MAURY USCG vessel records
← All vessels

TERMITE

TERMITE is a 1971 towing vessel. The Coast Guard has recorded 45 inspections since 1986, most recently in September 2025, along with 23 deficiencies and 5 casualty investigations between 2002 and 2024.

Records from 1986 to 2025. Most recent: inspection, 26 September 2025.

Built
1971
Last inspected
26 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 26 September 2025
…with no type recorded23
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1986–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8971554
WDK5814
112710
Flag
UNITED STATES
Maury page id
psix-112710

Documentation record

Registered dimensions (L × B × D)55.7 ft × 24.0 ft × 8.2 ft
Registered tonnagegross 106 / net 72
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAM SIRACUSA · SIRACUSAVILLE, LA, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Regulatory (Subpart C or D), Net Ton
106 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 45

26 September 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8242055
29 August 2024 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7991951
30 July 2024 Drydock Extension · Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7970614
2 July 2024 Administrative Inspection · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7941525
23 April 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7900909
2 October 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7795335
29 July 2022 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7588721
11 January 2022 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7378695
11 January 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7380086
4 October 2021 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7326034
22 March 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7160537
3 February 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7135421
28 September 2020 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7066787
1 July 2020 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6998394
18 June 2019 DAPI Audit · Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6717921
28 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6525194
2 December 2015 Industry Initiated Exam · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5785643
13 October 2014 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5019510
6 December 2012 MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4497264
15 November 2011 Administration
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4202619
30 November 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3107219
21 November 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3104615
10 October 2007 Type not recorded
No type recorded · USCGC TARPON (WPB 87310) · USCG Southeast District (CGD-SE) · Activity 3090502
2 August 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2448894
22 July 2004 MTSA/ISPS Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2197338
16 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970616
6 July 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1928203
30 September 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1770180
1 June 2002 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1720628
11 July 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 159428
24 November 1998 Uninspected Towing Vessel
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 806464
27 May 1998 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 34450
25 June 1997 Uninspected Towing Vessel
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1421367
18 August 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 676580
19 July 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 676581
7 July 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 676576
4 July 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 179248
23 June 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 175972
25 February 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 676577
3 February 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 175450
21 December 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 60262
21 December 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 221560
15 January 1992 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 26707
15 January 1992 Uninspected Towing Vessel
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1317728
28 November 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 313016

