Records from 1984 to 2019. Most recent: inspection, 10 July 2019.
Inspection history · 64
10 July 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6744495
10 July 2018
Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6474282
25 July 2017
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6220427
1 August 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5956920
10 May 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5874662
17 December 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5783637
10 August 2015
Administrative Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5211751
7 August 2015
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5208574
2 October 2014
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4996995
3 June 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4879570
30 October 2013
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4744635
13 November 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4483152
12 August 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4113460
9 July 2010
Internal Structural Exam · MTSA Verification · Cargo Tank Internal · COI Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3787463
10 July 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3528266
3 June 2008
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3220605
7 June 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2954618
27 September 2006
Deficiency Check · MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2787111
20 March 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2627265
22 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2590026
17 June 2005
Internal Structural Exam · COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2393744
20 October 2004
Annual Inspection · MTSA Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2224545
31 March 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2034708
2 October 2003
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1919446
8 October 2002
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1686542
18 September 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373614
18 August 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1053476
14 August 2000
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1386808
21 October 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 478095
7 October 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1395277
22 January 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1124817
21 December 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 813168
20 November 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1424669
26 November 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1447782
8 October 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1464055
21 October 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1158331
24 September 1996
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1404244
11 October 1995
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414516
9 February 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1424050
22 August 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 874457
6 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 363614
13 December 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438125
18 February 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1393895
6 January 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1160898
20 August 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 516440
9 March 1992
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1008852
4 February 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 657095
10 January 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1268033
24 December 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 960872
19 December 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1269939
22 January 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 931646
29 November 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1237546
8 November 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 537556
25 October 1989
COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1210759
30 November 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1033711
2 August 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 499294
22 April 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 516240
14 January 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 484297
3 December 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1000790
23 October 1987
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1327778
15 December 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1001151
10 January 1986
Credit Drydock
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1300831
18 October 1985
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 994565
19 November 1984
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 477739
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 July 2019
Resolved
Flame screens on the three lube oil tanks and the #02 cargo tank were worn and painted. Renew the four flame screens
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 17 July 2019
Resolution: New flame screens had been installed on the 04 tank vents.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 July 2019
Resolved
Electrical distribution panel was not properly labeled to denote different circuits. Label breakers to indicate the circuit they protect.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 17 July 2019
Resolution: Electrical distribution panel was properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2019
Resolved
Electrical chord powering the potable water pump was worn at plug and multiple places along its length. Repair or replace power chord
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 17 July 2019
Resolution: Electrician satisfactorily repaired cable at plug and in worn spots
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2019
No resolution recorded
At the next drydock, permanently install electrical wiring to provide power outlet for potable water pump. Can be installed in similar manner to the two outlets near the lube oil pumps.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2019
Resolved
Life ring buoy grab line was worn and degraded. Replace line or remove ring buoy.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 25 July 2019
Resolution: Vessel representative provide satisfactory replacement life ring buoy
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 30 October 2013
Resolved
Transfer procedures are vague and do not reflect the transfer operations of above tank that transfer lube oils.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2013
Resolved 7 November 2013
Resolution: Company updated transfer procedures to reflect operation
Deck/Cargo › Cargo Transfer (solid) › General
Issued 30 October 2013
Resolved
Cargo piping and cargo piping gauges have tags on them reflecting last year’s calibration tests and have not been updated to match the calibration certificates on the barge.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2013
Resolved 7 November 2013
Resolution: Barge provided calibration certificates for gauges on barge.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 30 October 2013
Resolved
One meter sticks as overfill device did not work as intended due to water and due to age they had warped and could not freely raise up as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2013
Resolved 7 November 2013
Resolution: overfill device was fixed and is operable.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 30 October 2013
Resolved
Barge Prime mover flexible fuel hoses are not SAE J-1942 as required and are recreational vessel fuel hoses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2013
Resolved 7 November 2013
Resolution: Company provided evidence that hoses were replaced and provided pic providing evidence.
