Inspection history · 91
13 May 2025
MARPOL Annex IV Survey · COI Inspection · MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8134918
28 January 2025
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8156660
15 April 2024
Deficiency Check · MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7895302
13 November 2023
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7824239
31 October 2023
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7818292
4 October 2023
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7803359
24 January 2023
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7635019
13 June 2022
Internal Structural Exam · Drydock Exam · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7476000
23 March 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7414951
11 January 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7380086
16 March 2021
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7157295
14 January 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam · COI Inspection · Examination of Repairs · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6889127
4 August 2019
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6773283
4 August 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6774506
18 December 2018
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6599659
26 October 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6568775
21 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6182573
30 May 2017
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6181393
12 April 2017
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6122992
13 July 2016
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5931404
13 September 2015
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5744487
29 July 2015
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5199158
7 April 2015
Administrative Inspection · Hull Examination · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5098243
22 July 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4937483
13 July 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4922153
28 June 2013
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4634080
3 April 2012
Administrative Inspection · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4278468
28 February 2012
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4251761
31 October 2011
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4179168
24 March 2009
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3438775
26 June 2008
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3253475
23 October 2007
Examination of Repairs · Hull Examination · Re-Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3085213
27 August 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3040295
23 May 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2938476
5 January 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2852428
19 December 2006
Deficiency Check · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2843275
15 November 2005
COI Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2531846
13 April 2005
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2326427
16 November 2004
MARPOL Annex I Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2242241
2 December 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1957756
16 May 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1794800
16 September 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1693441
5 September 2002
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1670263
28 November 2001
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1440611
31 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073512
31 May 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1065578
30 January 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1056558
9 November 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448202
4 September 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441723
10 July 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397448
9 April 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 54542
4 November 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372809
17 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 794062
18 January 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 114579
16 November 1998
Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467575
20 October 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806884
20 May 1998
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1465382
17 October 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1112156
19 September 1997
Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1400659
8 September 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1121076
29 July 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371925
11 June 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1414653
4 January 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 34089
2 August 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 872137
28 July 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 871991
29 July 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 867045
15 September 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149645
18 August 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 847565
18 August 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 935651
6 August 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 935650
22 June 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 952648
2 March 1992
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387244
20 February 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1469074
16 October 1991
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1253980
18 September 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1249384
30 August 1990
Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 913751
9 August 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 925285
12 April 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1231300
6 March 1990
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1238787
5 February 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1243510
8 September 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 891750
8 August 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1032276
2 September 1988
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1040723
29 August 1988
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1351044
12 August 1988
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1039779
28 June 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1204473
12 May 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1348421
27 August 1987
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1339277
19 June 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1010033
18 June 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 986928
1 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970638
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 January 2025
Resolved
If, during an internal structural, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. Vessel has worklist of several deficiencies.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 16 April 2025
Resolution: All repairs on worklst in documents completed to USCG satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 April 2024
Resolved
Rescue Boat shall be capable of being launched and easily maneuvered. Rescue boat engine would not start. Ensure engine starts and prove proper operation under load to attending MI.
46CFR97.50 & 46CFR94.10-5 (OCT 1994)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2024
Resolution: Verified rescue boat operated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2024
Resolved
Non-metallic flexible hoses may be used in F/O only where flexibility is required not exceeding 30 inches and must meet SAE J1942. F/O Supply and return lines may not be SAE J1942 and are about 10 FT.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2024
Resolution: Piping extended closer to engine and SAE hose of shorter length used.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 15 April 2024
Resolved
Oil transfer hoses shall be hydro tested annually to 1 ½ the MAWP. No record of any hydro test for fuel transfer hoses.
Action required: 703 - Prior to bunkering operations
Resolved 6 May 2024
Resolution: Transfer hose tested.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 April 2024
Resolved
Cable must meet IEEC. Cable supports shall be supported every 610 MM (24 in). Lighting cable supports above winch not adequate.
46 CFR 111.60 (1995)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 6 May 2024
Resolution: Cable supports added.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 15 April 2024
Resolved
It shall be the duty of the Person in Charge to see that provisions of the COI are strictly adhered to. COI requires 2 AB’s and 1 OS. OS credential expired in 2021.
