Records from 1992 to 2026. Most recent: operational control imposed, 26 May 2026.
Inspection history · 33
26 May 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8380456
26 May 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8383763
23 October 2025
Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8257902
6 October 2025
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8230486
12 December 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8045751
13 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7911732
7 December 2023
Hull Examination · Drydock Exam · Deficiency Check · Internal Structural Exam · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7834753
1 November 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7816624
12 October 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7575936
21 March 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7416036
26 October 2021
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7340393
21 September 2020
Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7062690
12 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6559948
12 March 2018
Industry Initiated Exam · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6371013
20 December 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5788435
20 December 2015
Marine Casualty Follow Up
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5788457
9 September 2015
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5720665
6 November 2013
Deficiency Check · MTSA Verification · Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4748344
3 May 2013
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4586570
30 June 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4062814
21 March 2011
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3976248
14 September 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3849529
23 March 2010
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3701510
22 March 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2608555
2 March 2006
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2597213
26 January 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2281372
29 July 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2153768
4 May 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2059633
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978293
31 March 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1772289
24 December 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1726043
6 April 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 153420
11 August 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 23100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 May 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI notified by SCC-SF of the vessels loss of propulsion for starboard engine. Provide plans for repair to the satisfaction of MI prior to movement. 46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2026
Resolution: Operator replaced fuel lines in-kind, prevented future chafing. MI attended the vessel and attests to the operation dockside, deficiency rectified.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 6 October 2025
Resolved
Any towing vessel with alternating watches (shift work) or overnight accommodations must identify the duties and duty stations of each person onboard during an emergency. Station bill did not have all required emergency duties.
46 CFR 140.405(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 22 October 2025
Resolution: Completed repair.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 October 2025
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Life saving equipment on main deck berthing areas were improperly labeled.
46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 22 October 2025
Resolution: Completed repair.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 6 October 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. High water alarms for engine room were not labeled at the operating station.
46 CFR 143.230(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 22 October 2025
Resolution: Completed repair.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 6 October 2025
Resolved
The transfer procedures required by § 155.720 must contain, either in the order listed or by use of a cross-reference index page... Transfer procedures were not IAW with 33 CFR 155.750.
33 CFR 155.750
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 22 October 2025
Resolution: Completed repair.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 6 October 2025
Resolved
On a merchant vessel of the United States the construction of which began after March 4th, 1915..(5) each crew berthing area shall be equipped with information regarding-(A) vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and (B) procedures and resources to report crimes, including sexual assault and sexual harassment, including information-(i) on the telephone number, website address, and email address for reporting allegations of sexual assault and sexual harassment to the Coast Guard;(ii) on vessel owner or company procedures to report violations of company policy and access resources; (iii) on resources provided by outside organizations such as sexual assault hotlines and counseling;(iv) on the retention period for surveillance video recording after an incident of sexual harassment or sexual assault is reported; and (v) additional items specified in regulations issued by, and at the discretion of, the Secretary of the department in which the Coast Guard is operating. (d) In each washing space in a visible location there shall be information regarding procedures and resources to report crimes upon the vessel, including sexual assault and sexual harassment, and vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage. Vessel missing required signage in crew berthing areas.
46 U.S.C. 11011(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 22 October 2025
Resolution: Completed repair.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 December 2024
Resolved
A vessel at anchor... of less than 50 meters in length may exhibit an all-round white light where it can best be seen. Vessel's anchor light was inoperable. Repair to the satisfaction of the MI.
46 CFR 83.30 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2024
Resolved 19 December 2024
Resolution: Provided photo of operational light.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 December 2024
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Vessel's emergency lighting in the pilothouse was inoperable. Repair to the satisfaction of the MI.
46 CFR 143.410 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2024
Resolved 19 December 2024
Resolution: Provided photo of operational emergency lights.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 December 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical panel in machinery space was loose. Repair to the satisfaction of the MI.
