MAURY USCG vessel records Sign in
← All vessels

COUNTESS

COUNTESS is a 1962 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1985, most recently in June 2026, along with 62 deficiencies and 9 casualty investigations between 2002 and 2026.

Records from 1985 to 2026. Most recent: inspection, 2 June 2026.

Built
1962
Last inspected
2 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI3442
Flag
UNITED STATES
367688360
Maury page id
psix-44257

Inspections, by type

…with no type recorded19
Years with a record 37 calendar years (1985–2026)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.8 ft × 16.0 ft × 3.8 ft
Registered tonnagegross 32 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUBUQUE BOAT & BOILER CO · DUBUQUE, IA, UNITED STATES · built 1962
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPITTSBURGH, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI3442MMSI 367688360 · active · compulsorily equipped · granted 20 May 2025, expires 14 August 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PRINCESS Passenger (Inspected) · MISLE 229958 · 18 June 2002 · activity 1654484

Inspection history · 87

2 June 2026 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8392558
23 April 2026 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8355140
23 April 2026 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8356605
17 April 2026 Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8352488
17 April 2026 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8354086
25 March 2026 COI Inspection · DAPI Audit · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8331577
18 February 2026 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8311920
2 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8253185
23 June 2025 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8165154
20 April 2024 Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7899502
19 April 2024 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7934248
31 August 2023 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7781947
25 August 2023 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7787044
16 May 2023 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7680198
16 May 2023 DAPI Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7695752
29 August 2022 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7546366
25 July 2022 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7516337
17 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7452882
21 March 2022 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7414237
15 April 2021 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7175825
17 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7096810
26 May 2020 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6972910
18 April 2019 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6665520
13 June 2018 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6442995
13 June 2018 Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6443001
7 June 2018 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6455020
8 May 2018 Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6411005
31 July 2017 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6226272
29 July 2017 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6226250
17 April 2017 Annual Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6127565
16 May 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5878341
9 May 2016 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5873587
25 April 2016 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5868126
27 June 2014 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4908637
13 May 2014 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4857208
15 September 2011 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4149708
19 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3241451
27 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3218656
7 May 2008 In-Service Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3200911
24 September 2007 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3071013
8 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2924913
20 February 2007 Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2874897
20 February 2007 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2887848
11 July 2006 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2715988
10 July 2006 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2710405
6 April 2006 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2616105
16 October 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2516219
30 July 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2447669
10 July 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2447558
25 April 2005 In-Service Inspection · Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2350849
30 March 2005 Deficiency Check · Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2322802
4 October 2004 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2226018
6 May 2004 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2060049
1 October 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1937474
26 August 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1887334
12 June 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1841514
7 May 2003 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1788144
18 June 2002 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1654484
22 May 2002 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1619104
12 March 2002 Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1598563
15 May 2001 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1452821
17 May 2000 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1427829
7 December 1999 Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1423297
17 August 1999 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1378802
25 May 1999 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 799697
22 May 1998 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1472849
28 May 1997 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1421369
5 May 1997 Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1437235
25 March 1997 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1104718
21 May 1996 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1081904
23 May 1995 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1402043
25 May 1994 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 854712
20 January 1994 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1161492
22 December 1993 Damage Survey
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 849009
19 December 1993 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 87594
26 May 1993 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1152930
27 May 1992 COI Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1266395
8 May 1991 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1233246
9 May 1990 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1218433
4 May 1989 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1210787
26 April 1988 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1343549
4 May 1987 Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1335908
28 April 1987 Re-Inspection · Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1023698
31 July 1986 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1303711
5 May 1986 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1292940
8 May 1985 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1286134
23 April 1985 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1291365

