Records from 1996 to 2010. Most recent: inspection, 5 October 2010.
Inspection history · 44
5 October 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3863858
18 April 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3455279
2 March 2009
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3426669
22 January 2009
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3398100
22 January 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3398175
2 December 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3372912
22 September 2008
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3330090
17 September 2008
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3326660
16 September 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3326049
16 September 2008
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3326284
12 September 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3323329
11 September 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3324503
10 September 2008
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3321971
10 July 2008
ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3263207
18 November 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3100484
15 June 2007
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2962355
30 May 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2946777
6 April 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2903340
6 April 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2904520
28 August 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2761777
3 May 2006
MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2639559
5 August 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2156852
5 August 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2156912
26 July 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2145058
26 July 2004
ISM Exam · MARPOL Annex I Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2145472
25 July 2004
ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2144164
25 July 2004
NPV Safety Exam · MARPOL Annex I Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2153948
27 May 2004
MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2079891
21 January 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1989260
19 January 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1988156
16 July 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1848448
15 July 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1847286
2 February 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1738527
13 August 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1719780
9 July 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1643723
18 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 277011
2 March 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 275844
2 March 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 276080
10 October 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 421359
12 September 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 407618
12 September 1997
Passenger/Freight Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1121849
30 September 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 395927
30 September 1996
Passenger/Freight Vessel Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 833686
10 August 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 394178
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 5 October 2010
No resolution recorded
Lagging surrounding cylinders 9 and 12 on main engine are soaked with fuel. In its current condition this poses an increased risk of fire. cite: SOLAS 97 Reg I/II
Action required: 705 - Other - as specified
Due 4 November 2010 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 October 2010
No resolution recorded
Railing on uppermost level of engine room is damaged in section nearest the engine control room door. In its current condition this railing is not serving to its maximum level of safety. cite: SOLAS 97 REG I/II
Action required: 705 - Other - as specified
Due 4 November 2010 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 March 2009
Resolved
02March2009 received LOD request for inopperable S-band radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2009
Resolution: Received Tech Report all Sat.
Engineering › Compressed Air System (start air) › Compressor
Issued 22 January 2009
Resolved
Main machinery and essential auxiliaries operating unsastifactorily and with no excessive fuel, lube oil, or water leakages shielding of high pressure oil fuel lines missing. Request class report attesting to the condition and proper operation of MDE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2009
Resolution: CG and Class conducted tests on MDE jointly. Found no reason for the problem to have occured. Considered a hiccup in the system. Rcvd class report attesting to proper operation of MDE.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 16 September 2008
Resolved
Vessel experienced a loss of power during inbound transit due to an overspeed trip brought on by Aux Engine #2. Vsl unable to restart engine following loss of power. Class surveyor to attest to proper functioning of propulsion systems.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2008
Resolution: Vessel provided tech report attesting to proper repair and testing of propulsion systems (see attached). Class surveyor provided report attesting to proper repair and testing of propulsion and power systems. Deficiency administratively cleared.
Engineering › Feedwater/Condensate Water System › Piping
Issued 16 September 2008
Resolved
Condensate return line for the HFO service tank is leaking water. Class surveyor to attest to proper repairs.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 September 2008
Resolution: Condensate return line repaired to Class Surveyor''s satisfaction. Survey attached.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 16 September 2008
Resolved
Quick close valve for the HFO settling tank is locked in the open position. Crew uses fabricated means of closing valve. Class surveyor to attest to proper repairs.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 September 2008
Resolution: Quick close valve for HFO settling tank repaired to Class Surveyor''s satisfaction. Survey attached.
Construction/Loadline › Markings › Load Line Mark
Issued 10 July 2008
Resolved
Loadlines are not in contrasting color to hull. Paint to satisfaction of attending classification surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2008
Resolved 10 September 2008
Resolution: Recieved class report atesting to Load line marks painted with contrasting colors.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 10 July 2008
Resolved
Electrical control switch panels do not have non-conductive mats or grating to protect personnel from electrical shock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2008
Resolved 10 September 2008
Resolution: Recieved class report atesting to electrical control room fitted with rubber conductibe matting.
