MAURY USCG vessel records
← All vessels

SEAHORSE

Built
1961
Last inspected
24 November 2024
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 24 November 2024
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 18 calendar years (1985–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
1598 - Convention (Subpart B), Gross Ton 479 - Convention (Subpart B), Net Ton
Maury page id
psix-44139
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

SEANA C Towing Vessel · MISLE 433109 · 24 November 2024 · activity 8047251TERRI L. BRUSCO Towing Vessel · MISLE 86976 · 1 December 1999 · activity 49566

Inspection history · 43

24 November 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8047251
10 January 2019 Load Line/Change of Employment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6607554
8 March 2018 Load Line/Change of Employment
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6372053
26 August 2014 Internal Structural Exam · Load Line/Change of Employment · Administrative Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4968884
1 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 49566
25 January 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1123003
13 May 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1103940
28 May 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1085123
20 March 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1078699
7 March 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1390210
1 February 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 871409
3 January 1996 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1359023
21 August 1995 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 871853
23 February 1995 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1428442
21 October 1994 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 862158
23 March 1994 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382735
9 February 1994 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1467403
6 December 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1444770
16 March 1992 Permit to Proceed
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379682
24 May 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 901795
12 March 1991 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 906904
12 March 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1219418
10 July 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1243330
9 July 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1240777
8 May 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1221690
20 February 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 902779
26 January 1990 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1216352
20 December 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 923968
28 November 1989 Deadweight Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1234295
2 November 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1002063
6 December 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 897405
6 May 1988 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1037517
13 November 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1024564
9 December 1986 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1007638
1 December 1986 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1018877
19 September 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 517877
1 April 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 996859
11 December 1985 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 997169
5 November 1985 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 986191
30 October 1985 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1295088
16 May 1985 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 986459
10 May 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 986030
12 January 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 482785

