← All vessels
COLUMBIA NEW YORK
Freight Barge · Barge class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named COLUMBIA NEW YORK · DONJON MARINE CO., INC. operator of record, 2023
COLUMBIA NEW YORK is a 1978 freight barge. The Coast Guard has recorded 79 inspections since 1982, most recently in August 2024, along with 159 deficiencies.
Records from 1982 to 2024. Most recent: inspection, 2 August 2024.
- Built
- 1978
- Last inspected
- 2 August 2024
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 159 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
593407
8639326 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCY2356
49686
Flag
UNITED STATES
367340110
Maury page id
psix-49686
Inspections, by type
…with no type recorded10
Years with a record
37 calendar years (1982–2024)
The 79 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)250.0 ft × 72.0 ft × 14.5 ft
Registered tonnagegross 2,322 / net 2,322
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMISENER INDUSTRIES INC · TAMPA, FL, UNITED STATES · built 1978
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 November 2025 · expires 30 November 2026
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2322 - Regulatory (Subpart C or D), Gross Ton
2322 - Regulatory (Subpart C or D), Net Ton
2322 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCY2356MMSI 367340110 · active · voluntarily equipped · granted 9 January 2018, expires 20 March 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspected as a tow unit · 7
The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.
TINA Towing Vessel · MISLE 147622 · 17 December 2008 · activity 3397210DUPLICATE OF MEAGAN ANN (ON 567631) Towing Vessel · MISLE 995283 · 17 December 2008 · activity 3397210MARY ALICE Towing Vessel · MISLE 128905 · 5 April 2001 · activity 75949WITTE 101 Freight Barge · MISLE 344715 · 5 February 1999 · activity 81240JOHN MARSHALL Towing Vessel · MISLE 116179 · 16 May 1994 · activity 175223ARCTIC OCEAN * Freight Ship · MISLE 223750 · 16 May 1994 · activity 175223AL YAMAMAH Freight Ship · MISLE 225864 · 16 May 1994 · activity 175223Inspection history · 79
2 August 2024
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7971887
29 March 2024
Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886827
4 May 2023
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7680788
28 July 2022
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7518620
27 April 2021
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7184089
29 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7164534
10 February 2020
MTSA Verification · Periodic Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6905921
8 April 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6657859
2 August 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6499157
2 April 2018
MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6383176
9 November 2016
COI Inspection · Internal Structural Exam · MTSA/ISPS Verification · Drydock Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038323
18 May 2016
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5880454
7 April 2016
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5848943
30 March 2015
MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5092773
14 November 2014
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5023410
22 January 2014
MARPOL Annex VI Survey · MTSA Verification · Annual Inspection · Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4786174
18 January 2012
MARPOL Annex VI Survey · COI Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4225982
18 October 2011
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4170519
26 January 2011
MTSA Verification · MARPOL Annex V Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3933658
31 March 2010
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3705667
29 January 2010
Damage Survey · MARPOL Annex I Examination · MARPOL Annex V Examination · Administrative Inspection · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3672381
4 June 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3494936
29 January 2009
MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3401879
17 December 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3397210
28 March 2008
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3172821
29 January 2008
MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3137414
31 October 2006
MARPOL Annex I Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2811231
31 January 2006
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2575821
6 July 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2416618
23 May 2005
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2366178
1 July 2004
Annual Inspection · MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2117167
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977765
28 March 2003
Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1764275
3 January 2003
MARPOL Annex V Examination · Annual Inspection · MARPOL Annex I Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1725378
10 January 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1477514
30 October 2001
MARPOL Annex I Examination · MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1376782
5 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 75949
16 November 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 823135
29 September 2000
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1397512
29 April 2000
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1403124
20 September 1999
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1348679
25 August 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1372765
19 May 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1365217
17 May 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1454675
5 February 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 81240
10 November 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 804962
10 June 1998
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 801529
3 March 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1409861
23 September 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135229
6 September 1996
