Records from 1996 to 1999. Most recent: inspection, 30 April 1999.
Electrical
Issued 2 March 1999
Resolved
PROVIDE CLASS REPORT ADDRESSING NO. 2 GENERATOR FAILURE AND PROPOSAL FOR REPAIRS.
Condition: Unknown
Due 19 March 1999
Resolved 15 April 1999
Lifesaving
Issued 2 March 1999
Resolved
PROVIDE BASIC VSL FAMILIARIZATION FOR CREW AND COMPANY WRITTEN INSTRUCTIONSTO MASTER ENSURING VSL FAMILIARIZATION IS TAKING PLACE.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Lifesaving
Issued 2 March 1999
Resolved
Replace port & stbd bridge wing life buoys with SOLAS approved 4kg life buoys.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Lifesaving
Issued 2 March 1999
Resolved
Replace line for life ring buoy on O3 deck, stbd side.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Accommodation/Occupational Safety
Issued 2 March 1999
Resolved
Provide procedures/crew instructions for sanitary tank discharge operationsand a method for securing overboard valve.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 2 March 1999
Resolved
Make SOLAS Training Manual ship specific.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Documentation
Issued 2 March 1999
Resolved
PROVIDE OIL TRANSFER PROCEDURES IAW 33CFR155.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Lifesaving
Issued 2 March 1999
Resolved
Provide quick release for the rescue boat.
Condition: Unknown
Due 19 March 1999
Resolved 15 April 1999
Documentation
Issued 2 March 1999
Resolved
Provide Flag State issued licenses for the 2nd and 3rd Assistant Engineers.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Lifesaving
Issued 2 March 1999
Resolved
Replace smoke/light float for stbd life ring buoy.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 2 March 1999
Resolved
IMMEDIATELY BEGIN LOGGING GARBAGE/REFUSE DISPOSAL PRACTICES.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Lifesaving
Issued 2 March 1999
Resolved
Provide basic safety training for the crew; personal survival techniques, firefighting, first aid, etc.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Lifesaving
Issued 8 March 1997
Resolved
PFD's do not have retroreflective tape as required by SOLAS. Apply 200 cm's of retroreflective tape to both sides of PFD's
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Lifesaving
Issued 8 March 1997
Resolved
PFD's do not have waterlights as required by SOLAS, provide approved waterlights for all PFD's.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Electrical
Issued 3 March 1997
Resolved
EMERGENCY GENERATOR AND EXHAUST FAN FOR SPACE HAVE NO GUARDS OVER MOVING PARTS. PROVIDE GUARDS FOR FAN AND GENERATOR COUPLING.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Deck/Cargo
Issued 3 March 1997
Resolved
NUMBER 4 CARGO TANK VENT IS HOLED ON THE PORTSIDE. MAKE PERMANENT REPAIRS TO VENT.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
WATERTIGHT DOOR LOCATED CENTERLINE AFT NEAR GALLEY IS INOPERATIVE. MAKE PROPER REPAIRS TO MAKE WATERTIGHT DOOR OPERATIONAL.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Accommodation/Occupational Safety
Issued 3 March 1997
Resolved
COMMODES WERE NOT PROPERLY FUNCTIONING. MAKE ALL INSTALLED COMMODES FUNCTIONAL.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
HOLE WITH CEMENT PATCH VICINITY OF GALLEY DRAIN ON PORTSIDE HULL. MAKE PERMANENT REPAIRS TO HULL AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
HOLE WITH CEMENT PATCH EXTENDING FULL LENGHT OF WASHROOM ON STARBOARD SIDE.MAKE PERMANENT REPAIR TO HULL AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Construction/Loadline
Issued 3 March 1997
Resolved