Deficiency record · 62

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2026 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. The generator experienced a failure and needed to be secured. Repair/replace generator.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2026
Resolved 8 May 2026
Resolution: Sea chest was relocated and operational test conducted. Generator operated without overheating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2026 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. The generator experienced a failure and needed to be secured. Repair/replace generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2026
Resolved 22 April 2026
Resolution: Attended vessel to confirm satisfactory repair. Sea chest grating was obstructed with scale and paint.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2026 Resolved
One length of fire hose shall be provided for each fire hydrant required. If garden hose is used, it shall be of a good commercial grade constructed of an inner rubber tube, plies of braided cotton reinforcement and an outer rubber cover. Replace garden fire hose, found to be kinked and deteriorating. 46 CFR 181.20-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 22 April 2026
Resolution: Attended vessel and hose was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2026 Resolved
All life preservers shall be of an approved type. 07 life jackets found no longer serviceable and deteriorated 46 CFR 180.25-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 22 April 2026
Resolution: Lifejackets have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Starboard engine suffered fracture of the engine block and unknown degree of internal damage. Repair or replace as required. Upon completion of repairs, conduct operational test in the presence of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2026
Resolved 24 April 2026
Resolution: This deficiency is being closed. Vessel has been repowered.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 August 2023 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Generator engine experienced failure. Complete repairs or replace. If replacement is made that is not in-kind, ensure replacement meets new standards IAW 46 CFR 176.700 and 46 CFR 183.320.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2023
Resolution: Replaced generator with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2023 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Exhaust leaks found at both propulsion engine turbo charges and on muffler. Repair exhaust leaks as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 31 August 2023
Resolution: Repaired exhaust leaks
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2022 Resolved
Installation of diesel engine exhaust pipe shall be in accordance with §182.15-15. (a) Except as otherwise provided in this paragraph, all engine exhaust pipes shall be water cooled. (1) Dry pipe vertical exhausts are permissible if suitably insulated. Exhaust pipe insulation found to be not suitable for marine use. Remove and install insulation suitable for marine/engine room use.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 29 August 2022
Resolution: Applied metal shielding around insulation on exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 May 2022 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold must be water-jacketed or effectively insulated and protected in compliance with §§ 177.405(b) and 177.970 of this chapter. Dry exhaust on both propulsion engines between manifold and turbocharger missing insulation. Add insulation as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 July 2022
Resolution: Installed insulation as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 May 2022 Resolved
Exhaust gas must not leak from the piping or any connections. Port engine leaking exhaust. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 July 2022
Resolution: Exhaust muffler was found to have a hole in it. Welded hole and re-installed with no new leaks.
Construction/Loadline › Structures › Deck Plating
Issued 9 May 2018 Resolved
Crop out to good metal the affected areas identifed by the attending MI and renew deck plating to original condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2018
Resolved 6 June 2018
Engineering › Steering Gear System › Linkage
Issued 31 July 2017 Resolved
Coupling that links steering shaft to rudder pulley assembly sheered. Remove broken coupling and replace with new to original condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2017
Resolution: Replace coupling with new.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 April 2017 Resolved
Utilization of screw type wire nuts for electrical connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2017
Resolved 28 April 2017
Resolution: screw type nuts removed
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 17 April 2017 Resolved
Using the hull of the vessel to make a circuit for the bilge alarm system
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2017
Resolved 28 April 2017
Resolution: wired circuit properly
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 17 April 2017 Resolved
Dry exhaust piping missing lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2017
Resolved 28 April 2017
Resolution: exhaust pipe lagged
Electrical › Electric Supply System (service) › Cable
Issued 17 April 2017 Resolved
Permanently installed extension cords installed in the engine room
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2017
Resolved 28 April 2017
Resolution: removed extention cords
