MAURY USCG vessel records Sign in
← All vessels

CAPE JUBY

CAPE JUBY is a 1962 freight ship. The Coast Guard has recorded 68 inspections since 1988, most recently in April 2024, along with 127 deficiencies.

Records from 1988 to 2024. Most recent: inspection, 25 April 2024.

Built
1962
Last inspected
25 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5144485 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
366591000 (licence lapsed)
Maury page id
psix-44326

Inspections, by type

…with no type recorded24
Years with a record 17 calendar years (1988–2024)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12691 - Regulatory (Subpart C or D), Gross Ton
9298 - Dual (D), Gross Ton
12929 - Convention (Subpart B), Gross Ton
8140 - Regulatory (Subpart C or D), Net Ton
5439 - Dual (D), Net Ton
7316 - Convention (Subpart B), Net Ton
12840 - Dead Weight, Ton
21090 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WEBWMMSI 366591000 · expired · compulsorily equipped · granted 5 October 1998, cancelled 6 December 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FELLS POINT Towing Vessel · MISLE 72487 · 2 February 1998 · activity 155655CAPE Towing Vessel · MISLE 92300 · 2 February 1998 · activity 155655

Inspection history · 68

25 April 2024 Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7901385
17 January 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2276025
2 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2125918
25 March 2004 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2031273
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995676
28 May 2003 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1937523
10 February 2003 Drydock Extension
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1742282
5 November 2002 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1701329
9 October 2002 Welding Related Inspections Qualification Testing
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1687157
19 September 2002 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1673393
11 September 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1674229
4 September 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1670288
17 June 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1641363
17 May 2002 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1618707
13 May 2002 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1616078
12 March 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1493143
1 February 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1484260
23 January 2002 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1479818
4 October 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1399720
14 June 2001 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1065624
13 April 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1422046
2 February 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1399537
21 June 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 820116
9 May 2000 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 821685
2 May 2000 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1048544
11 April 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1048644
21 January 2000 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1376028
22 December 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415292
5 October 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 69115
22 September 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 785392
31 July 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 804026
24 February 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2528
5 October 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1461917
21 September 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1426130
2 February 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 155655
24 January 1998 MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430508
23 January 1998 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1421444
7 October 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1446540
21 February 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1091180
19 February 1997 Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1422795
2 March 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1165152
8 December 1994 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1140984
5 October 1994 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1468763
22 September 1993 Initial Construction-Excluding Oversight · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1139415
9 September 1993 Inclining Experiment
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 832442
19 November 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 832369
19 November 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 943323
19 November 1992 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1142687
8 April 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 453004
3 January 1992 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1256866
10 December 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 516810
14 November 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1312720
14 November 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1312722
30 August 1991 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 942648
28 August 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 345701
28 August 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1246838
19 April 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 486132
1 April 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 497005
19 February 1991 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 535003
25 January 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1224952
19 January 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 933339
16 January 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 473980
8 January 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 903093
25 August 1990 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 900742
3 November 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 891830
3 November 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1034259
26 October 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1206924
20 July 1988 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1018447

Deficiency record · 127

Electrical › Electric Generation Source (emergency)
Issued 19 September 2002 Resolved
Prove proper operation of hydraulic starting system on EDG. LEGACY COMPONENT DESC: Power Requirement
Condition: Improper/Lack of Maintenance
Due 3 December 2002
Resolved 6 November 2002
Lifesaving › Lifeboat
Issued 23 January 2002 Resolved
Before placing vessel in operation, conduct port and stbd life boat weight test.
Due 30 September 2002
Resolved 20 May 2002
Engineering
Issued 23 January 2002 Resolved
PROPERLY ENERGIZE THE FOLLOWING EQUIPMENT TO CONDUCT SAFETY REQUIREMENTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR: BOILERS (2), GENERATORS (2), MAIN ENGINE (1), EVAPORATORS (2).
Due 30 September 2002
Resolved 17 May 2002
Lifesaving
Issued 23 January 2002 Resolved
BEFORE PLACING VESSEL IN OPERATIONAL STATUS, PROVIDE ADEQUATE CREW IN ORDER TO CONDUCT MAN OVERBOARD, FIRE FIGHTING AND ABANDON SHIP DRILLS WITH FULL CREW.
