Records from 1996 to 2026. Most recent: inspection, 9 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 82
9 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8323298
20 March 2025
Administrative Inspection · COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8097233
22 April 2024
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7899461
27 February 2024
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7874343
26 September 2023
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7852817
15 March 2023
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7651455
21 February 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7644738
17 November 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7597398
9 February 2022
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7393800
30 June 2021
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7247949
7 June 2021
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7218248
26 January 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7154402
23 November 2020
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7100989
23 November 2020
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7102087
1 September 2020
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7047429
16 July 2020
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7007559
10 July 2020
Damage Survey
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7002737
6 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6936126
17 March 2020
COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6928013
31 January 2020
Construction Oversight
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6900711
6 January 2020
Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7067548
20 March 2019
Periodic Inspection · Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6650708
20 February 2018
Annual Inspection · MTSA Verification
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6358323
6 April 2017
Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6121721
15 March 2017
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6086307
7 February 2017
Internal Structural Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6083929
30 November 2016
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 6049765
30 August 2016
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 6380271
29 June 2016
Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5925293
1 March 2016
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5830343
9 April 2015
MTSA Verification
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5100346
2 March 2015
COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5064772
2 March 2015
COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5066874
12 June 2014
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4891242
14 February 2014
Re-Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4803673
16 March 2012
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4267592
15 September 2011
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4146787
15 September 2011
Damage Survey
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4147089
9 February 2010
COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3677649
1 April 2009
Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3447850
3 March 2009
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3426325
25 March 2008
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3169180
2 March 2007
Annual Inspection · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2880844
9 November 2006
Hull Examination
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2817492
13 August 2006
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2748696
25 June 2006
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2953474
31 May 2006
Internal Structural Exam
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2664711
31 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2666291
5 May 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2659679
8 April 2006
Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2621204
2 March 2006
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2589426
24 March 2005
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2283917
18 April 2004
Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2160834
14 April 2004
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2044421
10 March 2004
Periodic Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2017427
23 February 2004
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2011695
2 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999972
17 March 2003
In-Service Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1785295
23 May 2002
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1617720
25 June 2001
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1465044
31 May 2001
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1425130
4 February 2001
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1059001
15 May 2000
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1389089
25 February 2000
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 819945
19 January 2000
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 66009
9 November 1999
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 804356
6 July 1999
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1399147
23 March 1999
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 173480
7 January 1999
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1336961
6 January 1999
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 810591
1 January 1999
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 15479
18 July 1998
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 800280
30 June 1998
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1400824
29 June 1998
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 792532
25 February 1998
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 778456
31 October 1997
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 781492
10 October 1997
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 777706
2 October 1997
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1119988
9 September 1997
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 786169
13 May 1997
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1106514
2 December 1996
Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1185183
31 July 1996
Deadweight Survey · COI Inspection · Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1090649
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 March 2026
Resolved
The inspector will determine that all fixed equipment is in suitable condition. The 30 sec time delay for the fixed CO2 system protecting engine room was outside of allowed limits.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 24 March 2026
Resolution: Fixed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 March 2023
Resolved
