MAURY USCG vessel records
← All vessels

CARNIVAL PARADISE

Built
1994
Last inspected
16 February 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 February 2026
…with no type recorded50
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9120877
483759
Flag
PANAMA
Maury page id
psix-483759

Documentation record

Tonnage as PSIX records it71925 - Regulatory (Subpart C or D), Gross Ton
71925 - Convention (Subpart B), Gross Ton
47873 - Regulatory (Subpart C or D), Net Ton
47873 - Convention (Subpart B), Net Ton
7154 - Dead Weight, Ton
36089 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 89 inspections, each with its date, unit and type; 60 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CARNIVAL SUNSHINE Passenger (Inspected) · MISLE 448228 · 12 January 2022 · activity 7426615DOUBLE SKIN 19 Tank Barge · MISLE 473550 · 20 January 2018 · activity 6342896QUANTICO CREEK Towing Vessel · MISLE 1077107 · 20 January 2018 · activity 6342896

Inspection history · 89

16 February 2026 PSC A · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8309960
14 January 2026 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8296695
11 November 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8266948
26 October 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8258796
29 September 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8243900
16 September 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8235373
12 May 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8133439
31 March 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8104123
17 February 2025 COC-CVE Annual
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8075172
21 November 2024 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8039341
24 October 2024 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8024462
24 October 2024 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8025971
15 August 2024 COC-CVE Quarterly · PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7981991
14 August 2024 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7981006
19 February 2024 COC-CVE Annual · PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7865369
6 February 2024 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7861345
13 November 2023 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7824223
14 September 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7798013
21 August 2023 PSC B · COC-CVE Quarterly
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7771908
16 March 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7651836
25 February 2023 PSC A · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7641832
10 January 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7624640
6 October 2022 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7572620
4 October 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7571214
5 September 2022 COC-CVE Quarterly · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7548865
25 July 2022 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7523067
30 May 2022 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7479734
8 March 2022 Ballast Water Examination · COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7406978
12 January 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7426615
3 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935076
27 March 2020 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6932388
15 February 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6911028
10 February 2020 MARPOL Annex VI Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6906030
21 January 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6894488
18 January 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6891985
18 January 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6895744
22 December 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6881600
20 December 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6881620
29 November 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6868566
18 November 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6859969
9 November 2019 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6852868
4 November 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6850833
9 October 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6831492
4 October 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6828470
23 September 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6828440
23 September 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6828462
19 September 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6819642
9 September 2019 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6805615
26 August 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6803428
22 August 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6796203
26 July 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6766684
15 July 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6753668
14 July 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6753714
16 May 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6696445
15 May 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6696945
14 April 2019 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6671093
21 March 2019 Ballast Water Examination · COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6644460
21 March 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6654942
19 February 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6629859
7 February 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6622510
17 December 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6600257
3 December 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6593521
29 November 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6591043
24 November 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6587620
16 November 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6585463
27 October 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6570502