Due 30 September 2002
Resolved 20 May 2002
Lifesaving › Lifeboat
Issued 18 January 2002 Resolved
Lifeboat #1 prop contacts steering nozzle. Adjust nozzle and check/renew cutless bearing as needed. LEGACY COMPONENT DESC: Propeller
Due 30 January 2002
Resolved 29 January 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 18 January 2002 Resolved
Renew bell and flame screen serving vent #1 stbd. LEGACY COMPONENT DESC: Vent Pipe
Due 30 January 2002
Resolved 29 January 2002
Unknown
Issued 13 April 2001 Resolved
Prove proper operation of potable water pressure vessel relief valve.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Lifesaving
Issued 13 April 2001 Resolved
Conduct man overboard, fire fighting and abandon ship drills upon activation.
Condition: Unknown
Due 31 December 2002
Resolved 20 May 2002
Lifesaving
Issued 13 April 2001 Resolved
SHOW OPERATIONAL TESTS OF BOTH LIFE BOATS.
Condition: Unknown
Due 31 December 2002
Resolved 20 May 2002
Engineering
Issued 13 April 2001 Resolved
CROP AND RENEW VOID VENTS, FUEL, LUBE AND OIL TANK VENTS, ETC. AS NEEDED THROUGHOUT VESSEL.
Condition: Unknown
Due 30 April 2001
Resolved 23 January 2002
Electrical
Issued 21 January 2000 Resolved
Prove proper operation of Emergency Generator hydro start system to satisfaction of attending class surveyor.
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Lifesaving
Issued 21 January 2000 Resolved
Provide permanent embarkation ladders for prt and stbd lifeboats / liferafts IAW 46 CFR 199.110, to satisfaction of attending USCG inspector.
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Engineering
Issued 22 September 1999 Resolved
Patch refractory on the stbd main propulsion boiler front wall generating section, approx. 10 ft up from the floor. (4" x 12" section missing)
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Electrical
Issued 21 September 1998 Resolved
REWIRE AND INSTALL PROPER COVER FOR SUPERHEATER TEMPERATURE SENSOR IN WAY OF # 2 PROPULSION BOILER.
Condition: Unknown
Due 21 September 1998
Resolved 21 September 1998
Lifesaving
Issued 21 September 1998 Resolved
CHANGE LIFERAFT LAUNCHING ARRANGEMENT SO RAFTS DO NOT NEED TO BE LIFTED MORE THAN 1 FOOT FROM THE DECK IAW 46 CFR 199.130(a)(7)(ii).
Condition: Unknown
Due 21 September 1998
Resolved 21 September 1998
Lifesaving
Issued 21 September 1998 Resolved
PROVIDE LIFTRAFTS WITH AN AGGREATE CAPACITY ON EACH SIDE SUFFICENT TO ACCOMODATE THE TOTAL NUMBER OF PERSONS ON BOARD IAW 46 CFR 199.261(b)(2)(ii).
