provide generator fan belt guard.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Fan belt guard provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 March 2018 Resolved
Provide DSC Radio with MMSI and GOS input
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel replaced DSC VHF with compliant one.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 March 2018 Resolved
Mount lazarett bilge alarm.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel mounted bilge alarm.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 March 2018 Resolved
Provide lid for generator start batteries.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel provided battery box cover.
Engineering › Bilge Water Management System › Pump
Issued 8 March 2018 Resolved
Provide suitable emergency/hand bilge pump.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Hand bilge pump provided with long enough hose.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 March 2018 Resolved
Secure stern bench seat in place.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Bench seat secured.
Lifesaving › Lifefloat › Markings
Issued 8 March 2018 Resolved
Mark vessel name on life float.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Vessel name marked.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 March 2018 Resolved
MArk vessel noame on ring buoy.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Vessel name marked.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 March 2018 Resolved
Provide lanyard and clip for life buoy.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Lanyard and clip provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 March 2018 Resolved
Attach buoyant lifeline around body of life buoy.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 March 2018
Resolution: Lifeline attached.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 March 2018 Resolved
Show proper operation of emergency lights.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel showed operation and added photoluminescent signage.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 March 2018 Resolved
Mount COI and stability letters.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 29 March 2018
Resolution: Vessel posted required certificates.
Communications › Radio Communications › EPIRB
Issued 18 October 2017 Resolved
Provide serviceable EPIRB HRU
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2017
Resolution: New HRU installed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 18 October 2017 Resolved
Make permanent repairs to port side engine room vent
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 8 December 2017
Resolution: Vent properly repaired.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 October 2017 Resolved
Reconnect fuel shut-off valve
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2017
Resolved 18 October 2017
Resolution: Fuel rod was reconnected and valve operation verified by attending inspectors
Communications › Radio Communications › EPIRB
Issued 18 October 2017 Resolved
Provide valid EPIRB registration
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 8 December 2017
Resolution: Registration witnessed.
Engineering › Lubricating Oil Storage/Transfer System › Drain Tank
Issued 18 October 2017 Resolved
Remove excess oil from the vessel bilges
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 8 December 2017
Resolution: Excess oil removed from bilge.
Fire Fighting › Fire Pumps › Power Source
Issued 18 October 2017 Resolved
Show proper operation of fire pump and bilge pumps
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Resolution: Proper operation of fire/bilge pumps witnessed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 June 2017 Resolved
Work List: Provide battery box and cover for battery in engine room.
Action required: 705 - Other - as specified
Resolved 3 August 2017
Resolution: Battery box verified by BVI Shipping Resgistry Inspector.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 June 2017 Resolved
Repair lazarette ladder rungs.
Action required: 705 - Other - as specified
Resolved 3 August 2017
Resolution: Ladder rungs verified by BVI Shipping Resgistry Inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2017 Resolved
Cracks discovered in port strut, and salt deposit on interior of strut. Investigate extent of cracks and complete temporary repair.
Action required: 705 - Other - as specified
Resolved 3 August 2017
Resolution: Repairs verified by BVI Shipping Resgistry Inspector.
Engineering › Bilge Water Management System › Pump
Issued 10 March 2017 Resolved
remove bilge pump forward of collision bulkhead and cap off the penetration through the bulkhead
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 15 March 2017
Resolution: removed submersible bilge pump fwd of collision bulkhead and capped off penetration through the collision bulkhead
Engineering › Fuel Oil Service System › Vent Pipe
Issued 10 March 2017 Resolved
Weld fuel vent pipe IWO gooseneck
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 15 March 2017
Resolution: re-welded fuel vent pipe
Engineering › Bilge Water Management System › Piping
Issued 10 February 2016 Resolved
Remove flex hose outboard of insalled electrical bilge pump valves and fit up with hard pipe.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 28 March 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 10 February 2016 Resolved
Provide indicator for newly installed sewage tank indicating 3/4 level as required.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 28 March 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 February 2016 Resolved
Make repairs to wet exhaust piping where leaking into steering gear compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Engineering › Bilge Water Management System › Manifold
Issued 1 February 2016 Resolved
Make repairs to installed bilge piping manifold where holed and wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Resolution: Operator has installed electric submersibele pumps.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 February 2016 Resolved
Provide cover for electrical junction box in forward compartment.
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 10 February 2016
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 February 2016 Resolved
Repair engine room hatch where holed and make water tight.
