Records from 1996 to 2026. Most recent: inspection, 18 June 2026.
Inspection history · 211
18 June 2026
COC-CVE Quarterly · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8405056
1 March 2026
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8318079
1 March 2026
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8327528
7 December 2025
PSC B · COC-CVE Annual
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8273729
16 September 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8259846
22 July 2025
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8192047
8 July 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8183155
8 June 2025
COC-CVE Quarterly · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8149825
10 February 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8078111
4 February 2025
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8074705
12 December 2024
PSC A · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8046010
23 November 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8040647
13 June 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7932063
8 April 2024
In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7892025
25 February 2024
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7869945
14 December 2023
PSC A · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7831416
2 November 2023
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7819670
24 September 2023
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7802535
31 August 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7781735
8 July 2023
In-Service Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7736584
15 June 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7712847
1 June 2023
PSC B · COC-CVE Quarterly
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7706927
6 February 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7632786
26 December 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7613206
15 December 2022
PSC A · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7582743
1 December 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7603064
25 September 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7567928
11 August 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7531510
10 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7529723
6 August 2022
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7529903
20 June 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7484140
16 June 2022
COC-CVE Quarterly · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7478300
27 January 2022
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7387088
16 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7381056
12 January 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7426615
17 December 2021
In-Service Inspection · Administrative Inspection · Ballast Water Examination · PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7367984
3 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935049
10 October 2019
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6819591
18 July 2019
ISPS III Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6753844
5 May 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6677264
27 April 2019
Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6668484
27 April 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6797355
6 April 2019
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6658019
23 February 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6789294
10 February 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6630493
3 February 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6655155
30 December 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6788008
28 October 2018
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6568962
25 October 2018
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6573573
18 August 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6582232
18 August 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6588404
15 July 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6610940
3 June 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6582066
18 May 2018
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6418052
27 April 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6400724
26 April 2018
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6399705
20 January 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6342989
30 October 2017
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6295078
20 October 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6306820
24 September 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6277053
7 July 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6201262
20 June 2017
Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6180624
8 May 2017
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6141292
6 May 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6375968
28 April 2017
Administrative Inspection · COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6132514
28 April 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6270285
23 April 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6299538
25 March 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6277393
25 March 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6282676
27 February 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6101851
24 February 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6167525
3 February 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6148380
26 December 2016
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6062373
18 December 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6144567
18 December 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6147583
22 November 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6060403
28 October 2016
COC-CVE Initial · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6031378
12 October 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6026441
9 October 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6021501
3 October 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6015144
19 September 2016
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6003988
14 September 2016
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6002355
5 September 2016
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5993330
28 July 2016
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5955558
23 July 2016
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5952126
21 June 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5914532
3 June 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5896039
25 May 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5886553
11 May 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5874258
10 May 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5873343
6 May 2016
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5870336
29 April 2016
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5863777
24 April 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5913496
14 December 2015
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5781295
1 December 2015
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5772838
6 November 2015
COC-CVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5758751
18 October 2015
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6141295
29 August 2015
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5720297
16 August 2015
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5221602
27 May 2014
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4870455
17 May 2014
ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4859993
27 March 2014
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4823779
17 March 2014
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4817721
21 June 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4351177
16 June 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4347519
28 May 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4328675
16 February 2012
ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4245394
3 February 2012
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4239851
7 January 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4224146
5 January 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4240562
29 December 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4218301
3 December 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4202026
10 September 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4142832
18 August 2011
ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4117138
17 August 2011
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4188407
19 July 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4087067
17 February 2011
COC-CVE Quarterly · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3947431
17 January 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3932693
10 January 2011
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3924267
23 October 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3875843
23 October 2010
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3876170
22 October 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3880467
27 February 2010
COC-CVE Quarterly · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3686529
21 January 2010
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3667465
9 May 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3479041
9 March 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3434061
5 March 2009
COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3426796
6 October 2008
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3339620
3 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3337853
2 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3339431
2 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3381235
21 September 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3329178
24 August 2008
MARPOL Annex V Examination · COC-CVE Annual · Ballast Water Examination · STCW 95 Exam · ISPS II Exam · ILO-147 Exam · Loadline Exam · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3307040
29 June 2008
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3251387
30 May 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3228853
24 February 2008
MARPOL Annex I Examination · ILO-147 Exam · COC-CVE Quarterly · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3152525
21 February 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3151782
28 January 2008
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3141741
1 November 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3093222
3 June 2007
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2950130
26 May 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2940782
14 May 2007
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2932719
14 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2932812
25 February 2007
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2877138
19 February 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2875066
29 October 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2817739
27 August 2006
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2760786
26 August 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2760159
24 July 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2722921
21 June 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2688978
26 February 2006
COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2592089
4 December 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2546110
12 September 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2492204
2 September 2005
ISPS II Exam · MARPOL Annex I Examination · COC-CVE Annual · MARPOL Annex V Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2481926
20 August 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2479259
21 May 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2377043
12 May 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2371565
22 March 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2317231
27 February 2005
MARPOL Annex V Examination · Ballast Water Examination · COC-CVE Quarterly · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2300005
29 January 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2282851
22 December 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2263426
24 October 2004
Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2227160
23 August 2004
COC-CVE Annual · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2173890
3 June 2004
ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2087524
29 February 2004
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2015176
3 October 2003
Administrative Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1920610
2 March 2003
MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1751198
1 September 2002
Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1658071
10 June 2002
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1628824
7 April 2002
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1602567
7 October 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 441636
7 October 2001
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1440569
12 August 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 498088
8 July 2001
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1472478
8 April 2001
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1452784
14 January 2001
MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1443124
8 October 2000
Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405059
31 August 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 473082
15 July 2000
Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384510
22 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 514326
21 May 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 52577
16 April 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1404951
15 February 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1499
30 January 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 815287
5 January 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 816137
10 October 1999
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1453675
18 August 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 779449
8 August 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1381657
21 July 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1103927
11 July 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1381630
5 July 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 98835
18 April 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790002
2 March 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 798893
28 February 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 451712
24 January 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1365011
11 October 1998
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 801903
12 July 1998
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1129591
5 July 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1128596
27 May 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1126477
3 May 1998
MARPOL Annex V Examination · Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1364743
11 January 1998
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1364517
9 December 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 779439
12 October 1997
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1364405
4 September 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1121282
20 July 1997
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 780199
20 April 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1097978
20 April 1997
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106310
19 January 1997
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1363923
14 November 1996
Control Verification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 861261
18 October 1996
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 870838
7 October 1996
Type not recorded
No type recorded · Activities Europe · Activity 1359271
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 June 2026
Resolved
It shall be possible for each door to be opened and closed from each side of the bulkhead by one person only. PSCO observed A-60 fire door to galley on deck 8 unable to close.
