MAURY USCG vessel records Sign in
← All vessels

TB 278

TB 278 is a 1963 tank barge. The Coast Guard has recorded 17 inspections since 1984, most recently in May 2015, along with 28 deficiencies.

Records from 1984 to 2015. Most recent: inspection, 6 May 2015.

Built
1963
Last inspected
6 May 2015
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBK8497
Flag
UNITED STATES
367310180 (licence lapsed)
Maury page id
psix-44603

Inspections, by type

…with no type recorded5
Years with a record 8 calendar years (1984–2015)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)277.9 ft × 60.0 ft × 18.4 ft
Registered tonnagegross 2,996 / net 2,996
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · MERMENTAU, LA, UNITED STATES · built 1963
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 August 2026 · expires 30 September 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2996 - Regulatory (Subpart C or D), Gross Ton
2996 - Regulatory (Subpart C or D), Net Ton
5672 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBK8497MMSI 367310180 · cancelled · compulsorily equipped · granted 25 August 2007, cancelled 5 July 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SAGITTARIAN Towing Vessel · MISLE 165602 · 29 July 2004 · activity 2153768

Inspection history · 17

6 May 2015 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5118911
16 March 2015 Load Line/Change of Employment
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5085097
26 November 2014 Administrative Inspection · Load Line/Change of Employment
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5030330
29 July 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2153768
26 June 1992 Administrative
Administrative · Commandant (CG-INV-3) · Activity 957864
20 May 1992 Permit to Proceed
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1262371
28 December 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005609
19 November 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1333714
20 February 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1015274
9 December 1986 Administrative
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1330231
19 November 1986 Re-Inspection · Drydock Extension
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1329181
4 February 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1305371
6 December 1985 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 986489
19 November 1985 COI Inspection · MARPOL Annex I Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 994466
24 January 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 976951
4 January 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1284846
19 November 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 469672

Deficiency record · 28

Lifesaving
Issued 19 November 1986 Resolved
SERVICE THE LIFERAFT PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 November 1986 Resolved
PROPERLY INSTALL THE LIFERAFT PAINTER PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 November 1986 Resolved
PROVIDE LIGHTS FOR THE PFD'S PRIOR TO PLACING THE VESSEL IN SERVICE. (46 CFR 33.38-1)
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 November 1986 Resolved
RENEW THE BRACKETS ON THE RING BUOY PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 November 1986 Resolved
PROVIDE EXPOSURE SUITS PRIOR TO PLACING THE VESSEL IN SERVICE. (46 CFR 33.37-5)
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 19 November 1986 Resolved
DEMONSTRATE OPERATION OF ALL BILGE PUMPS PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 November 1986 Resolved
PROVIDE ON FIRE AXE PRIOR TO PLACING THE VESSEL IN SERVICE. (46 CFR 34.60-5)
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 November 1986 Resolved
PROVIDE EMERGENCY OUTFITS PRIOR TO PLACING THE VESSEL IN SERVICE. (46 CFR 35.30-20)
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 19 November 1986 Resolved
PROVIDE AND DEMONSTRATE THE PROPER OPERATION OF THE PORT RUNNING LIGHTS PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 19 November 1986 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE ANCHOR WINDLASS.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 19 November 1986 Resolved
PROVIDE NUTS AND BOLTS TO SECURE ALL HATCHES AND DEMONSTRATE THE WATERTIGHTINTEGRITY OF ALL FITTINGS PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 November 1986 Resolved
PROVIDE A GUARD FOR THE LISTER GENERATOR IN WAY OF THE HAND CRANK SHAFT PRIOR TO PLACING THE VESSEL IN SERVICE. (46 CFR 32.01-15)
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 19 November 1986 Resolved
TIGHTEN THE NUTS AND BOLTS FOR THE PUMPROOM LADDER STEPS AND RENEW WHERE NECESSARY PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 19 November 1986 Resolved
CONDUCT A HYDROSTATIC TEST OF ALL CARGO PIPING AND PORTABLE TRANSFER HOSE TO 1 1/2 MAWP PRIOR TO PLACING THE VESSEL IN SERVICE. (33 CFR 156.170(C)(4))
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 19 November 1986 Resolved
PROVIDE EVIDENCE OF RENEWAL OF THE CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Deck/Cargo
Issued 19 November 1986 Resolved
OPEN AND INSPECT ALL P/V VALVES PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 19 November 1986 Resolved
PROVIDE A COMBUSTIBLE GAS INDICATOR PRIOR TO PLACING THE VESSEL IN SERVICE.(46 CFR 35.30-15)
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 19 November 1986 Resolved
PROVIDE OILY WATER SEPARATOR, PIPELINE AND DISCHARGE CONNECTION FOR MACHINERY SPACE BILGES PRIOR TO PLACING THE VESSEL IN SERVICE. (33 CFR 157.39)
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 19 November 1986 Resolved
PROVIDE MANUFACTURER'S INSTRUCTION AND DATA FOR THE MARINE SANITATION DEVICE.
Condition: Unknown
Due 30 December 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 19 November 1985 Resolved
REPLACE OR CLEAN FLAME SCREENS ON ALL ULLAGE OPENINGS AS NECESSARY.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985 Resolved
CLEAN INTERIOR OF ALL P.V. VALVES AND INSTALL NEW SCREENS OR CLEAN AS NECESSARY.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Fire Fighting
Issued 19 November 1985 Resolved
CONDUCT FIVE YEAR HYDROSTATIC TEST AS REQUIRED BY 46 CFR 147.04-1(A)(2) ON CO2 CYLINDER 12792 LOCATED IN THE PUMPROOM, OR REPLACE WITH ACCEPTABLE BII EXTINGUISHER.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985 Resolved
DEMONSTRATE PROPER OPERATION AND SAFETY CONTROLS ON THE FOLLOWING: THERMAL FLUID HEATER, PUMP ENGINES AND REMOTE SHUTDOWNS, GENERATORS AND REMOTE SHUTDOWNS, AND PRESSURE VESSEL RELIEF VALVES. THIS REQUIREMENT MUST BE COMPLETED PRIOR TO CARRIAGE OF CARGO.
Condition: Unknown
Due 26 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 4 January 1985 Resolved
WIPE DOWN CARGO PUMP ROOM BILGE.
Condition: Unknown
Due 4 January 1985
Resolved 4 January 1985
Deck/Cargo
Issued 4 January 1985 Resolved
DEMONSTRATE SAFETY DEVICES AND OPERATING CONTROLS ON AUTOMATIC FLUID HEATER.
Condition: Unknown
Due 4 January 1985
Resolved 4 January 1985
Electrical
Issued 4 January 1985 Resolved
PROVIDE PROPER INSULATED HANDLE FOR DC VOLTAGE RHEOSTATE CONTROL.
Condition: Unknown
Due 4 January 1985
Resolved 4 January 1985
Electrical
Issued 4 January 1985 Resolved
INSTALL GRATING OR MATTING IN FRONT OF AC/DC MAIN SWITCHBOARD.
Condition: Unknown
Due 4 January 1985
Resolved 4 January 1985
Electrical
Issued 4 January 1985 Resolved
PROVIDE CIRCUIT INDEX CARD AT AC DISTRIBUTION PANEL CONTROL DOOR.
Condition: Unknown
Due 4 January 1985
Resolved 4 January 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.