Action required: 10 - Deficiency Rectified
Resolved 15 April 2024
Resolution: Crew member replaced with someone with a valid credential.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 October 2023
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. Due to three separate incidents involving failures in the barge's crane, a complete inspection, testing and certification of the crane and its associated equipment shall be carried out to the satisfaction of a competent person. A competent person is one who meets the requirements of 46 CFR 91.25-25(c). The respective crane shall not be used until the above requirement is met but in no case longer than 14 days from this date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2023
Resolved 13 November 2023
Resolution: Representative from ICGB attended vessel and conducted testing of crane in the presence of marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 April 2023
Resolved
Stateroom doors may have a louver when in "A" or "B" class bulkheads; multiple louvers were ceased. Additionally, multiple fire doors were not self-closing.
46 CFR 92.07-10 (Old I)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2023
Resolution: Verified self closing capabilities of deficient doors. Verified free operation of suspect louvres.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 April 2023
Resolved
At least two accesses to the helicopter landing deck must have a fire hydrant on the unit's fire main system located next to them; only one access had a hydrant. Rectify prior to helo ops.
46 CFR 108.486
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 April 2023
Resolution: Second hydrant installed and operational.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 March 2022
Resolved
All piping, valves and fittings shall meet the applicable requirements of Subchapter F. Fire main leaking near pressure gauge at 90 degree elbow and two cracked welds found. Repair piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2022
Resolved 26 April 2023
Resolution: Fire main repaired.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 23 March 2022
Resolved
Compliance with the standards established by ABS will be considered satisfactory evidence of structural integrity. Railing wasted on winch room roof in vicinity of stairs, walkway supporting grating wasted on port side of crane pedestal, winch room bulkhead and stiffeners found wasted which will be addressed at dry dock. Aft wire guard rail wasted. Repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2022
Resolved 26 April 2023
Resolution: All noted structures/railings were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 March 2022
Resolved
Items of equipment may continue to be in service as long as they are maintained in good condition. Winch room exhaust lagging is deteriorating. Replace lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2022
Resolved 26 April 2023
Resolution: Lagging replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 6 August 2019
Resolved
Electrical fire in portable accommodation module #CG1485498 has made 12-man sleeper uninhabitable. Reduce manning from 66 industrial personnel to 54 industrial personnel till repair proposal has been submitted and approved and effective repairs has been made to satisfaction of the OCMI.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 13 August 2019
Resolution: Distribution panel & damaged wire replaced
Lifesaving › Inflatable Liferafts › Markings
Issued 13 October 2015
Resolved
Provide Life Raft Launching instructions at embarkation station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Instructions posted.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 October 2015
Resolved
Remove or test Fuel transfer hoses on the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Hoses were removed from the vessel
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 October 2015
Resolved
Vessel to replace plastic zip tie wire retention devices with metal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Vessel crew replaced wire retention devices with metal.
Lifesaving › Lifebuoys › Serviceable
Issued 13 October 2015
Resolved
Line on ring buoys fwd port and stbd need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Vessel replaced ring buoy and line.
Engineering › Fuel Oil Service System › Hose
Issued 13 October 2015
Resolved
Vessel currently has 40+ feet of flexible fuel hose installed on the emergency generator. Vessel to install hard piping to limit fexible hose to 30 inches or less.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Vessel installed hard pipe and short sections of flexible approved hose.
Electrical › Electric Supply System (service) › Battery Charger
Issued 13 October 2015
Resolved
Vessel to install drip shields over two battery chargers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Vessel installed drip shields.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 13 October 2015
Resolved
Vessel to install non conductive deck covering around switch board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Vessel installed non conductive deck covering.
Engineering › Fuel Oil Service System › Hose
Issued 13 October 2015
Resolved
Fuel hose and fitting on the crane hoist engine are not approved. Vessel to replace with approved hose.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Hose was replaced with approved hose and fitting.
Construction/Loadline › Structures › Deck Plating
Issued 13 October 2015
Resolved
Repair deck on the crane house level, fwd port cat walk. deck is wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Deck reapair completed.
Communications › Radio Communications › EPIRB
Issued 13 October 2015
Resolved
Vessel to provide documentation on the battery replacement of the EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Vessel provided new EPIRB with documentation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 October 2015
Resolved
Vessel to make repairs to bulkhed between CO2 protected paint locker and work shop. Currently there are several hole in the boundry.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Vessel made repairs to bulkhead.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 October 2015
Resolved
Vessel to install and secure non corrosive boxes for the on deck generator batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Battery boxes installed and secured.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 September 2015
Resolved
Vessel to be manned IAW the issued COI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 October 2015
Resolved 21 October 2015
Resolution: Vessel was issued a Ammended COI as an UNMANNED barge for current operations at the Block Island Wind Farm project. Vessel is working under a Vessel Safety Plan which has been examined by Sector SE New England. Vsl operating under Weeks/Mason mang.
