Records from 1985 to 2013. Most recent: casualty investigation, 3 September 2013.
Construction/Loadline › Hull › Bottom Plating
Issued 3 June 2008
No resolution recorded
Port stern quarter leaking at bottom plate. Repair and clean steering compartment . Make all compartments clean and dry for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2008 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 June 2008
No resolution recorded
Stbd engine exhaust has sea water leaking through seal at stern. Make permanent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2008 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Pump
Issued 3 June 2008
No resolution recorded
Steering compartment electric submersible bilge pump not operating, bilge full of water and automatic switch submerged. Based on condition of equipment it appears to have been this way for some time. Bilges tested by O/Op during last visit, inspector at steering station. Wires to switch are exposed and may have been jump to appear to have operated properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2008 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 June 2008
No resolution recorded
Stbd side at waterline through hull fitting capped and leaking. Repair to satisfaction of attending USCG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2008 — due date passed with no resolution recorded
Construction/Loadline › Structures › Deck Plating
Issued 3 June 2008
No resolution recorded
Remove doubler on deck iwo sterring compartment hatch and properly repair deck and supports around aft hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2008 — due date passed with no resolution recorded
Construction/Loadline › Structures › Manhole
Issued 3 June 2008
No resolution recorded
All exposed hatches on the main deck are to be made water tight and have chanins attached.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2008 — due date passed with no resolution recorded
Documentation › Certificates/Documents › FCC SSL
Issued 5 May 2008
Resolved
Provide onboard FCC Safety Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Documentation › Certificates/Documents › Stability Letter
Issued 5 May 2008
No resolution recorded
Provide onboard Stability Letter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 May 2008
Resolved
Remove Radar wires from cabin. Rec. removal of Radar Array.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency. Radar Array still mounted on vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 May 2008
Resolved
Provide onboard alcohol test kits for each crewmember.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 3 June 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 May 2008
No resolution recorded
Provide up to date Coast Pilot and Light List.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Cable
Issued 5 May 2008
Resolved
Remove all loose wires on aft section of upper deck house.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Lifesaving › Lifefloat › Paddle
Issued 5 May 2008
Resolved
Replace three oars for life floats at least 4ft in length.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 3 June 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Lifesaving › Lifefloat › Float-free Link
Issued 5 May 2008
Resolved
Provide new weak link for all three life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 3 June 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Engineering › Steering Gear System › Hydraulic Hose
Issued 5 May 2008
Resolved
Repair hydraulic leak under steering consul.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Communications › Alarms/Indicators › High Water Alarm
Issued 5 May 2008
Resolved
Ensure all 5 highwater alarms are mounted properly and operate satisfactory.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 3 June 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 5 May 2008
Resolved
Replace anchor windless, wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Lifesaving › Hand Flares › Expired
Issued 5 May 2008
Resolved
Replace expired flares total six.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Construction/Loadline › Hull › Hull Plating
Issued 5 May 2008
Resolved
Repair Stbd side planks in fuel compt. Light shining through near waterline (as marked).
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 May 2008
Resolved
Remove hydraulic fluid which leaked from steering station two decks above from fuel tank compartment bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 5 May 2008
Resolved
Properly secure hydraulic lines for anchor windlass.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Construction/Loadline › Hull › Hull Plating
Issued 5 May 2008
Resolved
Repair port side planks in engine room. Light shining through near waterline.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 5 May 2008
Resolved
Port shaft coupling leaking extensively. Repair to satisfaction of OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2008
No resolution recorded
Provide on board new first aid kit with all required medications.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 May 2008
Resolved
Remove batteries from battery box and clean box and battery terminals. Replace securely in box.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Construction/Loadline › Structures › Door
Issued 5 May 2008
Resolved
Side doors (4) on main deck do not open and close properly. Repair/replace and prove proper operation of all doors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 3 June 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 May 2008
No resolution recorded
All bilges in each compartment need to be cleaned with all oils removed and made ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 May 2008
Resolved
Provide chain and sign at top of ladder to second deck stating "No Passengers Allowed" or "Crew Only".