Construction/Loadline › Structures › Deck Plating
Issued 13 November 2012
Resolved
Prove structural integrity of the vessel in way of the wasted tank tops prior to the carriage of cargo. 46 CFR 32.59-1 / NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2012
Resolution: Vessel Proved UT shots of the vessels tank top.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 27 September 2006
Resolved
Re-conduct hydro testing of cargo piping in the presence of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Hydro testing of cargo piping witnessed by CG Marine Inspectors.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 27 September 2006
Resolved
Update Transfer Procedures Diagram.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Confirmed that Transfer Diagram was updated.
Deck/Cargo › Towing › Tackle
Issued 27 September 2006
Resolved
Repair or remove improperly pieced shackle (threaded bolt w/ too low tensile strength).
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Improperly pieced shackle removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 September 2006
Resolved
Remove chopped live wire formerly attached to winch.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 27 September 2006
Resolution: Removed chopped live wire formerly attached to winch.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 27 September 2006
Resolved
Clean insect nests and associated debris out of controller boxes.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 27 September 2006
Resolution: Cleaned insect nests and associated debris out of controller boxes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 September 2006
Resolved
Remove chopped live wire hanging from generator's shore power controller box.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 27 September 2006
Resolution: Removed chopped live wire hanging from generator''s shore power controller box.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 September 2006
Resolved
Investigate and repair source of water in portside light near generator.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Water leak in light found to be caused by water penetrating seal at top of light enclosure. Water removed, leak repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 September 2006
Resolved
Freshen flat black color of navigation light boxes.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Nav light boxes black paint freshened.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 27 September 2006
Resolved
Provide rubber mat in front of controller boxes.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Rubber mat provided in front of controller boxes.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 September 2006
Resolved
Remove paint stowed on top of shack.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 12 October 2006
Resolution: Paint stowed on top of shack removed.
Electrical
Issued 20 November 1998
Resolved
RENEW PORT LUBE OIL PUMP MOTOR CONTROLLER BOX IN GENERATOR ROOM.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Construction/Loadline
Issued 20 November 1998
Resolved
PERMANENTLY REPAIR LEAKS IN DECKHOUSE IN THE VICINITY OVER MOTOR CONTROLLERBOXES.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Deck/Cargo
Issued 20 November 1998
Resolved
INSTALL PYREX SIGHT GLASSES AND GUARDS ON (3) LUBE OIL DECK TANKS.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Construction/Loadline
Issued 20 November 1998
Resolved
PROVIDE PROTECTION (DRIP SHIELD) FOR MOTOR CONTROLLERS IN GENERATOR DECK HOUSE.
Condition: Unknown
Due 20 November 1998
Resolved 7 December 1998
Engineering
Issued 20 November 1998
Resolved
REPAIR FUEL LEAK AT UNION LOCATED ON GENERATOR RETURN FUEL LINE AT DIESEL TANK.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Electrical
Issued 20 November 1998
Resolved
CAP OFF ELECTRICAL CABLE RUNS TO UNUSED THERMOSTAT AT SLOP OIL TANKS.
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Electrical
Issued 20 November 1998
Resolved
PROPERLY CONNECT (SEAL) UNION ON ELECTRICAL CABLE RUN TO FORWARD LIGHT._x001C_
Condition: Unknown
Due 20 November 1998
Resolved 20 November 1998
Deck/Cargo
Issued 26 November 1997
Resolved
PROVE ORIGINAL THICKNESS OF BOTH SLOP OIL TANKS ONBOARD.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 8 October 1997
Resolved
REPAIR ELECTRICAL CABLE CONNECTION AT L/O PUMP # 1.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Engineering
Issued 8 October 1997
Resolved
REPLACE CORRODED FUEL SUPPLY PIPING TO CARGO PUMP, AGAINST THE FWD BULKHEADTO GEN SHACK.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Deck/Cargo
Issued 8 October 1997
Resolved
SUBMIT LETTER TO PA OCMT REQUESTING RE-DESIGNATION OF THE 10,000 GAL DECK TANKS TO SLOP OIL SERVICE.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 24 September 1996
Resolved
NAME NOT DISPLAYED ON BOW SECTION OF BARGE - ON SIDE SHELL OR SIGN AT THE CENTER LINE OF BARGE.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Lifesaving
Issued 24 September 1996
Resolved
HINGES FOR GUAGING PORT COVER ON FORWARD CARGO TANK TRUNK ARE BROKEN.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Deck/Cargo
Issued 24 September 1996
Resolved
GOOSE NECK VENT WITH FLAME SCREEN MISSING FROM STBD SIDE AFT, DECK TANK.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Lifesaving
Issued 24 September 1996
Resolved
"DANGER DO NOT ENTER" NOT PAINTED ON AFTER, DECK, OIL TANKS
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Documentation
Issued 24 September 1996
Resolved
COPY OF CERTIFICATE OF DOCUMENTATION NOT AVAILABLE AT TIME OF INSPECTION.