74 SOLAS 97 II-2/30.3
Action required: 10 - Deficiency Rectified
Resolved 18 June 2026
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 18 June 2026
Resolved
Where in a passenger ship it is necessary that a ventilation duct passes through the main vertical zone division, a fail safe automatic closing fire damper shall be fitted adjacent to the division. The damper shall also be capable of being manually closed from each side of the division. The operating position shall be readily accessible and be marked in red light reflecting color. PSCO observed damper lights inoperable on F.D. 30B29, F.D. 3D(29 and F.D. 30830.
74 SOLAS 97 II-2/16.8
Action required: 10 - Deficiency Rectified
Resolved 18 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 December 2025
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40s and no less than 10s. Double leaf door A8.14 in a stairway enclosure did not latch upon closure.
74SOLAS(97)II-2/30.4.1 10c
Action required: 10 - Deficiency Rectified
Resolved 7 December 2025
Resolution: Crew repaired sequencing bar to allow for proper closure. PSCO witnessed successful test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 December 2025
Resolved
Not less than on half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights, not less than two of these shall also be provided with lifebuoy self-activating smoke signals and be capable of quick release from the navigation bridge. Two lifebuoys had inoperable self igniting lights.
74SOLAS(97)III/7.1.3 10c
Action required: 10 - Deficiency Rectified
Resolved 7 December 2025
Resolution: Crew replaced 02 self igniting lights on lifebuoys.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 7 December 2025
Resolved
Every crew member with assigned emergency duties shall be familiar with there duties before the voyage begins. Crew member on lifeboat #25 did not know how to operate emergency steering system.
74SOLAS(20)III/19.2.1 10c
Action required: 10 - Deficiency Rectified
Resolved 7 December 2025
Resolution: Crew member was trained on proper emergency steering operation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 December 2025
Resolved
In passenger ships units shall give an indication of any fire and its location in any space served by the system and shall be centralized on the nav bridge or in the main fire control station. Detector B0903 was inop. Corrected on the spot.
74SOLAS(97)II-2/12.1.2.1 10c
Action required: 10 - Deficiency Rectified
Resolved 7 December 2025
Resolution: Crew member replaced broken detector. Tested satisfactorily.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 June 2025
Resolved
Crew members shall be trained to be familiar with the
arrangements of the ship as well as the location and
operation of any fire-fighting systems and appliances that
they may be called upon to use. Fire fighting team had set-up
hose along the door edge prior to charging rather than
through the provided hose port. The hose burst open when it
was charged causing a major safety issue and
demonstrated a lack of proficiency with hose handling. The
crew demonstrated satisfactory proficiency on second drill
attempt. 74 SOLAS 20 II-2/15.2.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2025
Resolution: The crew demonstrated satisfactory proficiency on the second drill attempt. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 June 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The remote winch release cable for the #1 lifeboat/rescue boat had a seized pulley preventing it from automatically paying out as the boat was lowered. 74 SOLAS 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2025
Resolution: Crew lubricated and acuated pulley. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2025
Resolved
All life-saving appliances and arrangements shall comply
with the applicable requirements of the Code. All life-saving
appliances shall be clearly marked with approval information including the Administration which approved it, and any operational restrictions. Numerous lifejackets in the lifeboat storage bins have faded approval and operation restrictions are no longer readable due to fading. 74 SOLAS 20 III/34 LSA Code 1.2.2.9; 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2025
Resolved 22 July 2025
Resolution: Lifejackets in lifeboat storage bins examined and now found faded ones replaced with new approved Jackets. Lifejackets now considered satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2025
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances shall be fitted with retro-reflective material where it will assist in detection. Throughout lifeboat lifejacket storage areas, numerous lifejackets had retroreflective tape missing or faded. 74 SOLAS 20 III/34 LSA Code 1.2.2.7; 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2025
Resolved 22 July 2025
Resolution: Lifejackets throughout storage areas with missing or faded retro-reflective tape examined and now found replaced with new approved lifejackets. Lifejackets now considered satisfactory.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 June 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Fire screen door (location numbers: 3.301, 3.073, 4.007B) did not close and secure as designed. 74 SOLAS 20 II-2/14.1.1
Action required: 10 - Deficiency Rectified
Resolved 8 June 2025
Resolution: Crew made adjustments to doors for them to close completely and latch.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 June 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. The fire fighting hose on Deck Zero near the Liquor Room was punctured during the fire drill. 74 SOLAS 20 II-2/14.1.1
Action required: 10 - Deficiency Rectified
Resolved 8 June 2025
Resolution: Crew replaced hose with a spare.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 June 2025
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. The following fire doors did not close due to worn gasket material, or they need adjustment to the latch or closing mechanism: FSD C13, FSD C017, FSD PM005. 74 SOLAS 97 II-2/30.4.1
Action required: 10 - Deficiency Rectified
Resolved 8 June 2025
Resolution: Crew made adjustments to doors for them to close completely and latch.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures local power accumulators for power-operated doors shall be provided in the immediate vicinity of the doors to enable the doors to be operated at least 10 times (fully opened and closed) using the local controls. F.S.D. 5.36 did not open upon local operation. 74 SOLAS 97 II-2/30.4.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2024
