Records from 1998 to 2022. Most recent: inspection, 6 October 2022.
Inspection history · 67
6 October 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7573650
8 June 2021
Internal Structural Exam · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7219157
12 March 2021
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7154825
13 October 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7076286
3 April 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6934986
18 March 2020
Administrative Inspection · Load Line/Change of Employment
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6928692
9 September 2019
MTSA Verification · Periodic Inspection · In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6792772
21 September 2018
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6566115
17 July 2018
Administrative Inspection · Cargo Tank Internal
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6482354
17 May 2018
Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6417048
7 February 2018
Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6385942
20 January 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6342896
30 November 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6331821
31 October 2017
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6297659
27 October 2017
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6234444
9 February 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6101778
18 October 2016
Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6024530
31 March 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5843809
4 May 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5125995
4 March 2015
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5078318
18 December 2014
MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5041307
25 February 2014
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4805747
18 November 2013
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4754448
24 October 2013
Load Line/Change of Employment
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4742335
1 October 2013
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4726236
13 August 2013
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4682975
3 January 2012
COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4217314
12 October 2011
Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4166193
21 June 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4052419
14 June 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4047748
19 November 2010
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3894207
15 January 2010
Examination of Repairs · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3664860
15 January 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3670664
12 January 2010
Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3662604
26 February 2009
Annual Inspection · MARPOL Annex V Examination · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3422909
24 January 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3400943
9 October 2008
Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3346463
12 September 2007
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3055831
11 June 2007
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2958466
20 April 2007
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2911619
3 January 2007
COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2849278
31 October 2005
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2525484
16 September 2005
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2492170
15 July 2005
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2426909
10 June 2005
MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2383661
14 January 2005
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2274714
22 December 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2263972
17 December 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2261160
15 December 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2260013
8 December 2004
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2255767
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979692
15 September 2003
Internal Structural Exam · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1900861
6 March 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1755085
13 September 2002
Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1675233
14 March 2002
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1493733
11 September 2001
Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1462263
8 September 2001
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 520930
29 September 2000
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 822835
15 September 2000
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 822919
2 November 1999
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 804359
7 June 1999
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 489407
8 April 1999
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 513723
27 January 1999
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 789808
24 January 1999
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 441467
9 January 1999
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 450877
28 November 1998
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 503140
18 September 1998
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1464774
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 June 2021
No resolution recorded
46 CFR 91.40-3 2( c ) If during an internal structural , cargo tank examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the officer in charge, marine inspection, may require the vessel to be dry docked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs.
During internal structural exam minor cracks to in way of side transverse vertical and side longitudinal in side shell voids. The cracks were minor and the opposing side of each had good welds. There were 7 total spots throughout : 2 port (1) 3P (2) 4P (2) 5P (1) and 6S (1) . Grid and re-weld. Items to be completed by end of next scheduled dry dock in 2023.
46 CFR 91.40-3 2
Condition: Invalid
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 13 October 2020
Resolved
01 - All cargo tank hatches must be clearly marked in not less than three inch lettering “Danger—Keep Out,” and all hatch covers must be closed and dogged down in such a way that the hatch cannot be opened by the use of bare hands alone. Markings on hatches were observed deteriorated and illegible. 46CFR35.05-15(b)(3)(ii)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2020
Resolved 12 March 2021
Resolution: All appropriate hatches have been marked.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 13 October 2020
Resolved
The barge must have a working means for releasing the anchor that can be operated safely by one or two persons. Release means were inoperable for inspection. 46CFR32.15-15(f)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2020
Resolved 12 March 2021
Resolution: Anchor was shown to be properly working.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 October 2020
Resolved
Each hose must be marked with one of the following: For oil products, the words “OIL SERVICE," Each hose also must be marked with the following, Maximum allowable working pressure. 33CFR154.500(e)(2, 33CFR154.500(f)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2020
Resolved 12 March 2021
Resolution: All hoses have been properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 October 2020
Resolved
Each liferaft must be stowed to permit manual release from its securing arrangements. Liferaft was not stowed in proper fashion to permit manual release. 46CFR31.36-1, 46CFR199.130(c)(1)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2020
Resolved 12 March 2021
Resolution: Life raft has been removed.Vessel not required to have it onboard- Unmanned Barge.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 13 October 2020
Resolved
Fuel filters are required to meet standards specified by ASTM F 1201. Fuel filter onboard was not of type suitable for intended service. 46CFR56.60-1(b)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2020
Resolved 11 March 2021
Resolution: Fuel filters have been replaced with the correct model.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 March 2020
Resolved
If, during an internal structural examination, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs.
Watertight hatches for #1 Port and Starboard Voids, and Starboard Aft Peak found in wasted condition. Repair or replace .
