ANGEL ISLAND

ANGEL ISLAND is a 1975 passenger vessel (inspected). The Coast Guard has recorded 121 inspections since 1984, most recently in April 2026, along with 204 deficiencies — 1 with no resolution recorded — and 6 casualty investigations between 2003 and 2026.

Records from 1984 to 2026. Most recent: inspection, 27 April 2026.

Built
1975
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WZB4244
Flag
UNITED STATES
367002980
Maury page id
psix-48352

Inspections, by type

…with no type recorded19
Years with a record 40 calendar years (1984–2026)
The 121 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)59.9 ft × 30.0 ft × 5.7 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · STOCKTON, CA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTIBURON, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WZB4244MMSI 367002980 · active · compulsorily equipped · granted 3 September 2025, expires 31 October 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BONITA Passenger (Inspected) · MISLE 44147 · 12 December 1995 · activity 188464

Inspection history · 121

27 April 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8382120
10 March 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8319821
6 May 2025 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8129244
11 February 2025 Deficiency Check · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8075373
19 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7876104
4 October 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7803569
11 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7666876
8 February 2023 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7634468
28 March 2022 COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7415820
24 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7205394
4 March 2021 Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7150589
24 February 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7141980
9 July 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7001883
28 April 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6945617
3 June 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6705603
14 May 2019 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6683435
4 February 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6618058
30 April 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6402391
17 April 2017 Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6126492
13 January 2017 In-Service Inspection · Examination of Repairs · Drydock Exam · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6070448
30 July 2016 Administrative Inspection · Hull Examination · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5959947
3 May 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5868017
21 October 2014 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5009303
23 July 2012 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4392487
7 May 2012 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4301981
1 August 2011 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4093624
7 February 2011 Examination of Repairs · Deficiency Check · Plan Review (Other than "T") · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3942104
18 February 2009 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3414691
26 January 2009 Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3400529
13 December 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3379327
24 June 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3234733
24 June 2008 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3246969
8 June 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2955536
11 May 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2928053
7 May 2007 COI Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2904243
21 February 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2879408
6 January 2007 Type not recorded
No type recorded · Station Golden Gate · USCG Southwest District (CGD-SW) · Activity 2851420
4 May 2006 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639380
16 July 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2428662
16 July 2005 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 2428789
30 March 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2323087
10 March 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2307532
4 February 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2285607
8 September 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2190351
28 July 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2147371
28 July 2004 MTSA Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2163290
16 May 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2079046
22 April 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2047953
22 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1990774
8 September 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1899926
30 July 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1861791
10 July 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1820987
10 July 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1877012
4 April 2003 Deadweight Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1753789
21 February 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1740397
14 January 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1730474
6 May 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1613416
18 June 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1465042
19 April 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1061649
11 January 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1393591
31 May 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384464
10 December 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 812109
24 November 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 811508
4 May 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1372607
22 June 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126904
8 October 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1388373
28 May 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1107710
6 May 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1082877
18 January 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181232
18 December 1995 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871786
18 December 1995 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 876415
18 December 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 882571
12 December 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 24622
12 December 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 188464
10 July 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1189227
8 February 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1167994
29 September 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 867124
11 July 1994 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 860561
26 May 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1170725
12 May 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387357
10 May 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 179888
5 April 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 837406
20 March 1993 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 825656
17 March 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 12
25 August 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 950038
17 August 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 643254
31 July 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1321170
22 July 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 951938
23 June 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1256968
5 May 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1461475
11 April 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 949786
9 April 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1259186
8 April 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 946290
27 January 1992 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954720
30 October 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257013
13 September 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1249933
6 August 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 938526
22 July 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1251914
9 July 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1249341
11 June 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1210866
6 March 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1304206
14 January 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1222450
1 August 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 905134
3 July 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1236626
26 June 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900410
31 May 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 930662
7 May 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1227168
30 April 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 923798
14 February 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1218947
31 May 1989 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1040344
23 February 1989 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 899287
13 June 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 890613
24 May 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 894268
9 December 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1310161
26 June 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1011502
30 May 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1335261
4 December 1986 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1023347
22 January 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 985590
21 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 986028
7 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 985938
19 December 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1285417

Deficiency record · 204

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 March 2026 No resolution recorded
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and... Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. MI identified a hole in the hull on the stbd quarter. Effect temp repair. Provide repair proposal/effect permanent repairs prior to next credit drydock. 46 CFR 176.25-5 "OLD T-L"
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 10 March 2026 Resolved
Each life float shall be fitted with a life line and shall be equipped with two paddles, a water light and a painter. MI identified water light line severed. 46 CFR 180.15-1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2026
Resolved 24 March 2026
Resolution: Received satisfactory photos of replaced light line.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 10 March 2026 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. MI identified that no fire drills had been conducted in 2025 and crew's knowledge regarding fire procedures was unsatisfactory. 46 CFR 122.524
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 March 2026