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945725
20 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087557
25 August 1995
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882009
21 July 1994
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 861959
10 June 1994
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1151795
19 May 1994
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1151794
16 May 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 175223
12 May 1994
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1355165
4 August 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 843497
15 June 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843868
22 May 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266197
16 May 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1237700
3 May 1990
Damage Survey · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1225199
5 December 1989
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243101
14 June 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033909
9 June 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033908
12 November 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030732
20 October 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1203269
16 May 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349233
2 May 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343154
28 October 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1325281
23 September 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1007676
27 August 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1030630
14 August 1987
Deficiency Check · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1030627
25 March 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1330323
1 May 1986
MARPOL Annex I Examination · Credit Drydock · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1294649
16 October 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000729
25 September 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987309
4 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972279
13 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972332
Deficiency record · 159
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 March 2024
Resolved
If, during an internal structural exam (ISE), cargo tank internal examination (CTIE), or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be dry-docked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs... The following items were discovered during the internal structural exam.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Forward Starboard rake side shell, In between frame 2 & 3, 1st longitudinal from bottom, wastage including holes throughout frame. Provide ultrasonic soundings to determine the extent of wastage.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 March 2024
Resolved
Forward Starboard rake side shell, In between frame 3 & 4, 1st longitudinal from bottom, wastage throughout frame. Provide ultrasonic soundings to determine the extent of wastage.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Forward Starboard rake side shell, Frame 3, cracked weld at 45 degree, at water line. Crop and renew.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 March 2024
Resolved
Forward Starboard rake Crop and renew 2nd and 3rd tripping brackets counting from bottom.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 March 2024
Resolved
Crop and renew all damage on the 2nd side shell longitudinal from the bottom, located between the 1st and 2nd vertical frame counting from aft.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Crop and renew 2nd, 3rd, and 4rth bottom tripping brackets at the turn of the bilge counting from aft.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Forward rake port side, Replace bottom ladder rung.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Forward rake port side, Crop and renew bottom longitudinal side shell chord wastage where it meets the bottom plating.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Forward rake port side, Crop and renew vertical side chord wastage located next to 3rd vertical frame counting from aft.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Forward rake starboard side, Crop and renew 5th and 6th side shell longitudinal damage where they meet the 1st side shell vertical.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Forward rake starboard side, Crop and renew the 3rd and 4rth forward tripping brackets counting from bottom.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Void 3 Port side, Crop and renew 4rth forward tripping bracket from bottom.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Void 3 Port side, V&W bad weld on 1st vertical frame from forward where it meets the 4rth horizontal up from bottom.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Aft starboard void ladder wasted, crop and renew lower ladder supports.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Aft starboard void chord 1 wastage, Provide ultrasonic soundings to determine the extent of wastage.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Aft starboard void, Crop and renew. chord 1 wastage leading to hole.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Aft starboard void chord 3 cracked weld, V/W.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Void 3 Starboard side, 5th longitudinal from bottom has wastage. Provide ultrasonic soundings to determine the extent of wastage.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Void 1 port side, crop and renew cracked weld at 1st side shell longitudinal from deck, aft of ladder in same bay.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Void 1 port side, crop and renew cracked weld between 1st horizontal stiffener and 4th side shell longitudinal from bottom, same bay as ladder.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Aft port side rake, Pitting in chord 1 and 2 between 1,2, and 3 side frames from top. Provide ultrasonic soundings to determine the extent of wastage.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Aft port side rake, Chord 1- crack weld on number 1 side frame.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 March 2024