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 23 May 2008
Resolution: Attended vessel to conduct DefCk,cleared above deficiency.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 October 2007
No resolution recorded
Owner failed to make vessel available for inspection within 90 days prior to or after the anniversary date of 13 June 2007.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2007 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 17 May 2007
Resolved
Secure Stbd sewage tank.
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 1 June 2007
Resolution: Made brackets from 2"Xa4" to secure sewage tank.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2007
Resolved
Remove all dead ended wires from engine room and 2 compartments aft of the engine compartment.
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 1 June 2007
Resolution: Removed dead ended wire. Also replaced taped connections with squeeze type connectors.
Construction/Loadline › Hull › Transverse Frame
Issued 17 May 2007
Resolved
2nd compartment fwd of the transom, secure replace and repair wasted brackets, transverse frames and side shell frames at top (as marked).
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2007
Resolved 1 June 2007
Resolution: Replaced wasted braekets and side shell frames at top.
Construction/Loadline › Hull › Transverse Frame
Issued 17 May 2007
Resolved
Lazarette, secure transverse frame fwd of rudder post, secure hull plating on Port and Stbd side aft at chine, replace bracket wasted port side 1st fwd of transom (as marked).
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2007
Resolved 1 June 2007
Resolution: Wasted bracket replaced. Transverse frame fwd of rudder post, rebolted. Hull plating on port and stbd side aft had more wood screws drilled in from outside the vessel up into the frames to pull the planks flush with rest of the bottom planks.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 1 June 2006
Resolved
Amperes guage on bridge stbd engine fractured repair/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2006
Resolved 7 June 2006
Resolution: New cover on guage.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 June 2006
Resolved
Bilge pump indicators on bridge for Batt/Eng/Fuel space not working repair/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2006
Resolved 7 June 2006
Resolution: Repaired and tested sat.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 1 June 2006
Resolved
Fireboy test failed to shut down stbd engine repair and have tested by certified technician.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2006
Resolved 7 June 2006
Resolution: Tested fireboy shutdown no deficiencies noted.
Electrical › Electric Generation Source (service) › Switch
Issued 1 June 2006
Resolved
Permanently mount all battery switches.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2006
Resolved 7 June 2006
Resolution: Battery switches permanently mounted.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 1 June 2006
Resolved
Stbd shaft coupling leaking excessively. Repair.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2006
Resolved 7 June 2006
Resolution: Witnessed operation of stbd shaft, no deficiencies noted.
Engineering › Steering Gear System › Bracket/Clamp
Issued 1 June 2006
Resolved
Secure mounting block for hydraulic steering ram base.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2006
Resolved 7 June 2006
Resolution: Witnessed proper repair and operation of steering system.
Engineering › Steering Gear System › Rudder
Issued 1 June 2006
Resolved
Rudder post leaking excessively repair.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2006
Resolved 7 June 2006
Resolution: Witnessed proper repair and operation of stbd rudder post.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 1 June 2006
Resolved
Make all bulkheads watertight.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 7 June 2006
Resolution: O/Op stated vessel bulkheads were again water tight.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 1 June 2006
Resolved
Water leaking from block attached to port shaft coupling. Repair/stop leak prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2006
Resolved 7 June 2006
Resolution: Shaft coupling and base attached to block dry.
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 June 2006
Resolved
Marine Radar inop. Repair/remove.
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 26 July 2006
Resolution: Received call from O/Op stating that the radar had been removed from pilot house.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 June 2006
Resolved
Stern Light missing. Replace IAW rules of the road.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2006
Resolved 7 June 2006
Resolution: O/Op stated above repairs were made.
Engineering › Feedwater/Condensate Water System › Pump
Issued 13 June 2005
Resolved
iNSTALL DOUBLE CLAMPS ON WASHDOWN PUMP.
Due 13 July 2005
Resolved 16 June 2005
Resolution: Clamps installed.
Construction/Loadline › Penetrations › Valve Flange
Issued 13 June 2005
Resolved
Install cap on thru hull fitting in engine room.
Due 13 July 2005
Resolved 16 June 2005
Resolution: Cap installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 June 2005
Resolved
Make aft watertight blkhd, watertight.
