MAURY USCG vessel records
← All vessels

CARNIVAL SUNSHINE

CARNIVAL SUNSHINE is a 1996 passenger vessel (inspected). The Coast Guard has recorded 93 inspections since 2016, most recently in June 2026, along with 52 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 18 June 2026.

Built
1996
Last inspected
18 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 June 2026
…with no type recorded45
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9070058
448228
Flag
BAHAMAS, THE
Maury page id
psix-448228

Documentation record

Tonnage as PSIX records it10772 - Dead Weight, Ton
53800 - Displacement, Ton
103881 - Convention (Subpart B), Gross Ton
86042 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CARNIVAL PARADISE Passenger (Inspected) · MISLE 483759 · 12 January 2022 · activity 7426615

Inspection history · 93

18 June 2026 COC-CVE Quarterly · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8405056
1 March 2026 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8318079
1 March 2026 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8327528
7 December 2025 PSC B · COC-CVE Annual
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8273729
16 September 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8259846
22 July 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8192047
8 July 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8183155
8 June 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8149825
10 February 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8078111
4 February 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8074705
12 December 2024 PSC A · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8046010
23 November 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8040647
13 June 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7932063
8 April 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7892025
25 February 2024 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7869945
14 December 2023 PSC A · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7831416
2 November 2023 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7819670
24 September 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7802535
31 August 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7781735
8 July 2023 In-Service Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7736584
15 June 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7712847
1 June 2023 PSC B · COC-CVE Quarterly
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7706927
6 February 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7632786
26 December 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7613206
15 December 2022 PSC A · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7582743
1 December 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7603064
25 September 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7567928
11 August 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7531510
10 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7529723
6 August 2022 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7529903
20 June 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7484140
16 June 2022 COC-CVE Quarterly · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7478300
27 January 2022 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7387088
16 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7381056
12 January 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7426615
17 December 2021 In-Service Inspection · Administrative Inspection · Ballast Water Examination · PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7367984
3 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935049
10 October 2019 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6819591
18 July 2019 ISPS III Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6753844
5 May 2019 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6677264
27 April 2019 Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6668484
27 April 2019 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6797355
6 April 2019 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6658019
23 February 2019 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6789294
10 February 2019 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6630493
3 February 2019 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6655155
30 December 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6788008
28 October 2018 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6568962
25 October 2018 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6573573
18 August 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6582232
18 August 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6588404
15 July 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6610940
3 June 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6582066
18 May 2018 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6418052
27 April 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6400724
26 April 2018 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6399705
20 January 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6342989
30 October 2017 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6295078
20 October 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6306820
24 September 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6277053
7 July 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6201262
20 June 2017 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6180624
8 May 2017 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6141292
6 May 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6375968
28 April 2017 Administrative Inspection · COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6132514
28 April 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6270285
23 April 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6299538
25 March 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6277393
25 March 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6282676
27 February 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6101851
24 February 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6167525
3 February 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6148380
26 December 2016 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6062373
18 December 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6144567
18 December 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6147583
22 November 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6060403
28 October 2016 COC-CVE Initial · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6031378
12 October 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6026441
9 October 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6021501
3 October 2016 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6015144
19 September 2016 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6003988
14 September 2016 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6002355
5 September 2016 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5993330
28 July 2016 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5955558
23 July 2016 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5952126
21 June 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5914532
3 June 2016 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5896039
25 May 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5886553
11 May 2016 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5874258
10 May 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5873343
6 May 2016 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5870336
29 April 2016 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5863777
24 April 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5913496