Resolved
Aft port side rake, scaling between bottom frames. Provide ultrasonic soundings to determine the extent of wastage.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 March 2024
Resolved
Aft port side rake, No. 1 deck longitudinal crack/wasted. Provide ultrasonic soundings to determine the extent of wastage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 May 2023
Resolved
Nonmetallic flexible hose may be used in lube oil, fuel
oil and fluid power systems only where flexibility is
required and in lengths not exceeding 30 inches
Fuel supply line going to the generator supplying crane
engines exceeds 30 inch. 46CFR56.60-25(b)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 May 2023
Resolved
Shutoff valves of a suitable type shall be installed in
the fuel supply lines, one as close to each tank as
practicable, and one as close to each carburetor as
practicable. There is no fuel shut off valve for the
fuel supply going at the generator supplying crane
engines. 46CFR56.50-75(b)(4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 May 2023
Resolved
The requirements of § 58.10–5 (a), (c), and (d) shall
apply to diesel engine installations. Engine exhaust in
crane machinery space requires lagging from turbine to
exhaust bulkhead penetration. 46CFR58.10-10(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 May 2023
Resolved
The requirements of § 58.10–5 (a), (c), and (d) shall
apply to diesel engine installations. Remove wooden block
used as spacer from exhaust on fwd mooring deck engine
and resecure pipe. 46CFR58.10-10(a
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2023
Resolved
Outlet boxes and junction boxes; general.(c) Each outlet
or junction box must have a cover unless a fixture
canopy, switch cover, receptacle cover, or other cover
is used. Covers multiple open electrical junction boxes
in the crane machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2023
Resolved
(1) Nonmetallic flexible hose must be in accordance with
SAE J1942 (incorporated by reference; see 46 CFR
56.01-2) and may be installed only in vital and nonvital
fresh and salt water systems, nonvital pneumatic
systems, lube oil and fuel systems, and fluid power
systems. Replace two crane hydraulic lines for crane
operation that have chafing on exterior material and
remove nylon rope supporting hydraulic line in machinery
space. 46CFR56.60-25 b
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2023
Resolved
(a) Each panelboard switching unit must be numbered.
(b) Each panelboard must have:
(1) A circuit directory cardholder; and
(2) A circuit directory that has:
(i) The circuit designation of each circuit;
(ii) A description of the load of each circuit; and
(iii) The rating or setting of the overcurrent
protective device for each circuit. Distribution panel
on port side crane machinery space requires labeling. 46CFR111.40-11
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 May 2023
Resolved
All enclosed spaces within the vessel shall be properly
vented or ventilated. Means shall be provided to close
off all vents and ventilators.
Crane machinery ventilation damper is wedged open and
open/close mechanism is broken.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2023
Resolved
Electrical installations on vessels must ensure the
protection of passengers, crew, other persons, and the
vessel from electrical hazards.
Dead end wires on engine and in machinery space. 46 CFR 111.01-1
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 May 2023
Resolved
The construction of each lighting fixture for a nonhazardous
location must meet UL 1598A. No Fixture may be
used as a connection box for a circuit other than the
branch circuit supplying the fixture. Each pendent-type
fixture must be suspended by and supplied through a
threaded, rigid conduit stem.
Drop lights used as primary lighting in machinery space. 46 CFR 111.75-20
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 February 2020
Resolved
Liferafts with an aggregate capacity sufficient to accomodate the total number of persons onboard.
Loaner liferaft onboard has a capacity of 8 instead of the required 10 on COI. Provide proof of 10 person liferaft on board.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 February 2020
Resolved
It shall be the duty of the owner, master, or person in charge to require and have performed at least once in every twelve months the tests and inspections of all hand portable fire extinguishers.
Crew could not produce logs or tags verifying tests and inspections of 04 portable fire extinguishers. Educated crew on requirements, cleared on site.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 10 February 2020
Resolved
All relief valves for pressure vessels shall be set to relieve at a pressure which does not exceed the maximum allowable working pressure.
Crew could not test relief valve on pressure vessel. Operator stated they were purchasing a new relief valve. provide proof of purchase/install.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 February 2020
Resolved
During an ISE damage to the hull plating/structural members were discovered. Submit repair proposal and provide proof of adequate deck thickness throughout deck. Effect permanent repairs.
C/R Tank #1P, 2nd bay from aft topside deck pin hole with light intrusion.
C/R Tank #2P, Fwd bay topside deck pin hole with light intrusion.
C/R Tank #4P, Fwd bay topside deck pin hole with light intrusion.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 February 2020
Resolved
During an ISE damage to the hull plating/structural members were discovered. Submit repair proposal for review and approval prior to effecting permanent repairs.
C/R Tank #5 Center, area marked located on the centerline I-Beam.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2019
Resolved
OPERATINOAL READINESS. Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use.
The lifebuoys (04) were not in operational condition.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2019
Resolved
OPERATINOAL READINESS. Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use.
The light attached to the Port bow lifebuoy was inop.