Resolved 10 March 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2026 Resolved
All electrical equipment and circuits must be clearly marked and identified. MI identified circuit breaker unlabeled. 46 CFR 120.220(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2026
Resolved 24 March 2026
Resolution: Received satisfactory photo of labeled breaker.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2026 Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories, Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 598, or shall bear the proper Underwriters' Laboratories, Inc. "Marine Type" label, or shall be constructed in accordance with the requirements of other recognized testing laboratories. MI identified light above the engine room access held together by electrical tape. 46 CFR 183.10-20(k)(1) "OLD T-L"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2026
Resolved 31 March 2026
Resolution: Received photos of fixed light.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 March 2026 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. MI identified a wooden plug in a pipe above the starboard engine room. 46 CFR 176.20-1 "OLD T-L"
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 April 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 March 2026 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level. All bilge alarms were inoperable. Vessel repaired alarms prior to MI departure. 46 CFR 119.530
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 March 2026
Resolved 10 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring life buoy, must be attached to a lanyard with a corrosion-resistant clip. Water light was secured to the body of the ring buoy with the lifeline by a knot. Attach water light to ring buoy per regulation to the satisfaction of MI. 46 CFR 117.70(d)(2)&(3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 May 2025
Resolved 6 May 2025
Resolution: Operator corrected deficiency same day. Photo uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to:(c) Minimize accidental personnel contact with energized parts. Breaker box had an opening/missing breaker creating a potential shock hazard. Remove hazard to satisfaction of MI. "Old T" 46CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Operator sent photo of empty breaker spaces blanked off. Photo uploaded to documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 February 2025 Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Crew door on port forward main deckhouse bulkhead not weathertight. Make repairs to the satisfaction of the MI. 46 CFR 116.1160 (d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2025
Resolved 3 April 2025
Resolution: MI attended vessel to verify repairs; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 March 2024 Resolved
A hydrostatic release unit when used in a float-free arrangement must be approved under approval series 160.062 or 160.162 or a standard specified by the Commandant. Painter for IBA on aft 2nd deck was not attached to hydrostatic release.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2024
Resolved 20 March 2024
Resolution: Resolved during inspection. Painter connected correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 March 2024 Resolved
A hydrostatic release unit when used in a float-free arrangement must be approved under approval series 160.062 or 160.162 or a standard specified by the Commandant. Buoyant apparatus stacked on 2nd deck were lashed to prevent blowing off due to high winds were secured with an expired hydrostatic release. Line securing BA's removed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2024
Resolved 20 March 2024
Resolution: Resolved during exam. Line securing BA's removed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 March 2024 Resolved
Buoyant apparatus, when stowed in tiers, the separate units must be kept apart by spacers. The buoyant apparatus stacked on 2nd deck had either insufficient or missing spacers in between each individual buoyant apparatus.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 13 May 2024
Resolution: Verified via photos.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2023 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. 24 life jackets were broken and replaced during inspection. New life jackets require markings. Properly label life jackets to the satisfaction of the marine inspector. Until new life jackets are placed in service, vessel's passenger count is limited to 376. 46 CFR 122.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 3 May 2023
Resolution: Labeled life jackets and placed in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023 Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring life buoy was cracked. Repair or replace ring life buoy to the satisfaction of the marine inspector. 46 CFR 117.70(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 3 May 2023
Resolution: Replaced ring life buoy.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 April 2023 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level. Engine room bilge alarm sensor is not properly secured and may not actuate during increased water level. Repair to the satisfaction of the marine inspector. 46 CFR 119.530(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 3 May 2023
Resolution: Secured bilge alarm sensor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Wire in engine room is improperly terminated. Repair to the satisfaction of the marine inspector. 46 CFR 183.01-15 "OLD T"
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 3 May 2023
Resolution: Properly terminated wires in engine room.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 April 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Asprin is expired. Replace to the satisfaction of the marine inspector. 46 CFR 121.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 3 May 2023
Resolution: Replaced expired asprin.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 February 2023 Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests: For portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by Chapter 4 of NFPA 10, (incorporated by reference, see § 114.600 of this chapter) with the frequency specified by NFPA 10. The owner or managing operator shall provide satisfactory evidence of the required servicing to the marine inspector. The portable fire extinguishers have not been serviced in the last year. Provide evidence of satisfactory service prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 February 2023
Resolution: Received inspection report for the portable fire extinguishers.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 March 2022 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Vessel needs to input MMSI number into VHF radio and link GPS to VHF to allow DSC feature to be operational. 47 CFR 80.905(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2022
Resolved 9 May 2022
Resolution: Vessel hooked up VHF into GPS to properly display appropriate information.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Vessel has multiple dead end wires and a blower that needs mounted in sewage tank void.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2022
Resolved 19 April 2022
Resolution: Vessel removed all dead end wires and mounted sewage tank.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 March 2022 Resolved
Spanner wrenches must be provided for each fire hydrant. Fire stations did not have spanner wrenches.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2022
Resolved 19 April 2022
Resolution: Vessel placed spanner wrenches at firestations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 March 2022 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessels name. Vessel had several kapok lifejackets that failed inspection, but replaced them with unmarked life jackets.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2022
Resolved 31 March 2022
Resolution: Vessel replaced lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 May 2021 Resolved
An adult lifejacket must be provided for each person carried on board a vessel. 29 PFDs in unservicable condition. Replace PFDs. Passenger count limited to 375.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 2 July 2021
Resolution: Operator replaced all 29 adult lifejackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 May 2021 Resolved
Spanner wrenches must be provided for each fire hydrant required. Spanner wrenches missing at fire stations #1 and #2. Provide wrenches in near proximity to stations.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 2 July 2021
Resolution: Spanner wrenches have been placed on the first and second decks nearby to the sire stations.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 24 May 2021 Resolved
Penetrations in watertight bulkheads must have a means to make them watertight. 04 holes leading from engine room to forward void space. Complete by next dry dock.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 February 2023
Resolution: Attending MI verified repair of openings from engine room to forward void space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 May 2021 Resolved
The number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. 08 child PFDs not servicable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 June 2021
Resolved 11 June 2021
Resolution: Operator replaced 08 child PFDs with new PFDs
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 May 2021 Resolved
Each lifesaving craft must be marked with Type II retroreflective material. Life float retroreflective tape worn.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 May 2021
Resolution: Operator replaced retroreflective tape
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 July 2020 Resolved
An inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant no later than the month and year on its servicing sticker, except that servicing may be delayed until the next scheduled inspection of the vessel, provided that the delay does not exceed 5 months. Vessel's IBA is expired. Vessel is limited to 1 NM from shore with 149 passengers until IBA is serviced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 April 2021
Resolution: Received picture of serviced IBA
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 30 April 2018 Resolved
Replace the expired hydrostatic release on the IBA. Passenger count limited to 120 when operating beyond 1 mile. Remove/replace the expired hydrostatic release unit securing the flife floats prior to carrying passengers. 46CFR117.130
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 12 May 2018
Resolution: New Hydrostatic release installed; photo documentation provided.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 30 April 2018 Resolved
Inspect all lifejackets and reew vessel name in block capital letters. 46CFR122.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 12 May 2018
Resolution: All faded names have been renewed.