Deficiency record · 52

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 June 2026 Resolved
It shall be possible for each door to be opened and closed from each side of the bulkhead by one person only. PSCO observed A-60 fire door to galley on deck 8 unable to close. 74 SOLAS 97 II-2/30.3
Action required: 10 - Deficiency Rectified
Resolved 18 June 2026
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 18 June 2026 Resolved
Where in a passenger ship it is necessary that a ventilation duct passes through the main vertical zone division, a fail safe automatic closing fire damper shall be fitted adjacent to the division. The damper shall also be capable of being manually closed from each side of the division. The operating position shall be readily accessible and be marked in red light reflecting color. PSCO observed damper lights inoperable on F.D. 30B29, F.D. 3D(29 and F.D. 30830. 74 SOLAS 97 II-2/16.8
Action required: 10 - Deficiency Rectified
Resolved 18 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 December 2025 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40s and no less than 10s. Double leaf door A8.14 in a stairway enclosure did not latch upon closure. 74SOLAS(97)II-2/30.4.1 10c
Action required: 10 - Deficiency Rectified
Resolved 7 December 2025
Resolution: Crew repaired sequencing bar to allow for proper closure. PSCO witnessed successful test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 December 2025 Resolved
Not less than on half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights, not less than two of these shall also be provided with lifebuoy self-activating smoke signals and be capable of quick release from the navigation bridge. Two lifebuoys had inoperable self igniting lights. 74SOLAS(97)III/7.1.3 10c
Action required: 10 - Deficiency Rectified
Resolved 7 December 2025
Resolution: Crew replaced 02 self igniting lights on lifebuoys.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 7 December 2025 Resolved
Every crew member with assigned emergency duties shall be familiar with there duties before the voyage begins. Crew member on lifeboat #25 did not know how to operate emergency steering system. 74SOLAS(20)III/19.2.1 10c
Action required: 10 - Deficiency Rectified
Resolved 7 December 2025
Resolution: Crew member was trained on proper emergency steering operation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 December 2025 Resolved
In passenger ships units shall give an indication of any fire and its location in any space served by the system and shall be centralized on the nav bridge or in the main fire control station. Detector B0903 was inop. Corrected on the spot. 74SOLAS(97)II-2/12.1.2.1 10c
Action required: 10 - Deficiency Rectified
Resolved 7 December 2025
Resolution: Crew member replaced broken detector. Tested satisfactorily.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 June 2025 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. Fire fighting team had set-up hose along the door edge prior to charging rather than through the provided hose port. The hose burst open when it was charged causing a major safety issue and demonstrated a lack of proficiency with hose handling. The crew demonstrated satisfactory proficiency on second drill attempt. 74 SOLAS 20 II-2/15.2.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2025
Resolution: The crew demonstrated satisfactory proficiency on the second drill attempt. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 June 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The remote winch release cable for the #1 lifeboat/rescue boat had a seized pulley preventing it from automatically paying out as the boat was lowered. 74 SOLAS 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2025
Resolution: Crew lubricated and acuated pulley. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2025 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances shall be clearly marked with approval information including the Administration which approved it, and any operational restrictions. Numerous lifejackets in the lifeboat storage bins have faded approval and operation restrictions are no longer readable due to fading. 74 SOLAS 20 III/34 LSA Code 1.2.2.9; 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2025
Resolved 22 July 2025
Resolution: Lifejackets in lifeboat storage bins examined and now found faded ones replaced with new approved Jackets. Lifejackets now considered satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2025 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances shall be fitted with retro-reflective material where it will assist in detection. Throughout lifeboat lifejacket storage areas, numerous lifejackets had retroreflective tape missing or faded. 74 SOLAS 20 III/34 LSA Code 1.2.2.7; 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2025
Resolved 22 July 2025
Resolution: Lifejackets throughout storage areas with missing or faded retro-reflective tape examined and now found replaced with new approved lifejackets. Lifejackets now considered satisfactory.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 June 2025 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Fire screen door (location numbers: 3.301, 3.073, 4.007B) did not close and secure as designed. 74 SOLAS 20 II-2/14.1.1
Action required: 10 - Deficiency Rectified
Resolved 8 June 2025
Resolution: Crew made adjustments to doors for them to close completely and latch.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 June 2025 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. The fire fighting hose on Deck Zero near the Liquor Room was punctured during the fire drill. 74 SOLAS 20 II-2/14.1.1
Action required: 10 - Deficiency Rectified
Resolved 8 June 2025
Resolution: Crew replaced hose with a spare.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 June 2025 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. The following fire doors did not close due to worn gasket material, or they need adjustment to the latch or closing mechanism: FSD C13, FSD C017, FSD PM005. 74 SOLAS 97 II-2/30.4.1
Action required: 10 - Deficiency Rectified
Resolved 8 June 2025
Resolution: Crew made adjustments to doors for them to close completely and latch.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2024 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures local power accumulators for power-operated doors shall be provided in the immediate vicinity of the doors to enable the doors to be operated at least 10 times (fully opened and closed) using the local controls. F.S.D. 5.36 did not open upon local operation. 74 SOLAS 97 II-2/30.4.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2024 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. F.S.D. #4.008A, #1.47, #1.009 did not close upon local operation. 74 SOLAS 97 II-2/30.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 December 2024 Resolved