Engineering › Pressure Vessel › Relief Valve
Issued 7 April 2016
Resolved
The pressure vessel identified on board has not been inspected and is not equipped with a suitable pressure relief valve. Make the vessel available for internal inspection and attach a pressure relief valve, which will be tested in the presence of a USCG Marine Inspector.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 14 November 2014
Resolved
06 Work list items generated from the ISE conducted on 14Nov14. These items will get rectified during the vessel's upcoming dry dock in Oct 2016. Vessel rep is informed that either USCG rep or ABS survey will have to verify the proper repair before dry dock is credited.
Communications › Radio Communications › EPIRB
Issued 22 January 2014
Resolved
Vessel must ensure that the EPIRB hudrostatic release is replaced and properly functioning before operating outside the line of demarcation.
46CFR199-510a
Operations/Management › Pollution › General
Issued 26 January 2011
Resolved
Bunker samples IAW Marpol Annex VI not available for inspection.
Construction/Loadline › Hull › Longitudinal Frame
Issued 31 March 2010
Resolved
1 STBD - C/R bottom SSL IWO Ladder.
Construction/Loadline › Hull › Bracket
Issued 31 March 2010
Resolved
1 STBD - C/R side shell barckets in Fwd Port Corner.
Construction/Loadline › Hull › Transverse Frame
Issued 31 March 2010
Resolved
1 STBD - Between bay 4 & 5 and between bottom longs 2 & 3, C/R transverse frame.
Construction/Loadline › Hull › Longitudinal Frame
Issued 31 March 2010
Resolved
3 Port - Bay 4 & 5, C/R bottoms longs 1 & 2
Construction/Loadline › Hull › Hull Plating
Issued 29 January 2010
Resolved
Affix temporary repairs to crack in #1 starboard rake in way of side shell frame #3 to the satisfaction of ABS/USCG.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 29 January 2010
Resolved
Repair containment plate on main deck to satisfaction of ABS/USCG.
Construction/Loadline › Markings › Fresh Water Load Line
Issued 29 January 2008
Resolved
Repaint Loadline IAW International Load Line Certificate.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 January 2008
Resolved
PROPERLY SECURE BATTERY BOX FOR ALL GENERATORS.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 January 2008
Resolved
Install engine casing/cover for engine on winch stand.
Engineering › Generator (propulsion/auxiliary-electric) › Cable
Issued 29 January 2008
Resolved
Replace worn fuel hose for deck generator.
Engineering › Fuel Oil Service System › Hose
Issued 31 October 2006
Resolved
Install USCG approved fuel hoses on all machinery as discussed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 October 2006
Resolved
Install protective guards IWO pulleys for house, crane, and winch generators.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 31 October 2006
Resolved
Install lagging on exhaust piping for house and crane generators as discussed.
Lifesaving › Immersion Suits › General
Issued 31 October 2006
Resolved
Provide proof of emergency lights for Immersion Suits.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 23 May 2005
Resolved
Vessel found operating without a dry-dock inspection as required by 46CFR91.40. Vessel may not operate outside the boundry line until the vessel receives a credit dry-dock.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2004
Resolved
C/R port side nav light frame.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2004
Resolved
C/R stern light frame.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2004
Resolved
Repaint navigation light screens matte black.
Lifesaving › Inflatable Liferafts › Painter
Issued 1 July 2004
Resolved
Properly refasten painter to liferaft.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 July 2004
Resolved
Replace gaskets on deck opening covers as needed.
Stability › Watertight Integrity › General
Issued 1 July 2004
Resolved
Pump out water in starboard aft void, gas-free and make ready for inspection.
Electrical › Electrical Distribution System (service)
Issued 3 January 2003
Resolved
Replace wires on receptacle (electrical) outside of workshop. LEGACY COMPONENT DESC: Wiring
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 January 2003
Resolved
Replace reflective tape on aft lifebuoys.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 January 2003
Resolved
Replace light on aft lifebuoy.
Construction/Loadline › Structures
Issued 3 January 2003
Resolved
Verify and reattach courses to stanchions as needed. No sail item.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 January 2003
Resolved
Re-mark forward port side lifering.