Due 13 July 2005
Resolved 16 June 2005
Resolution: holes plugged.
Lifesaving › Embarkation Appliances/Stations › Handholds
Issued 13 June 2005
Resolved
Provide rescue ladder for man overboard operations.
Due 13 July 2005
Resolved 16 June 2005
Resolution: Ladder provided.
Electrical › Electrical Distribution System (service) › Busway
Issued 3 September 2004
Resolved
Remove all dead-end wiring in engine compt.
Action required: 705 - Other - as specified
Due 1 October 2004
Resolved 13 June 2005
Resolution: wiring removed.
Engineering › Bilge Water Management System › Manifold
Issued 3 September 2004
Resolved
Prior to 31MAR05, remove old, out of service, bilge manifold system.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 13 June 2005
Resolution: removed.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 3 September 2004
Resolved
Prior to 31OCT04, provide port engine for sea trials.
Action required: 705 - Other - as specified
Due 31 October 2004
Resolved 13 June 2005
Resolution: Engine installed and satisfactory sea trials completed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 August 2004
Resolved
Prior to carrying passengers, replace High Water Alarm in fuel tank space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2004
Resolved 3 September 2004
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 6 August 2004
Resolved
Prior to carrying passengers, replace fire pump and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 6 August 2004
Resolved
Prior to carrying passengers, repair exhaust leaks on starboard engine exhaust in 3 compartments.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 6 August 2004
Resolved
Prior to 31 Oct 04, renew port engine to proper operation and provide for sea trials.
Action required: 705 - Other - as specified
Due 31 October 2004
Resolved 3 September 2004
Resolution: Reissued.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 6 August 2004
Resolved
Remove all scale and rust form tops of fuel tanks and provide for gageing.
Due 20 August 2004
Resolved 2 September 2004
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 6 August 2004
Resolved
Prior to carriage of pasengers or secure head from use, replace sewage tank.
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 3 September 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 August 2004
Resolved
Prior to carrying passengers, replace bracket for Life Ring waterlight.
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 3 September 2004
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 6 August 2004
Resolved
Prior to carrying passengers, tighten packing or repack the starboard rudder and the starboard shaft.
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 2 September 2004
Documentation › Markings/Placards › Capacity Marking
Issued 6 August 2004
Resolved
Prior to carrying passengers, repaint sign for "No passengers on the upper deck."
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 6 August 2004
Documentation › Markings/Placards › Warning Signs
Issued 6 August 2004
Resolved
Prior to carrying passengers, renew "Emergency Fuel Shutoff" sign.
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 6 August 2004
Documentation › Markings/Placards › Warning Signs
Issued 6 August 2004
Resolved
Prior to carrying passengers, label all High Water Alarms and Bilge Operation indicators lights at the operating station.
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 2 September 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 12 May 2004
Resolved
Prior to carrying passengers, service all fire extinguishers and fixed fire fighting equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2004
Construction/Loadline › Hull › Side Shell
Issued 12 May 2004
Resolved
Prior to carrying passengers, prove that weepage in stern compartment just needs wood to swell up after being out of water in order for stream of water to stop. LEGACY COMPONENT DESC: Chine
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2004
Resolved 6 August 2004
Construction/Loadline › Penetrations › Bottom Plug
Issued 29 April 2004
Resolved
Prior to refloating vessel, replace 2 bolts on the stern tube of the port shaft. LEGACY COMPONENT DESC: Stern Tube
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2004
Resolved 12 May 2004
Construction/Loadline › Penetrations › Bottom Plug
Issued 29 April 2004
Resolved
Prior to refloating vessel, replace wood around exhaust ports on stern. LEGACY COMPONENT DESC: Exhaust Port
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2004
Resolved 12 May 2004
Construction/Loadline › Hull › Side Shell
Issued 29 April 2004
Resolved
Prior to carrying passengers, replace wood borer infested plank just under deck, port side in 4th compartment from stem. LEGACY COMPONENT DESC: Side Plank
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2004
Resolved 6 August 2004
Construction/Loadline › Hull › Transverse Frame
Issued 29 April 2004
Resolved
Prior to carrying passengers, replace rotten frames in aft compartment. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2004
Resolved 12 May 2004
Construction/Loadline › Hull › Transverse Frame
Issued 29 April 2004
Resolved
Prior to carrying passengers, sister or replace cracked frame in #1 compartment port side 2nd frame. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2004