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 10 February 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 July 2014 Resolved
Prove proper operation of stern light.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Lifesaving › Lifebuoys › Stowage
Issued 2 July 2014 Resolved
Replace ring bouy floating light mounting bracket.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 July 2014 Resolved
Provide & install fitting for Fuel Oil Remote Shutdown cable.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 July 2014 Resolved
Conduct twelve (12) year hydrostatic testing of fixed CO2 firefighting storage bottle.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 July 2014
Resolved 3 July 2014
Documentation › Safety/Response Plans/Programs › Search and Rescue Co-Op Plan
Issued 2 July 2014 Resolved
Provide approved SAR Co-Op Plan.
Action required: 705 - Other - as specified
Due 31 August 2014
Resolved 9 September 2014
Navigation › Piloting/Steering › Steering Magnetic Compass
Issued 2 July 2014 Resolved
Prove operation of compass light.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 July 2014
Resolved 3 July 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 July 2014 Resolved
Provide first aid kit as per 46 CFR 160.041.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 July 2014
Resolved 3 July 2014
Communications › Radio Communications › EPIRB
Issued 2 July 2014 Resolved
Provide current EPIRB registration.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Fire Fighting › Fire Main › Condition
Issued 2 July 2014 Resolved
Make permanent repairs to leaking fire main piping located in engine room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 July 2014
Resolved 3 July 2014
Fire Fighting › Fire Pumps › Arrangement
Issued 2 July 2014 Resolved
Tighten drive belts for belt-driven fire pump.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Fire Fighting › Fire Hoses › Condition
Issued 2 July 2014 Resolved
Mark vessel name on Fire Hose.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 3 July 2014
Construction/Loadline › Structures › Scuttle
Issued 26 June 2014 Resolved
Weld underside of all main deck scuttles.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 26 June 2014 Resolved
Provide and install ground conductor for fuel oil storage tank fill rubber hose.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 2 July 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 26 June 2014 Resolved
Provide and install insulation blankets for port and stbd main engine turbochargers.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 2 July 2014
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 November 2008 Resolved
Provide proof of new operating company listed on drug and alcohol program.
Due 15 January 2009
Resolved 8 July 2009
Resolution: Item was not corrected however COI was deactviated due to company going bankrupt.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 November 2008 Resolved
Secure wiring in mid void.
Due 15 December 2008
Resolved 1 July 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 26 November 2008 Resolved
Intall proper fire extiguisher bracket
Due 15 December 2008
Resolved 1 July 2009
Documentation › Certificates/Documents › FCC SSL
Issued 26 November 2008 Resolved
Provide proof fo FCC SSL
Due 15 December 2008
Resolved 8 July 2009
Resolution: Item was not corrected however COI was deactviated due to company going bankrupt. New owner will need full COI.
Fire Fighting › Fire Pumps › Pressure
Issued 26 November 2008 Resolved
Install pressure gauge on discharge side of fire pump
Due 2 January 2009
Resolved 1 July 2009
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 26 November 2008 Resolved
Replace cracked window in accomidation space.
Due 1 July 2009
Resolved 1 July 2009
Construction/Loadline › Hull › Hull Plating
Issued 21 November 2007 Resolved
Make vsl available for a credited hull and ISE exam.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2008
Resolution: Completed credit hull exam
Documentation › Certificates/Documents › FCC SSL
Issued 12 September 2005 Resolved
Update FCC license with the current vessel owners
Due 21 September 2005
Resolved 26 October 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 September 2005 Resolved
Label PFD locker with number and adult or children
Due 21 September 2005
Resolved 26 October 2005
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 September 2005 Resolved
Mark emergency exit
Due 21 September 2005
Resolved 26 October 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 September 2005 Resolved
Obtain tide tables/current charts
Due 21 September 2005
Resolved 26 October 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 September 2005 Resolved
Obtain valid Coast Pilot
Due 21 September 2005
Resolved 26 October 2005
Electrical › Electric Supply System (service) › Cable
Issued 12 September 2005 Resolved
Replace GPS wiring in Pilot House
Due 21 September 2005
Resolved 26 October 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 September 2005 Resolved
Mount PFD donning placard
Due 21 September 2005
Resolved 26 October 2005
Construction/Loadline › Penetrations › Gasket
Issued 12 September 2005 Resolved
Renew gasket on aft steering hatch
Due 21 September 2005
Resolved 26 October 2005
Engineering › Lubricating Oil Service System › Flange
Issued 12 September 2005 Resolved
Remove hydraulic oil from aft steering area.