Stability › Watertight Integrity
Issued 3 January 2003
Resolved
Dewater compartment forward stbd side void tank. No sail item.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 January 2003
Resolved
Remove loose battery on deck forward of deck generator. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Pollution Prevention/Response › Prevention Equipment
Issued 3 January 2003
Resolved
Provide containment around all existing deck fuel tanks. LEGACY COMPONENT DESC: Coamings
Fire Fighting › Combustible Materials
Issued 3 January 2003
Resolved
Remove 5 gal fuel container (diesel) IWO mooring equipment. LEGACY COMPONENT DESC: Open fuel container
Deck/Cargo › Mooring/Anchoring
Issued 3 January 2003
Resolved
Provide guard for cable reel extensions on stbd cable reel. LEGACY COMPONENT DESC: Anchor Cable
Pollution Prevention/Response › Prevention Equipment
Issued 3 January 2003
Resolved
Remove standing oil 5 gal bucket near workshop. LEGACY COMPONENT DESC: Open container (standing oil)
Navigation › Collision/Grounding Avoidance
Issued 3 January 2003
Resolved
Provide anchor light and day shape for same. LEGACY COMPONENT DESC: Day Shapes
Electrical › Electrical Distribution System (service)
Issued 3 January 2003
Resolved
Repair or remove wiring from workshop. If replaced, must be a marine type. LEGACY COMPONENT DESC: Wiring
Engineering › Generator (propulsion/auxiliary-electric)
Issued 3 January 2003
Resolved
Extend exhaust pipe from deck generator to height equivalent above accom. space.
Electrical › Lighting (service)
Issued 3 January 2003
Resolved
Replace holed and missing light covers.
Electrical › Lighting (service)
Issued 3 January 2003
Resolved
Replace or remove inoperable light in head.
Fire Fighting › Fixed Fire Detection System
Issued 3 January 2003
Resolved
Make fire detection system operational. LEGACY COMPONENT DESC: Smoke Detectors
Electrical › Electrical Distribution System (service)
Issued 3 January 2003
Resolved
Remove dead end wiring from overhead abandoned vent. LEGACY COMPONENT DESC: Wiring
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 3 January 2003
Resolved
Service expired fire extinguisher in accom. space. LEGACY COMPONENT DESC: Service
Accommodation/Occupational Safety › Washroom/Toilet
Issued 3 January 2003
Resolved
Provide physical means to secure toilet if not in service. LEGACY COMPONENT DESC: Toilet
Accommodation/Occupational Safety › Potable Water System
Issued 3 January 2003
Resolved
Secure water tank.
Accommodation/Occupational Safety › Messroom
Issued 3 January 2003
Resolved
Remove "fire extinguisher storage box" in galley.
Electrical › Lighting (service)
Issued 3 January 2003
Resolved
Replace inoperable deck light port side of crane.
Deck/Cargo › Mooring/Anchoring
Issued 3 January 2003
Resolved
Make anchor available for inspection. Be able to demonstrate deployment. LEGACY COMPONENT DESC: Anchor
Documentation › Certificates/Documents
Issued 3 January 2003
Resolved
Provide valid load line certificate prior to use of crane. Provide valid cargo gear certificate prior to use of the crane. LEGACY COMPONENT DESC: International Load Line Certificate
Lifesaving
Issued 3 January 2003
Resolved
Vsl not permitted to sail without fire extinguishers, liferaft, railing course repair, and proof of grey water pumped from fwd tank/discharged to a reception facility. No sail item.
Deck/Cargo › Cargo Transfer (solid)
Issued 3 January 2003
Resolved
Make all crane machinery spaces available for CG inspection including air receivers where applicable.
Documentation › Certificates/Documents
Issued 3 January 2003
Resolved
Do not operate crane without valid cargo gear certificate O/B.
Navigation › Collision/Grounding Avoidance
Issued 3 January 2003
Resolved
Provide navigation lights as required. LEGACY COMPONENT DESC: Navigation Lights
Lifesaving
Issued 30 October 2001
Resolved
Galley stove and refrigerator are secured witha rope. Properly secured.
