MAURY USCG vessel records Sign in
← All vessels

BUYER

BUYER is a 1962 freight ship. The Coast Guard has recorded 27 inspections since 1987, most recently in May 2008, along with 31 deficiencies.

Records from 1987 to 2008. Most recent: inspection, 27 May 2008.

Built
1962
Last inspected
27 May 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5111036 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
366329000 (licence lapsed)
Maury page id
psix-44252

Inspections, by type

…with no type recorded6
Years with a record 9 calendar years (1987–2008)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10659 - Regulatory (Subpart C or D), Gross Ton
6465 - Regulatory (Subpart C or D), Net Ton
7939 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KCAOMMSI 366329000 · expired · compulsorily equipped · granted 17 October 1991, cancelled 17 October 1996
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DIAMOND STATE Freight Ship · MISLE 44245 · 8 April 1993 · activity 116030

Inspection history · 27

27 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3219476
4 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087176
26 January 1994 Damage Survey · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1362949
4 January 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 853823
19 October 1993 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407219
5 August 1993 Permit to Proceed
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847213
30 July 1993 Permit to Proceed
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1153002
23 July 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1443397
8 April 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 116030
21 October 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 938807
26 September 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 495521
15 August 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 122818
22 July 1992 Drydock Extension · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1264815
10 May 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 131540
24 January 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1260286
2 December 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255811
6 November 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 182925
10 October 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 939862
20 August 1991 Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250692
24 April 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249720
23 April 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249159
25 March 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 998210
23 May 1990 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 919195
23 May 1990 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1228965
16 March 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1336419
11 January 1988 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1021839
24 July 1987 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1331409