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. F.S.D. #4.008A, #1.47, #1.009 did not close upon local operation. 74 SOLAS 97 II-2/30.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 December 2024
Resolved
Any required automatic sprinkler, fire detection, and fire alarm system shall be capable of immediate operation at all times. Two smoke detectors in main galley found inoperable, one in chef's office and one labeled B0259. 74 SOLAS 97 II-2/12.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 December 2024
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. F&B Manager's Office is a "room-in-room" configuration within the Deck 3 main galley. The only means of escape from the office is into the galley. There is a window that looks into an adjacent office but does not give an adequate view of the galley. The office has no means of immediate and clear notification of fire in the surrounding space. 74 SOLAS 97 II-2/28.1.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 4 February 2025
Resolution: Windows of Chef Office to the galley and between the Assistant F&B Manager office and Chef Office were cleared to provide a better view to the surrounded spaces forward.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 June 2024
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. Secondary escape from "The Circle C" lounge was stuck in a closed position and unable to be opened as designed as an emergency exit. 74 SOLAS 97 II-2/28.1.2
Action required: 10 - Deficiency Rectified
Resolved 13 June 2024
Resolution: Deficiency rectified
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 December 2023
Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed. FSDs 0.80 abd 0.90 in the garbage room did not latch.
74 SOLAS 97 II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: Crew replaced latches on doors so that they closed securely.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 14 December 2023
Resolved
MUster and embarkation stations shall be adequately illiminated by lighting supplied from the emergency source of electrical power required by regilation II-I/42 or II-I/43. Two embarkation lights on the starboard side aft of the MES are nonoperational.
74 SOLAS 97 III/11.4
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: Crew replaced lights and made operational.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 December 2023
Resolved
Spaces are classified IAW their fire resk as shown in categories 1-14. Stairs 240 and 200 are category 2 spaces, where storage of combustibles is prohibited. PSCO observed combustible materials stored in stairs 240 and 200.
74 SOLAS 97 II-2/26.2.2
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: Crew removed stored materials from stairways 200 & 240.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 December 2023
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall have an approximately uniform rate of closure of no more than 40 seconds and no less than 10 seconds. FSDs A.03, A.09, B.15, 1.07, 2.29, 4.017 and door in way of a provision room did not securely close within the proper time frame.
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: Crew adjusted rate of closure.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 June 2023
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Stairwell guides on Decks 4, 5, and 7 of the mid stairwell, Food Prep Room 24 on Deck 0, and Main Laundry on Deck A crews were unfamiliar with ships emergency procedures. 16ac, 74 SOLAS 20 III/19.2.1.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 20 June 2023
Resolution: Vessel provided class statement attesting to recitification of deficiencies.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 June 2023
Resolved
A door designed to re-open upon contacting an object in its path shall re-open sufficiently to allow a clear passage of at least 0.75m but no more than 1m. PSCO witnessed FSD 4.069 continue to close with contact bar pressed. 50ac, 74 SOLAS 97 II-2/30.4.2.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 20 June 2023
Resolution: Vessel provided class statement attesting to recitification of deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 June 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed davit brake on #2 Lifeboat/Rescue Boat
was sticking during operation. 50ac, 74 SOLAS 20 III/20.2.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 20 June 2023
Resolution: Vessel provided class statement attesting to recitification of deficiencies.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 June 2023
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing. FSDs 10.001D, 4.014, 1.18, 1.17, A.72, and C.01 did not close. 10c, 74 SOLAS 97 II-2/30.4.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2023
Resolution: Deficiency Rectified
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 June 2023
Resolved
The number and position of hydrants shall be such that at least two jets of water not emanating from the same hydrant, one of which shall be from a single length of hose, may reach any part of the ship normally accessible to the passengers or crew while the ship is being navigated. Fire Station 6.19 on Deck 6 was unable to be opened, rendering the fire station inoperational and not allowing for two jets. 10c, 74 SOLAS 97 II-2/4.5.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2023
Resolution: Deficiency Rectified
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 December 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue Boat #1 rudder was unable to turn to port. 74 SOLA 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2022
Resolved
Means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be photoluminescent material or marked by lighting. 74 SOLAS 01 II-2/41-2.4.7
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Rectified.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 December 2022
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Crew members assigned to lifeboats 17, 21, and 25 were not familiar with locations of lifeboat equipment or arrangments for emergency steering nor emergency bilge pumping.