Any required automatic sprinkler, fire detection, and fire alarm system shall be capable of immediate operation at all times. Two smoke detectors in main galley found inoperable, one in chef's office and one labeled B0259. 74 SOLAS 97 II-2/12.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 December 2024 Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. F&B Manager's Office is a "room-in-room" configuration within the Deck 3 main galley. The only means of escape from the office is into the galley. There is a window that looks into an adjacent office but does not give an adequate view of the galley. The office has no means of immediate and clear notification of fire in the surrounding space. 74 SOLAS 97 II-2/28.1.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 4 February 2025
Resolution: Windows of Chef Office to the galley and between the Assistant F&B Manager office and Chef Office were cleared to provide a better view to the surrounded spaces forward.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 June 2024 Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. Secondary escape from "The Circle C" lounge was stuck in a closed position and unable to be opened as designed as an emergency exit. 74 SOLAS 97 II-2/28.1.2
Action required: 10 - Deficiency Rectified
Resolved 13 June 2024
Resolution: Deficiency rectified
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 December 2023 Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed. FSDs 0.80 abd 0.90 in the garbage room did not latch. 74 SOLAS 97 II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: Crew replaced latches on doors so that they closed securely.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 14 December 2023 Resolved
MUster and embarkation stations shall be adequately illiminated by lighting supplied from the emergency source of electrical power required by regilation II-I/42 or II-I/43. Two embarkation lights on the starboard side aft of the MES are nonoperational. 74 SOLAS 97 III/11.4
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: Crew replaced lights and made operational.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 December 2023 Resolved
Spaces are classified IAW their fire resk as shown in categories 1-14. Stairs 240 and 200 are category 2 spaces, where storage of combustibles is prohibited. PSCO observed combustible materials stored in stairs 240 and 200. 74 SOLAS 97 II-2/26.2.2
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: Crew removed stored materials from stairways 200 & 240.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 December 2023 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall have an approximately uniform rate of closure of no more than 40 seconds and no less than 10 seconds. FSDs A.03, A.09, B.15, 1.07, 2.29, 4.017 and door in way of a provision room did not securely close within the proper time frame.
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: Crew adjusted rate of closure.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 June 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Stairwell guides on Decks 4, 5, and 7 of the mid stairwell, Food Prep Room 24 on Deck 0, and Main Laundry on Deck A crews were unfamiliar with ships emergency procedures. 16ac, 74 SOLAS 20 III/19.2.1.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 20 June 2023
Resolution: Vessel provided class statement attesting to recitification of deficiencies.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 June 2023 Resolved
A door designed to re-open upon contacting an object in its path shall re-open sufficiently to allow a clear passage of at least 0.75m but no more than 1m. PSCO witnessed FSD 4.069 continue to close with contact bar pressed. 50ac, 74 SOLAS 97 II-2/30.4.2.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 20 June 2023
Resolution: Vessel provided class statement attesting to recitification of deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 June 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed davit brake on #2 Lifeboat/Rescue Boat was sticking during operation. 50ac, 74 SOLAS 20 III/20.2.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 20 June 2023
Resolution: Vessel provided class statement attesting to recitification of deficiencies.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 June 2023 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing. FSDs 10.001D, 4.014, 1.18, 1.17, A.72, and C.01 did not close. 10c, 74 SOLAS 97 II-2/30.4.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2023
Resolution: Deficiency Rectified
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 June 2023 Resolved
The number and position of hydrants shall be such that at least two jets of water not emanating from the same hydrant, one of which shall be from a single length of hose, may reach any part of the ship normally accessible to the passengers or crew while the ship is being navigated. Fire Station 6.19 on Deck 6 was unable to be opened, rendering the fire station inoperational and not allowing for two jets. 10c, 74 SOLAS 97 II-2/4.5.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2023
Resolution: Deficiency Rectified
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 December 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue Boat #1 rudder was unable to turn to port. 74 SOLA 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2022 Resolved
Means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be photoluminescent material or marked by lighting. 74 SOLAS 01 II-2/41-2.4.7
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Rectified.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 December 2022 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Crew members assigned to lifeboats 17, 21, and 25 were not familiar with locations of lifeboat equipment or arrangments for emergency steering nor emergency bilge pumping. 74 SOLAS 20 II/19.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Recitified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2022 Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to stairway forming a vertical escape. Galley workshop in Deck 3 galley stbd side has only one means of escape, and no means to notify crew inside in case of fire in galley. 74 SOLAS 97 II-2/28.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2022
Resolved 6 February 2023
Resolution: Vessel provided class report. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 December 2022 Resolved
All openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed FD 0.086 in Recycling Room, not able to be closed due to storage of waste bags. 74 SOLAS 97 II-2/30.1
Action required: 10 - Deficiency Rectified
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Rectified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2022 Resolved
Escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting, Lighted escape sign in Sunshine Restaurant, Deck 3 aft stbd side was not lit. 74 SOLAS 01 II-2/41-2.4.7
Action required: 10 - Deficiency Rectified
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 December 2022 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed fire door 0.089 with broken latch, unable to be closed. 74 SOLAS II-2/30.1
Action required: 10 - Deficiency Rectified