HATCH TO AFTER STEERING SPACE IS NOT WATERTIGHT. MAKE PROPER REPAIRS TO WATERTIGHT HATCH AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Lifesaving
Issued 3 March 1997
Resolved
RING BUOY LOCATED ON PORTSIDE AFT OF CARGO HATCH IS BADLY WASTED. REPLACE WITH NEW RING BUOY.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Fire Fighting
Issued 3 March 1997
Resolved
SEVERAL FIRE FIGHTING HOSES WERE USED FOR FRESHWATER SUPPLY. PROVIDE SEPERATE HOSES FOR FRESHWATER ONLY AND MAINTAIN FIRE FIGHTING HOSES ON STATION.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Electrical
Issued 3 March 1997
Resolved
EMERGHENCY BATTERY STORAGE LOCKER WIRING AND FIXTURES WERE NONE EXPLOSIVE PROOF. BATTERY CHARGER WORKING IMPROPERLY. INSTALL APPROPRIATE WIRING CONNECTIONS, FIXTURES AND PROVIDE CLASS REPORT OF OVERALL EMERGENCY BATTERYSYSTEM.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Documentation
Issued 3 March 1997
Resolved
SURVEY REPORT OF LAST DRYDOCK BY CLASS WAS NOT AVAILABLE. PROVIDE COPY OF SURVEY TO U.S. COAST GUARD MARINE SAFETY OFFICE, JACKSONVILLE_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Fire Fighting
Issued 3 March 1997
Resolved
SEVERAL FIRE HOSES WERE HOLED AND HAD BAD FITTINGS. RENEW HOSES AND FITTINGS AS NECESSARY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Fire Fighting
Issued 3 March 1997
Resolved
FIRE STATION NOZZELS WERE OF SOLID STREAM TYPE. REPLACE NOZZELS WITH SOLASAPPROVED DUAL PURPOSE NOZZELS.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Documentation
Issued 6 February 1997
Resolved
PROVIDE EVIDENCE OF VALID ORIGINAL CLASS/FLAG VESSEL DOCUMENTS._x001C_ PRIOR TO LOADING CARGO OR DEPARTING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Unknown
Issued 6 February 1997
Resolved
PROVIDE CLASS/FLAG REPORT ON SATISFACTORY COMPLETION OF USCG REQUIREMENTS _x001C_DATED 27 OCT 96._x001C_ PRIOR TO LOADING CARGO OR DEPARTING._x001C_ _x001C_
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Construction/Loadline
Issued 6 February 1997
Resolved
VESSEL HAS SEVERAL HOLES ON PORT SIDE FOREPEAK SIDESHELL PLAING, ALSO SEVERE WASTAGE ON PORTSIDE FOREPEAK FRAMES._x001C_ MUST REPAIR/REPLACE PRIOR TO DEPARTURE AS PER ICLL 66, REG 1.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Engineering
Issued 6 February 1997
Resolved
REPLACE 7 WASTED FUEL VENT PIPES ON MAIN DECK BY SUPERSTRUCTURE, AS PER ICLL 66, REG 20, PRIOR TO DEPARTURE.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Construction/Loadline
Issued 6 February 1997
Resolved
#2 HATCHCOVER HAS A FRACTURE ON THE AFT CENTER PART ON THE KNIFE EDGE, AND IS MISSING A PLATE ON PORT AFT KNIFE EDGE, MUST REPAIR/REPLACE PRIOR TO DEPARTURE AS PER ICLL 66 REG 14.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Construction/Loadline
Issued 6 February 1997
Resolved
REPAIR FRACTURED FRAME ON MAIN DECK STARBOARD SIDE FORWARD OF WBTK 1, AS PER ICLL 66, REG 25.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Deck/Cargo
Issued 27 October 1996
Resolved
55 GAL DRUM OF WASTE OIL IN ENGINE ROOM MUST BE IMMEDAITELY REMOVED.
Condition: Unknown
Due 27 October 1996
Resolved 29 October 1996
Electrical
Issued 27 October 1996
Resolved
REPAIR NO. 3 GENERATOR.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Documentation
Issued 27 October 1996
Resolved
PROVIDE RADIO CERT.
Condition: Unknown
Due 20 February 1997
Resolved 20 February 1997
Lifesaving
Issued 27 October 1996
Resolved
CONDUCT FIRE AND BOAT DRILL TO THE SATISFACTION OF USCG.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Documentation
Issued 27 October 1996
Resolved
PROVIDE ACCEPTANCE LETTER FOR OFFICERS LICENSES.