Lifesaving
Issued 30 October 2001
Resolved
Properly stow all gear and equipment on deck. General housekeeping badly needed.
Documentation
Issued 30 October 2001
Resolved
Valid sticker for Documentation certificate not onboard.
Lifesaving
Issued 30 October 2001
Resolved
Ring bouy light inop.
Construction/Loadline
Issued 30 October 2001
Resolved
Gaskets on watertight enclosures worn excessively. Renew and replace.
Electrical
Issued 30 October 2001
Resolved
Metal cover for deck light on portside of crane mounting missing.
Fire Fighting
Issued 30 October 2001
Resolved
Fire extinguisher bracket missing. Extinguishers is being secured with a rope.
Lifesaving
Issued 30 October 2001
Resolved
Epirb hydro release date expired.
Electrical
Issued 30 October 2001
Resolved
Battery for generator not secured.
Electrical
Issued 30 October 2001
Resolved
Breaker panel cover missing and circuit breakers missing inside panel.
Electrical
Issued 30 October 2001
Resolved
lighting fixtures in engine space and outlets in engine space not marine grade or explosion proof.
Navigation
Issued 29 September 2000
Resolved
Paint all nav light brackets flat black.
Navigation
Issued 29 September 2000
Resolved
Make stern light bracket aspect 135 degrees iaw COLREGS.
Navigation
Issued 29 September 2000
Resolved
Fill in holes/repair nav light brackets.
Accommodation/Occupational Safety
Issued 29 September 2000
Resolved
Repair/replace lifelines and stantions on stbd side and stern.
Construction/Loadline
Issued 29 September 2000
Resolved
Permanently affix load line and paint.
Lifesaving
Issued 29 September 2000
Resolved
Replace/service hydro-static release.
Lifesaving
Issued 29 September 2000
Resolved
Stencil full name on all PFD's and immersion suits.
Documentation
Issued 29 April 2000
Resolved
ISSUED CG-835 TO COMPLETE ALL WORKLIST ITEMS PRIOR TO 01MAY00 OR COI WILL BE DEACTIVATED. VESSEL SHALL NOT OPERATE PIOR TO ALL WORKLIST ITEMS CLEAREDBY THE ATTENDING MARINE INSPECTOR.
Navigation
Issued 6 September 1996
Resolved
PROVIDE STBD SIDELIGHT TO INT COLREG STANDARD. BARGE IS RESTRICTED TO DAYLIGHT OPERATION ONLY.
Documentation
Issued 6 September 1996
Resolved
PROVIDE PROOF OF VALID USCG DOCUMENTATION CERTIFICATE TO [name withheld] & PLACEORIGINAL VALID USCG DOCUMENTATION CERTIFICATE ON BOARD.
Electrical
Issued 6 September 1996
Resolved
REMOVE DEAD ENDED WIRING FROM STERN OF VESSEL.
Navigation
Issued 6 September 1996
Resolved
PROVIDE AFT STERNLIGHT TO INT COLREG STANDARD. BARGE IS RESTRICTED TO DAYLIGHT OPERATION ONLY.
Construction/Loadline
Issued 6 September 1996
Resolved
PAINT DRAFT MARKS STBD SIDE AFT.
Construction/Loadline
Issued 6 September 1996
Resolved
REPLACE MANHOLE COVERS FOR HATCH 4 PORT, HATCH 2 STBD & HATCH 3 STBD.
Navigation
Issued 6 September 1996
Resolved
REPAIR/REPLACE PORT SIDELIGHT TO INT COLREG STANDARD.
Navigation
Issued 6 September 1996
Resolved
REPAIR/REPLACE DAYSHAPE STRUCTURE TO INT COLREG STANDARD.
Construction/Loadline
Issued 12 May 1994
Resolved
REPLACE #2 SIDE LONGITUDINAL AFT PORT RAKE.
Construction/Loadline
Issued 12 May 1994
Resolved
REPAIR LONGITUDINAL BULKHEAD AT INBOARD END #2 FRAME, STBD FORWARD RAKE.
Construction/Loadline
Issued 12 May 1994
Resolved
CROP AND RENEW SIDE FRAME STBD AFT RAKE.