Resolved 2 September 2004
Construction/Loadline › Penetrations › Bottom Plug
Issued 29 April 2004
Resolved
Prior to carrying passengers, plug or provide stuffing box for all openings through collision bulkhead. LEGACY COMPONENT DESC: Collision Bulkhead Penatrations
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2004
Resolved 3 September 2004
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 April 2004
Resolved
Gage thickness of steel fuel tanks to determine the amount of wastage or replace. LEGACY COMPONENT DESC: Tank Thickness
Action required: 705 - Other - as specified
Resolved 6 August 2004
Resolution: Not resolved but rewrote 835 to include the removal of rust and scaling.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 April 2004
Resolved
Prior to carrying passengers, replace lagging on starboard engine exhaust or prove that pipe does not get hot. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2004
Electrical › Electric Supply System (service)
Issued 29 April 2004
Resolved
Prior to carrying passengers, get all battery cables ties up and out of bilges. LEGACY COMPONENT DESC: Cable
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2004
Construction/Loadline › Penetrations › Bottom Plug
Issued 29 April 2004
Resolved
Prior to carrying passengers, cap all unused thru hull openings. LEGACY COMPONENT DESC: Thru-Hull
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2004
Resolved 2 September 2004
Engineering › Bilge Water Management System › Manifold
Issued 29 April 2004
Resolved
Prior to Mar 31, 2005, remove old, unsued manifold system, LEGACY COMPONENT DESC: Manifold
Due 31 October 2004
Resolved 3 September 2004
Resolution: Reissued.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 29 April 2004
Resolved
Remove old, unsued electrical box and wiring, starboard side forward of the engine room and all other unused wiring. LEGACY COMPONENT DESC: Distribution Panel Bus
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 3 September 2004
Resolution: Rerissued.
Construction/Loadline › Hull › Keel
Issued 29 April 2004
Resolved
Prior to 5/31/04, provide plan for keel bolt replacement in aft of the vessel. LEGACY COMPONENT DESC: Keel
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 6 August 2004
Engineering › Bilge Water Management System › Interface Detector
Issued 29 April 2004
Resolved
Prior to carrying passengers, replace float switch in fuel tank space such that the wiring connection is well above the bilge waterline. LEGACY COMPONENT DESC: Float Switch
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2004
Construction/Loadline › Hull › Weld
Issued 29 April 2004
Resolved
Prior to 5/31/04, provide plan for chine bolt and floor timber/frame bolt replacement in aft of the vessel. LEGACY COMPONENT DESC: Fasteners
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 6 August 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 May 2003
Resolved
Prior to carrying passengers: provide current servicing of all fire extinguishers and fixed fire fighting systems and demonstrate auto-engine shut down to marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 6 May 2003
Resolved
Prior to carrying passengers: Cap and seal opening in top of sewage tank.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Construction/Loadline › Penetrations › Valve Flange
Issued 6 May 2003
Resolved
Prior to carrying passengers: Cap unused thru-hull pipes for ol keel coolers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Lifesaving › Buoyant Apparatus
Issued 6 May 2003
Resolved
Prior to carrying passengers: Renew lines to life float platforms and all life lines. Renew reflective tape. Label Buoyant Apparatus with name and number of passengers. Properly reattach all to the sea painter and provide a water light for each. LEGACY COMPONENT DESC: Lines
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 May 2003
Resolved
Prior to carrying passengers: Renew vessel name on life ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 May 2003
Resolved
Prior to carrying passengers: Provide proof of enrollment of all employee's in current drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Construction/Loadline › Structures
Issued 6 May 2003
Resolved
To be completed at next haul out: Renew rotten toerail on portside of 2nd deck just above door into the aft main cabin on the 1st deck. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 May 2004
Construction/Loadline › Hull
Issued 6 May 2003
Resolved
To be completed at next haul out: Renew wood corrosion around port and stbd exhausts on the transom. LEGACY COMPONENT DESC: Transom
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 May 2004
Construction/Loadline › Hull
Issued 6 May 2003
Resolved
To be completed at next haul out: Renew tops of side frames port side in the aft compartment. LEGACY COMPONENT DESC: Frames
Action required: 705 - Other - as specified
Resolved 12 May 2004
Engineering › Bilge Water Management System
Issued 6 May 2003
Resolved
Renew light for Engine Room bilge pump. LEGACY COMPONENT DESC: Indicator Lights
Condition: Improper/Lack of Maintenance
Due 20 May 2003
Resolved 6 May 2003
Resolution: Replaced the switch.