Condition: Unknown
Due 7 October 1996
Resolved 7 October 1996
Deck/Cargo
Issued 24 September 1996
Resolved
AMEND CARGO TRANSFER PROCEDURES TO REFLECT TRANSFER FROM LUBE OIL DRUMS ON DECK.
Condition: Unknown
Due 24 September 1996
Resolved 24 September 1996
Deck/Cargo
Issued 9 February 1995
Resolved
SECURE FLAME SCREEN TO RING ON NUMBER 1 CARGO TANK GAUGING OPENING.
Condition: Unknown
Due 8 March 1995
Resolved 17 February 1995
Construction/Loadline
Issued 9 February 1995
Resolved
PROPERLY REPAIR APPROX. 4" FRACTURE IN HULL PLATING, PORT SIDE IN WAY OF NUMBER 4 WING VOID, 6" BELOW MAIN DECK.
Condition: Unknown
Due 8 March 1995
Resolved 17 February 1995
Engineering
Issued 9 February 1995
Resolved
REPAINT EMERGENCY REMOTE SHUTDOWN SIGN FOR CARGO PUMP GENERATOR.
Condition: Unknown
Due 8 March 1995
Resolved 17 February 1995
Electrical
Issued 9 February 1995
Resolved
REPLACE SPLICED EXTENSION CORD TO PUMPING LIGHT AND ENCLOSE IN HARD PIPE.
Condition: Unknown
Due 8 March 1995
Resolved 17 February 1995
Engineering
Issued 9 February 1995
Resolved
REPLACE CARGO PUMP ENGINE AND GENERATOR FUEL SUPPLY HOSES WITH HARD PIPING FROM DIESEL TANK.
Condition: Unknown
Due 8 March 1995
Resolved 17 February 1995
Documentation
Issued 13 December 1993
Resolved
PROVIDE UPDATED AND CORRECTED CARGO TRANSFER PROCEDURES.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Engineering
Issued 13 December 1993
Resolved
PROVIDE VENT WITH FLAME SCREEN FOR DIESEL FUEL TANK FOR GENERATOR.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Electrical
Issued 13 December 1993
Resolved
PROVIDE REMOTE SHUTDOWN FOR GENERATOR, OUTSIDE GENERATOR ROOM.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Electrical
Issued 13 December 1993
Resolved
REMOVE OR REPOSITION CONDUIT FOR NAV. LIGHTS.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Deck/Cargo
Issued 13 December 1993
Resolved
REPAIR OR REPLACE ULLAGE COVERS ON CARGO TANK DOMES.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Deck/Cargo
Issued 19 December 1991
Resolved
INSTALL A PERSONNEL GUARD IN WAY OF THE CARGO PUMP EXHAUST PIPE.
