MAURY USCG vessel records
← All vessels

BONITA

BONITA is a 1961 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in July 2025, along with 32 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 31 July 2025.

Built
1961
Last inspected
31 July 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 July 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP9430
Flag
UNITED STATES
Maury page id
psix-44147

Documentation record

Registered dimensions (L × B × D)52.9 ft × 14.5 ft × 6.1 ft
Registered tonnagegross 32 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSDIEGO MARINE CONST CO · SAN DIEGO CA, UNITED STATES · built 1961
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portTIBURON, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 32 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

31 July 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8194732
25 November 2024 Plan Review "T" Boat · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8037089
15 August 2024 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7981326
7 November 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7820988
8 November 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7591674
9 August 2022 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7534121
8 April 2022 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7429035
6 October 2021 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7327922
22 June 2021 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7233190
19 August 2020 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7043456
15 October 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6834453
22 July 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6758449
28 June 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6728764
30 July 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6469224
12 September 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6264704
12 June 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6174440
22 August 2016 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5970935

Deficiency record · 32

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 July 2025 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and pain lockers. Observed 02 openings in the bulkhead on both sides of the Fireboy in the engine room going into the next forward void compartment having cracked insulation around the wires. Re-insulate the 02 holes surrounding the wiring to become vapor-tight. (46 CFR 177.405(e))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 18 August 2025
Resolution: Vessel repaired cracked vaportight boundaries.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 31 July 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Observed crack and exposed wood on roof of boat, at the access point for lifesaving equipment. Repair cracked areas. (46 CFR 177.100)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2025
Resolved 4 November 2025
Resolution: MI visited vessel and found the satisfactory repairs for the roof crack completed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 July 2025 Resolved
Each buoyant apparatus shall be fitted with a life line and shall be equipped with a water light and painter. Observed that a water light was inoperable. Deficiency was rectified on the spot. (46 CFR 180.15-1(b)) [OLD T]
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 July 2025
Resolution: Deficiency was rectified on the spot.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 November 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 13 January 2025
Resolution: Vessel rep emailed copy of new / valid station license
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2024 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. Vessel name is not visible on bow. 46 CFR 67.123
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 13 January 2025
Resolution: Vessel rep submitted photos of vessel name clearly marked on port and starboard bow.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 November 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including (a)Inspection of all cable as far as practicable without undue disturbance of the cable or electrical apparatus. A run of wire from the alternator was blackened at a section between a relay and the batteries.46 CFR 176.806 (a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 13 January 2025
Resolution: Vessel rep emailed photo of replaced alternator wire installation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 November 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The line securing the floating light to the ring life buoy is deteriorated.46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 13 January 2025
Resolution: Vessel rep emailed photo of new lanyard for ring buoy water light
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 November 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. The alcohol test strips onboard are expired.46 CFR 4.06-15(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 13 January 2025
Resolution: Vessel rep submitted photo evidence of a sufficient number of unexpired alcohol test strips onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 November 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. (10) First-aid kit. Each first-aid kit must meet the requirements in ISO 18813:2006(E) paragraph 4.12. Vessel was found with expired medication and items missing to the standards of ISO 18813. 46 CFR 184.710
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 14 February 2024
Resolution: Vessel replaced expired medication.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 7 November 2023 Resolved
The float-free link required by § 180.130(a)(1) must be: (1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel could not provide the certification of the float free link. Vessel replaced the link with a properly certified one. 46 CFR 180.137(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 November 2023
Resolved 7 November 2023
Resolution: Vessel replaced the link with a properly certified link.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 7 November 2023 Resolved
Each paddle must be of at least (4 feet) in length, lashed to the life float to which it belongs and buoyant. Vessel's life float had to short of paddles and they were not lashed. Vessel replaced the paddles and properly lashed them to the life float. 46 CFR 180.175(f)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 November 2023
Resolved 7 November 2023
Resolution: Vessel replaced the paddles and properly lashed them to the life float.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 November 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel only had one operable portable battery light. Vessel replaced the batteries in the second portable battery light. 46 CFR 180.430
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 November 2023
Resolved 7 November 2023
Resolution: Vessel replaced the batteries in the second portable battery light. Both are now functional.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2022 Resolved
Each length of hose must: Be lined commercial fire hose that conforms to Underwriters' Laboratories Inc., Standard 19 or Federal Specification ZZ-H-451E. "Goodyear" Fire hose was observed onboard, ensure this hose meets UL standard or replace with conforming fire hose. 46 CFR 181.15-10(d)(1) "Old T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 18 November 2022