10 September 2018 Ballast Water Examination · COC-CVE Annual · Administrative Inspection · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6534318
1 September 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6533075
1 September 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6533202
26 July 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6498744
2 July 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6473958
5 April 2018 Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6385287
23 March 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6377242
18 February 2018 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6359770
20 January 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6342896
6 November 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6303461
19 October 2017 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6290722
19 October 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6293030
30 September 2017 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6277898
19 June 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6180549
4 May 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6147314
23 March 2017 COC-CVE Quarterly · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6110277
27 February 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6096451
27 February 2017 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6096738
26 January 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6078422
15 December 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6059873
23 September 2016 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6007410
11 April 2016 Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5851797
7 April 2016 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5849187

Deficiency record · 60

11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 17 February 2026 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II- I/42 or II-1/43. PSCO observed non-operational emergency lighting forward of lifeboat 16, aft of lifeboat 20 and in midship area of vessel. 74 SOLAS 97 III/11.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Light bulbs were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 February 2026 Resolved
Hinged fire doors in stairway enclosures, main vertical zone bulkheads and galley boundaries which are normally kept open shall be self-closing and be capable of release from a central control station and from a position at the door. PSCO observed FSD 1403, 429, and 350 incapable of self closure. 74 SOLAS 01 II-2/41-2.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Doors hinges were tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 February 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed lifeboat 20 with engine insufficiently secured to engine mounts and fuel oil in the bilge. 74 SOLAS 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Engine was secured to the mount and fuel oil cleaned up.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 17 February 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed lifeboats 16 (stbd engine), 17 (port engine), and 19 (both engines) fail to start. Additionally, lifeboat 17 (engine) could not be turned off. 74 SOLAS 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Crew was trained on how to properly engergize the lifeboats and instructions were updated.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 February 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed emergency water locker seized shut on lifeboat 9. 74 SOLAS 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Locker was unsiezed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 February 2026 Resolved
For determining the proper fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk, as shown in categories (1) to (14) below. PSCO observed storage of combustible materials in category (10) space in fan room 1104. 74 SOLAS 97 II-2/26.2..2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Combustible materials were removed from the space and stowed in its respective area.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 February 2026 Resolved
Each section of sprinklers shall be capable of being isolated by one stop valve only. The stop valve in each section shall be readily accessible and its location shall be clearly and permanently indicated. Means shall be provided to prevent the operation of the stop valves by any unauthorized person. PSCO observed absence of tamper alarm on section valve 48 on deck 10. 74 SOLAS 01 II-2/12.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Tamper alarm was fixed to sound.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 February 2026 Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention within 2 min an audible alarm shall be automatically sounded throughout the crew accommodation and service spaces, control stations and machinery spaces of category A. PSCO observed manual call point 5164 incapable of activation. 74 SOLAS 01 II-2/13.1.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Call point was replaced.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 17 February 2026 Resolved
Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection complying with the provisions of paragraph 3. PSCO observed excessive storage of linens and other combustible materials blocking access to the international shore connection valve, just aft of the forward mooring station. 74 SOLAS 97 II-2/19.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2026
Resolution: Combustible materials moved from space to respective approved locations.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 February 2026 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins.PSCO observed stairway guide deck 14 forward stairwell unfamiliar with duties. 74 SOLAS 20 III/19.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2026
Resolution: Crew member was given extra training along with refresher training.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 February 2026 Resolved