Engineering › Fuel Oil Service System › Piping
Issued 10 July 2008
Resolved
Main engine fuel oil return line leaking at flange creating a fire hazard in the engine room and a slip and trip hazard due to oil leaking onto the deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2008
Resolved 10 September 2008
Resolution: Recieved class report atesting to new gasket fitted on the main diesel engine flange.
Engineering › Freshwater System (jacketwater cooling) › Accumulator
Issued 10 July 2008
Resolved
The low temp water heat exchanger excessively leaking at broken fin assembly. Repair to the satisfaction of the attending classification society surveyor.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2008
Resolved 10 September 2008
Resolution: Recieved class report atesting to The Heat Exchanger overhauled by ship engineer, same found in good order with no leakages.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 10 July 2008
Resolved
Emergency generator hydraulic start is inoperable due to fuel cut off malfunction at injection pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2008
Resolved 10 July 2008
Resolution: Chief engineer replaced defective fuel cut off screw at injection pump shut down. Corrected to the satisfaction of the USCG.
Engineering › Feedwater/Condensate Water System › Piping
Issued 10 July 2008
Resolved
Fresh water steam condensor has a soft patch on the output side of pipe. Repair to the satisfaction of attending classification society.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2008
Resolved 10 September 2008
Resolution: Recieved class report atesting to new fabrication of Fresh water oulet pipe and replacement.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 May 2007
Resolved
Vessel's Oily Water Separator supply pump motor was found inoperable. Crew stated that the replacement part has been ordered. Vessel may not us Oily Water Separating stem until repairs have been made, and a satisfactory test has been conducted to the satisfaction of the attending Classification Society surveyor.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 June 2007
Resolved 15 June 2007
Resolution: Received satisfactory Classification Society surveyor report attesting to repairs.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 May 2007
Resolved
Desiccator on Oily Water Separator oil content meter is displaying the color white indicating expiration. Vessel must replace part to the satisfaction of attending Classification Society surveyor prior to operating Oily Water Separator.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 June 2007
Resolved 15 June 2007
Resolution: Received satisfactory Classification Society surveyor report attesting to repairs.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 May 2007
Resolved
Vessel's steering gear space was observed saturated with hydraulic fluid. This causes a significant risk of injury to crew. No active leaking was discovered during inspection.
Condition: Unknown
Due 30 May 2007
Resolved 30 May 2007
Resolution: deficiency cleared onboard.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 3 May 2006
Resolved
Main fire pump leaking around pump shaft. Determine source of leak and make permanent repairs to the satisfaction of attending class surveyor NLT 6/3/06.
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 28 August 2006
Resolution: As per Class Report; Main fire pump No.2 was overhauled. Hose test was conducted and all was found satisfactory.
Fire Fighting › International Shore Connection › Gasket
Issued 3 May 2006
Resolved
Both International Shore Connections missing required gasket. Obtain gasket material and place with each connection to the satisfaction of attending class surveyor NLT 6/3/06.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 28 August 2006
Resolution: As per Class Report; New gaskets and bolts have been received and assigned to each box.