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Documentation
Issued 27 October 1996
Resolved
PROVIDE MED CERTS FOR CREW.
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Documentation
Issued 27 October 1996
Resolved
PROVIDE SAFETY EQUIP CERT.
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Engineering
Issued 27 October 1996
Resolved
REASSEMBLE FUEL STRAINER
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Documentation
Issued 27 October 1996
Resolved
PROVIDE OIL RECORD BOOK PRIOR TO DEPARTURE. ON DF CHECK ENTRY DATE FOR POSSIBLE VIOLATION.
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Documentation
Issued 27 October 1996
Resolved
PROVIDE AN UPDATED SOLAS MANUAL FOR THE VESSEL POLIANNI DUE, NOT A GENERIC MANUAL...
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Deck/Cargo
Issued 27 October 1996
Resolved
CONNECT THE AIR START LINE TO THE BOTTLE.
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Navigation
Issued 18 July 1996
Resolved
NAVIAGATIONAL CHARTS B.A. #3382 OR NOAA CHARTS #11361, #11364 & 11368 NOT ON BOARD.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Navigation
Issued 18 July 1996
Resolved
SHIP DOES NOT HAVE MANEUVERING INFORMATION DISPLAYED ON THE WHEELHOUSE._x001C_ (33CFR 164.35(g)). CORRECT PRIOR TO NEXT U.S. PORT AFTER FOREIGN VOYAGE/18AUG96.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Accommodation/Occupational Safety
Issued 18 July 1996
Resolved
INSTALL AND PROVE PROPER OPERATION OF APPROVED MARINE SANITATION DEVICE. (33CFR 159.7) CORRECT PRIOR TO DEPARTURE FROM NEW ORLEANS/19JUL96
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Navigation
Issued 18 July 1996
Resolved
NO STEERING GEAR CHANGE OVER DESPLAYED IN WHEEL HOUSE. (33CFR 164.35(k)). CORRECT PRIOR TO NEXT U.S. PORT AFTER FOREIGN VOYAGE/18AUG96.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Engineering
Issued 18 July 1996
Resolved
PROVIDE PERSONNEL SAFETY GUARDS ON ROTATING MACHINERY. (SOLAS 60II27). CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Electrical
Issued 18 July 1996
Resolved
REPAIR/REMOVE EXPOSED ELECTRICAL FIXTURE THROUGHOUT MACHINERY SPACE. (SOLAS60 II 27) CORRECT PRIOR TO DEPARTURE/19JUL96.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Fire Fighting
Issued 18 July 1996
Resolved
PROVIDE FIREHOSES & WRENCHES AS REQ. BY SEC/FIR CONTROL PLAN (SOLAS 60 III52). CORRECT PRIOR TO DEPARTURE FROM NEW ORLEANS.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Lifesaving
Issued 18 July 1996
Resolved
REPAIR RING BUOY LIGHTS ON ALL BUOYS (SOLAS 60 III21). CORRECT PRIOR TO DEPARTURE FROM PORT OF NEW ORLEANS.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Engineering
Issued 18 July 1996
Resolved
REPAIR LEAKING FUEL INJECTORS ON #1 GENERATOR.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Engineering
Issued 18 July 1996
Resolved
REPAIR DISCONNECTED COOLING WATERLINE ON #2 GENERATOR. (SOLAS 60 I-10) CORRECT PRIOR TO DEPARTURE FROM PORT OF NEW ORLEANS.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Engineering
Issued 18 July 1996
Resolved
REPAIR LEAKING FUEL LINES AND FUEL INJECTORS ON MAIN PROPULSION. (SOLAS 60 I-10). CORRECT PRIOR TO DEPARTURE FROM PORT OF NEW ORLEANS.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Lifesaving
Issued 18 July 1996
Resolved
REPAIR DAMAGED/HOLED STARBOARD LIFEBOAT HULL, DECKING AND CORRECT MOTOR EXHAUST SYSTEM. ALSO MAKE SOLAS COVER FOR PORT LIFEBOAT SERVICABLE.
Condition: Unknown
Due 6 February 1997
Resolved 18 February 1997