The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to persons. PSCO observed inoperable action bar on FSD 356, 913, 912, and 915. 74 SOLAS 81 Amend II-2/30.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 February 2026
Resolution: All screen doors were repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 February 2025 Resolved
Every fuel pipe from a storage, settling or daily tank shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside of the space. PSCO observed HFO valves 4, 7, 8 did not close when actuated. 74 SOLAS (81) II-2 / 15.2.5 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2025
Resolved 17 February 2025
Resolution: Acuated remote fuel valves.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 February 2025 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed crewmembers on lifeboats #10, #15, and #21 were unfamiliar with the location of the emergency fuel shutoff valves. Additionally, crewmembers in lifeboat #20 struggled with shifting engine in and out of gear. 74 SOLAS (20) III/19.2.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2025
Resolved 17 February 2025
Resolution: Crew provided trainiing from Safety officer.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 February 2025 Resolved
The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to persons. PSCO observed FSD 414 on MVZ 6 closing in 4 seconds. 74 SOLAS (81) II-2 / 30.4 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2025
Resolved 17 February 2025
Resolution: Adjusted FSD closure rate.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 February 2025 Resolved
The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to persons. PSCO observed safety crash bar on sliding FSD 917 failed to operate. 74 SOLAS (81) II-2 / 30.4 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2025
Resolved 17 February 2025
Resolution: Adjusted FSD crash bar sensitivity.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 February 2025 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed the deck in pool machinery room on deck 9 had an excessive amount of water on it, creating shock hazard with the electrical panels in the same space. 74 SOLAS (04) II-1 / 40.1.3 10c
Action required: 10 - Deficiency Rectified
Due 17 February 2025
Resolved 17 February 2025
Resolution: Arrested leak and cleaned deck.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2024 Resolved
All waste-receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed combustible materials inside plastic waste receptacle. 74 SOLAS 97 II-2/18.5 17C
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2024
Resolved 29 August 2024
Resolution: Plastic waste receptacle removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed light cover missing in way of call point L50-A43. 74 SOLAS 04 II-1/40.1.3 17C
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2024
Resolved 29 August 2024
Resolution: Light cover was replace.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 August 2024 Resolved
Electrical installations shall be such that: Electrical services essential for safety will be ensured under various emergency conditions. PSCO observed extinguished light in medical disaster cart room. 74 SOLAS 04 II-1/40.1.2 17C
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2024
Resolved 29 August 2024
Resolution: Light-bulb was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 August 2024 Resolved
In passenger ships, doors other than power-operated watertight doors, shall be so arranged that positive closure is assured in case of fire in the space. PSCO observed broken hinge on FSD 001, preventing door from self-closing. Additionally, PSCO observed FSD 856 failed to latch. 74 SOLAS 81 Amend II-2/11.2.3 17C
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2024
Resolved 29 August 2024
Resolution: The hinge in FSD 001 was replaced. FSD 856 was adjusted to latch upon closing.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 August 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The stowage of combustibles is prohibited in a category 10 space. PSCO observed stowage of wood tiles inside the Fan Room #504 (Category 10 Space). Additionally, PSCO observed the stowage of combustible materials inside Fan Room #804 (Category 10 Space). 74 SOLAS 81 Amend II-2/26.2.2 17C
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2024
Resolved 29 August 2024
Resolution: Fan room wood tiles were removed and properly stowed. The ventilation room combustible material was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 August 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed wire rope on crane at liferaft station number 7 was improperly spooled. 74 SOLAS 20 III/20.2 17C
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2024
Resolved 29 August 2024
Resolution: Wire rope was re-spooled.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 August 2024 Resolved
When double swing doors are permitted, they shall have a latch arrangement which is automatically engaged by the operation of the door release system. PSCO observed latching arrangement on FSD 359 failed to latch door properly. 74 SOLAS 81 Amend II-2/30.4 17C
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2024
Resolved 29 August 2024
Resolution: FSD 359 was adjusted to latch upon closure.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 29 August 2024 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed stairway guides assigned to numbers 8 and 9 aft stairways and number 4 forward stairway were unfamiliar with required knowledge. Additionally, PSCO observed crew members assigned to lifeboat number 12 were unfamiliar with how to operate emergency steering and general knowledge relating to flares, TPAs, and how much water each passenger shall receive. PSCO observed crew assigned to lifeboat number 14 were unfamiliar with how to shut off engine and crew assigned to lifeboat 21 were unfamiliar with how to operate the fuel shut-off. 74 SOLAS 20 III/19.2.1 17C