Condition: Unknown
Due 21 September 1998
Resolved 21 September 1998
Unknown
Issued 21 September 1998 Resolved
PROVIDE MISSING MANUFACTURES DATA INFORMATION IN WAY OF CONTROL AIR RECIEVER IAW 46 CFR 54.10-20
Condition: Unknown
Due 21 September 1998
Resolved 21 September 1998
Lifesaving
Issued 24 January 1998 Resolved
PRIOR TO ACTIVATION VSL MUST COMPLETE SATISFACTORY FIRE AND ABANDON SHIP DRILLS.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Accommodation/Occupational Safety
Issued 24 January 1998 Resolved
PRIOR TO ACTIVATION PROVIDE ALL NECESSARY FIRST AID EQUIPMENT FOR THE HOSPITAL SPACE.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Documentation
Issued 24 January 1998 Resolved
PRIOR TO ACTIVATION VSL MUST PROVIDE ALL FORMS, NOTICES, & PUBLICATIONS AS PER CG840A BOOK ITEMS J1-J11.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Electrical
Issued 24 January 1998 Resolved
In 120v dist. panel IWO stbd boiler, replace 70A breaker in L46A/50A slot with breaker of proper amperage.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Electrical
Issued 24 January 1998 Resolved
In 120v dist. panel, IWO stbd boiler, remove (and blank hole) or mark as spare, unused 30A breaker
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Electrical
Issued 24 January 1998 Resolved
In Distribution Board A, properly mark breaker currently (Out of Service) tagged; Cargo Oil Hot Water Circ. Pump #1
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Electrical
Issued 24 January 1998 Resolved
Install non-conductive mat in front of Distribution Board A
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Electrical
Issued 24 January 1998 Resolved
Prove proper operation of ground fault detectors and lack of grounds while operating on ship's power to satisfaction of attending Marine Inspector.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Engineering
Issued 24 January 1998 Resolved
Set and seal propulsion boiler safety valves with attending CG Marine Inspector
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Unknown
Issued 24 January 1998 Resolved
Demonstrate proper operation of stores refrigeration plant to satisfaction of attending CG Marine Inspector
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Electrical
Issued 24 January 1998 Resolved
Make Emergency Batteries available for Inspection.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Documentation
Issued 24 January 1998 Resolved
Make Engineering staff licenses/documents available for examination
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Unknown
Issued 24 January 1998 Resolved
Prove proper operation of Oily Water Separator to satisfaction of attendingCG Marine Inspector.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Lifesaving
Issued 24 January 1998 Resolved
Prior to activation vessel must provide all liferafts and service certi- ficates. Because new Lifeboat installation you must prove to CG that you are capable to launch on either side of the ship and of such aggregate capacity as will accomodate the total# of persons on board.SOLAS/III/REG26.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Lifesaving
Issued 24 January 1998 Resolved
PRIOR TO ACTIVATION PROVIDE ALL REQUIRED LINE THROWING APPARATUS.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Lifesaving
Issued 24 January 1998 Resolved
PRIOR TO ACTIVATION VSL MUST CONDUCT LIFEBOAT WEIGHT TEST FOR #1 & #2 LIFEBOAT.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Lifesaving
Issued 24 January 1998 Resolved
PRIOR TO ACTIVATION VSL MUST TEST THE GENERAL ALARM.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Navigation
Issued 24 January 1998 Resolved
PRIOR TO ACTIVATION ALL YOUR NAVIGATION EQUIPMENT MUST BE TESTED.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Electrical
Issued 24 January 1998 Resolved
Properly label spare breaker on main switchboard between breakers P6 & P20
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Unknown
Issued 24 January 1998 Resolved
Provide Shrader valve or hydrostatically test potable water head tank to establish MAWP/stamp or affix label plate with CG assigned pressure vessel serial numbers. Test pressure relief valve.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Fire Fighting
Issued 24 January 1998 Resolved
Properly mark fire room sand box so contents are apparent.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Electrical
Issued 24 January 1998 Resolved
Remove/repair light over bench grinder