Engineering › Bilge Water Management System › Not Installed
Issued 30 April 2018 Resolved
Install a direct engine room bilge suction, independent of the bilge main IAW 46CFR56.50-45(e). Provide updated drawing prior to commencing installation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 12 March 2021
Resolution: Direct engine room bilge suction has been installed.
Engineering › Bilge Water Management System › Piping
Issued 30 April 2018 Resolved
Replace the lazarette bilge suction line with a permanently installed metallic pipe. The through watertight blkhd penetration must be vapor and water tight, welded. 46CFR119.710(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 12 March 2021
Resolution: Lazarette bilge line is hard piped and the penetration is welded.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 30 April 2018 Resolved
Renew the batteries in the inoperable emergency lights and provide proof of proper operation. 46CFR120.432
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 12 March 2021
Resolution: Vessel is not required to have emergecy lights due to the configuration of the vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 30 April 2018 Resolved
Procure an updated chart for each operating area. 46CFR121.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 12 March 2021
Resolution: Updated charts have been procured.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 27 April 2017 Resolved
In Galley, a 110 V GFCI outlet was found not mounted and laying on the counter energized. 46 CFR 183.10-20 (g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 30 May 2017
Resolution: Mounted Outlet.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 April 2017 Resolved
Two light fixtures in forward of Engine Room are hanging by zip ties.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 31 May 2017
Resolution: Light Fixtures are mounted in the engine room.
Engineering › Pressure Vessel › Piping
Issued 27 April 2017 Resolved
Piping into hot water heater was severly corroded and needs replacement. 46 CFR 182.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 18 July 2017
Resolution: Hot Water Heater was removed from vessel.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 April 2017 Resolved
Fire Extinguisher outside Engine Room was not mounted in bracket as required on label. 46 CFR 181.30-10
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 31 May 2017
Resolution: Fire Extinguisher is mounted on the bulkhead.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 April 2017 Resolved
Forward SSDG was missing exhaust lagging on turbo. 46 CFR.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 31 May 2017
Resolution: Installed Heat Shield.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 April 2017 Resolved
Aft SSDG was missing lagging on exhaust manifold. 46 CFR 182.01-5
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 31 May 2017
Resolution: Installed heat sheilding.
Engineering › Bilge Water Management System › Strainer
Issued 27 April 2017 Resolved
Engine Room Bilge Piping did not have a strainer installed. 46 CFR 182.510 (b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 May 2017
Resolved 12 March 2021
Resolution: Engine room bilge pickup has strainer installed.
Engineering › Bilge Water Management System › Valve
Issued 27 April 2017 Resolved
Engine Room Bilge Piping is missing check valve. 46 CFR 182.510 (c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 31 May 2017
Resolution: Check Valve is installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 April 2017 Resolved
COI Requirement onboard 404 adult life jackets, vessel was short 17 adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 27 April 2017
Resolution: Owner corrected on spot and added 17 new adult life jackets into service.
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 27 April 2017 Resolved
Weak Link was not attached and 4 life floats were not tethered together. 46 CFR 180.137
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 27 April 2017
Resolution: Attached Life Floats together and connected weak link.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 27 April 2017 Resolved
port forward life jacket stowage was not marked with number of life jackets contained within. 46 CFR 185.604 (f)
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 18 July 2017
Resolution: Life Jacket storage was labeled.
Engineering › Bilge Water Management System › Piping
Issued 27 April 2017 Resolved
Lazarette does not have a bilge system piped to it IAW 46 CFR 119.510. Owner will install prior to November 1, 2017.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 12 March 2021
Resolution: Lazarette has installed bilge piping.
Documentation › Logs/Records › Drug Test Records
Issued 23 July 2012 Resolved
Documentation of pre-employment testing not kept for entire employment period as required by 46 CFR 16.260.
Due 22 August 2012
Resolved 23 July 2012
Resolution: DER sent copies of missing pre-employment record entries.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008 Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Due 24 July 2008
Resolved 24 June 2008
Resolution: Company has form on file and conducted history check and completed check for employees hired within the previous two years.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008 Resolved
Arrangements not made for post-casualty testing as required by 46 CFR part 16.240.
Due 24 July 2008
Resolved 13 August 2008
Resolution: Company has post-casualty testing arrangements written in updated policy.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008 Resolved
Alcohol testing devices not onboard as required by 46 CFR part 4.
Due 24 July 2008
Resolved 13 August 2008
Resolution: ALCO Screen-02 DOT alcohol testing device is now carried aboard vessel.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008 Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Due 24 July 2008
Resolved 14 August 2008
Resolution: Company is using SAMHSA''''s National Clearinghouse video for 1 hour training required for their supervisors.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008 Resolved
Company did not have records of pre-employments as required by 46 CFR 16.210.
Due 24 July 2008
Resolved 24 June 2008
Resolution: Company provided memo for personnel employed with the company for 12 years stating the employee has been in the random selection pool and received testing, but no longer had a pre-employment test on file.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 June 2008 Resolved
Replace missing electrical box cover on fire pump located in engine room.
Due 24 July 2008
Resolved 23 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 June 2008 Resolved
Provide 20 additional adult Type I PFD's. Vessel is restricted to carrying a maximum of 380 persons on board until corrected.
Action required: 705 - Other - as specified
Due 24 July 2008
Resolved 23 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 June 2008 Resolved
Properly label all PFD stowage areas.