IAW: 46 CFR 31.10-21 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 3 April 2020
Resolution: Inspected 03 new hatch covers. all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2019
Resolved
DEF CODE: 02108
MI found electrical wiring going to the mast headlight switch not sealed.
46 CFR 111.81-1
ACTION:701
ACTION CODE:C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2019
Resolution: Switch sealed, def corrected to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 September 2019
Resolved
Deficiency Code: 07116
MI found #1 and #2 cargo man hole vents needs replacement. Replace vent mesh to the attending MI satisfaction.
46 CFR 32.55-25
ACTION:701
ACTION CODE:C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2019
Resolution: Flame screens replaced with new ones, def corrected to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2019
Resolved
DEFICIENCY CODE: 02108
MI found Hydrulic motor electrical box not sealed in the wire run side. Seal wire run to the attending MI satisfaction.
46 CFR 111.81-3
ACTION:701
ACTION CODE:C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2019
Resolution: Electrical box sealed, def corrected to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2019
Resolved
DEFICIENCY CODE: 02108
MI found receptacle outlet by the galley area with out a cover. Install proper cover for the receptacle to the MI satisfaction.
46 CFR 111.79-1
ACTION:701
ACTION TAKEN:C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2019
Resolution: Receptacle cover installed, def corrected to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 September 2019
Resolved
DEFICIENCY CODE: 09203
MI found light fixture diffuser broken in the gen set room. Replace diffuser to the satisfaction of attending MI.
46 CFR 111.75-20
ACTION:701
ACTION CODE:C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2019
Resolution: Light fixture replaced completly, def corrected to the satisfaction of the MI.
Construction/Loadline › Hull › Weld
Issued 18 October 2016
Resolved
Complete attached worklist prior to receiving credit ISE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2016
Resolution: Completed all required repairs.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 March 2016
Resolved
Relocate forward life ring buoy with water light to a location outside of the hazardous zone.
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 20 April 2016
Resolution: Relocated buoy outside of hazard area.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 March 2016
Resolved
Repair port side railing, middle course, as original.
Due 22 April 2016
Resolved 20 April 2016
Resolution: Deck rail was bent back into place, welds appeared intact.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 31 March 2016
Resolved
Prove proper operation of high level/overfill visual indicator for 2 stbd tank.
Due 22 April 2016
Resolved 20 April 2016
Resolution: Vessel repaired level indicator by replacing the contact magnet.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 31 March 2016
Resolved
Provide valve postiion indicators for non-rising stem type valves in cargo system.
Due 22 April 2016
Resolved 20 April 2016
Resolution: Valve position indicators were installed on all required valves.
Construction/Loadline › Hull › Hull Plating
Issued 15 January 2010
Resolved
#1 Cargo Port Cargo Tank deck plating punctured by fallen containers. Make temporary repairs to tank deck to prevent vapor escape prior to movement of barge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 31 October 2017
Resolution: Def Administratively closed. Repairs completed in 2010 but def was never cleared.
Construction/Loadline › Hull › Hull Plating
Issued 15 January 2010
Resolved
Take vessel out of service, gas free cargo tanks # 1 P&S and make available for USCG damage survey. Submit repair proposal & make permanent repairs to vessel prior to cargo operations.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2010
Resolution: pressure test of welds conducted and passed on 1-25-2010.
Construction/Loadline › Hull › Hull Plating
Issued 12 September 2007
Resolved
Crop & renew damage to fwd rake/port corner (approx 3 ft x 2 ft).
Condition: Damaged By Earlier Event
Due 11 October 2007
Resolved 24 September 2007
Resolution: Permanent repairs completed.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 8 December 2004
Resolved
Renew flame screens on all gooseneck cargo vent lines.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2004
Resolution: Flame screens on all gooseneck cargo vent lines replaced.
Documentation › Markings/Placards
Issued 14 March 2002
Resolved
Provide vessel markings P&S bow and stern to show new owners name of vessel and hailing port. LEGACY COMPONENT DESC: Vessel Number (state)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2002
Deck/Cargo
Issued 15 September 2000
Resolved
CONDUCT ANNUAL HYDROSTATIC TEST OF CARGO PIPING IN ACCORDANCE WITH 33 CFR 156.170.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Documentation
Issued 18 September 1998
Resolved
PRIOR TO LOADING CARGO PROVIDE USCG MARINE INSPECTOR WITH AN ORIGINAL VALIDCOFR.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Deck/Cargo
Issued 18 September 1998
Resolved
PRIOR TO LOADING CARGO, INSTALL FLAME SCREENS ON #1, 2, AND 3 P/S CARGO TANKS.
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998