Fire Fighting › Fire Hydrants › Location/Position
Issued 29 July 2014
Resolved
All spaces, including cargo holds, must be able to be reached by 2 streams of water from seperate outlets. One of the streams must be from a single length of hose from a hydrant. On the forward area of the barge, several spaces could not be reached with a single length of hose. Install a new hydrant to ensure all spaces may be accessed with a single length of hose.
Due 27 April 2015
Resolved 29 July 2015
Resolution: New hydrant, hose, and nozzle installed on the forward bulkhead on barge.
Lifesaving › Inflatable Liferafts › Capacity
Issued 29 July 2014
Resolved
Vessel must develop plan to meet 46CFR199.261 (liferaft arrangements) that will satisfy requirement and meet vessels unique layout and operating conditions.
Due 27 April 2015
Resolved 29 July 2015
Resolution: Life rafts relocated/arranged for immediate launching
Lifesaving › Lifebuoys › Stowage
Issued 29 July 2014
Resolved
Lifebouy arrangement was not as per fire safety plan. All life rings on main deck had the lifeline and light attached. As per 46CFR199.70, lifelines must be attached to one buoy on each side of vessel and lights must be on half of all life buoys. However, life buoys may not have both light and line attached. Ensure arrangement is as per fire safety plan.
Due 29 July 2014
Resolved 29 July 2014
Engineering › Pressure Vessel › Relief Valve
Issued 29 July 2014
Resolved
PVHOs may not be used prior to installation of new relief valves.
Due 29 July 2014
Resolved 29 July 2014
Lifesaving › Inflatable Liferafts › Float Free
Issued 28 February 2012
Resolved
Life rafts not properly stowed in brackets
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2012
Lifesaving › Inflatable Liferafts › Markings
Issued 28 February 2012
Resolved
Roster sheets stored in liferaft tubes not legible
Due 29 March 2012
Resolved 1 March 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 February 2012
Resolved
Lights in stbd raceway not working.
Due 29 March 2012
Resolved 1 March 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 28 February 2012
Resolved
Spare fire extinguisher (for fire watch) not properly stored
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 February 2012
Resolved
Bracket for floating light broken on port bow life ring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2012
Communications › Alarms/Indicators › General Alarm
Issued 28 February 2012
Resolved
General alarm bell on stbd crane deck not working and not properly labeled.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2012
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 28 February 2012
Resolved
Fire extinguisher in crane drive room not serviced
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2012
Electrical › Electric Generation Source (service) › Generator
Issued 28 February 2012
Resolved
#2 generator being overhauled and could not be tested. Vessel to provide service ticket upon completion
Due 29 March 2012
Resolved 1 March 2012
Engineering › Compressed Air System (start air) › Valve
Issued 28 February 2012
Resolved
Relief valve on air compressor needs to be changed.
Due 29 March 2012
Resolved 1 March 2012
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 February 2012
Resolved
E-lights not working in lounge, S-11, P-10, 2-L, 3-L and center main deck berthing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 March 2009
Resolved
Properly label each lifejacket storage location.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Documentation › Markings/Placards › Lifejacket Placard
Issued 24 March 2009
Resolved
Post donning placards for each type of lifejacket carried in each location.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Communications › Radio Communications › EPIRB
Issued 24 March 2009
Resolved
Indicate install date on new EPIRB hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 March 2009
Resolved
Install closers on all external class A doors on deck just below the helo deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Communications › Alarms/Indicators › General Alarm
Issued 24 March 2009
Resolved
Properly label each general alarm bell.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 March 2009
Resolved
Install proper blanks in electrical panel in P5 quarters area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Fire Fighting › Nozzles › Condition
Issued 24 March 2009
Resolved
Grease/service all fire nozzles and add safety chains as needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 24 March 2009
Resolved
Add instruction placard for remote controls for fire suppression system in galley.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 24 March 2009
Resolved
Repair or renew handles and safety release on walk-in cooler and freezer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 March 2009
Resolved
Stencil number of lifejackets in storage boxes at stern handrail on 01 deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 24 March 2009
Resolved
Provide at least a 24" pathway into medic's office from outer deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 March 2009
Resolved
Install cover on open J-box for #5 anchor winch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 24 March 2009
Resolved
Install proper hose and backpressure nozzle for internal fuel/lube oil transfers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Lifesaving › Inflatable Liferafts › Float Free
Issued 24 March 2009
Resolved
Relocate 6-man liferaft at bow to the deck hand rail for float-free arrangement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Lifesaving › Inflatable Liferafts › Inflation Characteristics
Issued 24 March 2009
Resolved
Post launching instructions placard for each liferaft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2009
Fire Fighting › Fire Pumps › Arrangement
Issued 14 November 2007
Resolved
Fire pump piping and seachest inoperable and being modified.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Resolution: Fire pump operable. Still awaiting approval on plans to modify seachest.
