MAURY USCG vessel records
← All vessels

OLIVER

OLIVER is a 1961 towing vessel. The Coast Guard has recorded 36 inspections since 1989, most recently in July 2025, along with 18 deficiencies, 3 operational controls and 9 casualty investigations between 2007 and 2024.

Records from 1989 to 2025. Most recent: inspection, 24 July 2025.

Built
1961
Last inspected
24 July 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 24 July 2025
…with no type recorded27
Operational controls None recorded without a removal date
Years with a record 20 calendar years (1989–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8644357
WDM6864
Flag
UNITED STATES
Maury page id
psix-79835

Documentation record

Registered dimensions (L × B × D)78.9 ft × 24.0 ft × 8.6 ft
Registered tonnagegross 148 / net 100
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEQUITABLE EQUIPMENT COMPANY INC · MADISONVILLE, LA, UNITED STATES · built 1961
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it100 - Regulatory (Subpart C or D), Net Ton
148 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 14

Inspection history · 36

24 July 2025 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8179357
12 March 2025 Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8092701
29 May 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7869076
12 February 2024 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7864499
6 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7647761
3 December 2021 Initial Certification · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7401067
22 January 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5057126
22 January 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5057387
2 July 2013 Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4643157
7 February 2012 Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4239850
27 May 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4023601
3 March 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3957259
19 October 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3874314
17 July 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3800695
12 July 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3793869
7 July 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3789262
24 January 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3400943
18 November 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3366702
30 May 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3221973
22 February 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3171596
2 January 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2859976
11 May 2005 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2354819
25 December 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1722958
13 July 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1646339
13 December 2001 Type not recorded
No type recorded · USCGC ADAK (WPB 1333) · USCG Northeast District (CGD-NE) · Activity 1523944
11 October 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 772989
13 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 126618
11 February 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1427932
7 February 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 45327
21 January 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 17739
4 January 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 34089
10 October 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 206216
10 October 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 755771
24 July 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 227391
16 July 1993 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 184142
7 December 1989 Uninspected Towing Vessel
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1241017