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 April 2017 Resolved
110V electrical outlet box lying in the bilge
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2017
Resolved 28 April 2017
Resolution: mounted outlet box properly
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 May 2016 Resolved
Battery must be replaced in accordance with annual replacement requirement
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2016
Resolved 20 June 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 May 2016 Resolved
Retro reflective tape was inadequate ammount and coverage
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2016
Resolved 20 June 2016
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 May 2016 Resolved
Lifejackets were stowed in a way that the straps were not readily adjustable. Service and restow
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2016
Resolved 22 June 2016
Documentation › Certificates/Documents › Stability Letter
Issued 16 May 2016 Resolved
Reinstall missing bench seating in accordance with approved passenger count.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2016
Resolved 22 June 2016
Construction/Loadline › Hull › Bottom Plating
Issued 25 April 2016 Resolved
Repair fracture in way of framing under the port engine
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2016
Engineering › Reduction Gearing/Clutches › Hose
Issued 13 May 2014 Resolved
Starboard Reduction gear line was worn/leaking. Vessel must replace line.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 27 June 2014
Lifesaving › Lifejacket/PFD (Type IV) › Lights
Issued 13 May 2014 Resolved
Float light on lifering was inoperatble. Vessel must fix or repair.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 27 June 2014
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 13 May 2014 Resolved
Ship Service Generator has visible leaks. Vessel must address and repair all leaks.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 27 June 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 May 2014 Resolved
Vessel has not paid COI user fees. Vessel must provide proof of user fee payment.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 15 May 2014
Resolution: Vessel provided receipt from USCG FINCEN that user fees had been paid in full.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 May 2014 Resolved
The aft Starboard overhead light for the p[assenger area is extinguished. Vessel must repair light.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 27 June 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2014 Resolved
Medications are expired or missing in ship's first aid kit. Vessel must replace all missing and expired medication.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 27 June 2014
Deck/Cargo › Mooring/Anchoring › Winch
Issued 13 May 2014 Resolved
Shackles on Ganway winch cable were not properly secured. Vessel must secure cable with mousing wire.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 27 June 2014
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 13 May 2014 Resolved
Port Lube oil Pressure gague is inoperable. Vessel must fix ro replace gague.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 27 June 2014
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 13 May 2014 Resolved
Starboard Engine Coolant Gaghue is inoperable. Vessel must fix or replace gague.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 27 June 2014
Fire Fighting › Fire Pumps › Casing
Issued 20 February 2007 Resolved
DEWATER ENGINE ROOM, REPLACE FIRE PUMP AND PROVE OPERATION OF ALL ENGINE ROOM SYSTEMS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2007
Resolved 12 March 2007
Resolution: CORRECTED
Construction/Loadline › Hull › Bottom Plating
Issued 10 April 2006 Resolved
Crop and renew to good metal stern void bottom plate and associated internals.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2006
Resolution: All stern void bottom plate renewed, forward 9'' of the eight bottom longs (from stbd side) renewed in stern void, lower 18" of fwd stern void bulkhead renewed, and all but the upper 16" of the port and stbd side shell in the stern void renewed - sat.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 10 April 2006 Resolved
Prove flexible hose used in fuel tank fill pipes is an USCG Type A1, A2, B1, or B2 hose.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2006
Resolution: USCG Type A-2 hose installed in fuel fills.
Fire Fighting › Ventilation Systems › Ducts
Issued 6 April 2006 Resolved
Magnetic closures on engineroom vent dampers ineffective, prove proper operation of vent damper closures.
Action required: 705 - Other - as specified
Due 6 May 2006
Resolved 10 April 2006
Resolution: Mechanical closures installed - sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 April 2006 Resolved
Renew stern void bilge hi-level alarm and prove proper operation
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 April 2006 Resolved
Make method of access to PFDs stowed beneath pilot house self-evident to allow immediate access.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2006
Construction/Loadline › Hull › Bottom Plating
Issued 6 April 2006 Resolved
Provide a gauging report for stern tubes and stern void bottom plate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2006
Navigation › Piloting/Steering › Marine Charts
Issued 30 March 2005 Resolved
Provide current navigaton charts.
Due 30 April 2005
Resolved 25 April 2005
Resolution: New charts on board.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 30 March 2005 Resolved
Double clamp all hoses in vital systems.