Construction/Loadline › Structures › Superstructure
Issued 14 November 2007
Resolved
Helo deck not fit for use until re-installation is completed and inspected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 April 2008
Resolution: Helo deck has 2 accesses, 1 primary and an emergency trap door to a ladder.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 November 2007
Resolved
Railing in vicinity of air receiver in winch room removed at some point in time. Needs to be replaced to prevent maintenance personnel from falling from raised deck area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 November 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 November 2007
Resolved
Improper wire splice above air receiver in winch room must be placed in a J-box to remove exposed wire nut arrangement.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 28 April 2008
Resolution: All new wiring and J-boxes installed throughout winch room.
Fire Fighting › Fire Hydrants › Condition
Issued 14 November 2007
Resolved
Fire hose box arrangement prevented suitable deployment of fire hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2007
Resolution: Hose boxes replaced with hose racks.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 November 2007
Resolved
Numerous emergency lights were inoperable throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Resolution: Lights repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 November 2007
Resolved
Exposed wiring near A/C unit on 02 deck, port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 14 November 2007
Resolved
A/C vent covers in accomodation spaces covered with dust and mold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2007
Resolution: Vents cleaned.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 November 2007
Resolved
Freezer failure light missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2007
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 14 November 2007
Resolved
Reefer and freezer escape door handles frozen/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 14 November 2007
Resolved
Some extinguishers were out for service at the time of inspection.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Lifesaving › Lifejacket/PFD (Type II) › Lights
Issued 14 November 2007
Resolved
Numerous lights were expired throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 14 November 2007
Resolved
Painter lines were not attached to the hydrostatic release properly.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Fire Fighting › Fire Hydrants › Condition
Issued 14 November 2007
Resolved
Main deck fire station was missing the hose and nozzle.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 14 November 2007
Resolved
Abundance of loose trash (boxes, etc.) located in phone jack room, crane shack, and electrical closet near fireman's outfits.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Fire Fighting › Firemans Outfit › Quantity
Issued 14 November 2007
Resolved
Firemans outfit locker was full of clutter and miscellanous materials making it hard to locate the required gear.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 November 2007
Resolved
Unsupported wiring runs in vicinity of divers area.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 November 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 November 2007
Resolved
Center course of deck railing was missing wire rope in the vicinity of the crane on the starboard side.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 14 November 2007
Resolved
Broken lighting fixture in winch room inboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2007
Lifesaving › Lifebuoys › Serviceable
Issued 14 November 2007
Resolved
Slag from overhead welding melted through polyproylene line on ringbuoy on stbd side aft.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 14 November 2007
Resolved
EPIRB registration expired and antenna covering cracked.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Fire Fighting › Fire Hydrants › Condition
Issued 14 November 2007
Resolved
Handle on valve broken on fire station under control booth.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 14 November 2007
Resolved
Relocate flammable/combustible aerosols, paints, etc from bilge storage and crane shack or provide approved paint locker.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Lifesaving › Lifebuoys › Immediately Available
Issued 14 November 2007
Resolved
Ringbuoy missing from location at stbd side fwd under crane.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 November 2007
Resolved
Most ringbuoys needed to be re-stenciled.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 November 2007
Resolved
Eyewash station on port side fwd under crane needs to have solution replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 November 2007
Resolved
J-box in superintendants stateroom under crane missing cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2007
Communications › Alarms/Indicators › General Alarm
Issued 14 November 2007
Resolved
Alarm bells on O2 level and in head inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 November 2007
Resolved
Spare extinguishers need to be placed in brackets, or otherwise secured where stowed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 November 2007
Engineering › Fuel Oil Service System › Filter
Issued 14 November 2007
Resolved
Racors in crane shack need plugs installed in pepcocks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 November 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 14 November 2007
Resolved
Non-conductive matting needed in all switchboard locations.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 November 2007
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 14 November 2007
Resolved
Plastic tubing for sight glass on hydraulic tank on crane top needs to be replaced with pyrex/glass.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 November 2007
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 14 November 2007
Resolved
Hydraulic tank on top of crane needs flame screen in vent.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 November 2007
Construction/Loadline › Hull › Side Shell
Issued 22 October 2007
Resolved
Sideshell of tanks #13, #16, and #20 to be inserted due to damage/penetrations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 15 November 2007
Resolution: Satisfactory repairs completed.
