Inspection history · 19
22 August 2025
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8215750
15 July 2025
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8186309
9 June 2025
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8155403
3 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7947871
23 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7899445
4 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7845041
28 July 2023
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7754674
17 July 2023
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7744544
17 July 2023
Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7746640
12 July 2022
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7503628
6 July 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7246528
12 June 2020
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6977540
31 March 2020
COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6933544
23 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6691361
11 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6660482
2 August 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6498615
11 April 2018
Deficiency Check · In-Service Inspection · Internal Structural Exam · Examination of Repairs · Re-Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6389639
19 September 2017
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6270263
8 May 2017
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6141166
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 June 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 15 July 2025
Resolution: The owner presented the FCC Radio Station Authorization dated 04-04-2017. The deficiency is cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2025
Resolved
The vessel's portable fire extinguishers are past due for their required Annual inspection. The owner shall ensure the appropriate inspections are conducted within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 15 July 2025
Resolution: The owner provided proof of fire extinguisher inspections by qualified servicing agency. The deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2025
Resolved
Your chemical testing program is not in compliance with 46CFR Parts 4 and 16. You must provide the attending Marine Inspector proof of enrollment into an approved drug consortium within 30 days or cease operations.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 22 August 2025
Resolution: The owner provided copies of the new contract with the testing facility used to meet the requirements of 46CFR Parts 4 and 16.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 June 2025
Resolved
Seven (07) Type-I personal floatation devices were found to be unserviceable and were removed from the vessel. Your passenger count will be reduced until sufficient, serviceable PFDs are installed on the boat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 June 2025
Resolved 12 June 2025
Resolution: The owner replaced the damaged PFDs and the deficency was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 June 2025
Resolved
The battery on the Life Float's Float Light is spent and will not illuminate the light. The battery was replaced and the deficiency was cleared.
Action required: 10 - Deficiency Rectified
Due 12 June 2025
Resolved 12 June 2025
Resolution: The battery was replaced and the deficiency was cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 January 2024
Resolved
A vessel operated in freshwater must undergo a drydock examination and internal structural examination at least once every five years. The HOLIDAY, received an extension to complete their required drydock exam by January 2nd, 2024. Since that date has passed, the vessel must complete the required exams prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2024
Resolved 3 July 2024
Resolution: An inspection was conducted aboard the vessel finding it in satisfactory condition to conduct operations within the limits of their Certificate of Inspection. The deficiency is cleared.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 17 July 2023
Resolved
Small passenger vessels are required to have an alarm system that will indicate if a space has high water level that alarms at the operating station. The crew must make hourly rounds (while underway) to ensure the lazarrett is not taking on water until the unit is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2023
Resolved 28 July 2023
Resolution: Satisfactory test of the high water alarm was conducted, and the deficiency is cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 July 2023
Resolved
A vessel not exposed to salt water must undergo a drydock examination and an internal structural examination at least once every five years. The vessel is past due for these examinations since 30 JUN 2023. Complete the examinations or get an extension prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2023
Resolved 19 July 2023
Resolution: Vessel received Dry Dock extension. Vessel is to be pulled out for DD no later than 02JAN2024.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 July 2023
Resolved
A vessel must undergo an Annual Inspection within 3 months before or after each anniversary date. The vessel is past due for its Annual Inspection as of 13JUL2023. Complete the inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2023
Resolved 17 July 2023
Resolution: A successful Annual Inspection was completed on this vessel today. The deficiency is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 July 2021
Resolved
Refresh retro-reflective tape and name on Life Floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2021
Resolved 11 August 2021
Resolution: The name and retro-reflective tape have been refreshed and the deficiency was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 July 2021
Resolved
Replace batteries on Float Light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2021
Resolved 11 August 2021
Resolution: Float Light batteries were replaced and the deficiency is cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 July 2021
Resolved
Have CO2 fire extinguishers inspected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2021
Resolved 28 July 2021
Resolution: Extinguishers weighed and inspected satisfactorily. Deficiency cleared.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 March 2020
Resolved
High water alarm in the lazzarrette is inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2020
Resolved 12 June 2020
Resolution: High water alarm tested satisfactorily, deficiency is cleared.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 March 2020
Resolved
Stern light is inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2020
Resolved 12 June 2020
Resolution: Stern light functions properly, deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 March 2020
Resolved
Exhaust leak noted in the lazzarrette. There is a hole in the starboard exhaust pipe that must be sealed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2020
Resolved 12 June 2020
Resolution: Exhaust leak was sealed to the satisfaction of the attending marine inspector. Deficiency is cleared
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 11 April 2019
Resolved
Prove proper operation of fire pump prior to carrying passengers. Hose and clamps need to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2019
Resolved 23 May 2019
Resolution: Fire pump was tested and ran properly. Deficiency is cleared.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2019
Resolved
Prove proper operation of high water alarm bilge sensor, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2019
Resolved 23 May 2019
Resolution: High water level indicator, and alarm were tested and functioned properly. Deficiency is cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 August 2018
Resolved
COD lapsed. Owner fell ill and this administrative issue was missed by new manager.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 9 August 2018
Resolution: COD renewed and enroute to the vessel. Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2018
Resolved
Operator must produce proof of recent drug testing of crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 27 September 2018
Resolution: Owner produced records for current testing of the crew. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 August 2018
Resolved
Record of required drill is not on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2018
Resolved 27 September 2018
Resolution: Record of drill is now on-board. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 August 2018
Resolved
Float lights on life floats need new batteries.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 2 August 2018
Resolved 9 August 2018
Resolution: New batteries installed and test sat. Deficiency cleared.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 September 2017
Resolved
Crop and renew wasted area on bulkhead between holds #4 and #5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2017
Resolution: Bulkhead between holds #4 & #5 has been renewed. Visual and dye pennetrant tests were sat. Deficiency is cleared.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 September 2017
Resolved
Replace wasted portion of pipe on generator exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2017
Resolution: Exhaust piping was renewed and deficiency is cleared.
Engineering › Steering Gear System › Rudder
Issued 19 September 2017
Resolved
Replace wasted support brackets on rudder post.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2017
Resolution: Rudder posts were renewed and the deficiency is cleared.
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 September 2017
Resolved
Crop and renew longitudinal bracket on port side of centerline in #5 hold.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2017
Resolution: Wasted section of longitudinal deck bracket has been renewed and the deficiency cleared.
Construction/Loadline › Structures › Ventilators
Issued 19 September 2017
Resolved
Crop and renew wasted area in vicinity of air vent on starboard side in #5 hold.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2017
Resolution: Wasted area in vicinity of stbd vent has been renewed and the deficiency cleared.
Engineering › Bilge Water Management System › Strainer
Issued 19 September 2017
Resolved
Install strainers onto bilge suction lines and prove proper operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2018
Resolution: Proper strainers are in place. Deficiency cleared.
Construction/Loadline › Hull › Hull Plating
Issued 19 September 2017
Resolved
Crop and renew wasted areas of hull plating as identified by USCG Marine Inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2018
Resolved 24 July 2018
Resolution: Hull repairs completed to the satisfaction of marine inspectors.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 May 2017
Resolved
Complete dry dock examination or get extension granted by [name withheld] 176.675.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2017
Resolved 9 May 2017
Resolution: Extension granted for dry dock examination by Sector Buffalo until 9/30/2017.