74 SOLAS 20 II/19.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Recitified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2022
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to stairway forming a vertical escape. Galley workshop in Deck 3 galley stbd side has only one means of escape, and no means to notify crew inside in case of fire in galley. 74 SOLAS 97 II-2/28.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2022
Resolved 6 February 2023
Resolution: Vessel provided class report. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 December 2022
Resolved
All openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed FD 0.086 in Recycling Room, not able to be closed due to storage of waste bags.
74 SOLAS 97 II-2/30.1
Action required: 10 - Deficiency Rectified
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Rectified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2022
Resolved
Escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting, Lighted escape sign in Sunshine Restaurant, Deck 3 aft stbd side was not lit.
74 SOLAS 01 II-2/41-2.4.7
Action required: 10 - Deficiency Rectified
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 December 2022
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed fire door 0.089 with broken latch, unable to be closed.
74 SOLAS II-2/30.1
Action required: 10 - Deficiency Rectified
Due 15 December 2022
Resolved 15 December 2022
Resolution: Deficiency Rectified.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 16 June 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. Multiple alarm indicators were not functioning in the engine room. (Cite: 74 SOLAS 20 I/11)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 28 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 June 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. On multiple life boats, the outside hand rails were loose or unsecured. (Cite: 74 SOLAS 20 III/20.2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 28 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2022
Resolved
Internal combustion engines of a cylinder diameter of 200 mm or a crankcase volume of 0.6m3 and above shall be provided with crankcase explosion relief valves of a suitable type with sufficient relief area. Crankcase explosion relief valves were painted. (Cite: SOLAS 2004 II-I/27.4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 30 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
01 - Certificates & Documentation › 013 - Documents › Certificate or documentary evidence of financial security relating to shipowners liability
Issued 16 June 2022
Resolved
A copy of the documentation, as approved by the Administration indicating that the alternative design and arrangements comply with this regulation, shall be carried on board the ship. Vessel missing document indicating the approved alternative design. (Cite: SOLAS III/38.4.2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 28 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 June 2022
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. Crew could not provide training records of the individual doing inspections on the life raft. (Cite: 74 SOLAS 97 III/20.3.1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 30 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 June 2022
Resolved
All openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Fire door F.S.D.B.01 was damaged and did not meet fire resistance standards. (Cite: 74 SOLAS 01 II-2/30.1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 30 June 2022
Resolution: received, reviewed, and excepted class report. see class report in the documents
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 16 June 2022
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All the first aid kits in the life boats were not stowed in accordance with manufacturer recommendations. First aid kits should be stored in less than 25 degrees Celsius. (Cite:74 SOLAS 20 III/34)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2022
Resolved 10 August 2022
Resolution: RECEIVED ORDER COMFORMATION FOR NEW FIRST AID KIT
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 June 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. #1 life boat, which is also a rescue boat, steering was not in proper working order. (Cite: 74 SOLAS 20 III/20.2)
Action required: 10 - Deficiency Rectified
Due 16 June 2022
Resolved 16 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 June 2022
Resolved
Operational readiness, maintenance and inspections. Sight window for the locking bolt and safety pin, and the self-inspection window on the MES were painted over or unable to see through (Cite: 74 SOLAS 20 III/20.3)
Action required: 10 - Deficiency Rectified
Due 16 June 2022
Resolved 16 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 December 2021
Resolved
Openings in "A" class divisions. Fire doors in main vertical zone bulkheads and stairway enclosures shall satisfy the following requirements. Double-leaf doors equipped with a latch necessary to their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system... Various double-leaf doors had inoperable sequencing bars.
SOLAS 97 II-2/30.4.5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 27 December 2021
Resolution: Received Class Report noting all doors have been repaired and/or adjusted as appropriate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 17 December 2021
Resolved
The Administration may require that all responsible and practicable measures shall be taken to limit the entry and spread of water above the bulkhead deck...PSCOs identified missing gasket and broken securing device on aft mooring deck station vent.
SOLAS 97 II-1/20.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 December 2021
Resolved
Openings in "A" class divisions. It shall be possible for each door to be opened from each side of the bulkhead by one person only... Sliding FSD 1.47 did not close on local activation.
SOLAS 97 II-2/30.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 December 2021
Resolved
Means of escape. Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces...PSCOs found blocked or broken emergency escape doors in the Piano Bar and Kid's Club.
SOLAS II-2/28
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 December 2021
Resolved
For determining the appropriate fire integrity standards to be applied... such spaces are classified according to their fire risk as shown in categories 1 to 14... Various spaces; to include but not limited to: the machinery space, upper deck AC rooms, I95 corridor, and deck 3 port side FWD, are being improperly used for storage; not meeting the fire integrity requirements of the designed space.
SOLAS 97 II-2/26.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 19 December 2021
Resolution: Class provided report dated 19DEC21 that items were removed/relocated and def rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 December 2021
Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material...stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed...PSCOs observed excessive wastage on the aft mooring deck door and missing gasket, door in no longer weathertight.