Construction/Loadline › Hull › Bottom Plating
Issued 22 October 2007
Resolved
Bottom of tank #5 to be repaired on drydock due to puncture causing space to flood.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 15 November 2007
Resolution: Satisfactory repairs completed.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 5 January 2007
Resolved
Several flammable materials were found stowed throughout various work spaces.
Action required: 705 - Other - as specified
Resolved 16 January 2007
Fire Fighting › Nozzles › Condition
Issued 5 January 2007
Resolved
Two fire hose nozzles were missing the safety chain.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Lifesaving › Lifebuoys › Stowage
Issued 5 January 2007
Resolved
Life ring buoys were not stowed IAW the vessel fire and safety plan. Three needed new retro reflective tape and UV resistant buoyant line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 5 January 2007
Resolved
The CO2 Extinguisher for the paint locker was partially discharged and not properly mounted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 5 January 2007
Resolved
Several old portable fire extinguishers were found laying around the barge. Required the removal of those extinguishers that are no longer serviceable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 5 January 2007
Resolved
Some fire extinguishers were not mounted because the bracket being used was not the correct type for the extinguisher.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 January 2007
Resolved
Several smoke detectors in the living quarters and galley area had dead batteries.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 5 January 2007
Resolved
Lifejacket donning placards were not displayed in the living quarters.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 5 January 2007
Resolved
Emergency lighting units in the galley and quarters area had dead batteries.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 5 January 2007
Resolved
Several dryer units did not have metallic exhaust hoses installed.
Due 31 January 2007
Resolved 16 January 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2007
Resolved
The washroom lighting fixture in quarters S-3 was missing a light cover.
Due 31 January 2007
Resolved 16 January 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 5 January 2007
Resolved
Two circuit breaker panel boxes needed open areas blanked off to exposed wiring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2007
Resolved
One exterior lighting fixture had a broken cover and one was not properly secured to the bulkhead.
Due 31 January 2007
Resolved 16 January 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2007
Resolved
The flood light at the stern off the barge did not have the proper bulb installed and was burning away the paint from the fixture.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Fire Fighting › Fire Pumps › Power Source
Issued 5 January 2007
Resolved
Improper temporary wiring was used to power the fire pump without a junction box to cover the wiring splice.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 5 January 2007
Resolved
Life rafts installed were on loan and had expired hydrostatic releases.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Fire Fighting › Fire Hoses › Condition
Issued 5 January 2007
Resolved
The fire hose at the tower entrance had excessive chaffing.
Action required: 705 - Other - as specified
Resolved 16 January 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 January 2007
Resolved
The EPIRB hydrostatic release was expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Number
Issued 19 December 2006
Resolved
Vessel only had 1 B-V on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2008
Resolution: 2 B-V''s installed at Helo deck access.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 19 December 2006
Resolved
Fire and Safety Plan needs to be reviewed by company and corrected. Upon RTHP in May, local OCMI will be contacted to conduct a walk through and stamp the plan approved if satisfactory.
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 27 March 2009
Resolution: Walked the plan with vsl''s rep and stamped approved after completing corrections.
Lifesaving › Launching Appliances › Release Mechanism
Issued 16 November 2004
Resolved
Bow life-raft is not mounted in a float-free configuration. It is mounted below a catwalk grating which surrounds the crane and protrudes approximately 4 feet over the raft cradle. In addition, when the crane is cradled the counterweight extends over the raft approximately 10-15 feet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 November 2004
Resolution: Sighted move of liferaft location.