46 CFR 143.400 (a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2024
Resolved 12 December 2024
Resolution: Electrical panel was screwed down.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 December 2024
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. 03 watertight doors were not labeled om both sides. Repaired in the presence of the marine inspector.
46 CFR 144.160 (e)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 December 2024
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. The equipment may be identified in words or with the appropriate symbol from IMO Resolution A.760(18). Vessel did not have accurate quantities labeled in the berthing areas. Repaired in the presence of the marine inspector.
46 CFR 141.340 (h)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 December 2024
Resolved
Each lifebuoy on a towing vessel must: Be marked in block capital letters with the name of the vessel. 01 lifebuoy onboard had faded markings. Repaired in the presence of the marine inspector.
46 CFR 141.360 (b)(4)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 May 2024
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage, including: Charts, including electronic charts acceptable to the Coast Guard, of appropriate scale to make safe navigation possible. The vessel had the recreational version of the Rose Point Navigation System on board instead of the commercial version.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 May 2024
Resolution: Verified correct version of Rose Point.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2024
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Have suitable propulsion controls to provide the operator full control at each operating station. The STBD main engine bridge shutdown was inoperable from the operating station.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 May 2024
Resolution: Verified operation of bridge shutdowns.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 13 May 2024
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. The line throwing appliance must have: (1) The equipment on the list provided by the manufacturer with the approved appliance; and (2) An auxiliary line that: (i) Is at least 450 meters (1,500 feet) long; (ii) Has a breaking strength of at least 40 kilonewtons (9,000 pounds-force) and (iii) Is, if synthetic, of a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light. The vessel had an incomplete line throwing appliance (1 of 4 required rocket units) and no auxiliary line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 10 July 2024
Resolution: Operator provided complete line throwing appliance.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 13 May 2024
Resolved
Every towing vessel equipped with an inflatable survival craft must have, in conspicuous places near each inflatable survival craft, approved placards or other posted instructions for launching and inflating inflatable survival craft. The vessel was missing posted life raft instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 29 May 2024
Resolution: Verified posted instructions.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 13 May 2024
Resolved
Any towing vessel with alternating watches (shift work) or overnight accommodations must identify the duties and
duty stations of each person onboard during an emergency
,including: (1) Responding to... flooding; (3) Launching
survival craft; (4) Taking action during heavy weather;
(6) Taking action relative to the tow; (7) Taking action
in the event of failure of propulsion, steering, or
control system. The emergency duties and duty stations
required by this section must be posted at each
operating station and in a conspicuous location in a
space commonly visited by crew members. The on board
station bill found was missing the referenced emergency
scenarios.
46 CFR 43.205 (b) & (c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 29 May 2024
Resolution: Verified updated emergency procedures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Damaged/leaking hydraulic line found under the bridge console.
46 CFR 43.205 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 29 May 2024
Resolution: Verified replaced hydraulic line.
10 - Safety of Navigation › N/A - No Subsystem › Type approval equipment
Issued 13 May 2024
Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. Inspection records found missing required information.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 29 May 2024
Resolution: Verified inspection records.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 13 May 2024
Resolved
The transfer procedures required by § 155.720 must contain, either in the order listed or by use of a cross-reference index page: (2) A description of each transfer system on the vessel including: (i) A line diagram of the vessel's transfer piping, including the location of each valve, pump, control device, vent, and overflow. Vessels transfer procedures found without description of transfer system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 29 May 2024
Resolution: Verified transfer procedures description.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 13 May 2024
Resolved
Each operator or agent of a vessel with a capacity of 250 or more barrels of fuel oil ... shall designate, either by name or by position in the crew, the person in charge (PIC) of each transfer to or from the vessel and of each tank-cleaning. No list of designated PIC’s was presented for review.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 17 May 2024
Resolution: PIC List provided dated 4/3/2024
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 13 May 2024
Resolved
The transfer procedures required by § 155.720 must be: (a) Available for inspection by the COTP or OCMI whenever the vessel is in operation; (c) Permanently posted or available at a place where the procedures can be easily seen and used by members of the crew when engaged in transfer operations. Inspectors were presented two different versions of transfer procedures, one printed and one electronic. Vessel to make single, correct version available for use by the crew.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 29 May 2024
Resolution: Verified transfer procedures.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2023
Resolved
A vessel that is exposed to salt water more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least twice every 5 years, with not more than 36 months between examinations. The vessel has not conducted a drydock and internal structural examination within the allotted time frame.