Construction/Loadline
Issued 12 May 1994
Resolved
REPAIR CRACKED WELD IN #2 FRAME STBD SIDE, FORWARD RAKE._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 15 June 1993
Resolved
RENEW AS ORIGINAL #6 STARBOARD (AFTERMOST) MOORING CLEAT.
Construction/Loadline
Issued 16 May 1990
Resolved
CLEAN AND RENEW GASKETS AS REQUIRED ON ALL WATERTIGHT HATCH COVERS. MUST COMPLETE BY 15 JUN 90 FOR INTERNAL EXAM CREDIT.
Construction/Loadline
Issued 16 May 1990
Resolved
REPAINT DRAFT MARKS, LOAD LINES AND VESSEL'S NAME. MUST COMPLETE PRIOR TO 15 JUN 90 TO RECEIVE DRYDOCK CREDIT.
Construction/Loadline
Issued 16 May 1990
Resolved
IN BUOYANCY TANK #1C, PICK UP WELDS ON # 3 AND #4 TRANSVERSE FROM FORWARD IN WAY OF FRACTURES THROUGHOUT LENGTH. MUST COMPLETE BY 15 JU 90 FOR INTERNAL EXAM CREDIT.
Construction/Loadline
Issued 16 May 1990
Resolved
IN BUOYANCY TANK 5S,PICK UP WELD ON 1ST WEB FRAME AFT FROM FORWARD BULKHEADIN WAY OF 2ND SIDE LONG FROM BILGE WRAPPER.
Construction/Loadline
Issued 16 May 1990
Resolved
IN BUOYANCY TANK 5S,PICK UP WELD ON 1ST WEB FRAME AFT FROM FORWARD BULKHEADIN WAY OF 2ND SIDE LONG FROM BILGE WRAPPER.
Construction/Loadline
Issued 16 May 1990
Resolved
REMOVE EXCESS WATER FROM ALL COMPARTMENTS .
Navigation
Issued 16 May 1990
Resolved
REPAIR STERN LIGHT. VESSEL MUST CARRY ACCEPTABLE TEMPORARY STERN LIGHT UNTIL THIS REQUIREMENT IS COMPLETE.
Construction/Loadline
Issued 16 May 1990
Resolved
COMPLETE REPAIRS TO BUOYANCY TANK SP SIDE SHELL AND INTERNALS AND 5P/6P BULKHEAD A PER SURVEYORS REPORT.
Construction/Loadline
Issued 16 May 1990
Resolved
REWELD LONGS 2 AND 3 FROM SIDE SHELL TO TRANSVERSE FLOORS WHERE BROKEN LOOSE IN BUOYANCY TANK. MUST COMPLETE PRIOR TO 15 JUN 90 TO RECEIVE INTERNAL EXAM CREDIT.
Construction/Loadline
Issued 16 May 1990
Resolved
INSTALL RETAINER CHAINS ON 2S,5P,5C, AND 7P HATCH COVERS. MUST COMPLETE BY15 JUN 90 FOR INTERNAL EXAM CREDIT.
Construction/Loadline
Issued 16 May 1990
Resolved
MAKE BUOYANCY TANK 7S AVAILABLE FOR INTERNAL INSPECTION NEXT ARRIVAL PORT OF NEW YORK BUT NO LATER THAN 21 MAY 90 TO CONFIRM THIS TANK IS NOT TAKING IN WATER.
Construction/Loadline
Issued 16 May 1990
Resolved
IN BUOYANCY TANK 1P, RENEW TRANSVERSE FLOORS AS MARKED, PICK UP WELDS AS MARKED, RENEW BOTTOM 4FT AND BRACKETS OF OUTBOARD 5 AFT BULKHEAD STIFFENERS. MUST BE COMPLETE BY 15 JUN 90 FOR INTERNAL EXAM CREDIT.
Construction/Loadline
Issued 3 May 1990
Resolved
IN BOSTON AND PRIOR TO RETURN TO NEW YORK OWNER'S REPRESENTATIVE SHALL INSPECT TEMPORARY REPAIRS AND REPORT ANY LEAKAGE, DAMAGE OR PROBLEMS TO THECOGNIZANT OCMI.