ICLL Annex I/12
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 December 2021
Resolved
Openings in "A" class divisions. Fire doors in main vertical zone bulkheads and stairway enclosures shall satisfy the following requirements...the doors shall be self-closing and have an approximately uniform rate of closure of no more than 40s and no less than 10s with the ship in the upright position...Multiple fire doors throughout the vessel slammed erratically in 5s or less. SOLAS 97 II-2/30.4.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2022
Resolved 27 December 2021
Resolution: Received Class Report noting all doors have repaired/adjusted accordingly.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 29 April 2016
Resolved
0750 - Fire fighting appliances - Construction of doors and door frames in "A" class divisions shall provide resistance to passage of smoke and flame equivalent to the bulkhead in which situated. 02 open bolt holes were found in the frame above FSD A. 71 as well as 02 bolt holes found in the frame above FSD A.66. (Doors to carpenter shop and upholstery shop).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2016
Resolved 11 May 2016
Resolution: Class inspected and approved repairs.
Engineering › Feedwater/Condensate Water System › Piping
Issued 29 April 2016
Resolved
0330 - Accommodation - Piping systems shall be of a design adequate for service for which intended. A black water line located in stairwell 16, betwen decks 0 and 1, was found to have temporary soft patch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2016
Resolved 11 May 2016
Resolution: Class inspected and approved repairs.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 17 May 2014
Resolved
0750 - Fire Prevention - The construction of all doors and door frames in A class divisions shall provide resistance to fire as well as to the passage of smoke. The door frame to the electrical room in A-60 bulkhead outside of the port side lido galley on deck nine has fractured/incomplete welds. 74 SOLAS (97 Cons Ed) Ch II-2 Reg 30.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 May 2014
Resolved 25 May 2014
Resolution: Received Class report, Door frame now securely welded in place and fire protection materials placed between door frame and sorrounding structure. Corrective actions and door operation verified.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 May 2014
Resolved
0750 - Fire Prevention - Fire doors in main vertical zones shall be self closing. Fire screen door 9.042 is not capable of self closing.(Class is issuing statutory memorandum until repair) 74 SOLAS (97 Cons Ed) Ch II-2 Reg 30.4.1
Action required: 705 - Other - as specified
Resolved 17 May 2014
Resolution: Issue with this door was identified by crew prior to CG exam. Door is capable of being closed manually and is in a continuously manned space. Attending Class Surveyor issued a statutory memorandum until permanent repair can be made.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 May 2014
Resolved
0750 - Fire Prevention - All openings in A class boundaries shall be provided with permanently means of closing. Fire screen door 0.107 was not capable of latching. 74 SOLAS (97 Cons Ed) Ch II-2 Reg 30.1
Action required: 705 - Other - as specified
Resolved 17 May 2014
Resolution: Door was fixed by crew prior to completion of exam.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 May 2014
Resolved
0750 - Fire Prevention - A-class divisions shall be so constructed as to be capable of preventing passage of smoke and flame. An A-0 bulkhead in the engine room escape ladder well on A deck was found with four open bolt holes. 74 SOLAS (97 Cons Ed) Ch II-2 Reg 3.3.3
Action required: 705 - Other - as specified
Resolved 17 May 2014
Resolution: Deficiency was corrected prior to our departure, New bolts were installed in holes. Attending Class surveyor attested to repair.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 17 May 2014
Resolved
0960 - Means of Escape - Means of escape shall be marked by lighting or photo luminescent strip indicators on all points of the escape route. A corridor on deck 7 between A.C. station 6.7 and the main passageway did not have any required escape markings. 74 SOLAS (97 Cons Ed) Ch II-2 Reg 28.1.10
Action required: 705 - Other - as specified
Due 31 May 2014
Resolved 25 May 2014
Resolution: Received class report attesting repairs self-Adhesive photo-luminescent strip now placed at required height from deck and internal lighting units replaced. Suitable luminescent signage now placed indicating escape route.
Fire Fighting › Nozzles › Location
Issued 17 May 2014
Resolved
0725 - Fixed Fire Extinguishing Installation - Nozzles shall be fitted above bilges, tank tops and other areas over which fuel is liable to spread and also above other specific fire hazards in the machinery spaces. The space designated for the storage of flammable liquid in the machinery space is not covered by any fixed fire suppression system. FSS Code Ch 7 2.1.2.1
Action required: 705 - Other - as specified
Resolved 17 May 2014
Resolution: Deficiency was corrected prior to our departure. Crew extended existing fire suppression system over the storage space. Arrangement was attested to by attending Class Surveyor.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 May 2014
Resolved
0950 - Electric Equipment in General - Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. 03 light fixtures in corridor on deck 7 between A.C. station 6.7 and main passageway were found without covers. 74 SOLAS (97 Cons Ed) Ch II-1 Reg 40.1.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2014
Resolved 25 May 2014
Resolution: Received class report attesting repairs internal lighting units replaced.
Fire Fighting › Means of Escape › Blocked
Issued 16 February 2012
Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and liferaft from all passenger & crew spaces. There are obstacles impeding egress on deck 10 in the children's play area & spa entrance. SOLAS 74 (1997 Consol) II-2/28.1
Due 16 February 2012
Resolved 16 February 2012
Resolution: Obstacles removed.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 16 February 2012
Resolved
Cabin doors in "B" class divisions shall be of a self-closing type. The locking device for FSD 7.16 was stuck in the open position preventing the door from closing. SOLAS 74 (1997 Consol) II-2/31.1.2
Due 16 February 2012
Resolved 16 February 2012
Resolution: Door Adjusted.