Lifesaving › Lifebuoys
Issued 2 December 2003
Resolved
Replace worn out life ring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2003
Resolution: Replaced from stock in company warehouse.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 2 December 2003
Resolved
Clean bunk rooms as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2003
Resolution: Stewards commenced clean up while I was on board. Bunks were stripped, and clean up commenced.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 12 September 2002
Resolved
Weather deck air receiver does not have ledgible data plate. U1A could not be provided and does not have relief valve. Vessel owner shall provide proof of certification and proper installation or install new tank IAW 46CFR Part 54, Prior to use of air receiver. LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 16 November 2004
Resolution: Receiver removed.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 5 September 2002
Resolved
Existing fuel tank access cover is a "one bolt" type, non gas tight cover cover. Required vsl to install an acceptable gas tight bolt down cover prior to next Re-inspection.
Action required: 705 - Other - as specified
Due 10 September 2003
Resolved 16 November 2004
Resolution: Multi-bolt hatch installed with raised coaming around the existing hatch.
Lifesaving
Issued 28 November 2001
Resolved
INSTALL GENERAL ALARM BELL AND LIGHT IN CRANE GENERATOR ROOM IAW 46 CFR 113.25.
Condition: Unknown
Due 28 December 2001
Resolved 7 January 2002
Accommodation/Occupational Safety
Issued 17 February 1999
Resolved
PROVIDE APPROVED PLANS FOR ACCOMODATION SPACES. VESSEL IS RESTRICTED TO HOUSING ONLY FOUR (4) PERSONNEL PER ROOM, TOTAL OF EIGHT (8) PERSONNEL IN EACH ACCOMODATION UNIT UNTIL PLANS ARE APPROVED BY G-MSC.
Condition: Unknown
Due 17 February 1999
Resolved 17 February 1999
Unknown
Issued 16 November 1998
Resolved
PROVIDE UPDATED WATCH STATION BILL.
Condition: Unknown
Due 16 December 1998
Resolved 23 November 1998
Accommodation/Occupational Safety
Issued 16 November 1998
Resolved
PROVIDE APPROVED PLANS FOR ACCOMODATION SPACES.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 16 November 1998
Resolved
CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF A MARINE INSPECTOR PRIOR TO GETTING UNDERWAY ON A MANNED VOYAGE.
Condition: Unknown
Due 16 December 1998
Resolved 23 November 1998
Electrical
Issued 20 May 1998
Resolved
Demonstrate electrical ground detection system operates properly.
Condition: Unknown
Due 21 May 1998
Resolved 26 May 1998
Fire Fighting
Issued 20 May 1998
Resolved
Provide an approved hangar for each portable fire extinguisher.
Condition: Unknown
Due 21 May 1998
Resolved 26 May 1998
Electrical
Issued 20 May 1998
Resolved
Repair oil leak at rear main seal on standby generator.
Condition: Unknown
Due 21 May 1998
Resolved 26 May 1998
Electrical
Issued 20 May 1998
Resolved
Demonstrate overspeed device on standby generator.
Condition: Unknown
Due 21 May 1998
Resolved 26 May 1998
Construction/Loadline
Issued 8 September 1997
Resolved
Drydock date extended. Barge must be drydocked no later than 31OCT97.
Condition: Unknown
Due 8 September 1997
Resolved 8 September 1997
Deck/Cargo
Issued 29 July 1997
Resolved
Observe trips on the main and deck generator.
Condition: Unknown
Due 7 August 1997
Resolved 1 August 1997
Construction/Loadline
Issued 29 July 1997
Resolved
Make starboard stern rake ready for rake inspection. Due no later than thenext hull examination.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Fire Fighting
Issued 29 July 1997
Resolved
Replace the one missing fire axe.
Condition: Unknown
Due 7 August 1997
Resolved 1 August 1997
Fire Fighting
Issued 29 July 1997
Resolved
Provide one fire nozzle and two spanner wrenches for the fire stations.
Condition: Unknown
Due 7 August 1997
Resolved 1 August 1997
Fire Fighting
Issued 29 July 1997
Resolved
Service the vessel's 2 B-V fire extinguishers.
Condition: Unknown
Due 7 August 1997
Resolved 1 August 1997
Lifesaving
Issued 29 July 1997
Resolved
Place retro and the name of the vessel on all ring buoys.
Condition: Unknown
Due 7 August 1997
Resolved 1 August 1997
Deck/Cargo
Issued 29 July 1997
Resolved
Make the vessel's 2 pressure vessels ready for external and internal examination. Due at vessel's next hull examination.
Condition: Unknown
Due 29 July 1997
Resolved 29 July 1997
Navigation
Issued 29 July 1997
Resolved
Repair stern light.