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Electrical
Issued 7 October 1997 Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTING.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Lifesaving
Issued 7 October 1997 Resolved
PROVE PROPER OPERATION OF RELEASING GEAR FOR L/B NO.2 AND OPERATE IN THE WATER.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Construction/Loadline
Issued 7 October 1997 Resolved
RENEW WASTED DECK PLATING IN WAY OF CARGO WINCH DECK OPERATING STATION 7/8.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Lifesaving
Issued 19 February 1997 Resolved
AT THE NEXT ACTIVATION, AND WITH A FULL CREW, CONDUCT A SATISFACTORY FIRE AND LIFEBOAT DRILL.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Engineering
Issued 19 February 1997 Resolved
REPLACE MISSING WATER LEVEL INDICATOR LIGHTS AND MIRRORS FOR BOTH BOILERS.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Construction/Loadline
Issued 19 February 1997 Resolved
RENEW THE WASTED LONGITUDINAL FRAMES IN THE SUMP OF THE SHAFT ALLEY BILGE WELL.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Construction/Loadline
Issued 19 February 1997 Resolved
CROP AND RENEW WASTED FONDATIONS FOR THE FOLLOWING PUMPS: MAIN FIRE PUMP, FIRE AND TANK CLEANING PUMP.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Documentation
Issued 19 February 1997 Resolved
AT THE NEXT ACTIVATION, PROVIDE A CURRENT FCC CERTIFICATE.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Construction/Loadline
Issued 19 February 1997 Resolved
REPAIR ALL WEATHERDECK DOORS WHICH DO NOT OPERATE PROPERLY AND REPLACE MISSING GLASS IN DOORS WHERE GLASS IS MISSING WITH PROPER GLASS.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Navigation
Issued 19 February 1997 Resolved
AT THE NEXT ACTIVATION, ALL BRIDGE NAVIGATION EQUIPMENT IS TO BE TESTED.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Construction/Loadline
Issued 19 February 1997 Resolved
CROP AND RENEW TO ORIGINAL, WASTED AREAS OF LOWER BULKHEAD BETWEEN CARGO HOLD #5 & #6.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Lifesaving
Issued 19 February 1997 Resolved
AT THE NEXT ACTIVATION, PROVIDE ALL LIFEBOAT EQUIPMENT FOR EXAMINATION.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Lifesaving
Issued 19 February 1997 Resolved
AT THE NEXT ACTIVATION, PROVIDE THE FOLLOWING LIFESAVING EQUIPMENT FOR EXAMINATION: LIFE PRESERVERS, RING BUOYS, EXPOSURE SUITS.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Lifesaving
Issued 19 February 1997 Resolved
AT THE NEXT ACTIVATION, PROVIDE ALL HOSPITAL EQUIPMENT FOR EXAMINATION.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Fire Fighting
Issued 5 October 1994 Resolved
PROVIDE A PROPER STOWAGE RACK FOR THE SPARE HIGH PRESSURE CO2 AND HALON CYLINDERS PRESENTLY STOWED THROUGHOUT THE VESSEL.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Engineering
Issued 5 October 1994 Resolved
REPLACE THE DIESEL OIL TRANSFER PUMP MOTOR.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Fire Fighting
Issued 5 October 1994 Resolved
CLOSE THE OPEN RAT HOLE IN THE A-60 BHD FOR THE SHAFT ALLEY PAINT LOCKER ORPERMANENTLY REDESIGNATE THIS SPACE.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Electrical
Issued 5 October 1994 Resolved
PROVIDE NON-CONDUCTIVE MATTING OR GRATING AT ALL SWITCHBOARDS.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Electrical
Issued 5 October 1994 Resolved
RENEW THE WIRING TO THE PORT AFT DAVIT LIMIT SWITCH.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Fire Fighting
Issued 22 September 1993 Resolved
PROVIDE AN UPDATED FIRE CONTROL PLAN FOR APPROVAL.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Construction/Loadline
Issued 19 November 1992 Resolved
REPAIR, HOSE TEST AND PROVE OPERATION OF ALL CARGO HATCH COVERS AND WATERTIGHT DOORS.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Fire Fighting
Issued 19 November 1992 Resolved
REPAIR AND PROVE OPERATION OF SMOKE DETECTION SYSTEM PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Engineering
Issued 19 November 1992 Resolved
CLEAN, GAS FREE AND MAKE AVAILABLE FOR INTERNAL EXAMINATION DOUBLE BOTTOM FUEL TANKS IN WAY OF NR 5 CARGO HOLD, MACHINERY SPACE AND LUBE OIL COFFERDAM TO COMPLETE REQUIREMENTS FOR CREDIT DRYDOCK EXAMINATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
INSTALLATION OF LIFEBOAT WEIGHT TEST WATERLINE PLATES WERE NOT CONFIRMED BYCOAST GUARD. REMOVE PLATES OR PROVE LOCATION OF INSTALLED PLATES CORRESPONDS TO REQUIRED WEIGHT (IN GALLONS OF WATER).