Resolution: Firehose meets UL standard.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 November 2022 Resolved
All ducts shall be of rigid permanent construction of fire proof material and reasonably gastight from end to end. Ventilation duct on port side was wasted and needs to be renewed. 46 CFR 182.20-45(d) "Old T"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 30 December 2022
Resolution: Ventilation cap sufficiently seals tube.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 November 2022 Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: Each hatch on a vessel that operates on protected waters. Forward void hatch needs to be made weathertight. 46 CFR 171.124(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 18 November 2022
Resolution: Gasket material replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 November 2022 Resolved
The following test & inspections must be carried out weekly on a vessel; each survival craft must be visually inspected to ensure readiness for use. Each survival craft on a vessel must be inspected monthly using the manufacturers instructions to ensure it is in good order. 46 CFR 185.720(a) 46 CFR 185.722
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 18 November 2022
Resolution: Vessel established lifesaving inspection recordkeeping procedures and logbook.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 October 2021 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Primary consideration shall be given to the provision of a seaworthy hull and necessary facilities for passengers and crew. The entirety of the wheelhouse was found to be excessively rotted, where primary lifesaving equipment is stored. Vessel must submit repair proposal for the replacement of rotted wood throughout.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2022
Resolution: Vessel completed satisfactory wheelhouse repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2021 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel. Vessel operating station electrical installations and controls had excessive corrosion and are exposed to the weather through holes in the structure of the pilot house. Ensure electrical installations are kept reasonably dry and remove dead end wires from unused equipment.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 November 2022
Resolution: Wheelhouse repairs have been made and electrical equipment properly installed to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 October 2021 Resolved
All kapok and fibrous glass life preservers which do not have plastic covered pad inserts, as required by subparts 160.002 and 160.005 of Subchapter Q (specifications) of this chapter, shall be removed from service. Plastic covered pad inserts in kapok life preservers leaked, allowing for water intrusion. Replaced on spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 October 2021
Resolution: Replaced the 3 Life jackets with Type I PFDs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 October 2021 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Vessel batteries secured connections through the use of wing nuts. Corrected on spot with mechanically fastened nuts. 46 CFR 183.05-20(c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 October 2021
Resolution: Corrected on spot with mechanically fastened nuts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2019 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MIs on board identified several kapok life-jackets needing to be replaced. Crew replaced life-jackets while MIs were on board.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 15 October 2019 Resolved
46CFR 177.01-5 - The scantlings, material, fastenings, workmanship, and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Vessel window at operating station cracked, and in need of repair/replacement.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 6 January 2020
Resolution: Vessel operator provided a picture of the new window.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2019 Resolved
A vessel that is exposed to salt water more than 3 months in any 12 month period since the last examination must undergo a dry dock examination and an internal structural at least once every two years. Vessel has not completed required dry dock inspection. Vessel must undergo a satisfactory dry dock inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2019
Resolved 11 September 2019
Resolution: Satisfactorily completed dry dock exam and internal structural exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2018 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electric shock. Audio equipment cables disconnected from receiver and left hanging bare in the pilothouse. Remove cables or connect them appropriately to receiver.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 21 August 2018
Resolution: exposed cables were properly connected to sound system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 July 2018 Resolved
Each hatch exposed to the weather must be watertight and be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss. Gasket for the hatch leading to the forepeak space must be replaced to maintain watertight integrity, along with captive chain corroded and needing replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 21 August 2018
Resolution: New captive chain installed and gasket for hatch replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 July 2018 Resolved
Vessel required to have 3 life floats as per COI. Vessel had two life floats on board with 40 person total capacity. Vessel restricted to no more than 78 passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 21 August 2018
Resolution: New life float installed
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 September 2017 Resolved
Lifejacket placard does not show donning instructions for all types on board; proper PFD placard required IAW 46 CFR 185.516.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 12 September 2017
Resolution: Proper PFD placard placed onboard IAW 46 CFR 185.516.
Construction/Loadline › Penetrations › Gasket
Issued 12 September 2017 Resolved
Wire conduit that penetrates the forward engine room bulkhead is not sealed vapor tight IAW 46 CFR 177.405(e). Seal penetration to ensure vapor tightness accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 12 September 2017
Resolution: Operator sealed conduit penetration vapor tight IAW 46 CFR 177.405(e).
Lifesaving › Lifefloat › Netting
Issued 22 August 2016 Resolved
Provide maintenance on liferaft netting. 46 CFR 185.702
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Provided repairs to liferaft netting.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 August 2016 Resolved
Provide maintenance on raw water intake gasket. 46 CFR 182.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 30 August 2016
Resolution: Replaced gasket in raw water intake stopping leaking.
Electrical › Lighting (service) › Conductor
Issued 22 August 2016 Resolved
Replace engine room lighting wiring. 46 CFR 183.220
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 20 September 2016
Resolution: Replaced wiring in kind.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 22 August 2016 Resolved
Provide copy of crew emergency instructions at operating station for fire, heavy wx, and MOB. 46 CFR 185.510
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 20 September 2016
Resolution: Provided boat specific emergency instructions.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.