Deficiency record · 31

Construction/Loadline
Issued 26 January 1994 Resolved
COMPLETE REPAIRS AND MAKE READY FOR HOSE TEST OF #3, #5, AND #6 CARGE HATCH COVERS.
Condition: Unknown
Due 28 February 1994
Resolved 4 April 1994
Electrical
Issued 26 January 1994 Resolved
PROVIDE ABS APPROVED PLANS AND CERTIFICATION OF VESSELS EMERGENCY DIESEL ENGINE.
Condition: Unknown
Due 31 March 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 23 July 1993 Resolved
PROVIDE APPROVED CATHODIC INSTALLATION PLANS IN ACCORDANCE WITH NVIC 10-92 TO COMMANDANT, MARINE SAFETY CENTER, WASHINGTON, D.C.. INSTALLATION WAS WITNESSED BY MSO MOBILE INSPECTORS IAW NON-APPROVED DESIGN PLANS AND WATERTIGHT TESTING COMPLETED SATISFACTORILY, BY 30 SEPT 93_x001C_
Condition: Unknown
Due 23 July 1993
Resolved 23 July 1993
Construction/Loadline
Issued 23 July 1993 Resolved
COMPLETED REPAIRS (PERMANENT) IN WAY OF VESSELS GALLEY/TRASHROOM, STBD SIDEBETWEEN FRAMES 159 1/2 TO 162 1/2, REPAIRS APPROXIMATELY 9FT X 10FT TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR BY 30 SEP 93_x001C_
Condition: Unknown
Due 23 July 1993
Resolved 23 July 1993
Engineering
Issued 22 July 1992 Resolved
THE SHIPS SERVICE AIR RECIEVER SHALL BE EXAMINED INTERNALLY BY A MARINE INSPECTOR.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Engineering
Issued 22 July 1992 Resolved
THE MOUNTS ON THE PORT BOILER SHALL BE OPENED FOR EXAMINATION BY A MARINE INSPECTOR.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Engineering
Issued 22 July 1992 Resolved
MAKE OPERATIONAL THE POWER OPERATED MAIN CONDENSER OVERBOARD DISCHARGE SEA VALVE.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Engineering
Issued 22 July 1992 Resolved
PLACE A NAME/DATA PLATE ON THE PORT AND STARBOARD BOILER.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Navigation
Issued 22 July 1992 Resolved
MAKE OPERATIONAL THE AUXILIARY STEAM WHISTLE PULL ON THE BRIDGE.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Fire Fighting
Issued 22 July 1992 Resolved
HAVE THE SMOKE DETECTION SYSTEM SERVICED BY AN AUTHORIZED SERVICE REPRESENTATIVE.
Condition: Unknown
Due 7 August 1992
Resolved 7 August 1992
Fire Fighting
Issued 22 July 1992 Resolved
HAVE THE FIXED CO2 SYSTEMS SERVICED BY AN AUTHORIZED SERVICING REPRESENTATIVE.
Condition: Unknown
Due 7 August 1992
Resolved 7 August 1992
Engineering
Issued 22 July 1992 Resolved
THE MOUNTS ON THE STARBOARD BOILER SHALL BE OPENED FOR INSPECTION BY A MARINE INSPECTOR.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Construction/Loadline
Issued 22 July 1992 Resolved
CROP AND RENEW AS ORIGINAL THE OVERBOARD DISCHARGE PIPING FROM NUMBER 1A PORT WATER BALLAST TANK.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Engineering
Issued 22 July 1992 Resolved
THE D.C. HEATER SHALL BE INTERNALLY EXAMINED BY A MARINE INSPECTOR.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Fire Fighting
Issued 22 July 1992 Resolved
CALIBRATE THE FIRE PUMP PRESSURE GUAGE AT THE THE FIRE PUMP IN THE ENGINE ROOM.
Condition: Unknown
Due 6 August 1992
Resolved 6 August 1992
Construction/Loadline
Issued 22 July 1992 Resolved
CROP AND RENEW AS ORIGIONAL THE OVERBOARD DISCHARGE PIPING FROM NUMBER 1A STARBOARD WATER BALLAST TANK.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Engineering
Issued 22 July 1992 Resolved
MAKE OPERATIONAL THE POWER OPERATED MAIN CIRCULATION LOW SUCTION SEA VALVE.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Engineering
Issued 2 December 1991 Resolved
PROVER PROPER OPERATION OF PORT AND STBD BOILER SAFETY RELIEF VALVES (WITH EXCEPTION OF PORT BOILER FWD DRUM VALVE) TO THE SATISFACTION OF U.S. COAST GUARD MARINE INSPECTOR PRIOR TO LEAVING ROTA SPAIN.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Accommodation/Occupational Safety
Issued 2 December 1991 Resolved
MAKE PERMANENT CLOSURE TO PAINT LOCKER (DECK) BULKHEAD AND ELECTRICAL FAN ROOM AT EARLIEST CONVENIENCE TO THE SATISFACTION OF A.C.G. MARINE INSPECTOR.
Condition: Unknown
Due 2 December 1991
Resolved 2 December 1991
Documentation
Issued 24 April 1991 Resolved
PROVIDE TO [name withheld] OF PROPER CARGO GEAR MAINTENANCE IAW 46 CFR 91.37-5, AND 91.25-25(C)
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Documentation
Issued 24 April 1991 Resolved
PROPERLY POST OIL TRANSFER PROCEDURES IAW 33 CFR 155.740 AND 155.720.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Documentation
Issued 24 April 1991 Resolved
PROVIDE TO [name withheld] OF ABS REPORT ON ECONOMIZER REPAIRS COMPLETED IN ROTA, SPAIN IN APRIL 1991.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 24 April 1991 Resolved
DEMONSTRATE PROPER OPERATION OF SMOKE DETECTION SYSTEM.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 24 April 1991 Resolved
PRIOR TO DEPARTURE NEXT U.S. PORT REPLACE NON C.G. APPROVED CO2 FIRE EXTINGUISHERS WITH C.G. APPROVED ONES.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Lifesaving
Issued 24 April 1991 Resolved
UPON ARRIVAL NEXT U.S. PORT REPLACE SOLAS APPROVED LIFEBOAT RATIONS WITH C.G. APPROVED RATIONS.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Accommodation/Occupational Safety
Issued 24 April 1991 Resolved
MAKE PERMANENT CLOSURE TO PAINT LOCKER (DECK) BULKHEAD AND ELECTRICAL FAN ROOM AT EARLIEST CONVENIENCE TO THE SATISFACTION OF A C.G. MARINE INSPECTOR.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Electrical
Issued 23 April 1991 Resolved
PROPERLY CHANGE OUT EMERGENCY GENERATOR FEEDER CABLE THOF-400 WITH AN ACCEPTABLE NON FLEXING CABLE IAW 46 CFR 111.60-13 PRIOR TO DEPARTURE NEXT U.S. PORT OR NLT 6 MONTH TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Electrical
Issued 23 April 1991 Resolved
PROVIDE NECESSARY PLANS IAW 46CFR 110.25 TO [name withheld] GENERATORMODIFICATION - INSTALLATION.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Electrical
Issued 23 April 1991 Resolved
PROVIDE TO [name withheld], ABS CERTIFICATION OF BOTH THE GENERATOR AND MOTORDIESEL INSTALLATION RATED AT 184 K.W. CONTINUOUS. SEE 46CFR 58.10 AND_x001C_ 111.12-5.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Electrical
Issued 23 April 1991 Resolved
PROPERLY RESET GENERATOR CIRCUIT BREAKER TRIP SETTING TO EMERGENCY SWITCH BOARD PRIOR TO DEPARTURE NEXT U.S. PORT OR NLT 6 MONTHS FROM THIS DATE TO COMPLY WITH 46CFR111.10-11 AND 111.12-11.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Electrical
Issued 23 April 1991 Resolved
MAKE EMERGENCY GENERATOR [name withheld] DECK A PROPERLY REINFORCED A-60 BOUNDARY.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991

Ownership record