Records from 1988 to 2026. Most recent: inspection, 10 March 2026.
Inspection history · 45
10 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8323072
23 October 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8258387
1 August 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8199974
27 January 2025
Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8070817
30 December 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8054276
19 December 2024
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8049644
8 March 2024
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8049431
31 March 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7660592
11 January 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7380086
6 December 2021
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7363500
2 December 2021
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7361021
23 November 2021
Administrative Inspection · Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7356298
22 November 2021
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7355563
20 October 2021
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7336185
5 August 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7278173
18 March 2019
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6644994
29 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6526277
28 October 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5754104
18 June 2014
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4894283
10 May 2014
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4855003
10 May 2014
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4857268
5 May 2014
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4850937
27 September 2013
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4723759
9 April 2013
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4565737
8 August 2011
Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4117079
12 April 2011
Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3985601
20 October 2008
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3348882
14 November 2007
Type not recorded
No type recorded · Station Cortez · USCG Southeast District (CGD-SE) · Activity 3099363
15 April 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2908182
29 November 2006
Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2832066
28 November 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2830304
24 November 2006
Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2827588
6 November 2006
MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2814992
3 November 2006
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2813793
29 September 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2503541
27 January 2005
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2283620
17 January 2003
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1736308
18 April 2001
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1062718
25 July 2000
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1463606
25 March 1999
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1402814
16 November 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 128973
11 July 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 14552
16 January 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 128019
9 November 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 75223
9 February 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1023320
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2026
Resolved
Each towing vessel of 79 feet or more operating on oceans routes must have:(b) Two self-contained breathing apparatus, with a minimum 40-minute air supply. MI observed SCBAs not filled fully.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 March 2026
Resolution: SCBA bottles were repaired and refilled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 March 2026
Resolved
Machinery and electrical systems must be designed an maintained to provide for safe operation of the towing vessel... under normal an emergency conditions. MI observed loose shaft packing nuts on the STBD shaft seal.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2026
Resolved 16 March 2026
Resolution: Packing nuts tightened.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 March 2026
Resolved
The following alarms must be provided: (7) Low fuel level, if fitted with a day tank. MI observed that the STBD day tank did not have a low level alarm.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2026
Resolved 9 April 2026
Resolution: Installed day tank alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 March 2026
Resolved
Each watertight door... must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: "WATERTIGHT DOOR-KEEP CLOSED"...MI observed multiple watertight doors around the ship that were not marked on the outside.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2026
Resolved 13 March 2026
Resolution: Labels were put on the doors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2026
Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed an overhead light fixture in the fore peak unsecured and hanging from the overhead.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2026
Resolved 16 March 2026
Resolution: Light was secured to the overhead.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 March 2026
Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed the hot water heater relief valve leaking.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2026
Resolved 13 March 2026
Resolution: Relief valve replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2026
Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed the No. 1 and No. 2 fuel tanks sight tubes, in the fore peak, not secured to fuel tanks
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2026
Resolved 13 March 2026
Resolution: The sight glasses were secured in place.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 April 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Vessel has plastic waste receptacles on board.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 1 August 2025
Resolution: Received photos of new waste recepticles.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 10 April 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Individual lighting over the bunks in the crews accomodations did not have covers to protect the bulb.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 1 August 2025
Resolution: Received photos of new lighs installled.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 April 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Lighting in the engine room was missing the covers to protect the bulbs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 1 August 2025
Resolution: Received photos of new lighs installled.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 3 January 2025
Resolved
Deficiency issued on 12/23/2024 in MISLE activity 8049644, amended as follows. Item 001, Temporary double installed on #9 & 10 voids watertight bulkhead, whereby bulkhead was found watertight. Doubler to be cropped & renewed too original. Permanent repairs to be completed during upcoming Credit Drydocking and rectified to satisfaction of an attending CG MI within 30 days.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2025