Due 21 September 2005
Resolved 26 October 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 September 2005 Resolved
Renew leaking water piping for MSD in Aft steering compartment.
Due 21 September 2005
Resolved 26 October 2005
Lifesaving › Hand Flares › Expired
Issued 1 September 2004 Resolved
Replaced expired hand flares.
Condition: Unknown
Due 1 October 2004
Resolved 27 September 2004
Resolution: Replaced Flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 September 2004 Resolved
Replace expired medicines in first aid kit.
Due 1 October 2004
Resolved 5 September 2004
Engineering › Bilge Water Management System › Pump
Issued 1 September 2004 Resolved
Relocate lazerette bilge pump switch.
Condition: Unknown
Due 1 October 2004
Resolved 5 September 2004
Resolution: Relocated bilge alarm switch
Communications › Audible Communications › SPD (Other)
Issued 1 September 2004 Resolved
Repair as original Public address system.
Due 1 October 2004
Resolved 27 September 2004
Fire Fighting
Issued 20 June 2001 Resolved
Service fixed and portable fire extinguishers IAW 46 CFR 176.810. Item to be completed prior to operating with passengers.
Condition: Unknown
Due 27 June 2001
Resolved 2 July 2001
Construction/Loadline
Issued 20 June 2001 Resolved
Repair installed bilge high level alarms make operational to 46 CFR 182.530Item to be completed prior to operating with passengers.
Condition: Unknown
Due 27 June 2001
Resolved 2 July 2001
Electrical
Issued 20 June 2001 Resolved
Make emergency lighting operational IAW 46 CFR 183.432. Item to be completed prior to operating with passengers.
Condition: Unknown
Due 27 June 2001
Resolved 2 July 2001
Lifesaving
Issued 20 June 2000 Resolved
provide Life jacket donning placard as required in 46 CFR 185.516
Condition: Unknown
Due 20 July 2000
Resolved 23 June 2000
Electrical
Issued 17 May 1999 Resolved
Ensure proper operation of emergency light outside in passageway outside head space below decks, prior to carring passengers.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Electrical
Issued 17 May 1999 Resolved
Provide second operational portable light as per 46 CFR 183.432 within 30 days.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Navigation
Issued 17 May 1999 Resolved
Provide on board current and corrected charts of the area of operation prior to operating with passengers.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999 Resolved
Provide in date signal flares as required by 46 CFR 180.68 (three day / three night flares) prior to operating with passengers.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999 Resolved
Update battery and hytrostatic release for EPIRB with 30 days.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Documentation
Issued 17 May 1999 Resolved
Document crew training as per 46 CFR 185.420 and provide copy of same withing 60 days.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Documentation
Issued 17 May 1999 Resolved
Provide proof of drug testing program in accordance with 46 CFR part 16.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Documentation
Issued 17 May 1999 Resolved
Stability letter not poted. Post Stability letter in pilot house within_x001C_ 30 days.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999 Resolved
Crew not present. Conduct emergency drills with the crew in the pressence of a Coast Guard marine inspector.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Engineering
Issued 21 July 1998 Resolved
MAKE OPERATIONAL EMERGENCY FUEL SHUT OFF, ENSURING VALVE_x001C_ CLOSES IN THE FULL OFF POSITION.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 21 July 1998 Resolved
RENEW PRESSURE GAGE ON ENGINE DRIVEN FIRE PUMP.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Lifesaving
Issued 21 July 1998 Resolved
ATTACH RETRO-REFLECTIVE TAPE TO CHILD SIZE PFD'S
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Deck/Cargo
Issued 26 June 1997 Resolved
RIG PORT AND STBD ANCHORS FOR DEPLOYMENT WITH LINE AND SHACKLES.
Condition: Unknown
Due 6 July 1997
Resolved 24 September 1997
Lifesaving
Issued 26 June 1997 Resolved
MAKE FLOAT LIGHT ON STBD LIFERING OPERATIONAL
Condition: Unknown
Due 6 July 1997
Resolved 24 September 1997
Lifesaving
Issued 26 June 1997 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON ALL LIFERINGS.
Condition: Unknown
Due 6 July 1997
Resolved 24 September 1997
Documentation
Issued 20 August 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996

Casualty record · 1

10 July 2008Routine · role: Involved in a Marine Casualty · activity 3263671
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DAUFUSKIE ISLAND III (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.