Fire Fighting › Fire Hydrants › Condition
Issued 16 February 2012
Resolved
Water supply shall be immediately available from any hydrant in the interior location. The fire hydrant across from FSD 1.45 was blocked shut by a fluorescent lightbulb that was improperly stowed. SOLAS 74 (1997 Consol) II-2/4.3.4
Due 16 February 2012
Resolved 16 February 2012
Resolution: Removed fluorescent light.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 16 February 2012
Resolved
Flammable liquids are to only be kept in category (14) spaces. Only daily use is authorized in yellow flammable cabinets. There is excessive flammable liquids in the carpenter workshop, a category (13) space. SOLAS 74 (1997 Consol) II-2/26.2.2
Action required: 705 - Other - as specified
Due 19 April 2012
Resolved 17 May 2012
Resolution: Removed flammable liquids.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 16 February 2012
Resolved
The minimum for fire integrity of bulkheads and decks shall be as prescribed in tables 26.1 and 26.4. The following category (10) spaces were being used as category (13) spaces: Aft Refrigeration Compartment, Aft Auxiliary Compartment. SOLAS 74 (1997 Consol) II-2/26.2
Action required: 705 - Other - as specified
Due 19 April 2012
Resolved 17 May 2012
Resolution: Spaces were modified with the installation of automatic fixed fire extinguishing sprinkler system and are provided with smoke detection. As such the spaces referred are considered in order by Class for the storage of engines stores.
Fire Fighting › Structural - B Class Divisions › Cabin Doors
Issued 16 February 2012
Resolved
Cabin doors in B-Class divisions shall be of a self-closing type. Hold-backs are not permitted. All passenger cabin doors onboard are mounted with spring-compression hold-backs within the door slides, allowing passengers to leave cabin doors propped-open. SOLAS 74 (1997 Consol) II-2/31.1.2
Action required: 705 - Other - as specified
Due 19 April 2012
Resolved 17 May 2012
Resolution: Removed hold-back devices on all doors.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 16 February 2012
Resolved
Means of escape shall be provided with low location lighting. Category (3) space on deck 0 forward by crew gym is missing low location lighting. SOLAS 74 (1997 Consol) II-2/28.5
Due 16 March 2012
Resolved 14 March 2012
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 18 August 2011
Resolved
74 SOLAS (97 Cons) Ch II-2 reg 13.2.2 /reg 36.1.18-36.1.2. Smoke detection shall be installed in all escape routes within accommodation space. The emergency escape in engine space 5 & 6 separated by 3 floors does not provide sufficient fire detection and suppression.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2011
Resolved 9 September 2011
Resolution: Vessel installed additional sprinkler head within vertical trunk.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 18 August 2011
Resolved
SOLAS 74 (97 Cons) Ch II-2 REG12.3. Sprinkler shall be placed in an overhead position and spaced in a suitable pattern to maintain an average application rate 51/m2/min over normal area covered by sprinkler. Engine storage rooms (6)
have stowage area above the approved stowage line preventing appropriate fire suppression.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2011
Resolved 9 September 2011
Resolution: Storage racks above the stowage line were removed.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 18 August 2011
Resolved
SOLAS 74 (97 Cons) Ch II-2 Reg 28.1.10. Means of escape shall be marked by lighting or photo luminescent strip indicators. Low location lighting at fire screen door 3.51 on deck 3 was not functioning affecting escape in the event of an emergency.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2011
Resolved 9 September 2011
Fire Fighting › Water Fog Applicators › Condition
Issued 10 January 2011
Resolved
Hi-Fog system servicing engineering spaces inoperable.
Action required: 705 - Other - as specified
Due 10 February 2011
Resolved 17 January 2011
Lifesaving › Lifeboat › Propulsion Engine
Issued 29 June 2008
Resolved
No1 lifeboat/rescue boat aft arm outreach hydraulic cylinder was leaking through a pin hole in way of outer support.
Action required: 705 - Other - as specified
Due 29 June 2008
Resolved 29 June 2008
Resolution: LR certified The hydraulic cylinder has been provisionally renewed, original spare cylinder will arrive by 07/08 and will be replaced upon arrival on board. Passenger Ship Safety Certificate conditional form P has been lifted and full term P reinstated.
Lifesaving › Launching Appliances › Davit
Issued 28 January 2008
Resolved
No. 6 davit failed to hold a load durring testing and was placed in improper service.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 January 2008
Resolved 28 January 2008
Resolution: recieved class report attesting to proper repairs
Lifesaving › Launching Appliances › Davit
Issued 26 May 2007
Resolved
During the operation of Lifeboat #6 the piston of its davit broke. Lifeboat #6 was put out of service until repairs are completed. A contingency plan consisting of the reassignation of all guest & crew from LB #6 to a different lifeboat was approved & implemented by Lloyd's Register, vessel official Class Society. Repairs will begin in San Juan on 27MAY07 & finished in St. Thomas on 28MAY07
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2007
Resolved 3 June 2007
Resolution: Received Class report stating that Life boat # 6 is repared and in good working condition.
Lifesaving › Launching Appliances › Davit
Issued 14 May 2007
Resolved
#2 Lifeboat davit system has broken piston, preventing the lifeboat from lowering. Renew/replace. Provide class approval to reduced lifesaving equipment.