Deficiency record · 23

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 October 2023 Resolved
All fire detection systems must be inspected, tested and maintained at least once every 12 months. The fire detection system has not been inspected, tested or maintained and had no means to test the reliability of the system. Provide a copy of the attached fire detection nameplate and manufacturers approved design manual. Conduct rounds of the vessel machinery space every 30 minutes during operation.
Action required: 705 - Other - as specified
Resolved 25 January 2024
Resolution: Recieved Report
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2023 Resolved
Employers must maintain records of chemical test as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel did not have documentation of DAPI enrollment for Master and Crew. Provide copies of the DAPI enrollment letter, copy of Masters credential, and list of names of those crew members that are subject to testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2023
Resolution: Submitted doc's
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 October 2023 Resolved
Semi-Portable and Portable fire extinguishers must be inspected and tested IAW 46 CFR 147.60 and 147.65. The annual servicing certificates were not readily available. Please provide copy of servicing certificates.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 October 2023
Resolution: Provided servicing certificates.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 October 2023 Resolved
The frame or support of any size semi-portable fire extinguisher fitted w/ wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling during heavy sea conditions. The semi-portable was not permanently attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2023
Resolution: Isntalled permanent fixture on semi portable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 October 2023 Resolved
Connections and terminations must be suitable and if, twist on type connectors are used, the connection must be made within an enclosure. Wire splices were found in the engine room along the FWD bulkhead IWO STBD Gen set.
Action required: 10 - Deficiency Rectified
Resolved 2 October 2023
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 October 2023 Resolved
A towing vessel > 26ft must carry two lifebuoys meeting 46 CFR 161.010. The SOLAS retro tape is weathered and requires replacement.
Action required: 10 - Deficiency Rectified
Resolved 2 October 2023
Resolution: Replaced retro tape.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 October 2023 Resolved
All lifesaving equipment must be tested and maintained in accordance with the requirements of 46 CFR 199.190. Receipts and records documenting inspections and tests must be retained for 1 year after the expiration of the COI and available upon request. The hydrostatic release certificate showing the validity of the hydro release unit was not on board the vessel.
Action required: 10 - Deficiency Rectified
Resolved 2 October 2023
Resolution: Submitted valid certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 January 2022 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Vessel lost propulsion to starboard main engine. 46 CFR 143.205(c)(1) 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 January 2022
Resolution: MI conducted satisfactory operational tests of newly installed STBD main engine.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 October 2021 Resolved
Each vessel must be designed and constructed to minimize fired hazards insofar as reasonable and practicable. door from galley to engine room is wood and not a rated boundary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2021
Resolved 19 January 2022
Resolution: Installed a fire door
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 October 2021 Resolved
Electrical systems and equpment must function properly and minimize system failures and fire and shock hazards. Two aft engine room light covers are broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2021
Resolved 19 January 2022
Resolution: Changed out the lights.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 September 2020 Resolved
Each towing vessel must be operated to minimize fire hazards; All bilges and void spaces are kept free from accumulation of combustible and flammable liquids. The engine room bilges had oil soaked diapers and an accumulation of oil in the bilges. Clean bilges to the satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 October 2020
Resolution: Oil in bilges was cleaned out.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 September 2020 Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. The forepeak access hatch was missing a gasket. The port 01 deck exterior door was wasted on the bottom exposing the gasket. Port main deck had a stuffing tube that is not filled. Make repairs to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 October 2020
Resolution: Gasket was renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 September 2020 Resolved
The owner/operator must implement procedures to identify and mitigate safety hazards including slips, trips, and falls. The vertical ladder, outside of the wheelhouse, that accessess the top of the wheelhouse has a badly wasted hand rail which presents a fall hazard. Make repairs or replace wasted portion of the vertical ladder.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2020
Resolution: The ladder was cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 September 2020 Resolved
The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure to be questioned by the OCMI. The forepeak space has several tripped stiffeners with broken welds in the overhead along with improperly repaired stiffeners Survey the space and make proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2020
Resolution: Weld repairs were made.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 August 2018 Resolved
IMO: Vsl is broadcasting invalid IMO #, NAME: Vsl is broadcasting incorrect Name
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 April 2019
Resolution: Completed
Unknown
Issued 28 November 1986 Resolved
33CFR159.7(C)(1) THE CAPTAIN OF THE VESSEL OPERATED AN EXISTING VESSEL WITHOUT AN OPERABLE TYPE II OR TYPE III MARINE SANITATION DEVICE.THE BOARDING TEAM OBSERVED THE VESSEL DISCHARGE RAW SEWAGE INTO THE HARBOR.THE VESSEL WAS EQUIPPED WITH INSTALLED TOILET FACILITIES.
Condition: Unknown
Due 28 November 1986
Resolved 28 November 1986
Documentation
Issued 28 November 1986 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Lifesaving
Issued 28 November 1986 Resolved
46CFR25.25-5(C) THE VESSEL DID NOT HAVE A LIFE PRESERVER FOR EACH CREW MEMBER ON BOARD.THE VESSEL HAD A CREW OF FIVE AND HAD ONLY ONE C.G. APPROVED LIFE JACKET.
Condition: Unknown
Due 28 November 1986
Resolved 28 November 1986
Lifesaving
Issued 28 November 1986 Resolved
46CFR25.25-11THE LIFE RINGS ON BOARD THE VESSEL WERE NOT IN SERVICABLE CONDITION.THE PLASTIC COATING OVER THE INNER FLOTATION MATERIAL WAS SPLIT IN SEVERAL AREAS.
Condition: Unknown
Due 28 November 1986
Resolved 28 November 1986
Navigation
Issued 28 November 1986 Resolved
33 USC 2033(A) THE VESSEL DID NOT HAVE A BELL OR A MEANS TO MAKE A NOISE SIMILIAR TO A BELL. THE VESSEL WAS OVER 12 METERS LONG IN THAT THE VESSEL IS 55.7 FEET OR 18.27 METERS
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Lifesaving
Issued 28 November 1986 Resolved
46CFR26.30-1 THE WORK VESTS DID NOT HAVE THE WORDS "WORK VEST" MARKED ON THEM AS REQUIRED BY 46CFR160.053-5(B).
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Navigation
Issued 28 November 1986 Resolved
33CFR88.05 THE VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ON BOARD THE VESSEL IS SELF PROPELLED AND OVER 12 METERS IN LENGTH IN THAT IT IS 55.7 FEET OR 18.27 METERS LONG
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 28 November 1986 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 November 1986
Resolved 28 November 1986

Casualty record · 5

1 June 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1720628
21 November 2007Routine · role: Acknowledged Pollution Source · activity 3104615
1 July 2020Routine · role: Involved in a Marine Casualty · activity 6998394
11 January 2022Routine · role: Involved in a Marine Casualty · activity 7380086
23 April 2024Routine · role: Involved in a Marine Casualty · activity 7900909
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SAVANNAH (2002–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.