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2024
Resolved 29 August 2024
Resolution: Additional training was conducted by the Safety Officer and said crew members were reevaluated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2024 Resolved
Fire-extinguishing appliances shall be kept in good working order and be available for immediate use at all times. PSCO observed a pinhole leak in firehose at station number 86. 74 SOLAS 97 II-2/21 17C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 29 August 2024
Resolution: The fire hose at station 86 was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 August 2024 Resolved
The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to persons. PSCO observed the closure rate of FSD 003 was too fast. 74 SOLAS 81 Amend II-2/30.4 10C
Action required: 10 - Deficiency Rectified
Due 29 August 2024
Resolved 29 August 2024
Resolution: FDS 003 was adjusted to close at the proper rate of close.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 February 2024 Resolved
The minimum for integrity of all bulkheads and decks shall be as prescribed in tables 26.l to 26.4. PSCO observed combustible materials stored in a category 10 space in fan room 1004 and 902. 74 SOLAS 81 Amend II-2/26.1 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2024
Resolved 19 February 2024
Resolution: Combustible material was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 February 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that engine mount in lifeboat 4 was loose, missing bolts, and caused engine to vibrate dangerously when operated. 74 SOLAS 20 III/20.2 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2024
Resolved 19 February 2024
Resolution: Mounts were repaired. Op tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 February 2024 Resolved
In passenger ships, doors other than power-operated watertight doors, shall be so arranged that positive closure is assured ;n case of fire in the space, by power-operated closing arrangements or by the provision of self-closing doors capable of closing against an inclination of 3.5 opposing closure and having a fail-safe hook-back facility, provided with a remotely operated release device. PSCO observed fire screen doors 305, 803, 838, 837, 831, 815, 801, and 1106 failed to close and latch properly. 74 SOLAS 81 Amend II-2/11.2.3 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2024
Resolved 19 February 2024
Resolution: Doors adjusted and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 February 2024 Resolved
Hinged fire doors in stairway enclosures, main vertical zone bulkheads and galley boundaries which are normally kept open shall be self-closing and be capable of release from a central control station and from a position at the door. PSCO observed double leaf doors leading from fwd stairway to the Normandie Main Lounge only closed on one side. Additionally, hinged door 508 in fwd stairway failed to close. 74 SOLAS 01 II-2/41-2.4.1 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2024
Resolved 19 February 2024
Resolution: Crew adjusted and op test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 February 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a hydraulic oil leak in lift machinery room on deck 11 stbd side. Until deficiency is rectified, equipment must be locked out/tagged out IAW vessel SMS. 74 SOLAS I/11 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2024
Resolved 3 April 2024
Resolution: Received class report attesting to repair.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 February 2024 Resolved
Every crewmember shall be given instructions which shall include but not necessarily be limited to operation and use of the ship's inflatable rafts, problems of hypothermia, first-aid treatment for hypothermia and other appropriate first-aid procedures, special instructions necessary for use of the ship's life-saving appliances in severe weather and severe sea conditions, operation and use of fire extinguishing appliances, and risks associated with enclosed spaces and on-board procedures for safe entry. PSCO observed a lack of knowledge of locations of equipment on lifeboat as well as survival procedures. 74 SOLAS 20 III/19.4.2 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2024
Resolved 1 March 2024
Resolution: Received class report demonstrating satisfactory training.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 19 February 2024 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed bent sprinkler head in pantry next to Blue Iguana restaurant. 74 SOLAS 20 II-2/14.1.1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2024
Resolved 1 March 2024
Resolution: Received class report attesting to replacement of sprinkler head.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 February 2024 Resolved
The minimum for integrity of all bulkheads and decks shall be as prescribed in tables 26.l to 26.4. PSCO observed missing sections of A-60 insulation in the stbd ceiling of the evaporator room in a category 11 space, which is below the engine control room, a category 1 space. 74 SOLAS 97 II-2/26.l 16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2024
Resolved 1 March 2024
Resolution: Received class report attesting to replacement of insulation.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 February 2024 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. PSCO observed the straps securing several liferafts on both port and stbd side were badly deteriorated. 74 SOLAS 20 III/20.3 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2024
Resolved 16 March 2024
Resolution: Received class report attesting that the straps were replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 February 2024 Resolved
Accommodation and service spaces, stairway enclosures and corridors shall be fitted with an automatic sprinkler system complying with the requirements of reg 12. PSCO observed items stored higher than sprinkler head in storage locker in crew lounge near RSD 7.4.9. 74 SOLAS 01 II-2/41-2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 February 2024