Engineering › Bilge Water Management System
Issued 6 May 2003
Resolved
Renew High Water Alarms so that they all light properly and label each light as to its compartment.
Due 20 May 2003
Resolved 6 May 2003
Resolution: Wires corroded, replaced all corroded wires.
Construction/Loadline › Hull
Issued 24 April 2002
Resolved
Renew 2nd-4th Starboard Side frames in battery compartment and 6th frame Port Side (counting from aft). LEGACY COMPONENT DESC: FRAME
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2002
Construction/Loadline › Hull
Issued 24 April 2002
Resolved
Renew 2nd and 3rd starboard side frames in steering compartment, LEGACY COMPONENT DESC: Frame
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2002
Construction/Loadline › Hull
Issued 24 April 2002
Resolved
Address rotten planking in aft Stbd Side corner next to transom. LEGACY COMPONENT DESC: Planking
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2002
Engineering › Shafting/Propeller Arrangements
Issued 24 April 2002
Resolved
Renew bolts to port side shaft bracket. LEGACY COMPONENT DESC: Bolts
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2002
Construction/Loadline › Hull
Issued 24 April 2002
Resolved
Renew 2nd & 3rd frames port side in forepaek. LEGACY COMPONENT DESC: Frames
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2002
Construction/Loadline › Hull
Issued 24 April 2002
Resolved
Renew backing plate in Port & Stbd stem just under the deck. LEGACY COMPONENT DESC: Backing plate
Action required: 705 - Other - as specified
Resolved 12 May 2004
Engineering
Issued 19 November 2001
Resolved
RERUN EMERGENCY FUEL SHUT OFF CABLE SUCH THAT FUEL VALVE SHUTS OFF COMPLETELY, PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 25 November 2001
Resolved 12 December 2001
Construction/Loadline
Issued 19 November 2001
Resolved
RENEW ROTTED WOOD IN DECK HOUSE & ENTRY INTO PILOT HOUSE.
Condition: Unknown
Due 24 April 2002
Resolved 24 April 2002
Lifesaving
Issued 19 November 2001
Resolved
PROVIDE SIGN SAYING "NO PASSENGERS ON UPPER DECK" ON LADDER TO 01 DECK.
Condition: Unknown
Due 25 November 2001
Resolved 12 December 2001
Lifesaving
Issued 19 November 2001
Resolved
REPAIR WATERLIGHT BRACKETS/STANDS FOR THE WATERLIGHTS FOR THE LIFE FLOATS.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Electrical
Issued 19 November 2001
Resolved
REAPIR OR REMOVE ALL DEAD END AND BROKEN WIRING IN ALL SPACES.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 12 May 2004
Lifesaving
Issued 19 November 2001
Resolved
RENEW LINES FOR LIFE FLOAT PLATFORM FOR 1 15 PERSON LIFE FLOAT. RENEW PADDLES FOR BOTH PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 25 November 2001
Resolved 12 December 2001
Construction/Loadline
Issued 19 November 2001
Resolved
PROVE PROPER OPERATION OF ALL BILGE PUMPS AND ALL HIGH WATER ALARMS PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 25 November 2001
Resolved 12 December 2001
Construction/Loadline
Issued 19 November 2001
Resolved
REPLACE/REPAIR DECK DRAINS AND HOSES WHICH TRAVEL THROUGH 2ND COMPARTMENT FROM STERN PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 25 November 2001
Resolved 12 December 2001
Accommodation/Occupational Safety
Issued 19 November 2001
Resolved
REPAIR/TIGHTEN RAILING ON STARBOARD BOW PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 25 November 2001
Resolved 12 December 2001
Navigation
Issued 19 November 2001
Resolved
REPAIR HYDRAULIC LEAK IN STEERING SYSTEM IN PILOT HOUSE PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 25 November 2001
Resolved 12 December 2001
Accommodation/Occupational Safety
Issued 19 November 2001
Resolved
REPAIR/TIGHTEN RAILING ON 2ND DECK PRIOR TO CARRIAGE OF PASSENGERS ON THE 2ND DECK.