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
RENEW ALL DATED LIFEBOAT EQUIPMENT PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Documentation
Issued 19 November 1992 Resolved
PROVIDE PLANS AND SPECIFICATIONS FOR RECENTLY INSTALLED POTABLE WATER EVAPORATORS.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
MAKE AVAILABLE FOR INSPECTION ALL LIFEBOAT EQUIPMENT PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
CONDUCT EMERGENCY FIRE AND BOAT DRILLS WITH ALL HANDS IN PRESENCE OF COAST GUARD MARINE INSPECTOR PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
PLACE ALL FIRE FIGHTING AND LIFESAVING EQUIPMENT ON STATION PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
RENEW ALL DATED PYROTECHNICS FOR LINE THROWING APPARATUS PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
MAKE LINE THROWING APPARATUS WITH REQUIRED EQUIPMENT AVAILABLE FOR INSPECTION PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
RENEW ALL DATED DISTRESS FLARES PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
MAKE AVAILABLE FOR INSPECTION AND PROVE OPERATION OF VESSEL'S EPIRB PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Documentation
Issued 19 November 1992 Resolved
PROVIDE VALID LICENSES FOR SHIP'S OFFICERS PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Documentation
Issued 19 November 1992 Resolved
PROVIDE CURRENT AND CORRECTED CHARTS AND PUBLICATIONS FOR THE AREA OF OPERATION PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Unknown
Issued 19 November 1992 Resolved
RENEW ALL DATED HOSPITAL SUPPLIES AND MAKE HOSPITAL AVAILABLE FOR_x001C_ INSPECTION PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
RENEW ALL DATED EQUIPMENT FOR FIREMANS OUTFITS AND MAKE AVAILABLE FOR INSPECTION PRIOR TO ACTIVATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
CLEAN, STOW ALL GEAR AND MAKE AVAILABLE FOR INSPECTION ALL COMPARTMENTS. ENSURE ALL REQUIRED MARKINGS AND NOTICES POSTED FOLLOWING PAINTING.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Construction/Loadline
Issued 19 November 1992 Resolved
RENEW AND MAKE AVAILABLE FOR INSPECTION 40 INCH MAIN CONDENSER OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Engineering
Issued 19 November 1992 Resolved
REPLACE OR PROVE PROPER REPAIRS TO CONTAMINATED FEED WATER EVAPORATOR PRIORTO PLACING EVAP. IN OPERATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Fire Fighting
Issued 19 November 1992 Resolved
PROVIDE COPY OF CURRENT FIRE FIGHTING EQUIPMENT SERVICING REPORT.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
PROVIDE COPY OF CURRENT LIFERAFT SERVICING CERTIFICATES.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Lifesaving
Issued 19 November 1992 Resolved
PROVIDE SUFFICIENT LIFERAFT CAPACITY TO ACCOMODATE THE TOTAL NUMBER OF PERSONS ONBOARD AS REQUIRED BY SOLAS CH III, REG 26.3.1 PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Accommodation/Occupational Safety
Issued 19 November 1992 Resolved
REPLACE MSD SYSTEM WITH APPROVED SYSTEM WITH CAPICITY CERTIFIED FOR NUMBER OF PERSONS CARRIED AND PROVE PROPER OPERATION.
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Fire Fighting
Issued 14 November 1991 Resolved
UNTIL PROOF IS PROVIDED, TO THE COGNIZANT OCMI, THAT THE CARGO HOLD SMOKE DETECTION SYS. IS FULLY OPERATIONAL, THERE MUST BE A ROVING PATROL ESTAB. TO MONITOR THE CARGO HOLDS. THE PATROL MUST MAKE ROUNDS AT INTERVALS NOT TO EXCEED 1 HR. AND EACH ROUND MUST BE LOGGED IN THE VESSEL'S LOG.
Condition: Unknown
Due 14 November 1991
Resolved 14 November 1991
Fire Fighting
Issued 30 August 1991 Resolved
PROVE PROPER OPERATION OF CARGO HOLD SMOKE DETECTION SYSTEM.