46 CFR 137.300(a)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2024
Resolution: Vessel completed drydock.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 October 2022
Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Both Port and Stbd fwd Fuel tanks have plastic tubular gauge. Replace plastic tubular gauge with glass tubular gauge (sight glass).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 28 October 2022
Resolution: Received photos of glass tubular gauge.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 October 2022
Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Bulkhead insulation in the fidley leading to the galley needs to be repaired or renewed to the satisfaction of the OCMI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 28 October 2022
Resolution: Received photo of insulation.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 12 October 2022
Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. The space above the accommodation space/below the operating stations needs to be labeled inside and outside to show exit.
46 CFR 144.160(f)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 28 October 2022
Resolution: Received photos of emergency exit signage.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 October 2022
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Install line throwing device on board vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 28 October 2022
Resolution: Received photo of line throwing device.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 October 2022
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Semi-portable fire extinguisher was removed from the vessel.
46 CFR 142.230(c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 October 2022
Resolved 13 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 October 2022
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Hydraulic hose fitting above the port MDE is leaking. Vessel's rep tightened loose fitting. Operational test satisfactory.
46 CFR 143.205(c)(1)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 28 October 2022
Resolved 13 October 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 October 2020
Resolved
Each watertight door and watertight hatch must be marked on both sides: "WATERTIGHT DOOR--KEEP CLOSED" or "WATERTIGHT HATCH--KEEP CLOSED." Vessel's watertight hatches missing required stenciling. 46 CFR 144.160(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 23 November 2020
Resolution: Verified properly affixed stickers marking watertight doors.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 October 2020
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists, with alarm provided for the day tank's low fuel level. Day tank alarm labeled for high fuel level instead of low fuel level. 46 CFR 143.230(a)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 23 November 2020
Resolution: Witnessed satisfactory audible and visual alarm for low fuel level in day tank.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2020
Resolved
Electrical systems must be designed and maintained to provide for safety of the persons onboard. Overhead lights discovered missing guards/globes in the following locations: Main deck head; Stbd aft area of the engineroom; PFD storage room, and; Upper deck bunkroom at the end of the passageway. 46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 23 November 2020
Resolution: Verified all light guards were properly affixed to light fixtures.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 October 2020
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vessel missing required FCC Bridge-to-Bridge Certificate. 47 CFR 80.1005
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 23 November 2020
Resolution: Verified satisfactory certificate on board vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2020
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Port and stbd air receivers in the engineroom contained painted over nameplates, making the MAWP and serial numbers unreadable. 46 CFR 143.300(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 23 November 2020
Resolution: Verified both port and stbd air receivers had legible nameplates, thus displaying required MAWP and serial numbers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2020
Resolved
Electrical panels or other enclosures containing more than one source of power must be fitted with a sign warning persons of this condition and identifying where to secure all sources. Main electrical panel in the engineroom missing required signage noting where to secure power sources. 46 CFR 143.250(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 23 November 2020
Resolution: Verified the proper signage posted IVO main electrical panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2020
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Noted numerous dead-end wires located under the pilothouse console. 46 CFR 143.400(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 23 November 2020
Resolution: Verified all dead-end wires under pilothouse console were properly capped.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 October 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 October 2021
Resolution: Verified errors were corrected for AIS unit.
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2010
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information, as required by 49 CFR 40.287.
Due 23 April 2010
Resolved 23 March 2010