Due 24 July 2008
Resolved 23 July 2008
Lifesaving › Buoyant Apparatus › Serviceable
Issued 24 June 2008 Resolved
Have two (2) Buoyant Apparatus professionally evaluated and repaired if serviceable - fax report to [phone withheld]. (BA's to be serviced have loose/broken grab line securing rings).
Due 24 July 2008
Resolved 23 July 2008
Resolution: Replaced two BA''s with new life floats, properly labeled, and equipped.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 24 June 2008 Resolved
Properly secure sea painter to weak link on inflatable life raft.
Due 24 July 2008
Resolved 23 July 2008
Resolution: Found sea painter improperly secured to weak link again. Informed Vsl Captain of improper arrangement, corrected, and asked him to instruct all crewmembers who may be involved with maintaining this equipment.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 24 June 2008 Resolved
Provide proper distress signal storage container IAW 46CFR 117.68 and 122.614.
Due 24 July 2008
Resolved 23 July 2008
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 24 June 2008 Resolved
Provide up to date crew training log.
Due 24 July 2008
Resolved 23 July 2008
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 24 June 2008 Resolved
Provide up to date emergency equipment maintenance log.
Due 24 July 2008
Resolved 23 July 2008
Engineering › Fuel Oil Service System › Ventilation
Issued 24 June 2008 Resolved
Install fuel tank vent screen I.A.W. 46CFR 119.450(d).
Due 24 July 2008
Resolved 23 July 2008
Construction/Loadline › Structures › Deck Plating
Issued 24 June 2008 Resolved
Evaluate hole penetrating through deck on port side mid ships (by center cleat) into port - mid ships void. Provide repair proposal to CG Sector San Francisco prior to commencing repairs, fax [phone withheld].
Due 24 July 2008
Resolved 6 August 2008
Resolution: Reviewed repair proposal. Approved proposed repair plans. Confirmed repairs via email.
Engineering › Lubricating Oil Service System › Piping
Issued 7 May 2007 Resolved
Repair hydraulic leak in accommodation space void, port side overhead forward.
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 8 June 2007
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 7 May 2007 Resolved
Repair coolant leak from gate valve in centerline of engine room.
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 8 June 2007
Engineering › Steering Gear System › Ram Seal
Issued 7 May 2007 Resolved
Repair hydraulic leak in steering arm in lazarette.
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 8 June 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 7 May 2007 Resolved
Relocate one A:I fire extinguisher from first deck accommodation space to second deck accommodation space.
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 8 June 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 May 2007 Resolved
Vessel is restricted to 346 passengers until 50 additional adult PFD's are provided.
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 11 May 2007
Resolution: Operator provided proof of purchase for 60 adult PFD''s which are now on board the vessel.
Lifesaving › Buoyant Apparatus › Float Free
Issued 7 May 2007 Resolved
Make BA's float free by disconnecting expired hydrostatic release or by providing new hydrostatic release.
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 7 May 2007
Resolution: Disconnected hydrostatic release.
Lifesaving › Buoyant Apparatus › Painter
Issued 7 May 2007 Resolved
Connect 2 forward most top BA's to the painter.
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 7 May 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marine Type Label
Issued 7 May 2007 Resolved
Install one B:II portable fire extinguisher for engine room space.
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 7 May 2007
Documentation › Certificates/Documents › FCC SSL
Issued 4 May 2006 Resolved
Provide proof of current FCC Safety Certificate. This may be faxed to our office at [phone withheld].
Due 4 May 2006
Resolved 5 May 2006
Engineering › Steering Gear System › Piping
Issued 4 May 2006 Resolved
Make repairs to hydraulic lines in way of Lower Middle Hold and Portable Water Tank compartments.
Due 20 June 2006
Resolved 16 June 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 May 2006 Resolved
Install missing blank inserts in way of electrical panel closet on main deck.
Due 4 June 2006
Resolved 16 June 2006
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 4 May 2006 Resolved
Conduct DAPI Audit/Training with Drug & Alcohol Program Inspector.
Due 4 June 2006
Resolved 19 May 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 May 2006 Resolved
Provide a Lifejacket donning placard on upper deck near PFD stowage area.
Due 4 June 2006
Resolved 4 May 2006
Lifesaving › Lifebuoys › Serviceable
Issued 4 May 2006 Resolved
Replace Life Buoy.
Due 4 June 2006
Resolved 4 May 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 May 2006 Resolved
Install missing front cover screws in way of electrical panel closet on main deck.
Due 4 June 2006
Resolved 4 May 2006
Personnel › Certificates/Documents/Licenses › License, Master
Issued 16 July 2005 Resolved
Master must have their original license on board while vessel is in normal operation IAW 46 CFR 122.402.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2005
Resolved 16 July 2005
Resolution: Master provided Station SF boarding team with his original license.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 May 2005 Resolved
Provide onboard 55 additional adult lifejackets. Vessel passenger count is limited to 345 passengers until cleared.
Due 1 June 2005
Resolved 2 June 2005
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 May 2005 Resolved
Prove proper operation of radar. Vessel's route is limited to short runs between Tiburon and [name withheld] until cleared.
Due 1 June 2005
Resolved 19 May 2005
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 18 May 2005 Resolved
Post station bill.
Due 18 May 2005
Resolved 18 May 2005
Resolution: Corrected on spot.
Lifesaving › Hand Flares › Storage
Issued 18 May 2005 Resolved
Provide watertight container for stowage of distress signals.
Due 18 May 2005
Resolved 18 May 2005
Resolution: Corrected on spot.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 18 May 2005 Resolved
Attach floating waterlight to top buoyant apparatus of forward group.
Due 18 May 2005
Resolved 18 May 2005
Resolution: Corrected on spot.
Lifesaving › Buoyant Apparatus › Painter
Issued 18 May 2005 Resolved
Properly attach forward group of buoyant apparatus in tandem.
Due 18 May 2005
Resolved 18 May 2005
Resolution: Corrected on spot.