Condition: Unknown
Due 28 February 2002
Resolved 24 April 2002
Construction/Loadline
Issued 19 November 2001
Resolved
REPAIR SOFT SPOT IN DECK ON 2ND DECK PRIOR TO CARRIAGE OF PASSENGERS ON THE2ND DECK.
Condition: Unknown
Due 28 February 2002
Resolved 24 April 2002
Lifesaving
Issued 25 April 2001
Resolved
RENEW REFLECTIVE TAPE ON 36 ADULT AND 4 CHILD LIFE JACKETS. VSL NOT TO CARRY MORE THAN 74 ADULTS AND 7 CHILDREN UNTIL COMPLETE.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Construction/Loadline
Issued 25 April 2001
Resolved
CORRENT MALFUNSTION OF BILGE PUMP LIGHTS AT OPERATING STATION.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Engineering
Issued 25 April 2001
Resolved
RENEW STBD OIL PRESSURE GAGE.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 25 April 2001
Resolved
LABEL RING BUOY AND 11 PERSON BUOYANT APPARATUS WITH VSL NAME PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 25 May 2001
Resolved 9 July 2001
Electrical
Issued 27 April 2000
Resolved
REPLACE LIGHTS WITHOUT GLOBES WITH SAFETY LIGHTS.
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Construction/Loadline
Issued 27 April 2000
Resolved
REPAIR UPPER PART OF #9 PORT DECK SUPPORT BEAM IN ENG ROOM
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Construction/Loadline
Issued 27 April 2000
Resolved
ADD/REPLACE CAPTURE CABLES ON FORWARD AND AFT HATCH COVERS.
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Accommodation/Occupational Safety
Issued 27 April 2000
Resolved
TIGHTEN SECOND STANTION PORT SIDE
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Construction/Loadline
Issued 27 April 2000
Resolved
RENEW SCREWS IN OUTER EXHAUST PORTS.
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Construction/Loadline
Issued 27 April 2000
Resolved
REPAIR BROKEN WINDOW ON PORT SIDE.
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Engineering
Issued 27 April 2000
Resolved
REPLACE STBD CUTLASS BEARING WITH ONE THE RIGHT SIZE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Accommodation/Occupational Safety
Issued 27 April 2000
Resolved
RESTRING CABLE ON FWD STARBOARD STANTIONS.
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Accommodation/Occupational Safety
Issued 27 April 2000
Resolved
LABEL/STENCIL UPPER DECK FOR MAX PASSENGERS.
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Accommodation/Occupational Safety
Issued 27 April 2000
Resolved
TIGHTEN LADDER TO UPPER DECK.
Condition: Unknown
Due 27 May 2000
Resolved 7 June 2000
Unknown
Issued 18 November 1999
Resolved
Clean bilges. Remove trash and oil.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Deck/Cargo
Issued 18 November 1999
Resolved
Repair leak on anchor windlass
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Construction/Loadline
Issued 18 November 1999
Resolved
Replace bilge piping in accordance with 46 CFR 182.510 and install check valves in each bilge line.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Fire Fighting
Issued 18 November 1999
Resolved
Provide fire hose.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Construction/Loadline
Issued 18 November 1999
Resolved
Cap through hull fitting starboard side of engine room (old MSD discharge).