Condition: Unknown
Due 7 August 1997
Resolved 1 August 1997
Construction/Loadline
Issued 11 June 1996
Resolved
PROVIDE CALCULATIONS AND INFORMATION ON "A" FRAME INSTALLED AT THE BOW, IS SATISFACTORY TO THE STABILITY AND SAFETY OF THE VESSEL. SUBMIT SAME TO THE MARINE SAFETY CENTER, WASHINGTON DC FOR APPROVAL. INSTALLED "A" SHALL NOT BE USED UNTIL THIS REQUIREMENT IS SATISFIED, NO LATER THAN AUGUST 1, 1996.
Condition: Unknown
Due 1 August 1996
Resolved 3 July 1996
Documentation
Issued 11 June 1996
Resolved
PROVIDE AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP).
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Accommodation/Occupational Safety
Issued 18 August 1993
Resolved
INSTALL A LOCKING DEVICE ON THE OVERBOARD DISCHARGE VALVE IN CLOSED POSITION.
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Engineering
Issued 18 August 1993
Resolved
CONDUCT INTERNAL EXAMINATION ON THE DIESEL FUEL OIL TANK IN ACCORDANCE WITH46 CFR 91.43-1 ON NEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Electrical
Issued 18 August 1993
Resolved
INSTALL FLAME SHIELD BOWL ON DIESEL GENERATOR FUEL FILTERS.
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Lifesaving
Issued 18 August 1993
Resolved
POST LAUNCHING INSTRUCTION OF LIFERAFT IN THE VICINITY OF THE STOWAGE AREA.
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Documentation
Issued 20 February 1992
Resolved
HAVE ABS CONDUCT AN ANNUAL LOADLINE SURVEY OR, IF SURVEY COMPLETED, HAVE ABS ENDORSE THE REVERSE OF THE CERTIFICATE.
Condition: Unknown
Due 20 February 1992
Resolved 20 February 1992
Lifesaving
Issued 18 September 1991
Resolved
ATTACH WATER LIGHTS TO BODY OF RING BUOYS
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Accommodation/Occupational Safety
Issued 18 September 1991
Resolved
PROPERLY SECURE WASHER, DRYER AND REFRIGERATOR AND PROPERLY WIRE REFIGERATOR.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Electrical
Issued 18 September 1991
Resolved
PROVIDE METALLIC SUPPORTS FOR WIRING ON TOOL ROOM OVERHEAD.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Construction/Loadline
Issued 18 September 1991
Resolved
ATTACH CAPTURE CHAINS TO ALL HATCH COVERS
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Electrical
Issued 18 September 1991
Resolved
PROVIDE SUPPORT BRACKET FOR SHORE TIE CONNECTION
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Electrical
Issued 18 September 1991
Resolved
PROVIDE COVERS FOR LIGHTS IN CRANE MAIN ENGINEROOM
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Fire Fighting
Issued 18 September 1991
Resolved
LABEL FIRE AXES WITH VESSEL NAME
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Electrical
Issued 18 September 1991
Resolved
PROVIDE COVER FOR ELECTRICAL JUNCTION BOX ON TOOL ROOM OVERHEAD AND PROPERLY CONNECT WIRING IN BOX.
Condition: Unknown
Due 18 September 1991
Resolved 18 September 1991
Electrical
Issued 9 August 1990
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL TRIP ON MACHINERY HOUSE GENERATOR.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Accommodation/Occupational Safety
Issued 9 August 1990
Resolved
PROVIDE PROPER PRESSURE/TEMPRATURE RELIEF DEVICE FOR HOT WATER HEATER RATED AT 100PSI AND 200F OR LESS.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Fire Fighting
Issued 9 August 1990
Resolved
PROVIDE 2 FIRE AXES.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Accommodation/Occupational Safety
Issued 9 August 1990
Resolved
PROVE PROPER OPERATION OF PRESSURE RELIEF VALVE ON AIR RECIEVER IN WINCH ROOM TO RELIEVE AT 200PSI OR LESS.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Electrical
Issued 9 August 1990
Resolved
PROVE PROPER OPERATION OF TACHOMETER ON AUX. GENERATOR AND CONDUCT TEST OF OVERSPEED TRIP AND LOW LUBE OIL TRIP.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Fire Fighting
Issued 9 August 1990
Resolved