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2005 Resolved
Repair four deep pits in way of port side upper hull circled in yellow chalk. Prior to credit for dry dock.
Action required: 705 - Other - as specified
Resolved 7 February 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 February 2005 Resolved
Properly dead end and label electrical wires in way of aft bulkhead center of engine room. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 7 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2005 Resolved
Repair as new two holes in way of fwd stbd void from the removal of the old bumper mounts. prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 7 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2005 Resolved
Provide plans to repair hull crack in way of fwd port void. prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 7 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2005 Resolved
Renew potable water fill hull plating in way of port side hull in galley. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 16 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2005 Resolved
Provide plans to renew sewage box hull platting and vent goose neck in way of women’s head stbd side. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 16 February 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 February 2005 Resolved
Properly dead end electrical wire in way of galley sink aft port side. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 7 February 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 4 February 2005 Resolved
Renew broken light cover in way of women’s head.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 10 March 2005
Engineering › Lubricating Oil Service System › Piping
Issued 4 February 2005 Resolved
Repair hydraulic leak in way of center mid void fwd (pipes in overhead) and clean up oil in bilge.
Action required: 705 - Other - as specified
Due 20 February 2005
Resolved 18 February 2005
Engineering › Freshwater System (air cooling) › Piping
Issued 4 February 2005 Resolved
Conduct hydro test of the MDE plate cooling system in the presence of the CG marine inspector. Clean up coolant in the mid void space.
Action required: 705 - Other - as specified
Due 20 February 2005
Resolved 18 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2005 Resolved
Repair as new two holes in way of stbd side aft lazarrate overhead corner. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 7 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2005 Resolved
Repair as new, metal frame bulwark, in way of fantail, Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 7 February 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 28 July 2004 Resolved
Update crewlist for Drug and Alcohol Program.
Due 28 August 2004
Resolved 7 September 2004
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2004 Resolved
Update nautical publications (charts, lightlist, coast pilot).
Due 28 August 2004
Resolved 7 September 2004
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 28 July 2004 Resolved
Provide proof of current hydrostatic release for inflatable buoyant apparatus.
Due 28 August 2004
Resolved 7 September 2004
Lifesaving › Lifeboat Equipment › Batteries (electric torch spares)
Issued 28 July 2004 Resolved
Provide proof of battery replacement/expiration on water light.
Due 28 August 2004
Resolved 7 September 2004
Lifesaving › Buoyant Apparatus › Float Free
Issued 28 July 2004 Resolved
Correct Buoyant Apparatus stowage and stencil applicable markings.
Due 28 August 2004
Resolved 7 September 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 28 July 2004 Resolved
Provide proper mount for B-II fire extinguisher in way of entry to engine room.
Condition: Unknown
Due 28 August 2004
Resolved 7 September 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 July 2004 Resolved
Provide proper splice for electrical wiring in way of second deck ladder and forward starboard main deck emergency light.
Due 28 August 2004
Resolved 7 September 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 July 2004 Resolved
Provide supports for electrical wiring in way of second deck ladder.
Due 28 August 2004
Resolved 7 September 2004
Engineering › Bilge Water Management System › Interface Detector
Issued 28 July 2004 Resolved
Properly mount bilge high water alarm indicator in engine room.
Due 28 August 2004
Resolved 7 September 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 22 April 2004 Resolved
Replace covers on flourescent lights in galley, heads and main deck passenger area.
Action required: 705 - Other - as specified
Due 22 May 2004
Resolved 28 July 2004
Construction/Loadline › Structures › Door
Issued 22 April 2004 Resolved
Provide plans to replace doors leading to upper deck. LEGACY COMPONENT DESC: Door
Due 31 October 2004
Resolved 4 February 2005
Construction/Loadline › Structures
Issued 22 April 2004 Resolved
Make temporary repairs to doors leading to upper deck. LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 27 April 2004
Resolution: Sheet metal patch installed over corroded section of door.
Electrical › Lighting (emergency)
Issued 22 April 2004 Resolved
Remove wire nut by stbd bow access door in Emergency lighting system. LEGACY COMPONENT DESC: Conductor
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 27 April 2004
Resolution: Removed wire nuts.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 April 2004 Resolved
Provide proof that pan coolers are not leaking in to center hold.
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 23 April 2004
Resolution: Operational test completed by Bay Ship, no leaks found.
Engineering › Fuel Oil Service System
Issued 8 September 2003 Resolved
Replace diesel fuel strainer/filters with cg approved type, IAW 46CFR182.455(b)(6). LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 8 October 2003
Resolved 27 April 2004
Lifesaving › Buoyant Apparatus
Issued 10 July 2003 Resolved
Replace pennants on waterlights attached to Bouyant Apparatus, with correct length.
Action required: 705 - Other - as specified
Due 10 August 2003
Resolved 19 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 July 2003 Resolved
Complete installation of exhaust lagging. LEGACY COMPONENT DESC: Silencer (exhaust)
Action required: 705 - Other - as specified
Due 10 August 2003
Resolved 19 August 2003
Lifesaving
Issued 24 November 1999 Resolved
VESSEL MUST UNDERGO A SATISFACTORY CREDIT DRYDOCK PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Lifesaving
Issued 22 June 1998 Resolved
REPLACE PFD'S WITH TORN STITCHING.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Construction/Loadline
Issued 6 May 1996 Resolved
LABEL BILGE MANIFOLD SYSTEM WITH PERMANENT IDENTIFICATION
Condition: Unknown
Due 6 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 18 December 1995 Resolved
CROP OUT AND RENEW HULL PLATING IN CENTERLINE OF FORWARD CENTER VOID.
Condition: Unknown
Due 15 January 1996
Resolved 20 February 1996
Construction/Loadline
Issued 18 December 1995 Resolved
CROP OUT AND RENEW LONGITUDINAL WELD IN THE PORT SIDE STRINGER IN THE PORT FORWARD VOID.