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Fire Fighting
Issued 18 November 1999
Resolved
Mount B-I fire extinguisher in bracket in pilothouse.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Fire Fighting
Issued 18 November 1999
Resolved
Provide proof of servicing for B-II Fire Extinguisher.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Engineering
Issued 18 November 1999
Resolved
Repair and prove proper operation of emergency fuel shutoff valve for starboard tank.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Electrical
Issued 18 November 1999
Resolved
Hang wires with metal wire hangers in 24 inch intervals.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Navigation
Issued 18 November 1999
Resolved
Provide and prove proper operation of VHF radio.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Construction/Loadline
Issued 18 November 1999
Resolved
Double clamp hose for starboard engine raw water inlet (at through-hull)
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Unknown
Issued 18 November 1999
Resolved
Complete underway portion of inspection including drills and prove proper operation of all systems.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Construction/Loadline
Issued 18 November 1999
Resolved
Double clamp through-hull hoses on bilge and raw water lines.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Construction/Loadline
Issued 18 November 1999
Resolved
Cap unused bilge pipe starboard side of engine room, at forward end of engine.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999
Construction/Loadline
Issued 18 November 1999
Resolved
Label bilge alarm panels with appropriate compartment name.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Construction/Loadline
Issued 18 November 1999
Resolved
Label bilge pump controls with appropriate compartment name.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Unknown
Issued 18 November 1999
Resolved
Provide and post an emergency radio broadcast placard.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Engineering
Issued 4 May 1995
Resolved
REPAIR LEAK AT PORT MAIN ENGINE COOLING WATER PUMP.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Electrical
Issued 4 May 1995
Resolved
REPLACE TWO WASTED FASTENERS IN AREA OF LEAKAGE AT FORWARD BULKHEAD PORTSIDE OF BATTERY COMPARTMENT
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Construction/Loadline
Issued 29 April 1994
Resolved
REPLACE FRACTURED BUTT BLOCK STARBOARD SIDE AFTER ENGINE ROOM.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
CROP BACK TO GOOD WOOD (MINIMUM 5') AND REPLACE IN KIND 1 1/2" BOTTOM PLANKSTARBOARD SIDE OF ENGINE ROOM WHERE HOLED AND ROTTEN, REPLACE CORRESPONDINGBUTT BLOCK AT SAME LOCATION.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
FREE UP AND PROVE WATERTIGHT ALL WEATHERDECK HATCHES.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REFASTEN WATERTIGHT BULKHEAD BETWEEN LAZARETTE AND BATTERY COMPARTMENT (STARBOARD SIDE).
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
CROP TO GOOD WOOD AND REPLACE IN KIND (MINIMUM 5') BOTTOM PLANK STARBOARD QUARTER WHERE ROTTEN, AND CORRESPONDING BUTT BLOCK (ABOVE CHINE).
Condition: Unknown
Due 29 April 1994
Resolved 5 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REMOVE AND REPLACE IN KIND STARBOARD SIDE SHELL PLANK WHERE FRACTURED (4 PLACES).
Condition: Unknown
Due 29 April 1994
Resolved 5 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REMOVE, REPLACE AND REBOLT KNEE AT STARBOARD QUARTER IN WAY OF TRANSOM.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REPLACE ALL CHINE BOLTS AT CHINE PLANK BUTTS (4 EACH SIDE) FOR A TOTAL OF 32 BOLTS.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REMOVE AND REPLACE IN KIND FOUR STRIP PLANKS PORT SIDE FORWARD WHERE FRACTURED.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REMOVE AND REPLACE IN KIND PLANK AT RUBRAIL PORT SIDE FORWARD WHERE ROTTEN.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REFASTEN BOTTOM PLANKS AT PORT QUARTER WHERE MARKED AND DISCUSSED.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REFASTEN THREE BOTTOM PLANKS STARBOARD QUARTER WHERE MARKED AND DISCUSSED.
Condition: Unknown
Due 29 April 1994
Resolved 5 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REMOVE AND REPLACE IN KIND STRIP BOTTOM PLANK STARBOARD SIDE FORWARD WHERE FRACTURED.