Containers, brackets, racks, and other similar stowage locations for lifesaving equipment must be marked with symbols indicating the device stowed in that location. The markings/symbols were faded and illegible on the container used for stowage of the immersion suits and Type I PFDs on the upper forward deck. Renew markings as appropriate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2023
Resolved 13 March 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 March 2021
Resolved
Semi Portable CO2 fire extinguisher hose assembly is damaged. Place hose out of service and place adequate temporary extinguishers in place.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 7 June 2021
Resolution: email confirmation from company received.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 March 2021
Resolved
Liferaft launching placard is worn. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 9 April 2021
Resolution: Placard has been replaced
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 11 March 2021
Resolved
Posted Fire Control Plan is worn. Make readily visible to crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 9 April 2021
Resolution: Plexi glass cover for fire control plan was cleaned and plan is clearly visible.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 11 March 2021
Resolved
Bow thruster exhaust vent gasket found to be covered with paint. Ensure watertight and weathertight closing devices are kept free from paint and cargo residues
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 9 April 2021
Resolution: Gaskets and closing devices on the forward portion of the barge have been renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 March 2021
Resolved
Bilge suction strainers were found to be surrounded by cargo residues and not maintained in a ready condition. Keep bilge suction arrangements ready for use and prove operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 9 April 2021
Resolution: Area around suction strainers have been cleared of cargo residue.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 March 2021
Resolved
Heat activated detectors appeared to have flame related damage and have since been replaced and properly tested. Ensure these devices are tested and maintained in accordance with manufacturer's recommendation, and that the crew is properly trained on their operation so as not to test them with an open flame, rendering them inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 9 April 2021
Resolution: Heat activated devices were all replaced an properly tested by CertaSite. Company will require testing with a hot water pot and will no longer allow open flame testing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 November 2020
Resolved
Due to the fire, fire fighting equipment was used, including fire extinguishers. Prior to cargo operations and operation of the starboard unloading generator, all fire fighting equipment shall be refilled and serviced by a fire servicing company to the satisfaction of the attending CG Marine Inspector
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 24 November 2020
Resolution: Fire extinguishers were returned to vessel and serviced by a fire servicing company. Vessel has equipment onboard per COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2020
Resolved
During the fire, soot and smoke was present in the space. Prior to operation of the starboard unloading generator a servicing technician shall inspect and verify the starboard unloading generator is safe for operation. In addition, in the generator housing, it was discovered that rope was being used to support cables. The vessel shall replace the rope with suitable supports IAW manufacturer guidelines. All of the above items shall be completed prior to the operation of the generator and to the satisfaction of the attending CG Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 24 November 2020
Resolution: Air filters replaced, generator inspected, new hangers for cable installed, and op tested with CAT Rep.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2019
Resolved
Provide 6 Type I PFDs on barge for conditional occupancy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2019
Resolution: PFDs have been placed on the barge for conditional occupancy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2019
Resolved
Provide ring buoy light to satisfy conditional occupancy requirements
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2019
Resolution: Ring buoy light provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 March 2019
Resolved
Watertight door port aft leading to generator space and deck hatch aft/midships requires new gaskets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2019
Resolved 9 May 2019
Resolution: Gaskets installed and replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 March 2019
Resolved
Prevent overhead light cover in emergency generator room from exposure to excessive heat from adjacent space heater.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 10 May 2019
Resolution: Heater has been reconfigured with a deflector to direct heat away from overhead light cover.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 March 2019
Resolved
The e-lighting was not sufficent and/or not properly marked. Properly repair and mark e-lighting throughout the vessel to allow adequate illumination for a safe escape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 10 May 2019
Resolution: Adequate e-lighting provided throughout vessel.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 20 March 2019
Resolved
Prove proper operation of remote break glass ventilation shutdowns.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 10 May 2019
Resolution: Remote ventilation shutdowns verified.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 March 2017
Resolved
Fire door in fwd machinery space to workshop was fitted with a hold back device. Remove same and label door "Keep Closed".
Due 31 March 2017
Resolved 15 March 2017
Resolution: Hold back device removed and door was properly labeled.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 March 2017
Resolved
Fire door in fwd machinery speace to ladder/stair well with auto cloing device did not fully close due to a plate installed in door jam latch receiver. Remove preventer plate and prove proper closure.
Due 15 March 2017
Resolved 15 March 2017
Resolution: Preventer plate was removed and door properly closed and latched.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 1 March 2016
Resolved
Paint cans and paint thinner were stowed at fwd workbench and not properly stored in paint locker.
Due 2 March 2016
Resolved 2 March 2016
Resolution: properly stowed in paint locker prior to departure
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 March 2016
Resolved
Flush bolted access plate for Aux Generator installation of transverse overhead deck beam did not comply with approved plan, (Netsco Dwg No J6621-S16-2-1 Rev A).