Due 30 April 2005
Resolved 8 April 2005
Resolution: All hoses double clamped wherever possible.
Electrical › Electrical Distribution System (service) › Cable
Issued 30 March 2005 Resolved
Remove dead end cable from old water pump installation.
Due 30 April 2005
Resolved 31 March 2005
Resolution: Dead end cable removed.
Engineering › Bilge Water Management System › Not Operational
Issued 30 March 2005 Resolved
Prove proper operation of engine room port side bilge high-level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2005
Resolution: Float switch renewed - tested sat.
Engineering › Fuel Oil Service System › Piping
Issued 30 March 2005 Resolved
Secure the fuel return lines from both MDEs against movement, vibration, and chaffing.
Due 30 April 2005
Resolved 8 April 2005
Resolution: Lines secured and caffing gear installed.
Navigation › Piloting/Steering › Marine Charts
Issued 6 May 2004 Resolved
Provide a current Ohio River chart (2003).
Condition: Improper/Lack of Maintenance
Due 6 June 2004
Resolved 7 May 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 May 2004 Resolved
Prove contents of first aid kit include all required items.
Condition: Improper/Lack of Maintenance
Due 6 June 2004
Resolved 6 June 2004
Resolution: Aspirin and a splint were added to the kit.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 6 May 2004 Resolved
Renew retroreflective tape as needed on lifejackets
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Resolution: All loose and worn retroreflective tape on lifejackets was renewed.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 6 May 2004 Resolved
Renew fuel tank flame screens.
Condition: Improper/Lack of Maintenance
Due 6 June 2004
Resolved 7 May 2004
Communications › Radio Communications
Issued 7 May 2003 Resolved
The emergency broadcast placard was missing - corrected on scene.
Condition: Improper Installation
Due 7 May 2003
Resolved 7 May 2003
Resolution: A broadcast placard was brought on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2003 Resolved
First aid kit missing aspirin and a splint - corrected on scene.
Condition: Improper/Lack of Maintenance
Due 7 May 2003
Resolved 7 May 2003
Resolution: Aspirin and a splint were added to kit from supplies ashore.
Fire Fighting › Ventilation Systems › Ducts
Issued 7 May 2003 Resolved
Prove proper operation of engine room vent stops.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Resolution: Each of the four engine room vents had a newly installed hinged flap style cover.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 7 May 2003 Resolved
Remove all waste receptacles that are NOT non-combustible from the vessel. LEGACY COMPONENT DESC: Waste Receptacles
Condition: Placed in Improper Service
Due 1 October 2004
Resolved 4 October 2004
Resolution: Combustible trashcans removed. Metal trashcans in use now.
Pollution Prevention/Response › Prevention Equipment
Issued 7 May 2003 Resolved
Renew deck connection for starboard sewage tank vent line and reconnect both vent lines. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper/Lack of Maintenance
Due 7 June 2003
Resolved 12 June 2003
Resolution: New line installed.
Construction/Loadline
Issued 21 May 1996 Resolved
INSTALL BILGE HIGH LEVEL ALARMS ON ALL GATEWAY VSLS, IAW NEW REGULATIONS.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
WIRE SIEZE ALL SHACKLE PINS ON GANGWAY ATTACHMENT POINTS.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 21 May 1996 Resolved
PLUG UNUSED STUFFING TUBE UNDER PILOT HOUSE.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Navigation
Issued 21 May 1996 Resolved
REPLACE WHITE STERN LIGHT WITH A CG APPROVED STERN LIGHT. EXISTING LIGHT ISDIM DUE TO FOGGING OF THE LENS.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Fire Fighting
Issued 21 May 1996 Resolved
INSTALL PROPER ON/OFF SWITCH FOR THE FIRE/BILGE PUMP. USING THE CIRCUIT BREAKER IS UNSAT.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 21 May 1996 Resolved
CAPTAIN/CREW MUST GIVE VERBAL PASEENGER SAFETY ORIENTATION IAW NEW REGULATIONS.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Engineering
Issued 22 December 1993 Resolved
Prove proper operation of replacement propeller upon installation.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Navigation
Issued 5 May 1986 Resolved
INSTALL ON BOARD A STERN LIGHT SHOWING THE PROPER CHARACTERISTICS.
Condition: Unknown
Due 5 May 1986
Resolved 5 May 1986
Construction/Loadline
Issued 23 April 1985 Resolved
CLEAN ALL VOID COVER GASKET SURFACES ENTIRE VESSEL. REPLACE MISSING ENGINEROOM HATCH GASKET.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Electrical
Issued 23 April 1985 Resolved
PROPERLY SECURE STARTING BATTERY FOR SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985

Casualty record · 9

18 June 2002Routine · role: Involved in a Marine Casualty · activity 1654484
20 February 2007Routine · role: Involved in a Marine Casualty · activity 2887848
10 June 2009Routine · role: Involved in a Marine Casualty · activity 3500935
29 July 2017Routine · role: Involved in a Marine Casualty · activity 6226250
7 June 2018Routine · role: Involved in a Marine Casualty · activity 6455020
25 August 2023Routine · role: Involved in a Marine Casualty · activity 7787044
19 April 2024Routine · role: Involved in a Marine Casualty · activity 7934248
17 April 2026Routine · role: Involved in a Marine Casualty · activity 8354086
23 April 2026Routine · role: Involved in a Marine Casualty · activity 8356605
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GOOD SHIP LOLLIPOP (2002–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record