Condition: Unknown
Due 29 April 1994
Resolved 5 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REMOVE AND REPLACE IN KIND STRIP SIDE SHELL PLANKS STARBOARD SIDE FORWARD AT RUB RAIL WHERE ROTTEN.
Condition: Unknown
Due 29 April 1994
Resolved 5 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
REPLACE VALVE HANDLE AND BILGE SUCTION STRAINER IN FORWARD VOID.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Construction/Loadline
Issued 29 April 1994
Resolved
MAKE PERMANENT REPAIRS TO FRACTURED FRAME IN #2 VOID SPACE, FRAME #9 FROM BOW LEADING AFT ON PORT SIDE.
Condition: Unknown
Due 29 April 1994
Resolved 4 May 1994
Engineering
Issued 23 April 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE AND PRIOR TO CARRYING PASSENGERS REPLACEEXHAUST PIPING BOR BOTH MAIN ENGINES IN BATTERY COMPARTMENT AND LAZARETTE SPACE.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Lifesaving
Issued 23 April 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE AND PRIOR TO CARRYING PASSENGERS PROVIDEEIGHT ADDITIONAL ADULT TYPE 1 PFD'S.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Lifesaving
Issued 23 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Engineering
Issued 23 April 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE AND PRIOR TO CARRYING PASSENGERS PROVE PROPER OPERATION ON BOTH MAIN ENGINES.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Lifesaving
Issued 13 May 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Electrical
Issued 13 May 1992
Resolved
PROVE PROPER OPERATION OF SHIP GENERATOR.
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Lifesaving
Issued 13 May 1992
Resolved
PRIOR TO PLACING VESSEL IN OPERATION RENEW AND PROPERLY MOUNT ALL LIFEFLOATS AND BUOYANT APPARATUS.
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Construction/Loadline
Issued 5 May 1992
Resolved
RENEWED FOUR (4) PLANKS STARBOARD SIDE BOTTOM AS RESULT OF REMOVAL OF THROUGH HULL TRANSDUCER FOR SONAR.
Condition: Unknown
Due 5 May 1992
Resolved 2 June 1992
Electrical
Issued 17 April 1990
Resolved
WATERLITE STARBOARD WHEELHOUSE MISSING BRACKET. PROVIDE APPROVED BRACKET FOR WATERLITE.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Fire Fighting
Issued 17 April 1990
Resolved
FIRE EXTINGUISHERS NOT PROPERLY MOUNTED. PROVIDE APPROVED BRACKETS FOR ALLFIRE EXTINGUISHERS.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Deck/Cargo
Issued 17 April 1990
Resolved
HEAT SHIELD MISSIG FROM FUEL FILTER/SEPARATOR ASSEMBLY STARBOARD MAIN ENGINE. PROVIDE USCG ACCEPTED HEAT SHIELD FOR FILTER/SEPARATOR ASSEMBLY.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Lifesaving
Issued 17 April 1990
Resolved
18 PERSON BOUYANT APPARATUS IN DISREPAIR, COVER SPLIT AND CRACKED. UN- SATISFACTORY REPAIR MADE USING DUCT TAPE. RENEW OR PROFESSIONALLY RECOND- ITION LIFE FLOAT IN ACCORDANCE WITH NVIC 2/63. TO BE COMPLETED PRIOR TO CARRYING MORE THAN 84 PERSONS.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Lifesaving
Issued 17 April 1990
Resolved
5 ADULT AND ONE CHILD LIFE PRESERVERS REJECTED. PROVIDE ADDITIONAL LIFE PRESERVERS TO BRING TOTAL LIFE PRESERVERS ONBOARD TO 110 ADULT AND 11 CHILDVESSEL LIMITED TO 105 TOTAL PERSONS UPON COMPLETION OF REQUIREMENT 4.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Lifesaving
Issued 14 April 1988
Resolved
RENEW LIFE LINES ON B/A
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Lifesaving
Issued 14 April 1988
Resolved
PROVIDE 06 TYPE I PFDS.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Electrical
Issued 14 April 1988
Resolved
LOOSE WIRING IN MULTIPLE AREAS.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988