Resolved 4 April 2025
Resolution: Doubler replaced at drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2025
Resolved
Deficiency issued on 12/23/2024 in MISLE activity 8049644, amended as follows. Item 003, Port and Stbd & Port main engines viewed, excessive oil was note observed and appears was removed. Third party vendor or service technician(s) to attend during upcoming drydocking to evaluate and make repairs as required. To be rectified to satisfaction of an attending CG MI within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2025
Resolved 11 September 2025
Resolution: Cleared doing dry-dock charleston
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 January 2025
Resolved
Deficiency issued on 12/23/2024 in MISLE activity 8049644, amended as follows. Item 004, Port side hydraulic winch pump (fwd of port generator) excessive oil was note observed and appears was removed. Third party vendor or service technician(s) to attend during upcoming drydocking to evaluate and make repairs as required. To be rectified to satisfaction of an attending CG MI within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2025
Resolved 4 April 2025
Resolution: Repaired during drydock.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 January 2025
Resolved
Deficiency issued on 12/23/2024 in MISLE activity 8049644, amended as follows Item 005, Gound detection system remain non-operational. Deficiency will be addressed during upcoming Credit Drydocking. Deficiency extended and to be rectified to the satisfaction of an attending CG MI within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2025
Resolved 4 April 2025
Resolution: Repaired during drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 January 2025
Resolved
Deficiency issued on 12/23/2024 in MISLE activity 8049644, amended as follows, Item 008, Company reps unable to demonstrate proper operation of the fix bilge system. Vessel fitted with two portable pumps, with pumping capacity exceeding that fixed bilge pump. Portable pumps to remain onboard, with deficiency extended and to be rectified to the satisfaction of an attending CG MI within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2025
Resolved 4 April 2025
Resolution: Bilge system repaired during drydock.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 December 2024
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Prior to departure of Sector Jacksonville's OCMI zone, vessel must conduct an in-service inspection to the satisfaction of an attending CG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 January 2025
Resolved 23 December 2024
Resolution: Conducted in-service inspection.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 December 2024
Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel.
The watertight bulkhead between void #10 and void #9 is not watertight.
Vessel is required to conduct an internal structural exam to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2025
Resolved 3 January 2025
Resolution: Def cleared, amended & Re-issued in MISLE Activity 8054276
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 19 December 2024
Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of § 142.225 of this subchapter.
Excessive oil found in bilges of machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2025
Resolution: Observed excessive oil removed from machinery space & bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 December 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space.
Multiple leaks found on port and starboard main engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2025
Resolution: Def cleared, amended & Re-issued in MISLE Activity 8054276
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 19 December 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space.
The port side hydraulic winch, FWD of port generator, is leaking.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2025
Resolution: Def cleared, amended & Re-issued in MISLE Activity 8054276
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 December 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
The ground detection system lights are inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2025
Resolution: Def cleared, amended & Re-issued in MISLE Activity 8054276
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 December 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
The electrical switchboard has missing bulbs/connections.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2025
Resolution: Holes plugged.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 December 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention.
The high level bilge alarms were not able to be demonstrated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2025
Resolution: verified machinery space high level alarm & light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 December 2024
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping.
The bilge suction was not able to be demonstrated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2025
Resolution: Def cleared, amended & Re-issued in MISLE Activity 8054276
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 December 2024
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times.
The lifejacket and survival suit lights are expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2025
Resolution: verified new lights installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 December 2024
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times.
The lifebuoy on aft well deck needs to be replaced.
The lifebuoy on port side of exhaust stack needs retro-reflective tape replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2025
Resolution: verified new retro installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 December 2024
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew.
STBD Side data plate was not visible and needs MAWP labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 January 2025
Resolution: verified name plate installed, visible, with 200 working PSI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 December 2024
Resolved
Pressure vessels must be externally examined annually. Relief valves must be tested in accordance w/ 143.245.
Prove proper operation of relief valves and gauges to satisfaction of attending CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 January 2025
Resolution: Verified new 200 psi relief valves installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 August 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 January 2022
Resolution: Vessel recvd COI
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 August 2018
Resolved
CLSN: Vsl is broadcasting Invalid Call Sign (Missing Digit)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 3 December 2018
Resolution: Def Cleared
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 May 2014
Resolved
Vessel has not been conducting security drills at the required 3 month intervals. Provide proof that security drills are being conducted and logged every 3 months to the attending CG Marine Inspector.
Due 10 June 2014
Resolved 17 August 2018