Due 1 March 2017
Resolved 29 June 2016
Resolution: Received approved plan J6621-S16-2-1 Rev B
Electrical › Electric Generation Source (service) › Generator
Issued 1 March 2016
Resolved
Generator renewal performed and tests for overspeed, HJWT, and LLOP shutdown not demonstrated. Prove proper operation of SS generator shutdowns.
Due 30 June 2016
Resolved 29 June 2016
Resolution: Received report of survey from operator indicating ABS surveyor attended satisfactory testing of operation and automatic shutdowns.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2015
Resolved
Electrical power supply cable to air dryer compressor #3 is not approved typw. Renew same with approved type in accordance with 46 CFR 111.60-3.
Due 2 April 2015
Resolved 24 March 2015
Resolution: Renewed with proper cable application with low smoke insulation.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 2 March 2015
Resolved
Remote emergency shutdown "breakglass" for port unloading generator not operating. Prove proper operation of same.
Due 2 April 2015
Resolved 24 March 2015
Resolution: Test of both P & S engine shutdowns functioned properly.
Electrical › Electrical Distribution System (service) › Cable
Issued 2 March 2015
Resolved
Electrical power supply cable to #3 air dryer compressor is not an approved type. Renew same with approved type.
Due 2 April 2015
Resolved 2 April 2015
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 16 March 2012
Resolved
Make Repairs to Forward Stbd Side Machinery/Tunnel High Bilge alarm as required by 46 CFR 62.50
Action required: 705 - Other - as specified
Due 11 April 2012
Resolved 5 April 2012
Resolution: Received an e-mail from Company rep stated fwd bilge alarm working, apparently it is the type of sensor that has to be tested with water. CG-835 cleared.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2011
Resolved
Provide Class (ABS) survey report of inspection for damage subsequent to report of grounding. Class survey to be conducted at first port call (Alpena, MI), and report to be submitted to [name withheld]. Survey report to be acceptable to attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2011
Resolved 17 September 2011
Resolution: ABS attended and Report of damage survey submitted
Stability › Watertight Integrity › General
Issued 9 February 2010
Resolved
Provide documentation the vessels installed non metallic expansion joints were replaced within 10 years of being placed in service IAW 46 CFR 61.15-12(b). The vessel has 8 non metallic expansion joints in the ballast pump system. Extended until next dry-dock (Dec 2012)- see activity # 3677649 for details.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2012
Resolved 4 April 2012
Resolution: Viewed and Verified all non-metallic joints were renewed
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 3 March 2009
Resolved
Provide a plan for approval IAW 46CFR 110.30-7 to remove the temporary power sources for the following permanently mounted equipment or remove the equipment from the vessel: the service water pump, conveyor belt observation close circuit camera and the electric motor heater receptacle. Currently the equipment has an extension cord plug receives power from an outlet.
Condition: Improper Installation
Due 7 May 2009
Resolved 14 April 2009
Resolution: Received an Email from the chief engineer with plan 4/07/2009. Approved plan. Received Email 4/14/2009 confirming the proposed repairs completed.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 24 March 2008
Resolved
Prior to use of de-icing unit, conduct satisfactory test of alarms and shutdowns iaw manufacturer instructions iaw 46 CFR 62.25-7.
Action required: 705 - Other - as specified
Resolved 30 April 2008
Resolution: Received email from Chief, copy Master, stating that the heater had been tested sat iaw manufacturer lockout testing procedures.
Engineering › Steam Boiler (auxiliary/waste heat) › Shell
Issued 25 April 2006
Resolved
Make auxiliary boiler/heater available for inspection, shall include a Fireside, Waterside and Hydro-static test to 1 ¼ times the maximum allowable working pressure.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 7 March 2007
Resolution: After viewing De-Icing unit it was determined a Hydro-static test, Fire Side and Water side inspection was infeasible and unwarranted, visual viewed and witnessed satisfactory operation of the unit. Cleared the CG-835. [name withheld]
Electrical › Electrical Distribution System (service)
Issued 10 March 2004
Resolved
Install auto blow downs for starting air flasks and surge hopper air flask I.A.W. 46 CFR 111.60 and IEEE 45. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2004
Resolved 14 April 2004
Resolution: 120 VAC outlets installed. All appears satisfactory.