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Rectified.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 16 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. Multiple alarm indicators were not functioning in the engine room. (Cite: 74 SOLAS 20 I/11)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 28 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 June 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. On multiple life boats, the outside hand rails were loose or unsecured. (Cite: 74 SOLAS 20 III/20.2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 28 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2022 Resolved
Internal combustion engines of a cylinder diameter of 200 mm or a crankcase volume of 0.6m3 and above shall be provided with crankcase explosion relief valves of a suitable type with sufficient relief area. Crankcase explosion relief valves were painted. (Cite: SOLAS 2004 II-I/27.4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 30 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
01 - Certificates & Documentation › 013 - Documents › Certificate or documentary evidence of financial security relating to shipowners liability
Issued 16 June 2022 Resolved
A copy of the documentation, as approved by the Administration indicating that the alternative design and arrangements comply with this regulation, shall be carried on board the ship. Vessel missing document indicating the approved alternative design. (Cite: SOLAS III/38.4.2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 28 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 June 2022 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. Crew could not provide training records of the individual doing inspections on the life raft. (Cite: 74 SOLAS 97 III/20.3.1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 30 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 June 2022 Resolved
All openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Fire door F.S.D.B.01 was damaged and did not meet fire resistance standards. (Cite: 74 SOLAS 01 II-2/30.1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 30 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 16 June 2022 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All the first aid kits in the life boats were not stowed in accordance with manufacturer recommendations. First aid kits should be stored in less than 25 degrees Celsius. (Cite:74 SOLAS 20 III/34)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2022
Resolved 10 August 2022
Resolution: RECEIVED ORDER COMFORMATION FOR NEW FIRST AID KIT
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 June 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. #1 life boat, which is also a rescue boat, steering was not in proper working order. (Cite: 74 SOLAS 20 III/20.2)
Action required: 10 - Deficiency Rectified
Due 16 June 2022
Resolved 16 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 June 2022 Resolved
Operational readiness, maintenance and inspections. Sight window for the locking bolt and safety pin, and the self-inspection window on the MES were painted over or unable to see through (Cite: 74 SOLAS 20 III/20.3)
Action required: 10 - Deficiency Rectified
Due 16 June 2022
Resolved 16 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 December 2021 Resolved
Openings in "A" class divisions. Fire doors in main vertical zone bulkheads and stairway enclosures shall satisfy the following requirements. Double-leaf doors equipped with a latch necessary to their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system... Various double-leaf doors had inoperable sequencing bars. SOLAS 97 II-2/30.4.5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 27 December 2021
Resolution: Received Class Report noting all doors have been repaired and/or adjusted as appropriate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 17 December 2021 Resolved
The Administration may require that all responsible and practicable measures shall be taken to limit the entry and spread of water above the bulkhead deck...PSCOs identified missing gasket and broken securing device on aft mooring deck station vent. SOLAS 97 II-1/20.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 December 2021 Resolved
Openings in "A" class divisions. It shall be possible for each door to be opened from each side of the bulkhead by one person only... Sliding FSD 1.47 did not close on local activation. SOLAS 97 II-2/30.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 December 2021 Resolved
Means of escape. Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces...PSCOs found blocked or broken emergency escape doors in the Piano Bar and Kid's Club. SOLAS II-2/28
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 December 2021 Resolved
For determining the appropriate fire integrity standards to be applied... such spaces are classified according to their fire risk as shown in categories 1 to 14... Various spaces; to include but not limited to: the machinery space, upper deck AC rooms, I95 corridor, and deck 3 port side FWD, are being improperly used for storage; not meeting the fire integrity requirements of the designed space. SOLAS 97 II-2/26.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 19 December 2021
Resolution: Class provided report dated 19DEC21 that items were removed/relocated and def rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 December 2021 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material...stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed...PSCOs observed excessive wastage on the aft mooring deck door and missing gasket, door in no longer weathertight. ICLL Annex I/12
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 December 2021 Resolved
Openings in "A" class divisions. Fire doors in main vertical zone bulkheads and stairway enclosures shall satisfy the following requirements...the doors shall be self-closing and have an approximately uniform rate of closure of no more than 40s and no less than 10s with the ship in the upright position...Multiple fire doors throughout the vessel slammed erratically in 5s or less. SOLAS 97 II-2/30.4.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2022
Resolved 27 December 2021
Resolution: Received Class Report noting all doors have repaired/adjusted accordingly.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 29 April 2016 Resolved
0750 - Fire fighting appliances - Construction of doors and door frames in "A" class divisions shall provide resistance to passage of smoke and flame equivalent to the bulkhead in which situated. 02 open bolt holes were found in the frame above FSD A. 71 as well as 02 bolt holes found in the frame above FSD A.66. (Doors to carpenter shop and upholstery shop).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2016
Resolved 11 May 2016
Resolution: Class inspected and approved repairs.
Engineering › Feedwater/Condensate Water System › Piping
Issued 29 April 2016 Resolved
0330 - Accommodation - Piping systems shall be of a design adequate for service for which intended. A black water line located in stairwell 16, betwen decks 0 and 1, was found to have temporary soft patch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2016
Resolved 11 May 2016
Resolution: Class inspected and approved repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.