Fire Fighting › Ventilation Systems › Fans
Issued 3 May 2006
Resolved
Control box IWO fire flap, starboard side, aft main deck wasted and loosely hanging. Make permanent repairs to the satisfaction of attending class surveyor NLT 6/3/06.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 28 August 2006
Resolution: As per Class Report; A complete box has been installed to replaced the old one.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 July 2004
Resolved
Verification of proper maintenance of OWS must be provided by owner/operator to the satisfaction of the classification society's representative. Failure to comply will result in the removal of all oily waste prior to departing from Los Angeles/Long Beach
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 September 2004
Resolution: Duplicate requirement
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 26 July 2004
Resolved
There are various oil leaks though the engine room and hydraulic leaks in the steering flat. Remove excess oil and repair leaks to the satisfaction of classification society's representative.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 September 2004
Resolution: Duplicate requirement
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 26 July 2004
Resolved
The crew is using the steering flat as a storage for paint. According to the fire plan this area is not approved for paint storage. Remove the paint from area and stow in approved space to the satisfaction of the classification society's representative.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 September 2004
Resolution: Duplicate requirement
Fire Fighting › Self-contained Breathing Apparatus › Gauge
Issued 26 July 2004
Resolved
Repair/Replace all EEBD sight glasses as necessary.
Condition: Improper/Lack of Maintenance
Due 26 August 2004
Resolved 3 May 2006
Resolution: Observed proper EEBD sight glasses.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 26 July 2004
Resolved
Due to all other deficiencies noted and non-recording of maintenance or lack thereof, the validity of the safety management certificate is in question. Also, because of some on the crewmember's lack of knowledge, possible language barriers and non-responsive actions, the ship's master is required to arrange for an ISM audit to be conducted prior to the vessel's departure from San Francisco.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2004
Resolution: The ISM portion of the detention mentioned on form A and B dated 26JUL04 has been rectified.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 26 July 2004
Resolved
The printer for recording engineering failures, located in the control room is out of order. No action was taken by the crew to report failure until brought up by USCG personnel. Repair/Replace printer within seven working days.
Condition: Improper/Lack of Maintenance
Due 31 July 2004
Resolved 31 July 2004
Resolution: According to class report, a condition was imposed for the checked/replace of the UPS/battery back up. The Alarm printer should be repaired/replaced.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 July 2004
Resolved
Pending completion of U.S. Coast Guard expanded MARPOL examination vessel is to remain in port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2004
Resolution: ISM issues identified. Vessel detained until ISM audit is conducted.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 July 2004
Resolved
Verify proper operation of OWS discharge monitor to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2004
Resolution: Conditon of class issued.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 July 2004
Resolved
Repair/Replace soft patch on OWS discharge pipe to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Due 25 August 2004
Resolved 26 August 2004
Resolution: Condition of class issued.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 July 2004
Resolved
Remove holdbacks on all class A fire doors.
Due 25 August 2004
Resolved 26 August 2004
Resolution: All holdbacks removed.
Lifesaving › Lifeboat › Markings
Issued 25 July 2004
Resolved
Provide all required markings on exterior of lifeboats.
Due 25 August 2004
Resolved 26 August 2004
Resolution: All required markings on lifeboats provided.
Fire Fighting › Self-contained Breathing Apparatus › Gauge
Issued 25 July 2004
Resolved
Repair/Replace all EEBD sight glasses
Condition: Improper/Lack of Maintenance
Due 25 August 2004
Resolved 26 July 2004
Resolution: Same requirment issued twice.
Lifesaving
Issued 2 March 2000
Resolved
REPAIR/REPLACE INTERNAL LOWERING CABLE ON STARBOARD LIFEBOAT._x001C_ SOLAS 74 AMENDED CH. 3 REG. 48.1.4
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Lifesaving
Issued 2 March 2000
Resolved
REPAIR INOPERATIVE LIMIT SWITCHES ON STARBOARD LIFEBOAT DAVITS._x001C_ SOLAS 74 AMENDED CH. 3 REG. 48.2.5
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Navigation
Issued 2 March 2000
Resolved
ENSURE ALL PAINT IS REMOVED FROM STEERING GEAR ROOM AND STORED IN PROPER AREA. SOLAS 74 AMENDED CH 2-2 REG. 18.7
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Engineering
Issued 2 March 2000
Resolved
ENSURE OIL TRANSFER PROCEDURES ARE COMPLETED_x001C_ 33 CFR 155.720
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000