Engineering › Freshwater System (jacketwater cooling)
Issued 23 May 2002
Resolved
Offload gensets expansion tank sight glass require protection against being broke. LEGACY COMPONENT DESC: Storage Tank
Condition: Improper Installation
Due 23 May 2002
Resolved 23 May 2002
Resolution: Installed medal rods to protect sight glass.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 23 May 2002
Resolved
Emergency escape hatch in main control room was locked closed from layup. LEGACY COMPONENT DESC: Control Room
Condition: Placed in Improper Service
Due 23 May 2002
Resolved 23 May 2002
Resolution: Removed lock.
Unknown
Issued 31 May 2001
Resolved
Submit plans for approval to USCG Marine Safety Center as per 46CFR91.45 for the keel cooler installation. Installation of the remote reach-rods shall be in accordance with the approved drawings and be tested to the satisfaction of the attending CG Marine Inspector.
Condition: Unknown
Due 31 May 2001
Resolved 31 May 2001
Deck/Cargo
Issued 15 May 2000
Resolved
Prove proper operation of anchor windlass to the satisfaction of the attending CG Marine Inspector prior to barge departing port of Sturgeon Bay, WI.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Fire Fighting
Issued 9 November 1999
Resolved
INSTALL A COAST GUARD APPROVED FIXED FIRE FIGHTING SYSTEM IN THE VESSEL'S AFT PAINT LOCKER. LOCKER NOT TO BE USED FOR THE STORAGE OF FLAMABLE OR HAZARDOUS MATERIALS UNTIL COMPLETE.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Electrical
Issued 6 July 1999
Resolved
PROVE PROPER OPERATION OF THE AIR SHUTDOWN ON THE VESSEL'S AUX GENERATOR UPON ACTIVATION OF THE LOCAL EMERGENCY SHUTDOWN SYSTEM.
Condition: Unknown
Due 6 August 1999
Resolved 7 July 1999
Fire Fighting
Issued 6 July 1999
Resolved
INSTALL A COAST GUARD APPROVED FIXED FIRE FIGHTING SYSTEM FOR THE VESSEL'S AFT PAINT LOCKER.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Construction/Loadline
Issued 6 January 1999
Resolved
WHILE IN MILWAUKEE, WI OOA 7JAN99, MAKE FOREPEAK AVAILABLE FOR INSPECTION BY MSO MILWAUKEE. IF MSO MILWAUKEE UNABLE TO ATTEND, PROVIDE THIS OFFICE WITH A WRITTEN REPORT NLT 13JAN99 ON CONDITION OF FOREPEAK. REQUIREMENT ISSUED DUE TO GROUNDING WHILE DAPRTING LEFARGE CEMENT IN ALPENA, MI.
Condition: Unknown
Due 6 January 1999
Resolved 6 January 1999
Electrical
Issued 30 June 1998
Resolved
PROVE PROPER OPERATION OF BOTH MAIN DIESEL GENERATOR AND AUX DIESEL GENERATOR REMOTE SHUTDOWNS.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Electrical
Issued 9 September 1997
Resolved
Install covers for fuses in anchor drop fuse panel.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Accommodation/Occupational Safety
Issued 9 September 1997
Resolved
Affix a label to the emergency escape ladder in the cargo control room.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Electrical
Issued 9 September 1997
Resolved
Eliminate ground in 480V circuit.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Accommodation/Occupational Safety
Issued 31 July 1996
Resolved
Provide adequate means for access to barge from tug JACKLYN M.
Condition: Unknown
Due 31 July 1996
Resolved 31 July 1996