Condition: Unknown
Due 15 January 1996
Resolved 20 February 1996
Construction/Loadline
Issued 18 December 1995 Resolved
BACK GOUGE AND REWELD CRACKED WELD IN DECK STRINGER IN #4 PORT COMPARTMENT.THIS MAY BE COMPLETED AT NEXT DRYDOCK TO AVOID WELD ON A HULL THAT IS SUBMERGED IN WATER.
Condition: Unknown
Due 28 February 1997
Resolved 20 February 1996
Construction/Loadline
Issued 18 December 1995 Resolved
LONGITUDINAL WELD IN THE PORT SIDE STRINGER IS SEPARATED FROM THE BULKHEAD IN THE PORT FORWARD VOID.
Condition: Unknown
Due 19 January 1996
Resolved 20 December 1995
Construction/Loadline
Issued 18 December 1995 Resolved
CRACKED WELD IN DECK STRINGER OF PORTSIDE CENTER VOID.
Condition: Unknown
Due 19 January 1996
Resolved 20 December 1995
Construction/Loadline
Issued 18 December 1995 Resolved
CRACK THROUGH HULL PLATING IN CENTERLINE OF FORWARD CENTER VOID.
Condition: Unknown
Due 19 January 1996
Resolved 20 December 1995
Engineering
Issued 10 July 1995 Resolved
PROVIDE CHAFFING PADS FOR GENERATOR FUEL LINES.
Condition: Unknown
Due 10 August 1995
Resolved 5 September 1995
Navigation
Issued 10 July 1995 Resolved
REPAIR/RENEW ANCHOR LIGHT.
Condition: Unknown
Due 10 August 1995
Resolved 5 September 1995
Lifesaving
Issued 10 July 1995 Resolved
PROVIDE PLACARD STATING MAXIMUM ALLOWED PASSENGERS ON UPPER DECK.
Condition: Unknown
Due 10 August 1995
Resolved 5 September 1995
Navigation
Issued 10 July 1995 Resolved
PROVIDE SUPPORT HANGER FOR HYDRAULIC PIPING IN #3 CENTER HOLD.
Condition: Unknown
Due 10 August 1995
Resolved 5 September 1995
Construction/Loadline
Issued 10 July 1995 Resolved
CLEAN UP OIL ON DIESEL ENGINES AND ENGINEROOM BILGES.
Condition: Unknown
Due 10 August 1995
Resolved 5 September 1995
Engineering
Issued 10 July 1995 Resolved
PROVIDE SECURING DEVICES FOR LIDS OF HYDRAULIC RESERVOIRS ON ENGINE DRIVEN HYDRAULIC PUMP SYSTEM.
Condition: Unknown
Due 10 August 1995
Resolved 5 September 1995
Engineering
Issued 10 July 1995 Resolved
PROVIDE FLAME SCREEN FOR VENT PIPING ON MDE FUEL RETURN RESERVOIR (LOCATED IN E/R HIGH EXHAUST VENT DUCT).
Condition: Unknown
Due 10 August 1995
Resolved 5 September 1995
Electrical
Issued 10 July 1995 Resolved
REPLACE BATTERIES TO TWO AFT MAIN DECK BATTLE LANTERNS.
Condition: Unknown
Due 10 August 1995
Resolved 5 September 1995
Lifesaving
Issued 10 July 1995 Resolved
PROVIDE TIE-DOWN STRAP FOR LUBE OIL DRUM.
Condition: Unknown
Due 10 August 1995
Resolved 5 September 1995
Construction/Loadline
Issued 8 February 1995 Resolved
PROVIDE HULL GAUGING REPORT.
Condition: Unknown
Due 22 February 1995
Resolved 6 March 1995
Navigation
Issued 8 February 1995 Resolved
PROVIDE PROOF OF PROPER STBD. RUDDER INSTALLATION.
Condition: Unknown
Due 22 February 1995
Resolved 6 March 1995
Fire Fighting
Issued 11 July 1994 Resolved
PRIOR TO SAILING, BUT NLT 11AUG94, SERVICE ALL FIRE EXTINGUISHERS AND PROVIDE METALIC (BRONZE OR EQUIV.) FITTINGS & NOZZLES FOR FIRE HOSES.
Condition: Unknown
Due 11 August 1994
Resolved 26 July 1994
Navigation
Issued 11 July 1994 Resolved
PROVIDE UPDATED COMPASS DEVIATION CARD.
Condition: Unknown
Due 11 July 1994
Resolved 11 July 1994
Electrical
Issued 11 July 1994 Resolved
PROPERLY DUNNAGE BATTERIES W/IN BATTERY BOXES.
Condition: Unknown
Due 11 August 1994
Resolved 26 July 1994
Navigation
Issued 11 July 1994 Resolved
PRIOR TO SAILING & NLT 11AUG94, CONDUCT SATISFACTORY MAN OVER BOARD DRILL.
Condition: Unknown
Due 11 August 1994
Resolved 26 July 1994
Construction/Loadline
Issued 5 April 1993 Resolved
CLEAN AND PROPERLY SEAL FRESHWATER TANK.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 5 April 1993 Resolved
PORPERLY SEAL SCREWS ON MSD HOLDING TANK.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Navigation
Issued 20 March 1993 Resolved
PROVIDE COTTER PINS FOR PRT AND STB ENDS OF STEERING CONNECTING ARM.