Electrical
Issued 3 May 1990
Resolved
SHIM ALL THREE LEAD ACID BATTERIES TO PREVENT SHIFTING UNDERWAY.
Construction/Loadline
Issued 3 May 1990
Resolved
VSL MAY MAKE 1 ROUND TRIP NEW YORK-BOSTON-NEW YORK. VSL SHALL BE DRYDOCKED ON RETURN TO NEW YORK BUT NO LATER THAN 15MAY90 FOR PERMANENT REPAIRS TO 5P SIDESHELL AND INTERNALS AND 5P/6P BULKHEAD.
Construction/Loadline
Issued 3 May 1990
Resolved
PROVIDE DIVERS REPORT OF DAMAGE TO BUOYANCY TANK 5P TO A MARINE INSPECTOR NO LATER THAN 02MAY90.
Construction/Loadline
Issued 3 May 1990
Resolved
PROVIDE A REPAIR PROPOSAL FOR 5P TO A MARINE INSPECTOR NO LATER THAN 02MAY90.
Construction/Loadline
Issued 3 May 1990
Resolved
CONFIRM THAT AIR HISSING FROM 1P, 1C, 1S, 5S & 7C IS NOT DUE TO TAKING ON WATER.
Navigation
Issued 3 May 1990
Resolved
REPAIR STERN LIGHT OR PROVIDE TEMPORARY USCG APPROVED STERN LIGHT PRIOR TO SAILING.
Navigation
Issued 9 June 1989
Resolved
PROVIDE CG APPROVED NAVIGATION LIGHTS (PORT, STBD AND STERN) PRIOR TO LEAVING PORT.
Construction/Loadline
Issued 20 October 1988
Resolved
CROP AND RENEW HEAVY SET-IN SIDE SHELLS AND WRAPPER PLATES 9'X16'X1/2" RESPECTIVELY INCLUDING 2 WEB FRAMES AND BRACKETS ON STBD FWD RAKE.
Accommodation/Occupational Safety
Issued 2 May 1988
Resolved
INSTALL LIFELINES ALONG THE PERIMETER OF THE ENTIRE BARGE.
Construction/Loadline
Issued 2 May 1988
Resolved
RENEW WASTED DECK MOORING CLEAT LOCATED PORT SIDE AFT.
Construction/Loadline
Issued 2 May 1988
Resolved
REPLACE OR REPAIR BOTTOM CORNER BRACKET AT THE CORNERS IN WAY OF VOIDS 7WS AND 7WP AT THE OCTOBER DRYDOCKING.
Construction/Loadline
Issued 2 May 1988
Resolved
PERMANENTLY MARK LOADLINE REFERENCE MARK (PORT AND STARBOARD).
Navigation
Issued 2 May 1988
Resolved
REWIRE SPLICED ELECTRICAL CABLE TO ALL THREE NAVIGATION LIGHTS
Documentation
Issued 14 August 1987
Resolved
PRIOR TO MOVING BARGE, PROVIDE THE FOLLOWING DOCUMENTS TO THE OCMI: COI, IOPP CERT AND COD. DOCUMENTS MUST BE ON BOARD VESSEL BEFORE MOVING THE BARGE.
Navigation
Issued 14 August 1987
Resolved
PRIOR TO GETTING UNDERWAY, MAKE THE PORT RUNNING LIGHT OPERATIONAL.
Construction/Loadline
Issued 14 August 1987
Resolved
CROP AND RENEW THE #4 AND #5 SIDE FRAMES IN WAY OF THE TURN OF THE BILGE INTHE FORWARD STARBOARD RAKE.
Construction/Loadline
Issued 14 August 1987
Resolved
CROP AND RENEW THE STERN LOG VERTICAL STIFFENER AND ASSOCIATED BRACKET AND UNDERDECK BEAM IN THE STARBOARD AFT RAKE.
Construction/Loadline
Issued 14 August 1987
Resolved
CROP AND RENEW THE PORT CORNER BRACKET AND REWELD THE UNDERDECK BEAM IN THEPORT AFT RAKE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.