Resolved 19 February 2024
Resolution: Improperly stowed items were removed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 February 2024 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. PSCO observed the stbd ventilation intakes on deck 7 fwd were seized and nonfunctional. 74 SOLAS 81 Amend II-2/16.9 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 February 2024
Resolved 19 February 2024
Resolution: Ventilation closures were repaired on the spot.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 August 2023 Resolved
74 SOLAS II-2/18.5 10C All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed plastic waste receptacles in the lido galley
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 21 August 2023
Resolution: Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 21 August 2023 Resolved
74 SOLAS 81 Amend II-2/29.2 10c. Stairway enclosures shall have direct communication with the corridors and be of sufficient area to prevent congestion, having in view the number of persons likely to use them in an emergency. In so far as is practicable, stairway enclosures shall not give direct access to cabins, service lockers, or other enclosed spaces containing combustibles in which a fire is likely to originate. PSCO observed drums of cleaning chemicals stored underneath stairway 290.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 21 August 2023
Resolution: Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 August 2023 Resolved
74 SOLAS 81 Amend II-2/30.4 10c. Fire doors in main vertical zone bulkheads and stairway enclosures, other than power-operated watertight doors and those which are normally locked, shall be of the self-closing type. The speed of the door closure shall, if necessary, be controlled so as to prevent undue danger to persons. PSCO observed the speed of the doors 816, 817, 819, 839 was reasonable, however, they did not reopen on contact with an object and would therefore pose a danger to persons.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 21 August 2023
Resolution: Rectified on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 August 2023 Resolved
74 SOLAS 97 III/7.1.2 10c. At least one lifebuoy on each side of the ship shall be fitted with a buoyant lifeline complying with the requirement of paragraph 2.1.4 of the Part B: Code equal in length to not less than twice the height at which it is stowed above the waterline in the lightest seagoing condition, or 30 m, whichever is greater. PSCO observed that lifeline on starboard side lifebuoy was of insufficient length.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 21 August 2023
Resolution: Rectified on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 August 2023 Resolved
74 SOLAS 04 II-1/20.2 10c. The bulkhead deck or a deck above it shall be weather right. All openings in the exposed weather deck shall have coaming of ample height and strength and shall be provided with efficient means for expeditiously closing them weather tight. PSCO found weather tight door 183 to be inoperable. Additionally, the weather tight door n the vicinity of lifeboat 21 was found to be heavily corroded on the bottom frame and no longer weather tight.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 21 August 2023
Resolution: Rectified on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 August 2023 Resolved
74 SOLAS 20 III/34 LSA 1.2.2.7 10c All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances shall be fitted with retro-reflective material where it will assist in detection. PSCO observed the retro-reflective tape on lifeboat 19 needs to be renewed, and the retro on top of lifeboat 21 was missing entirely.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 21 August 2023
Resolution: Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 21 August 2023 Resolved
74 SOLAS 81 Amend II-2/26. 10c. The minimum for integrity of all bulkheads and decks shall be as prescribed in tables 26.1 t0 26.4. PSCO observed rags, towels, and linen storage in the fire main shore connection locker, door 6-690, as well as shore connection locker adjacent to passenger room U-2.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 August 2023
Resolved 21 August 2023
Resolution: Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 February 2023 Resolved
07126 - Fire Safety - Every oil fuel pipe, which if damaged would allow oil to escape from a daily service tank situated above the double bottom, shall be fitted with a valve which is capable of being closed from a safe position from outside the space. PSCO observed two out of the three valves in section #5 did not close and three out of three valves in section #6 did not close. SOLAS 74/78 (97 Cons). Ch. II-2/15.5 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2023
Resolution: Vessel's engineering department was able to rectify the deficiency. Lack of hydraulic oil in the system preventing the valves to activate properly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 February 2023 Resolved
07105 - The construction of all doors and door frames in "A" class divisions, with the means of securing them when close, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed the top of the frame on fire screen door 0.18, main vertical zone 7, was damaged allowing the passage of air when the door was in the closed position. SOLAS 74/78 (97 Cons.) Ch. II-2/30.2 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2023
Resolution: Vessel's engineering department was able to fix the door frame.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 February 2023 Resolved
07105 - Fire Safety - Fire doors in main vertical zone bulkheads and stairway enclosures, shall be self-closing. PSCO observed fire screen door 8.10, main vertical zone 7 did not completely close when activated. SOLAS 74/78 (97 Cons.) Ch.II-2/30.4 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2023