PROVIDE NAVY ALL PURPOSE NOZZLE FOR STARBOARD FIRE STATION AND SPANNER WRENCHES FOR BOTH FIRE STATIONS.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Lifesaving
Issued 9 August 1990
Resolved
REPLACE ALL 3 RING BUOYS ONBOARD WITH NEW BUOYS. GRAB LINE ON BUOYS DETERIORATED. ENSURE THROWLINES AND LIGHTS ARE ATTACHED TO MAIN BODY OF BUOY.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Construction/Loadline
Issued 5 February 1990
Resolved
REPAIR THE LANDING LIGHTS THAT HAVE CRACKED COLORED LENSES AND REPAIR THE LANDING LIGHT FIXTURES THAT HAVE BROKEN MOUNTINGS.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Construction/Loadline
Issued 5 February 1990
Resolved
PROVIDE IAW APPROVED PLAN NO.1496 42 GENERAL NOTES NO'S 2- WIND DIRECTION INDICATOR, 3- WIND CONE SIZE, 4- FLOOD LIGHTS FOR WIND CONE, 5- HELO DECK MARKINGS, 6- HELO DECK SURFACE PREPERATION FOR STEEL, 7- HELO DECK NON-SKIDSURFACE.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Documentation
Issued 8 August 1989
Resolved
PROVIDE ON BOARD ORIGINAL IOPP CERTIFICATE FOR VESSEL.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Electrical
Issued 8 August 1989
Resolved
PROVE PROPER OPERATION OF TACHOMETER, LOW LUBE OIL TRIP AND OVERSPEED TRIP ON GENERATOR LOCATED IN DECK WINCH HOUSE.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Electrical
Issued 8 August 1989
Resolved
PERMANENTLY INSTALL UL SPEC 1236 BATTERY CHARGERS ON NAV LIGHT POWER CIRCUITS.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Electrical
Issued 8 August 1989
Resolved
PROVIDE ELECTROLYTE-RESISTANT BOX FOR BATTERIES IN CRANE HOUSE.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Electrical
Issued 8 August 1989
Resolved
REMOVE KNIFE SWITCH AND PROVIDE PROPER SWITCH FOR BATTERY INSTALLATION IN CRANE MACHINERY SPACE.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Construction/Loadline
Issued 12 August 1988
Resolved
INSTALL A NATURAL VENTILATION FOR THE PAINT LOCKER. PROVIDE ONE B-II HAND PORTABLE FIRE EXTIGUISHER TO BE STOWED PROPERLY OUTSIDE THE PAINT LOCKER.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Electrical
Issued 12 August 1988
Resolved
REPLACE TWO (2) BLUE LIGHT COVERS, ONE (1) YELLOW LIGHT COVER ON THE HELO PAD. PROVE PROPER PROPER OPERATION OF SAME.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Navigation
Issued 12 August 1988
Resolved
DEMONSTRATE PROPER OPERATION OF THE STERN LIGHT.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Construction/Loadline
Issued 12 August 1988
Resolved
REPLACE GASKETS ON ALL DECK HATCHES.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Fire Fighting
Issued 12 August 1988
Resolved
SERVICE ONE SPARE PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Electrical
Issued 12 August 1988
Resolved
REPLACE INOPERABLE WATER TEMPERATURE GAUGE ON MAIN DIESEL GENERATOR.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Lifesaving
Issued 12 August 1988
Resolved
PROVIDE LIGHTS, WHISTLES AND STENCIL WITH VESSEL'S NAME TO TEN (10) ADDITIONAL LIFE JACKETS.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Lifesaving
Issued 12 August 1988
Resolved
PROVIDE ONE ADDITIONAL IMMERSION SUITS.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Construction/Loadline
Issued 27 August 1987
Resolved
EFFECT PROPER REPAIRS TO THE CRACKED TRANS FRAME MEMBER LOCATED AT FR 5 IN THE PORT FORWARD RAKE. IT IS CRACKED ALONG ITS ROLLED EDGE.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Accommodation/Occupational Safety
Issued 27 August 1987
Resolved
OPEN FOR INTERNAL EXAMINATION THE SEWAGE OVERBOARD DISCHARGE VALVE LOCATED IN 2S VOID.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Construction/Loadline
Issued 19 June 1987
Resolved
PER OPERATOR'S REQUEST AND BASED ON EXAMINATION OF THE VESSEL, THE DUE DATEFOR CREDIT DRYDOCKING OF THE VESSEL HAS BEEN EXTENDED. VESSEL IS TO BE DRYDOCKED FOR CREDIT, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, NOT LATER THAN 01 SEPTEMBER 1987.
Condition: Unknown
Due 19 June 1987
Resolved 19 June 1987