Condition: Unknown
Due 20 March 1993
Resolved 20 March 1993
Construction/Loadline
Issued 5 May 1992 Resolved
ENSURE MAINDECK RECESSES HAVE WEATHERTIGHT COVERS HELD ON BY SIX FASTENERS MINIMUM.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Lifesaving
Issued 5 May 1992 Resolved
RENEW 3 ORANGE SMOKE FLARES
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Navigation
Issued 5 May 1992 Resolved
NAV LIGHTS MUST BE CORRECTED (PLANS APPROVED FIRST). 32 PT MASTHEAD LIGHT MUST BE MOVED TO AFTER PART OF VESSEL AND 20 PT MASTHEAD LIGHT REMOVED, OR REMOVE 32 PT MASTHEAD LIGHT AND INSTALL 12 PT STERNLIGHT IN ADDITION TO 20 PT MASTHEAD LIGHT.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Accommodation/Occupational Safety
Issued 5 May 1992 Resolved
SECURE CHAINLINK RAILING AT 8 AREAS ELIMINATING WIRE TIES.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Construction/Loadline
Issued 5 May 1992 Resolved
PROPERLY REPAIR CRACKED WELD ON DECKBEAM AT SIDESHELL IN STBD FOREPEAK
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Fire Fighting
Issued 5 May 1992 Resolved
PROVIDE NEW 5/8 MIN ID FIREHOSE FOR MAINDECK STATION.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Accommodation/Occupational Safety
Issued 5 May 1992 Resolved
SECURE DISCHARGE LINE LEADING FROM F/W TANK.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Fire Fighting
Issued 5 May 1992 Resolved
THE SCUTTLE TO THE PILOTHOUSE MUST BE CLOSED AT ALL TIMES. THE EXPANDED METAL GRATE CANNOT BE USED.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Fire Fighting
Issued 5 May 1992 Resolved
SUCTION HOSE FOR HAND FIRE/BILGE PUMP MUST BE LENGTHENED SO THAT IT WILL REACH INTO THE WATER FROM THE MAINDECK.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Fire Fighting
Issued 5 May 1992 Resolved
THE DOUBLE DOORS LEADING TO THE UPPER DECK MUST BE SELF CLOSING AND NOT TIED OPEN AT ANY TIME. THE USE OF MAGNETIC HOLD BACK DEVICES ARE AUTHORIZEDAND MUST BE CONTROLLED AT THE PILOTHOUSE.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Fire Fighting
Issued 5 May 1992 Resolved
THE STOVE IN THE CONCESSION BOOTH MUST BE REMOVED.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Electrical
Issued 5 May 1992 Resolved
REPLACE MISSING PLUG IN RECEPTICLE NEAR HEATER BY CERTIFICATES.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Electrical
Issued 5 May 1992 Resolved
PERMANENTLY MOUNT P/A SPEAKER HANGING NEAR GALLEY.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Construction/Loadline
Issued 8 April 1992 Resolved
MAKE PROPER WELD REPAIR TO SEAM IN BOW RAKE PORT SIDE.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Lifesaving
Issued 8 April 1992 Resolved
PROVIDE FLOATLIGHTS FOR ALL BUOYANT APPARATUS.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Documentation
Issued 8 April 1992 Resolved
PROVIDE CURRENT COI.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Accommodation/Occupational Safety
Issued 8 April 1992 Resolved
PROVIDE GASKETS FOR FORWARD EXTERIOR DOORS.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Lifesaving
Issued 8 April 1992 Resolved
PROVIDE NEW BATTERIES FOR RING BUOY FLOAT LIGHT.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Construction/Loadline
Issued 8 April 1992 Resolved
MAKE PROPER WELDS ON OVERBOARD THROUGH HULL PIPING IN WAY OF SNACK BAR,_x001C_ PORT SIDE, AND HEAD, STBD SIDE.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Documentation
Issued 11 June 1991 Resolved
PROVE INTENT TO COMPLY WITH DRUG MANAGEMENT PROGRAM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Documentation
Issued 11 June 1991 Resolved
PROVIDE WASTE MANAGEMENT PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Documentation
Issued 11 June 1991 Resolved
PROPERLY MOUNT MARPOL V PLACARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Fire Fighting
Issued 11 June 1991 Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS ( THEY ARE DUE 25JUN91)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Documentation
Issued 11 June 1991 Resolved
SHOW FCC STATION LICENSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Navigation
Issued 3 July 1990 Resolved
PROVIDE STEERING COMPASS DEVIATION CARD.
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Electrical
Issued 3 July 1990 Resolved
PROVIDE COVER FOR AUX/MAIN GEN. SWITCH PANEL BOX AT TOP OF E/R LADDER.
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Documentation
Issued 3 July 1990 Resolved
OBTAIN RADAR OBSERVERS ENDORSEMENT FOR OPERATOR'S LICENSE.
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Electrical
Issued 3 July 1990 Resolved
PROVIDE HINGES, OR OTHER SECURING DEVICE, FOR PANEL BOX IN E/R.