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Electrical
Issued 19 December 1991
Resolved
INSTALL A COVER PLATE FOR THE SERVICE GENERATOR DISCONNECT SWITCH._x001C_
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Documentation
Issued 19 December 1991
Resolved
UNTIL SUCH TIME AS THE CERTIFICATE OF FINANCIAL RESPONSIBILITY (OIL POLLUTION) IS ONBOARD, NO CARGO IS PERMITTED TO BE LOADED OR DISCHARGED._x001C_
Condition: Unknown
Due 31 December 1991
Resolved 31 December 1991
Electrical
Issued 19 December 1991
Resolved
REMOVE THE "SO" TYPE HARD-WIRED CABLE AND INSTALL AN APPROVED TYPE CABLE FOR THE DECK LIGHT POWER CORD._x001C_
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Electrical
Issued 19 December 1991
Resolved
INSTALL PERSONNEL GUARDS IN WAY OF THE SERVICE GENERATOR BELT PULLY AND EXHAUST PIPE FOR THE PRIME MOVER._x001C_
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Construction/Loadline
Issued 25 October 1989
Resolved
RE-INSTALL CHAIN ON STBD DECK HATCH COVERING.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Construction/Loadline
Issued 25 October 1989
Resolved
PERMANENTLY FIX AND PAINT VESSEL'S HOMEPORT ON STERN.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Construction/Loadline
Issued 25 October 1989
Resolved
STENCIL PROPER DRAFT MARKINGS ON VESSEL'S SIDE
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Navigation
Issued 25 October 1989
Resolved
PROPERLY INSTALL STANCHION AND YELLOW TOWING LIGHT ON BOW.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Deck/Cargo
Issued 25 October 1989
Resolved
STENCIL MARKINGS ON TANK OPENINGS TO READ "DANGER KEEP OUT" LETTERS OF 3" HIGH.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989
Resolved
PROVE PROPER OPERATION OF GENERATOR.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Deck/Cargo
Issued 25 October 1989
Resolved
GAS FREE AND MAKE AVAILABLE FOR INTERNAL EXAM THE THREE (3) FORWARD LUBE OIL DECK TANKS AND AFT DIRTY OIL DECK. AFTER THE INTERNALEXAM A 5 PSI HYDROTEST SHALL BE WITNESSED BY THE COAST GUARD. IN THE INTERIM THESE TANKS SHALL REMAIN EMPTY.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Deck/Cargo
Issued 25 October 1989
Resolved
PRIOR TO TRANSFERRING CARGO FROM VESSEL TO SHORESIDE FACILITY GIVE 24 HR. ADVANCE NOTICE (MINIMUM) SO THAT A MARINE INSPECTOR MAY WITNESS INTEGRITY OF CARGO PIPING FLANGE AMIDSHIPS CONTACT MARINE INSPECTOR DURING NORMAL WORKING HOURS AT 690-7137.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Construction/Loadline
Issued 25 October 1989
Resolved
RE-INSTALL AND PROPERLY STENCIL WARNING SIGN ON STERN.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Deck/Cargo
Issued 23 October 1987
Resolved
REPAINT WARNING SIGN.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Deck/Cargo
Issued 23 October 1987
Resolved
SECURE STARTING BATTERY FOR CARGO PUMP ENGINE.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Deck/Cargo
Issued 23 October 1987
Resolved
LAG EXHAUST PIPING FOR CARGO PUMP ENGINE.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Electrical
Issued 23 October 1987
Resolved
DRAIN LIGHT FIXTURE IN CARGO PUMP ROOM OF LIQUID AND ENSURE TIGHT SEAL OF GLOBE.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Deck/Cargo
Issued 23 October 1987
Resolved
TEST OR REMOVE ALL NON-METALLIC CARGO HOSES ON BARGE.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Deck/Cargo
Issued 23 October 1987
Resolved
REPAIR LEAK TO SURGE TANK (AIR ELIMANATOR) IN TOP FLANGE.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Deck/Cargo
Issued 23 October 1987
Resolved
REPLACE FOUR MISSING VALVE HANDLES ON FOWARD AND AFTER CARGO TRANSER CROSS-OVER HEADERS(MANIFOLDS).
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 23 October 1987
Resolved
REMOVE ALL FOREIGN AND EXTRANEOUS MATERIAL FROM MAIN DECK AREA.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Navigation
Issued 23 October 1987
Resolved
FAIR BENT STARBOARD RUNNING LIGHT STAND.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Construction/Loadline
Issued 10 January 1986
Resolved
BOTTOM PLATING HOLED IN MANY LOCATIONS, GAUGED WITH ULTRASONIC TESTING EQUIPMENT, AND FOUND TO BE UNACCEPTABLY THIN. ENTIRE BOTTOM REPLACED AS ORIGINAL FROM 1ST PLATE OF SLOPE SHEET IN BOW RAKE TO TRANSOM AT STERN.
Condition: Unknown
Due 10 January 1986
Resolved 10 January 1986