Condition: Unknown
Due 30 August 1991
Resolved 30 August 1991
Deck/Cargo
Issued 19 January 1991 Resolved
INSTALL WOODEN SHEET PLYWOOD OVER GRAIN FEEDER HOLERS ON THE LOWER BETWEEN DECKS IN CARGO HOLDS NO. 2,3,5 AND 6. ENSURE SHEETS ARE SECURED TO THE DECKWITH ADHESIVE._x001C_ R.G. SORRELL_x001C_
Condition: Unknown
Due 19 January 1991
Resolved 19 January 1991
Electrical
Issued 19 January 1991 Resolved
ENSURE ALL NON EXPLOSIVE PROOF FITTINGS/CIRCUITS IN CARGO HOLDS NO. 2,3,5 AND 6 ARE OPENED AND TAGGED SECURED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 January 1991
Resolved 19 January 1991
Construction/Loadline
Issued 25 August 1990 Resolved
MAKE PRMINANT REPAIRS IN WAY OF TEMPORARY REPAIRS TO THE TOP OF THE DISTILLED WATER TANK LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 25 August 1990
Resolved 25 August 1990
Construction/Loadline
Issued 25 August 1990 Resolved
MAKE PERMINANT REPAIRS TO THE REMOTE WATERTIGHT DOOR OPEN / CLOSE INDICATORFOR THE SHAFT ALLEY DOOR LOCATED IN THE STAIR TOWER.
Condition: Unknown
Due 25 August 1990
Resolved 25 August 1990
Deck/Cargo
Issued 20 July 1988 Resolved
RENEW PORT ANCHOR WINDLASS SHAFT DUE TO EXCESSIVE WEAR IN GEAR COUPLING.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 20 July 1988 Resolved
OVERHAUL SPEED GOVERNORS TO #1 AND #2 SSTGS AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 20 July 1988 Resolved
REPAIR AND PROVE OPERATIONAL THE VIBRATACHOMETERS TO THE #1 AND #2 SSTGS.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Engineering
Issued 20 July 1988 Resolved
REPAIR AND PROVE OPERATIONAL THE MAIN THROTTLE LOW OIL PRESSURE TRIP SYSTEM
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Engineering
Issued 20 July 1988 Resolved
REPAIR OR RENEW COMPRESSED AIR CUT OUT VALVE TO MAIN DECK AND STOP CHECK VALVE IN CROSSOVER LINE BETWEEN S/S AIR RECEIVER & CONTROL AIR RECEIVER AFT.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Deck/Cargo
Issued 20 July 1988 Resolved
REPAIR OR RENEW VALVES TO TANK HEATING COILS AS PER ITEM 51, MARAD REPAIR LIST.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Engineering
Issued 20 July 1988 Resolved
MAKE THE A/C PNEUMATIC CONTROL AIR RECEIVER AVAILABLE FOR INTERNAL INSPECTION OR HYDROSTATIC TEST AND PROVE OPERAAATION OF RELIEF VALVE AND ASSOCIATED AIR COMPRESSOR.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Documentation
Issued 20 July 1988 Resolved
PROVIDE TRIM & STABILITY BOOK AND STABILITY LETTER FOR USCG INSPECTION.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Documentation
Issued 20 July 1988 Resolved
PROVIDE REWRITE OF FUEL OIL TRANSFER PROCEDURES FOR USCG INSPECTION.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Engineering
Issued 20 July 1988 Resolved
PROVIDE AND DEMONSTRATE PROPER OPRATION OF FUEL OIL TRANSFER EMERGENCY SHUTDOWN.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Engineering
Issued 20 July 1988 Resolved
DEMONSTRATE PROPER OPERATION OF ALL BILGE WELL SUCTIONS AND EDUCTORS.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Deck/Cargo
Issued 20 July 1988 Resolved
REPAIR ALL DAMAGED GOOSENECK VENTS WHERE WASTED AND PROVIDE MEANS OF PREVENTING WATER ENTRY INTO ALL VENT PIPES ON WEATHER DECKS.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988 Resolved
REMOVE ALL GASKETS FROM ALL TONNAGE OPENINGS.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 20 July 1988 Resolved
REPAIR AND MAKE WATERTIGHT ALL CARGO GEAR MOTOR CONTROL BOXES ON ALL CARGO GEAR MOTOR HOUSES.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988 Resolved
REPAIR HOLES IN VENT TRUNK BULKHEAD MOTOR HOUSE NO. 3.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988 Resolved
PROPERLY REWELD BULWARK STIFFENERS WHERE BROKEN AWAY ON MAIN DECK P/S & CROP & RENEW BY INSERT WASTED AREA OF BRACKET STBD OF NO. 5 MTR HOUSE.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Deck/Cargo
Issued 20 July 1988 Resolved
REPAIR ALL DAMAGED/WASTED GUARDS, BRAKE BANDS, & FOUNDATIONS TO ALL CARGO RUNNING GEAR ON ALL MOTOR HOUSES.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Deck/Cargo
Issued 20 July 1988 Resolved
REPAIR WASTED STANCHION SUPPORTS TO MAIN DECK OVERHANG NO. 2 MTR HOUSE.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988 Resolved
REPAIR WELD CRACK ON MAIN HOUSE IN WAY OF PORT FUEL OIL STATION MAIN DECK.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988 Resolved
REPAIR HOLE IN BULKHEAD WEAR DOOR ON 01 DECK PORT SIDE MAIN HOUSE.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988 Resolved
RENEW DECK OVERHANG SUPPORT IN WAY OF SHACKLE ON AFT DECK.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988 Resolved
PROPERLY REPAIR TEAR IN BOAT DAVIT DECK NEAR BULKHEAD PORT SIDE...