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Resolution: Class provided amended PSSC reducing lifesaving equipment by one lifeboat, restricting vessel to certain carriage quantity until repaired.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 July 2006
Resolved
Earth fault trip on the 6.6 KV main switchboard port section, it was found that one loose connection on the voltage transformer caused the activation of the earth fault protection relay.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 24 July 2006
Resolution: Upon examination by attending class surveyor all repairs were considered satisfactory and may be considered permanent.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 27 February 2005
Resolved
Replace pipe coming from starboard side upper sea chest at top.
Condition: Improper/Lack of Maintenance
Due 27 March 2005
Resolved 22 March 2005
Engineering › Feedwater/Condensate Water System › Evaporator, High Pressure
Issued 27 February 2005
Resolved
Repair leak on starboard side shell aft, portside of evaporator.
Condition: Improper/Lack of Maintenance
Due 27 March 2005
Resolved 22 March 2005
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 23 August 2004
Resolved
REPAIR FOWARD INCINERATOR
Due 29 September 2004
Resolved 20 September 2004
Resolution: Received report from [name withheld] [name withheld] attesting to proper repair of Number 1 incinerator.
Fire Fighting › Structural - A Class Divisions
Issued 1 September 2002
Resolved
The following fire doors were not latching properly: 641 and 642. Repairs were conducted on the spot. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 1 September 2002
Resolved 1 September 2002
Resolution: Corrected on the spot.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 1 September 2002
Resolved
The following smoke detectors were found inoperative during random testing: A1180 and B 0632. Both were repaired prior to departing the vessel.
Condition: Unknown
Due 1 September 2002
Resolved 1 September 2002
Fire Fighting › Structural - A Class Divisions
Issued 1 September 2002
Resolved
Found that an unused space was being used for unauthorized storage in accordance with the vessel structural fire protection plans. Had stored items removed prior to departing vessel. LEGACY COMPONENT DESC: Stowage
Condition: Placed in Improper Service
Due 1 September 2002
Resolved 1 September 2002
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 10 June 2002
Resolved
Provide a Class report attesting to he proper operation of the Emergency UPS.
Condition: Unknown
Due 1 July 2002
Resolved 1 July 2002
Resolution: Received Class report, repairs complete
Electrical › Lighting (emergency)
Issued 10 June 2002
Resolved
Provide a Class Report attesting to the proper operation of the transitional lighting system and the automatic operation of Circuit Breaker 956.
Condition: Unknown
Due 10 June 2002
Resolved 10 June 2002
Resolution: Received Class report, repairs complete
Electrical › Electric Generation Source (emergency)
Issued 10 June 2002
Resolved
Provide a techical report detailing the failure of the Emergency UPS.
Condition: Unknown
Due 31 August 2002
Resolved 1 September 2002
Resolution: See the attached report in Documents and Certificates.
Electrical › Electric Generation Source (emergency)
Issued 10 June 2002
Resolved
Provide confermation that Class is satisfied that the CO2 start inhibit of the emergency generator has been disabled or overriden.
Condition: Design Flaw
Due 31 August 2002
Resolved 1 September 2002
Resolution: Inhibit was overriden and approved by the Class Society. Fire fighting proceedures were change to reflect that the emergency generator had to be secured prior to discharging CO2 into the emergency generator space.
Electrical
Issued 8 July 2001
Resolved
REPLACE BROKEN UNIVERSAL JOINT ON PVC PIPE THGAT SUPPLIES WATER TO THE JACUZZI INSIDECO2 RM#5. REPLACE PRIOR TO 20JUL01
Condition: Unknown
Due 22 July 2001
Resolved 7 August 2001
Accommodation/Occupational Safety
Issued 8 July 2001
Resolved
RENEW/REPLACE SIGN FOR EMERGENCY EXIT IN B'OSN STORAGE ROOM. COMPLETE PRIOR TO 20JUL01.
Condition: Unknown
Due 22 July 2001
Resolved 7 August 2001
Fire Fighting
Issued 8 July 2001
Resolved
REPAIR/REPLACE GLASS DOORS LEADING TO FIRE STATION DOOR 4.46 AND 4.45 NEAR GALAXY DINING ROOM SUCH THAT GLASS DOOR CANNOT OPEN INWARD AND REMAINS OPENIMPENDING THE CLOSING OF THE FIRE SCREEN DOORS. CORRECT BY 08AUG01. PROVIDE CLASSIFICATION SOCIETY REPORT.
Condition: Unknown
Due 8 July 2001
Resolved 8 July 2001
Electrical
Issued 8 July 2001
Resolved
RENEW/REPLACE ELECTRICAL WIREING IN FC#27. COMPLETE PRIOR TO 20JUL01.
Condition: Unknown
Due 22 July 2001
Resolved 7 August 2001
Accommodation/Occupational Safety
Issued 8 July 2001
Resolved
RENEW/REPLACE THE DOOR OPENING DEVICE WHEN INSIDE THE REEFER LOCATED IN BASE BY THE CASINO. COMPLETE PRIOR TO 20JUL01.