Deficiency record · 32

Unknown
Issued 3 January 1996 Resolved
Re-paint the name and hailing port on the stern to make them legible. Accomplish to the satisfaction of the cognizant OCMI prior to 04FEB96.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Electrical
Issued 3 January 1996 Resolved
Provide a suitable and secure mounting arrangement for the deck machinery diesel engine starting batteries and proper ventilation of the deck machinery house where the batteries are located. Accomplish to the satisfaction of the cognizant OCMI prior to 04FEB96.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Construction/Loadline
Issued 3 January 1996 Resolved
Make permanent repairs to fracture found in the after rake (15 cm) and to the wasted girder in the no. 1 port wing void (30 cm) at the vessel's next scheduled drydocking. Accomplish to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Deck/Cargo
Issued 3 January 1996 Resolved
Provide proper ventilation of the deck machinery house. Accomplish to the satisfaction of the cognizant OCMI prior to 04FEB96.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Lifesaving
Issued 3 January 1996 Resolved
Remove oily water from beneath the deck machinery house diesel engine assembly to the satisfaction of the cognizant OCMI prior to 04FEB96.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Documentation
Issued 3 January 1996 Resolved
Loadline markings not in accordance with International Loadline Certificatedated 20JAN95. Properly mark in accordance with dimensions indicated on theabove certificate. Permanently remove old loadline mark center punches. To be completed to the satisfaction of the cognizant OCMI prior to 04FEB96.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Documentation
Issued 3 January 1996 Resolved
Provide USCG approved Shipboard Oil Pollution Emergency Plan (SOPEP) as perMARPOL ANNEX 1, reg. 26, prior to carriage or use of any oil product on board the vsl. To be accomplished to the satisfaction of the cognizant OCMIprior to 04FEB96.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Construction/Loadline
Issued 3 January 1996 Resolved
Make permanent repairs to the frozen dogs and missing landing pads on the deck machinery house weathertight door. Accomplish to the satisfaction of the cognizant OCMI prior to 04FEB96.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Deck/Cargo
Issued 12 March 1991 Resolved
CONDUCT TEST OF PORT AND STARBOARD CARGO PUMP EMERGENCY SHUT DOWN SWITCHES PRIOR TO TRANSFER OF CARGO.
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Deck/Cargo
Issued 12 March 1991 Resolved
TEST AND CALIBRATE CARGO PUMP PRESSURE GAUGE. _x001C_
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Deck/Cargo
Issued 8 May 1990 Resolved
PROVIDE REQUIRED PLANS (I.E. COMPLETE CARGO PIPING, TANK VENTING AND SOUNDING,AND COMPLETE BILL OF MATERIALS) AS PER MSC-2 LTR 16710/PSBD HULL 111, SERIAL:MC-00226, DTD 01MAY90
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Deck/Cargo
Issued 26 January 1990 Resolved
PROVE PROPER OPERATION OF CARGO PUMP SHUT DOWNS.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Construction/Loadline
Issued 26 January 1990 Resolved
CLEAN DOUBLE BOTTOMS OF CAUSTIC SODA SOLUTION TO PERMIT INSPECTION OF INTERNAL STRUCTURE.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Documentation
Issued 13 November 1987 Resolved
PROVIDE A PROCEDURES AND ARRANGEMENT MANUAL WHICH HAS BEEN APPROVED BY CG HQ (G-MTH) OR DOCUMENTATION THE MANUAL HAS BEEN RECEIVED AT HQ PRIOR TO DISCHARGE OF CARGO OR RESIDUE AT SEA.
Condition: Unknown
Due 13 November 1987
Resolved 13 November 1987
Documentation
Issued 13 November 1987 Resolved
PRIOR TO CARRYING CAUSTIC SODA IN #1 AND #2 CENTER CARGO TANKS, HAVE ONBOARD THE VESSEL AN APPROVED STABLITY LETTER AND/OR LOADLINE CERTICATE AUTHORIZING SUCH CARRIAGE.
Condition: Unknown
Due 13 November 1987
Resolved 13 November 1987
Deck/Cargo
Issued 13 November 1987 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE CARGO PUMP EMERGENCY SHUTDOWNS AT THE NEXT DISCHARGE OF CARGO AND IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 13 November 1987
Resolved 13 November 1987
Deck/Cargo
Issued 1 December 1986 Resolved
TEST EMG PUMP SHUT DOWNS BEFORE OFF LOADING NEXT CARGO. TO BE DONE TO THE SATIFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 1 December 1986
Resolved 1 December 1986
Deck/Cargo
Issued 1 December 1986 Resolved
TEST RELIEF VALVES BEFORE DISCHARGE OF NEXT CARGO LOG SAME IN VESSELS OFFICAL LOG BOOK.
Condition: Unknown
Due 1 December 1986
Resolved 1 December 1986
Electrical
Issued 30 October 1985 Resolved
REPAIR SHORE POWER PLUG SECURING DEVICE BOLT.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Deck/Cargo
Issued 30 October 1985 Resolved
INSTALL GAUGE ON DISCHARGE SIDE OF CLEAN DIESEL PUMP
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Electrical
Issued 30 October 1985 Resolved
REPAIR BILGE PUMP CONTROLLER BOX DOOR LOCK AND SWITCH.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Deck/Cargo
Issued 30 October 1985 Resolved
REPAIR BEARING RETAINER ON STBD CARGO PUMP SHAFT
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Electrical
Issued 30 October 1985 Resolved
REPLACE BROKEN LAMP, INSTALL GUARD ON LIGHTS IN PUMP ROOM.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Electrical
Issued 30 October 1985 Resolved
SECURE DECK LIGHT WIRE RUNS TO STAND OFF ON PORT AND STBD SIDES.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Electrical
Issued 30 October 1985 Resolved
REMARK EMERG CARGO PUMP SHUT-OFF SWITCHES.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Deck/Cargo
Issued 30 October 1985 Resolved
PROVE SATISFACTORY OPERATION OF STBD CARGO PUMP AND TEST RELIEF VALVE. COMPLIANCE DATE ACTUALLY IS 15NOV85, LATE ENTRY INTO MSIS EXPLAINS OTHER
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Deck/Cargo
Issued 30 October 1985 Resolved
GAS FREE AND REPAIR FRACTURED WELD ON STBD CARGO PUMP RELIEF VALVE DISCHARGE TO SUCTION LINE.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Unknown
Issued 10 May 1985 Resolved
TEST EMERGENCY SHUTDOWNS FOR ALL PUMPING STATIONS. THIS ITEM WAS TO HAVE BEEN COMPLETED BY 30 MAY 1985.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Unknown
Issued 10 May 1985 Resolved
OPERATIONALLY TEST BILGE PUMP. THIS ITEM WAS TO HAVE BEEN COMPLETED BY 30 MAY 1985.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Unknown
Issued 10 May 1985 Resolved
OPERATIONALLY TEST CLEAN DIESEL PUMP. THIS ITEM WAS TO HAVE BEEN COMPLETEDBY 30 MAY 1985.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Unknown
Issued 10 May 1985 Resolved
OPERATIONALLY TEST #1 AND #2 CAUSTIC SODA PUMPS. CHECK GAUGES AND RELIEFS.THIS ITEM WAS TO HAVE BEEN COMPLETED BY 30 MAY 1985.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Unknown
Issued 10 May 1985 Resolved
OPERATIONALLY TEST #1 AND #2 CARGO OIL PUMPS. CHECK GAUGES AND RELIEFS. THIS ITEM WAS TO HAVE BEEN COMPLETED BY 30 MAY 1985.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.