Resolution: Vessels crew was able to fix the FSD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 February 2023 Resolved
11101 - Life Saving Appliances - The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed unserviceable fuel caps in lifeboats 4, 6, 10, and 12 resulting in the leaking of diesel fuel into the lifeboat from the fuel tanks. SOLAS 74/78 (2020 Cons.) Ch.I/11 17c Vessel was able to make temporary repairs in order to proceed underway, however, PSCO changed the deficiency to a 40a/c.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2023
Resolution: Recieved Lloyd's class report #2189213 stating fuel caps have been replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2023 Resolved
09209 - Working and Living Conditions - All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. PSCO observed exposed dead-end wiring from converter boxes F17 and F2. SOLAS 74/78 (2004 Cons.) II-1/45.1.3 40 a/c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2023
Resolution: Recieved Lloyd's class report #2189213 stating dead-end wires have been secured.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 5 September 2022 Resolved
11131 - Every crew member with assigned emergency duties shall be familiar with these duties before the voyage. PSCO observed lack of knowledge and familiarity with the launching of life rafts in accordance with the ship's procedures. 74 SOLAS (20) III/19.2 17 AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2022
Resolution: Vessel provided training in regards to launching life rafts to all crewmembers with assigned duties, prior to PSCO's completing the exam.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 September 2022 Resolved
11129 - The function of the detection system shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at appropriate temperatures or smoke or aerosol particle having the appropriate range of density or particle size. PSCO observed crew using unapproved heat gun to test heat detectors throughout the ship. 74 SOLAS (97) II-2 / 13.1.13 50 AC
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 October 2022
Resolution: Upon review of the Class survey, vessel has been cleared of the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 September 2022 Resolved
11129 - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed missing light for lifejacket in locker across from stateroom 463. Several life jacket lights failed to activate in the locker starboard side on deck 9. 74 SOLAS (20) III/20.2 50BC
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 October 2022
Resolution: Upon review of the Class survey, vessel has been cleared of the deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 5 September 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 October 2022
Resolution: Upon review of the Class survey, vessel has been cleared of the deficiency.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 September 2022 Resolved
08199 - The number of joints in such piping systems shall be kept to a minimum and where practicable, leakages from high pressure oil fuel pipes shall be collected and arrangements provided for an alarm to be given. PSCO observed fuel leak alarms on high pressure oil fuel lines for number one, two, three, and five SSDG were masked/silenced. 74 SOLAS (97) II-2 / 15.5.1 10C
Action required: 10 - Deficiency Rectified
Resolved 5 September 2022
Resolution: Engineers investigated and found drain lines were clogged. Crew cleaned fuel lines and alarms were tested and found functioning as intended.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 March 2022 Resolved
Where the contents and use of a space are such that there is no doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements...Signage, use, and storage of materials/goods in Boatswains Workroom and Store would require CAT 14 categorization. Space is categorized as 13. Additionally, paint stores and other materials are improperly stored in CAT 2 stairwell outside Boatswain's workroom. SOLAS 81 Amend II-2/26.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 14 March 2022
Resolution: Email provided.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 March 2022 Resolved
Stairway enclosures shall have direct communication with the corridors and be of sufficient area to prevent congestion. Deck 3 (I95 corridor) contained significant storage causing congestion. SOLAS 81 Amend II-2/29.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 14 March 2022
Resolution: Email provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 November 2019 Resolved
THE MACHINERY SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE ENTENDED. PORT AZIPOD REDUCED TO 50% POWER/CAPACITY FOR PROPULSION. 74SOLAS(2004)II-1.26.1 / 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2019
Resolved 21 November 2019
Resolution: High Speed Breakers were dismantled, dried and revamped as necessary, and on completion, insulation resistance was taken in High Speed Breakers and HV Cables all with satisfactory results. Azipod #2, CC2 A drive put back in service. Fully Operational.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 September 2019 Resolved
Fire doors in main vertical zone bulkheads shall be self-closing. Fire screen door1206 did not close - 74SOLAS(97) II-2/30.4.1
Action required: 10 - Deficiency Rectified
Resolved 9 September 2019
Resolution: FSD was adjusted and witnessed to close.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 September 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order. Lifeboat #21 was unable to clutch ahead and astern during drills - 74SOLAS(14) III/20.2
Action required: 10 - Deficiency Rectified
Resolved 9 September 2019
Resolution: Repairs were effected and tested. Tested ahead and astern propulsion.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 23 February 2018 Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 23 February 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.