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988 Resolved
REPAIR ALL DAMAGED/WASTED CARGO GEAR GREASE LINES AND FOUNDATIONS ON ALL CARGO GEAR MTR HOUSES.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Accommodation/Occupational Safety
Issued 20 July 1988 Resolved
MAKE SANITARY SYSTEM OPERABLE.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Unknown
Issued 20 July 1988 Resolved
REMOVE AND RENEW DISTILLED WATER SUPPLY PIPING TO FOREPEAK WHERE WASTED.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Accommodation/Occupational Safety
Issued 20 July 1988 Resolved
MAKE VESSELS AIR CONDITIONING SYSTEM OPERABLE; REPAIR COILS AS NECESSARY. (SEE MARAD REPAIR LIST)
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Accommodation/Occupational Safety
Issued 20 July 1988 Resolved
REPAIR ALL TANK VENTS AS PER MARAD REPAIR LIST. ENSURE FLAME SCREENS ARE INSTALLED TO ALL FUEL OIL & LUBE OIL TANK VENTS.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Unknown
Issued 20 July 1988 Resolved
REMOVE AND RENEW FEEDWATER PIPING FROM PORT DISTILLED WATER TANK WHERE WASTED.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Unknown
Issued 20 July 1988 Resolved
DISCONNECT FUEL OIL OVERBOARD PIPING FROM FUEL OIL TRANSFER SYSTEM RELIEF LINE.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Accommodation/Occupational Safety
Issued 20 July 1988 Resolved
REMOVE AND REPLACE SANITARY WATER PRESSURE TANK WITH APPROVED ASME CODE PRESSURE VESSEL. PROVIDE CERTIFICATION PAPERS, HYDROSTATICALLY TEST IAW 46 CFR 54.10-10 AND PROVE OPERATION OF INSTALLED RELIEF VALVE.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Deck/Cargo
Issued 20 July 1988 Resolved
PROVE SATISFACTORY OPERATION OF BILGE SYSTEM FROM ALL BILGE WELLS WITH BOTH BILGE PUMPS.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Engineering
Issued 20 July 1988 Resolved
PROVE SATISFACTORY OPERATION OF RELIEF VALVE ON COMBUSTION CONTROL AIR RECEIVER.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Accommodation/Occupational Safety
Issued 20 July 1988 Resolved
PROVE SATISFACTORY OPERATION OF INSTALLED MSD AND PROVIDE MANUFACTURER'S OPERATING INSTRUCTIONS.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Accommodation/Occupational Safety
Issued 20 July 1988 Resolved
REPAIR ER VENT FAN MOTOR NUMBER 45.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Engineering
Issued 20 July 1988 Resolved
RENEW MAIN CIRCULATOR PUMP MOTOR CONTROLLER SWITCH.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Accommodation/Occupational Safety
Issued 20 July 1988 Resolved
REPLACE SALT WATER SERVICE PUMP DISCHARGE DUPLEX STRAINER.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 20 July 1988 Resolved
RENEW 600 VOLT, 50 AMP CIRCUIT BREAKERS TO MAIN DECK STBD LIGHTING LOAD CENTER, AND FOR HOLD #3 LIGHTING LOAD CENTER.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 20 July 1988 Resolved
RENEW TIMING RELAY FOR PORT BOILER FORCED DRAFT FAN MOTOR.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988

Ownership record