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Electrical
Issued 31 May 1990 Resolved
REWIRE AS NECESSARY TO BRING ENGINEROOM ELECTRICAL SYSTEMS AND WIRING RUNS AND TERMINATIONS INTO COMPLIANCE WITH NEC STANDARDS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Engineering
Issued 31 May 1990 Resolved
INSTALL FLAME SCREENS ON FUEL TANK VENTS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Lifesaving
Issued 31 May 1990 Resolved
PROVIDE FRESH BATTERIES FOR LIFERING AND BUOYANT APPARATUS WATERLIGHTS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Lifesaving
Issued 31 May 1990 Resolved
INSTALL SERVICEABLE AND ADEQUATE LIFELINES ON ALL BUOYANT APPARATUS (REMOVEOLD LIFELINES) AND REPLACE BLACK AND ORANGE TAG LINE ON AFTER TOP BUOYANT APPARATUS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Lifesaving
Issued 31 May 1990 Resolved
PROVIDE AN ADDITIONAL 4 ADULT LIFE PRESERVERS. UNTIL THIS REQUIREMENT IS MET, THE MAXIMUM NUMBER OF PERSONS ALLOWED ONBOARD IS 396.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Engineering
Issued 31 May 1990 Resolved
REHANG AIR SVC LINE TO PORT ENGINE - REMOVE LINE HANGER.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Engineering
Issued 31 May 1990 Resolved
REPLACE PRIME MOVER RADIATOR HOSES (ENGINES AND GENERATOR) WHERE WORN AND PLACE AT LEAST ONE CLAMP ON EACH HOSE FITTING.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990 Resolved
LABEL ALL BREAKERS AND INSTALL BLANKS IN EMPTY SLOTS IN ALL ELECTRICAL PANELS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Engineering
Issued 31 May 1990 Resolved
REPAIR LEAK AT BILGE SUCTION LINE PASS-THROUGH NEAR CENTERLINE IN FWD ENGINEROOM BULKHEAD.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Navigation
Issued 31 May 1990 Resolved
PRODUCE STEERING COMPASS DEVIATION CARD.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Fire Fighting
Issued 31 May 1990 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS AND REPLACE HOSE ON DRY CHEMICAL EXTINGUISHER SER#AZ-962523.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Navigation
Issued 31 May 1990 Resolved
DEMONSTRATE OPERATION OF VESSEL'S RADAR SYSTEM.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Engineering
Issued 31 May 1990 Resolved
DEMONSTRATE OPERATION OF VESSEL'S BILGE SUCTION SYSTEM.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Engineering
Issued 14 February 1990 Resolved
1 CUT LIMBER HOLES IN THE LONGITUDINAL GIRDERS IN THE CENTER COMPARTMENTS AND THE LONGITUDINAL BULKHEADS TO ALLOW DRAINAGE TO THE EXISTING BILGE PIPE SUCTION. DO NOT CUT ANY HOLES IN THE TRANSVERSE WATERTIGHT BULKHEADS
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Lifesaving
Issued 31 May 1989 Resolved
2 INSTALL EYE BOLT ON BUOYANT APPARATUS.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Fire Fighting
Issued 31 May 1989 Resolved
3HYDRO 2 BII PORTABLE FIRE EXT AND SERVICE.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Fire Fighting
Issued 31 May 1989 Resolved
4 SERVICE BI PORTABLE FIRE EXT ON BRIDGE.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Engineering
Issued 31 May 1989 Resolved
5 INSTALL 30X30 MESH FLAME SCREENS ON FUEL VENTS.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Lifesaving
Issued 31 May 1989 Resolved
1 REPLACE MANILA LIFELINES ON ALL BUOYANT APPARATUS.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Navigation
Issued 31 May 1989 Resolved
6 INSTALL A STERNLIGHT AS REQUIRED BY RULE 23 OF THE NAVIGATION RULES.
Condition: Unknown
Due 31 May 1989
Resolved 31 May 1989
Construction/Loadline
Issued 23 February 1989 Resolved
CONDUCT DYE PENETRANT TEST OF FIRE/BILGE PUMP SUCTION SPOOL PIECE WHERE WELDED TO THE PLATING.
Condition: Unknown
Due 23 February 1989
Resolved 23 February 1989
Construction/Loadline
Issued 23 February 1989 Resolved
CONDUCT DYE PENETRANT TEST OF INSERT IN PORT SIDE OF FOREPEAK BOTTOM PLATING.
Condition: Unknown
Due 23 February 1989
Resolved 23 February 1989
Construction/Loadline
Issued 9 December 1987 Resolved
PROVIDE COPY OF ELECTRICIAN'S SURVEY REPORT RE. ELECTROLYSIS PROBLEMS.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Electrical
Issued 30 May 1987 Resolved
INSTALL COVER TO ELECTRICAL SWITCHBOARD ON AFT ENGINEROOM BULKHEAD.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Electrical
Issued 30 May 1987 Resolved
REPAIR/REPLACE WATER TEMP GUAGE ON MAIN GENERATOR.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Electrical
Issued 30 May 1987 Resolved
REPAIR/REPLACE WATER TEMPERATURE AND OIL PRESSURE GUAGE TO GENERATOR ON BRIDGE CONSOLE.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Engineering
Issued 30 May 1987 Resolved
REPLACE FLAME SCREENS TO FUEL VENTS.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Engineering
Issued 30 May 1987 Resolved
REPAIR/REPLACE WATER TEMPERATURE GUAGE ON ENGINEROOM PORT MAIN ENGINE.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Lifesaving
Issued 30 May 1987 Resolved
REPAIR WATERLIGHT TO BUOYANT APPARATUS.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Lifesaving
Issued 30 May 1987 Resolved
REPLACE WEAKLINKS TO BUOYANT APPARATUS WITH PROPER SIZE WEAK-LINK.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Lifesaving
Issued 30 May 1987 Resolved
REPLACE LIFELINE TO RINGBUOY.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Documentation
Issued 7 May 1985 Resolved
PROVIDE NAVIGATION RULES OF THE ROAD BOOK.
Condition: Unknown
Due 7 May 1985
Resolved 7 May 1985
Construction/Loadline
Issued 7 May 1985 Resolved
REINSTALL ALL BOLTS IN HATCH COVERS AND TANK COVERS THROUGHOUT VESSEL.
Condition: Unknown
Due 7 May 1985
Resolved 7 May 1985
Engineering
Issued 7 May 1985 Resolved
REPAIR AS NECESSARY TO STOP LEAKING PORT AND STBD FUEL SHUT-OFF VALVES.
Condition: Unknown
Due 7 May 1985
Resolved 7 May 1985
Electrical
Issued 7 May 1985 Resolved
REMOUNT COVER ON ELECTRICAL PANEL IN ENGINE ROOM.
Condition: Unknown
Due 7 May 1985
Resolved 7 May 1985

Casualty record · 6

10 July 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1877012
16 May 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2079046
6 June 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3772861
22 May 2011Routine · role: Transiting Vicinity of Primary Subject · activity 4019950
18 June 2011Routine · role: Moored/Anchored in Vicinity of Primary Subject · 1 injured · activity 4051326
27 April 2026Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8382120
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.