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 July 2025 Resolved
Flexible connections and discharge hoses on all semi-portable extinguishers and fixed extinguishing systems must be inspected and tested in accordance with § 147.65 of this chapter. CO2 System Hose found dry rotted. Replace hose. - 46 CFR 142.240(a)(3) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2025
Resolution: Vessel replaced flexhose inkind with servicing tech.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 July 2025 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Aft Middle amber stern nav tow light was found flickering and not fully operational. Replace. - 46 CFR 140.720
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2025
Resolution: Vessel replaced and sent photo of newly installed aft middle amber aft towing navigation light.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 24 July 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. 1. Water gauge on port engine was found inoperable. Install new protective cover or new gauge. 2. Port inboard Racor filter found with inoperable fuel pressure gauge. Replace. 3. Main switchboard, lower port side electrical distribution panel found with a missing breaker that was exposed. Replace with new breaker. 4. E/R Alarm in Engineer room found with disconnected and exposed wires on the obsolete engine room alarm system. Remove. 5. Engine sump lube oil suction for flexible hose found deteriorated. 46 CFR 143.205(a) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2025
Resolution: recieved photographs from vessel satisfying the outstanding deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 July 2025 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. Three (3) individual independent smoke detectors found in staterooms to be not operational. Replace smoke detectors. - 46 CFR 142.330(b) - 10c
Action required: 10 - Deficiency Rectified
Resolved 24 July 2025
Resolution: Verified and tested new detectors prior to disembarking the vessel.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 July 2025 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port Main Engine cyl 8 found with valve cover gasket leaking diesel. Sbd Main Engine cyl 9 bolt around valve cover gasket leaking diesel. 46 CFR 143.220(a) - 46 CFR 143.220(a)
Action required: 10 - Deficiency Rectified
Resolved 24 July 2025
Resolution: Verified and tested main engine for leaks prior to disembarking the vessel. Engineer re-torqed the valve cover gasket bolts tested engine under load to verify no leaks.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 July 2025 Resolved
Retro-reflective tape on the Life Ring Bouys were observed in a deteriorated condition. - 46 CFR 141.230 - 10c
Action required: 10 - Deficiency Rectified
Resolved 24 July 2025
Resolution: Vessel renewed the retro reflective tape prior to MIs leaving vessel.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 11 June 2025 Resolved
Watertight collision bulkhead is missing to have welded and installed a watertight hatch cover. Complete the welding and installation of the collision bulkhead watertight hatch.
Action required: 705 - Other - as specified
Resolved 27 June 2025
Resolution: A WT hatch was build and installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 March 2025 Resolved
- Provide repair proposal for rudder post collar.
Action required: 705 - Other - as specified
Resolved 11 June 2025
Resolution: Repair was carried out and report provided with NDT successfull.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 May 2024 Resolved
46 CFR 143.400 (a) Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port and starboard generator windings are coated in excess oil and dirt, and require cleaning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 18 June 2024
Resolution: Windings were cleaned and free of oil and dirt.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2024 Resolved
46 CFR 140.715(a) Towing vessels must meet the communications requirements of 33 CFR part 26 and 33 CFR 164.72, as applicable. Vessel did not have a Bridge-to-Bridge Safety Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 20 June 2024
Resolution: Received the issued certificate by a local comms FCC tech.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 29 May 2024 Resolved
46 CFR 144.320 (b) Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Engine room port lights are missing dead covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 7 June 2024
Resolution: Closure devise were installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 May 2024 Resolved
46 CFR 140.610(b) The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Pilot house hatch striker plate damaged due to a temp repair or hatch dog.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 7 June 2024
Resolution: Striker plate was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 May 2024 Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. Stbd engine room door leading to engine room was missing striker plate. Repairs made and chalk tested.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 May 2024
Resolution: Vsl crew made repairs and inspectors conducted chalk test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2024 Resolved
46CFR143.205 Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Received email from vessel representative that the starboard generator is inoperable and a portable generator was installed without notice to the OCMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2024
Resolved 3 July 2024
Resolution: Received photo of vsl with out the portable generator installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2023 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. MI found spring terminal battery instead of screw post battery terminal, not properly working as designed. Provide proper battery to the satisfaction of attending MI. 46 CFR 141.360 (c)(2)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 16 March 2023
Resolution: Battery replaced with proper type and proper connections.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 March 2023 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The WTD on the port side was found with a section of missing gasket near the top knife edge and needs replacing. 46 CFR 140.610
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 16 March 2023
Resolution: Gasketing repalced and is weathertight.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 11 February 2000 Resolved
Install a break-glass cover on Kidde pull-box in galley.
Condition: Unknown
Due 4 January 2001
Resolved 26 October 2004
Resolution: CLEARED FOR ADMIN CLEAN UP.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 February 2000 Resolved
Prior to conducting operations with fire supression system ventilation shutdown system must be tested and witnessed by attending Coast Guard Marine Inspector.
Condition: Unknown
Due 4 January 2001
Resolved 26 October 2004
Resolution: CLEARED FOR ADMIN CLEAN UP.

Casualty record · 9

2 January 2007Routine · role: Involved in a Marine Casualty · activity 2859976
22 February 2008Routine · role: Involved in a Marine Casualty · activity 3171596
18 November 2008Routine · role: Involved in a Marine Casualty · activity 3366702
24 January 2009Routine · role: Involved in a Marine Casualty · activity 3400943
7 July 2010Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 dead · 8 injured · activity 3789262
17 July 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3800695
19 October 2010Routine · role: Involved in a Marine Casualty · activity 3874314
3 March 2011Routine · role: Involved in a Marine Casualty · activity 3957259
12 February 2024Routine · role: Involved in a Marine Casualty · 1 injured · activity 7864499
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

VIVIAN L ROEHRIG (2007–2008), CARIBBEAN SEA (2008–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.