Condition: Unknown
Due 22 July 2001
Resolved 7 August 2001
Fire Fighting
Issued 8 July 2001
Resolved
REPAIR/REPLACE LOCKING DEVICES FOR FIRE STATION DOORS: DK-9 FIRE STATION 7,DK-8 FIRE STATION 14. COMPLETE PRIOR TO 20JUL01
Condition: Unknown
Due 22 July 2001
Resolved 7 August 2001
Electrical
Issued 8 July 2001
Resolved
RENEW/REPLACE LOW LEVEL LIGHTING AT/BY FIRE STATION DOOR 1.0. COMPLETE PRIOR TO 20JUL01.
Condition: Unknown
Due 22 July 2001
Resolved 7 August 2001
Lifesaving
Issued 14 January 2001
Resolved
Several 5 gallon drums of Muratic acid were stored next to the Marine Sanitation device. Relocate HAZMAT to an adequate storage location IAW SOLAS 74 as amended VII/6.1
Condition: Unknown
Due 14 January 2001
Resolved 14 January 2001
Lifesaving
Issued 14 January 2001
Resolved
Clean excessive lint build-up of dryer ducts in the crew laundry space.
Condition: Unknown
Due 14 January 2001
Resolved 14 January 2001
Fire Fighting
Issued 14 January 2001
Resolved
06 sprinkler heads were either missing or damaged in the handling area located on deck "0." Replace and renew damaged/missing sprinkler heads IAWSOLAS 74 as amended II-2/12.1.1
Condition: Unknown
Due 14 January 2001
Resolved 14 January 2001
Accommodation/Occupational Safety
Issued 15 July 2000
Resolved
REMOVE EQUIPEMENT FROM IN FRONT OF EMERGENCY EXIT DOOR 064 ON 0 DECK
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Fire Fighting
Issued 15 July 2000
Resolved
HAVE STAFF TRAINING CENTER CATRGORIZED, ADDED TO FIRE PLANS AND APPROVED BYCLASS.
Condition: Unknown
Due 15 July 2000
Resolved 15 July 2000
Fire Fighting
Issued 15 July 2000
Resolved
REPAIR FIRE DOUBLE FIRE DOOR SEQUENCERS FOR FD 4.22 AND FD 4.12 AND INSPECTALL OTHER SQUENCERS.
Condition: Unknown
Due 15 July 2000
Resolved 15 July 2000
Fire Fighting
Issued 15 July 2000
Resolved
REMOMVE PHOTO GALLERY DESK FROM PASSAGEWAY
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Fire Fighting
Issued 15 July 2000
Resolved
REMOVE WELDING EQUIPMENT FROM MARSHALLING AREA, AND HAVE AREA CATEGORIZED AND UPDATE FIRE PLAN WITH CLASS APPROVAL.
Condition: Unknown
Due 15 July 2000
Resolved 15 July 2000
Fire Fighting
Issued 15 July 2000
Resolved
REPAIR DAMAGED FIRE DAMPER CONTROL SWITCH BOXES 30A30 AND 30A31
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Fire Fighting
Issued 15 July 2000
Resolved
REMOVE DESK, COMPUTER AND OTHER OFFICE EQUIPMENT FROM CHEMICAL STORES IN PHOTO LAB.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Electrical
Issued 5 January 2000
Resolved
EMERGENCY GENERATOR UNABLE TO START USING ELECTRICAL STARTING SYSTEM.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Fire Fighting
Issued 21 July 1999
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 21 July 1999
Resolved 21 July 1999
Fire Fighting
Issued 11 July 1999
Resolved
REPAIR OR REPLACE THE LOW-VOLTAGE DETECTION CABLE TO FIRE DAMPER # CO-20252
Condition: Unknown
Due 11 July 1999
Resolved 11 July 1999
Fire Fighting
Issued 11 July 1999
Resolved
REPAIR THE "EARTH FAULT" SHOWN ON BOTH THE "A" UNIT AND THE "B" UNIT OF THESMOKE DETECTION SYSTEM
Condition: Unknown
Due 11 July 1999
Resolved 11 July 1999
Fire Fighting
Issued 24 January 1999
Resolved
Prior to 11 March 1999, provide documentation from vessel's classification society addressing lack of smoke detector in way of the purifier room. SOLAS 74 (amended), Chapter II-2, Regulation 13.1.11.
Condition: Unknown
Due 24 January 1999
Resolved 24 January 1999
Construction/Loadline
Issued 12 July 1998
Resolved
Provide Class report addressing installation of pipe collar thru bulkhead IWO #4 WTD. Pipe is pickup water for R.O. watermaker.
Condition: Unknown
Due 20 July 1998
Resolved 10 August 1998
Engineering
Issued 5 July 1998
Resolved
Prior to departue, provide a statement of fact from the vessel's classification society attensting to the satisfactory operation of the portside controlable pitch propeller in the automatic mode.
Condition: Unknown
Due 5 July 1998
Resolved 9 July 1998
Documentation
Issued 3 May 1998
Resolved
Prior to 20MAY98 provide statement of fact from class society addressing modifications and proper operations of the oily water separator.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Lifesaving
Issued 20 July 1997
Resolved
Provide documentation from the vessel's Flag Administration addressing the vessel's working language as required by SOLAS 1974 (95 Amended), Chapter V, Regulation 13C.
Condition: Unknown
Due 20 July 1997
Resolved 20 July 1997
Lifesaving
Issued 20 July 1997
Resolved
Provide on board for review, a Flag Administration approved Search and Rescue Plan in accordance with SOLAS 1974 (95 Amended), Chapter V, Regulation 15.
Condition: Unknown
Due 20 July 1997
Resolved 20 July 1997