Inspection history · 67
9 October 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8250212
17 April 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8124224
15 April 2025
Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8112379
14 April 2025
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8111207
14 April 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8111268
9 April 2025
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8108598
19 April 2024
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7898071
17 March 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7653404
16 February 2023
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7636435
4 January 2022
Administrative Inspection · Load Line/Change of Employment
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7375930
23 December 2021
Deficiency Check · DAPI Audit · Administrative Inspection · Initial Certification · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7371824
28 May 2020
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6962780
31 March 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6933723
22 January 2020
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6894187
21 January 2020
Damage Survey
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6897367
31 March 2017
Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6115213
26 January 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5059086
11 January 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5053030
19 December 2014
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5042201
28 October 2014
Administration · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5014270
11 March 2014
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4814868
7 June 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4054172
11 May 2011
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4009594
17 November 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3105463
18 February 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2874361
22 November 2006
MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2826994
9 September 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2776484
8 September 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2776344
19 January 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2277381
2 August 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 169338
13 May 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 126618
21 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1726139
19 January 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 767511
14 January 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 199436
5 December 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 162248
5 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 48246
13 August 1999
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1381656
10 August 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 58622
27 March 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 139672
9 February 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 675759
27 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 96588
23 January 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 169848
10 August 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 655290
24 June 1998
Uninspected Towing Vessel
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1130276
22 June 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 767575
27 May 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 675760
23 May 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 188878
23 May 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 195071
30 March 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 195070
30 March 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 755044
19 November 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 655292
12 November 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1959
2 November 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 171799
2 November 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 215796
2 November 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 215864
23 October 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 195068
23 October 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 396952
23 October 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 760975
25 June 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1371459
22 December 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 74238
22 December 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 228919
12 August 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 178204
20 May 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 17262
16 May 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 175223
9 January 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 183674
30 June 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 655286
8 June 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 48875
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 April 2025
No resolution recorded
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in subchapter I. Vessel ran aground while transiting through Sector Detroit's AOR and incurred damage on both propellers, starboard rudder, starboard propeller shaft, starboard support shaft, and the starboard transducer. Vessel has enacted temporary repairs and is able to navigate on one engine (port)Vessel is authorized a one time transit under lightship conditions (not towing) to their homeport in Chicago. Vessel shall go on emergency drydock as soon as it arrives to Chicago and enact permanent repairs to areas damaged to the satisfaction of the local OCMI.
46 CFR 91.30-1
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 19 April 2024
Resolved
Ventilation closures on upper deck for engine room do not close all the way. Repair to proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2024
Resolved 10 May 2024
Resolution: Repaired sealing surface.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 April 2024
Resolved
Heat detector above switchboard in engine room is hanging from its power cable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2024
Resolved 10 May 2024
Resolution: Mounted properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 April 2024
Resolved
Aft towing winch prime mover is leaking red gear oil into the lower level of engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2024
Resolved 10 May 2024
Resolution: Fitting tightend
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 April 2024
Resolved
STBD generator is leaking coolant inboard side while secured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2024
Resolved 10 May 2024
Resolution: Leak repair
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 April 2024
Resolved
PORT generator is missing guard at flywheel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2024
Resolved 10 May 2024
Resolution: guard installed
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 April 2024
Resolved
Clearly mark air receivers with MAWP.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2024
Resolved 10 May 2024
Resolution: marked properly
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2023
Resolved
FWD DRAFT MARKS NEED CONTRASTING PAINT COLOR FROM THE HULL. ENSURE FWD AND AFT DRAFT MARKS ARE VISIBLE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 17 March 2023
Resolution: Draft marks were painted contrasting color to the hull.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2023
Resolved
ELECTRICAL EQUIPMENT MUST BE MARKED WITH CURRENT AND VOLTAGE RATINGS. MULTIPLE POWER PANELS ON VESSEL ARE NOT LABELED.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 March 2023
Resolution: PANELS WERE LABELED PRIOR TO INSPECTORS DEPARTURE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2023
Resolved
DECK WINCH PRIME MOVER EXPANSION TANK HAS A HOLE IN IT. MAKE REPAIRS.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 17 March 2023
Resolution: A 6" x 18" plate has been used to patch hole in expansion tank.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 March 2023
Resolved
GALLEY PORT WTD NEEDS ADJUSTMENTS TO BE WATERTIGHT.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 17 March 2023
Resolution: Galley port WTD has been adjusted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2023
Resolved
ALL RING BUOY GRAB LINES ARE DETERIORATED AND NEED TO BE REPLACED.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2023
Resolved 17 March 2023
Resolution: Ring buoy grab lines have been replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 January 2022
Resolved
Provide Fire Extinguisher and Fire system servicing reports
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2022
Resolution: Servicing records reviewed and added to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 December 2021
Resolved
02 Immersion suits over ten years old need to be Serviced/ Pressure tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2022
Resolution: 02 new suits were added to vessel
Lifesaving
Issued 23 October 1996
Resolved
LIGHTS ON FOUR PFD'S EXPIRED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 23 October 1996
Resolved
COAST PILOT AND LIGHT LIST NOT CORRECTED, COAST PILOT 27TH ED. LIGHT LIST_x001C_ 1993 ED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past